Search NASA⌕ Search

SEARCH · Search NASA

Results for “SNR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of Advanced Phased-Array Techniques: Interim Results [Slides]

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses.

42 ENGINEERING↗

Evaluation of Three Types of Electric Field Sensors

On June 3-4, 2025, we evaluated three types of electric-field (E-field) sensors: capacitive electrodes, stainless-steel stakes, and porous pots - at two electromagnetic (EM) stations (PWBVI and PWAOF) on Aqueduct Mesa at the Nevada National Security Site. We compared calibrated time series and derived metrics including power spectral density, root-mean-square (RMS) amplitude, signal-to-noise ratio (SNR), and detectability of power line harmonics and Schumann resonance. The objective was to identify an alternative E field sensor with higher SNR than the existing capacitive electrodes. Our data demonstrates that stainless-steel electrodes perform best, with the highest SNR and the most consistent detection of power-line harmonics and Schumann resonance among the three sensor types; they may be used as a supplement to, or replacement for, the existing capacitive electrodes.

58 GEOSCIENCES↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO 3 -based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO 3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO 3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO 3 /carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO 3 /CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression I pa = 3.73 [AMXL] + 0.77 with R 2 = 0.96 and at 0.1 to 30.0 μM with the linear regression I pa = 3.76 [AMXL] + 0.69 with R 2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM –1 cm –2 , respectively. Furthermore, Co-WO 3 /CPE showed high selectivity and anti-interference capabilities. In conclusion, the sensing and disposable Co-WO 3 /CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Shanbhag, Mahesh M. [KLE Technological University,↗

On the Estimation of In-Cloud Vertical Air Motion Using Radar Doppler Spectra

Measurements of in-cloud vertical air motion are key to quantitatively describe cloud dynamics and their role in cloud microphysics. Here, a retrieval technique for estimating the in-cloud vertical air motion using the upward edge of the radar Doppler spectrum is presented. An additional broadening correction factor that depends on the signal-to-noise ratio (SNR) is introduced. A variety of independent measurements are used to assess the performance of the new technique. The vertical air motion is unbiased with an uncertainty of 0.2 m s –1 for SNR <30. Here, the properties of in-cloud vertical air motion are investigated from 1 year of ground-based observations of warm marine boundary layer clouds. Clouds with higher LWP are characterized by stronger vertical air motions compared to those having lower LWP values.

42 ENGINEERING↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

A beamline for ultrafast extreme ultraviolet magneto-optical spectroscopy in reflection near the shot noise limit

High harmonic generation (HHG) makes it possible to measure spin and charge dynamics in materials on femtosecond to attosecond timescales. However, the extreme nonlinear nature of the high harmonic process means that intensity fluctuations can limit measurement sensitivity. Here we present a noise-canceled, tabletop high harmonic beamline for time-resolved reflection mode spectroscopy of magnetic materials. We use a reference spectrometer to independently normalize the intensity fluctuations of each harmonic order and eliminate long term drift, allowing us to make spectroscopic measurements near the shot noise limit. Here, these improvements allow us to significantly reduce the integration time required for high signal-to-noise (SNR) measurements of element-specific spin dynamics. Looking forward, improvements in the HHG flux, optical coatings, and grating design can further reduce the acquisition time for high SNR measurements by 1–2 orders of magnitude, enabling dramatically improved sensitivity to spin, charge, and phonon dynamics in magnetic materials.

47 OTHER INSTRUMENTATION↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

Methods for the robust computation of the long-period seismic spectrum of broad-band arrays

SUMMARY We describe array methods to search for low signal-to-noise ratio (SNR) signals in long-period seismic data using Fourier analysis. This is motivated by published results that find evidence of solar free oscillations in the Earth's seismic hum. Previous work used data from only one station. In this paper, we describe methods for computing spectra from array data. Arrays reduce noise level through averaging and provide redundancy that we use to distinguish coherent signal from a random background. We describe two algorithms for calculating a robust spectrum from seismic arrays, an algorithm that automatically removes impulsive transient signals from data, a jackknife method for estimating the variance of the spectrum, and a method for assessing the significance of an entire spectral band. We show examples of their application to data recorded by the Homestake Mine 3-D array in Lead, SD and the Piñon Flats PY array. These are two of the quietest small aperture arrays ever deployed in North America. The underground Homestake data has exceptionally low noise, and the borehole sensors of the PY array also have very low noise, making these arrays well suited to finding very weak signals. We find that our methods remove transient signals effectively from the data so that even low-SNR signals in the seismic background can be found and tested. Additionally, we find that the jackknife variance estimate is comparable to the noise floor, and we present initial evidence for solar g-modes in our data through the T2 test, a multivariate generalization of Student's t-test.

Caton, Ross C.↗

Combined $\mathrm{APOGEE}$-$\mathrm{GALAH}$ stellar catalogues using the Cannon

APOGEE and GALAH are two high resolution multi-object spectroscopic surveys that provide fundamental stellar parameters and multiple elemental abundance estimates for about half a million stars in the Milky Way. Both surveys observe in different wavelength regimes and use different data reduction pipelines leading to significant offsets and trends in stellar parameters and abundances for the common stars observed in both surveys. Such systematic differences/offsets in stellar parameters and abundances make it difficult to effectively utilize them to investigate Galactic abundance trends in spite of the unique advantage provided by their complementary sky coverage and different Milky Way components they observe. Hence, we use the Cannon data-driven method selecting a training set of 4418 common stars observed by both surveys. This enables the construction of two catalogues, one with the APOGEE-scaled and the other with the GALAH-scaled stellar parameters. Using repeat observations in APOGEE and GALAH, we find high precision in metallicity (~0.02–0.4 dex) and alpha abundances (~0.02–0.03 dex) for spectra with good signal-to-noise ratio (SNR >; 80 for APOGEE and SNR > 40 for GALAH). We use open and globular clusters to validate our parameter estimates and find small scatter in metallicity (0.06 dex) and alpha abundances (0.03 dex) in APOGEE-scaled case. The final catalogues have been cross-matched with the Gaia EDR3 catalogue to enable their use to carry out detailed chemo-dynamic studies of the Milky Way from perspectives of APOGEE and GALAH.

79 ASTRONOMY AND ASTROPHYSICS↗

Progenitors and explosion properties of supernova remnants hosting central compact objects: II. A global systematic study with a comparison to nucleosynthesis models

ABSTRACT Core-collapse explosions of massive stars leave behind neutron stars, with a known diversity that includes the ‘Central Compact Objects’ (CCOs). Typified by the neutron star discovered near the centre of the Cas A supernova remnant (SNR), CCOs have been observed to shine only in X-rays. To address their supernova progenitors, we perform a systematic study of SNRs that contain a CCO and display X-ray emission from their shock-heated ejecta. We make use of X-ray data primarily using the Chandra X-ray observatory, complemented with XMM–Newton. This study uses a systematic approach to the analysis of each SNR aimed at addressing the supernova progenitor as well as the explosion properties (energy and ambient density). After fitting for the ejecta abundances estimated from a spatially resolved spectroscopic study, we compare the data to six nucleosynthesis models making predictions on supernova ejecta yields in core-collapse explosions. We find that the explosion models commonly used by the astrophysics community do not match the ejecta yields for any of the SNRs, suggesting additional physics, for example multidimensional explosion models or updated progenitor structures, are required. Overall we find low-mass (≤25 solar masses) progenitors among the massive stars population and low-energy explosions (<1051 ergs). We discuss degeneracies in our model fitting, particularly how altering the explosion energy affects the estimate of the progenitor mass. Our systematic study highlights the need for improving on the theoretical models for nucleosynthesis predictions as well as for sensitive, high-resolution spectroscopy observations to be acquired with next generation X-ray missions.

79 ASTRONOMY AND ASTROPHYSICS↗

The XRISM first-light observation: Velocity structure and thermal properties of the supernova remnant N 132D

Abstract We present an initial analysis of the X-Ray Imaging and Spectroscopy Mission (XRISM) first-light observation of the supernova remnant (SNR) N 132D in the Large Magellanic Cloud. The Resolve microcalorimeter has obtained the first high-resolution spectrum in the 1.6–10 keV band, which contains K-shell emission lines of Si, S, Ar, Ca, and Fe. We find that the Si and S lines are relatively narrow, with a broadening represented by a Gaussian-like velocity dispersion of $\sigma _v \sim 450$ km s$^{-1}$. However, the Fe He$\alpha$ lines are substantially broadened with $\sigma _v \sim 1670$ km s$^{-1}$. This broadening can be explained by a combination of the thermal Doppler effect due to the high ion temperature and the kinematic Doppler effect due to the SNR expansion. Assuming that the Fe He$\alpha$ emission originates predominantly from the supernova ejecta, we estimate the reverse shock velocity at the time when the bulk of the Fe ejecta were shock heated to be $-1000 \lesssim V_{\rm rs}$ (km s$^{-1}$) $\lesssim 3300$ (in the observer frame). We also find that Fe Ly$\alpha$ emission is redshifted with a bulk velocity of $\sim 890$ km s$^{-1}$, substantially larger than the radial velocity of the local interstellar medium surrounding N 132D. These results demonstrate that high-resolution X-ray spectroscopy is capable of providing constraints on the evolutionary stage, geometry, and velocity distribution of SNRs.

individual objects↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗