Search NASA⌕ Search

SEARCH · Search NASA

Results for “STABLE OSCILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ultra-stable superconducting cavity maser oscillator

An ultra-stable superconducting triple cavity ruby maser oscillator (10) is obtained by providing the oscillator with a superconducting quantum interference device (SQUID) (50), which measures the magnetic field at the ruby (14) and compensates for changes by adjusting the RF pump signal amplitude (42), thereby attaining stabilities of about four orders of magnitude greater than presently attainable.

Strayer, Donald M.↗

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗

Oscillator circuit operates as digitally controlled frequency synthesizer

Oscillator circuit converts digital data from the format of binary information at several input terminals to the format of discrete frequencies at the output terminals. Each state of the input levels corresponds to one frequency at the output. This device provides a large number of accurately controlled frequencies from a single stable oscillator.

Cliff, R. A.↗

NASA Tech Briefs, Februrary 2013

Topics covered include: Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space; Gaseous Nitrogen Orifice Mass Flow Calculator; Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards; Rover Low Gain Antenna Qualification for Deep Space Thermal Environments; Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip; Measuring and Estimating Normalized Contrast in Infrared Flash Thermography; Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source; High-Reliability Waveguide Vacuum/Pressure Window; Methods of Fabricating Scintillators With Radioisotopes for Beta Battery Applications; Magnetic Shield for Adiabatic Demagnetization Refrigerators (ADR); CMOS-Compatible SOI MESFETS for Radiation-Hardened DC-to-DC Converters; Silicon Heat Pipe Array; Adaptive Phase Delay Generator; High-Temperature, Lightweight, Self-Healing Ceramic Composites for Aircraft Engine Applications; Treatment to Control Adhesion of Silicone-Based Elastomers; High-Temperature Adhesives for Thermally Stable Aero-Assist Technologies; Rockballer Sample Acquisition Tool; Rock Gripper for Sampling, Mobility, Anchoring, and Manipulation; Advanced Magnetic Materials Methods and Numerical Models for Fluidization in Microgravity and Hypogravity; Data Transfer for Multiple Sensor Networks Over a Broad Temperature Range; Using Combustion Synthesis to Reinforce Berms and Other Regolith Structures; Visible-Infrared Hyperspectral Image Projector; Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor Change_Detection.m; AGATE: Adversarial Game Analysis for Tactical Evaluation; Ionospheric Simulation System for Satellite Observations and Global Assimilative; Modeling Experiments (ISOGAME); An Extensible, User- Modifiable Framework for Planning Activities; Mission Operations Center (MOC) - Precipitation Processing System (PPS) Interface Software System (MPISS); Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter; Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays; RUSHMAPS: Real-Time Uploadable Spherical Harmonic Moment Analysis for Particle Spectrometers; Powered Descent Guidance with General Thrust-Pointing Constraints; X-Ray Detection and Processing Models for Spacecraft Navigation and Timing; and Extreme Ionizing-Radiation-Resistant Bacterium

Source record↗

Laser Frequency Stabilization for GRACE-II

The GRACE mission monitors changes in the Earth's gravity field by measuring changes in the distance between spacecraft induced by that changing field. The distance variation is measured with a microwave ranging system with sub-micron accuracy. The ranging measurement accuracy is limited by the signal-to-noise ratio and by the frequency stability of the microwave signal referenced to an ultra-stable oscillator (USO). For GRACE-2 a laser ranging system is envisioned with accuracy better than the GRACE microwave ranging system. A laser ranging system easily provides an improved signal-to-noise ratio over the microwave system. Laser frequency stability better than the GRACE USO stability has been demonstrated in several laboratories using thermally stabilized optical cavities. We are developing a space-qualifiable optical cavity and associated optics and electronics for use on GRACE-2 to provide a stable frequency reference for the laser ranging system. Two breadboard units have been developed and tested for performance and ability to survive launch and orbit environments. A prototype unit is being designed using lessons learned from tests of the breadboard units.

Earth gravity↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Real-time dynamic holographic image storage device

A real-time dynamic holographic image storage device uses four-wave mixing in a pair of photorefractive crystals. An oscillation is produced between the crystals which can be maintained indefinitely after the initial object beam is discontinued. The object beam produces an interference pattern in a first crystal to produce phase-conjugated object beam which is directed towards the second crystal. In the second crystal another interference pattern is created which produces a reconstructed object beam. The reconstructed object beam is directed back towards the first crystal. The interference patterns are produced by interaction of the object and phase-conjugated object beam with a read and write beam in each of the crystals. By manipulation of the ratio of the read and write beam intensities in at least one of the crystals, the phase-conjugate or reconstructed object beam output therefrom can be amplified to maintain stable oscillation between the two crystals.

Lafleur, Sharon S.↗

Optical Time Transfer for Bistatic SAR Spacecraft

A spacecraft-to-spacecraft optical time-transfer simulation has been developed as a tool for informing NASA’s Surface Deformation and Change (SDC) mission architecture. The SDC mission will combine radar images from multiple spacecraft to improve understanding of the Earth’s sea-level and landscape changes. Spacecraft must be precisely synchronized in order to create sharp radar images. Simulation of multiple spacecraft time-synchronizing via laser communication can inform technology choices of a mission by providing a picosecond-precision level estimate of clock error. This timing and ranging simulation has been combined with a radar system performance analysis pipeline. The simulated timing errors are used to predict performance of bistatic SAR systems in the presence of oscillator noise and time synchronization in accuracy. This analysis includes both analytic approximation equations from existing literature, and a numerical radar simulation to extract key system performance parameters like phase error and signal-to-noise ratio (SNR)degradation. Precision time-transfer techniques facilitate the accurate synchronization of clocks between any combination of terminals. Most time-transfer technology for comparing two clocks at different terminals use radio frequencies (RF) to measure the time delay between the sending and receiving of signals. Laser technology offers the capability to transmit high data rates with systems that are of smaller size and lower power than comparable RF systems. The clocks on independent spacecraft will have some phase and frequency errors between them that result in clock drift. The two clock models that are included in this bi-directional MATLAB simulation are a cesium-based Chip-Scale Atomic Clock (CSAC) and a rubidium-based Miniature Atomic Clock (MAC). The CSAC has flown as hardware for small satellite missions such as the University of Florida’s CHOMPTT mission. A study of example orbits, including that of NASA NASA-ISRO Synthetic Aperture Radar Mission (NISAR) mission, and lasing rates demonstrate the impact of flight configuration parameters on the synchronization error between two spacecraft. The MATLAB timing simulation uses a Runge-Kutta 4th-order method to propagate spacecraft orbits and computes the light-travel time estimate between them. The simulation outputs the estimated range and estimated clock error based on a user-defined spacecraft cluster configuration. The radar simulation and analytic approximations are applied to evaluate a potential future NASA bistatic SAR constellation architecture. In the proposed architecture, satellites follow each other in the same orbit at 800 km altitude, with a 210 km baseline. We also baseline the CSAC as an ultra stable oscillator, and use NASA’s NISAR for baseline radar system parameters to compute a clock-system introduced phase error of 5.6 degrees without synchronization by frequent time transfer. We build on this base case with a sensitivity analysis of radar performance over a proposed range of constellation and radar system parameters. With this analysis pipeline, we comment on which radar parameters should or should not be changed to minimize synchronization requirements. This analysis technique could be extended or modified to evaluate the timing requirements of other geometries for other future multistatic SAR missions, or other interferometric satellite missions.

Surface Deformation and Change↗

Lunar subsurface exploration with coherent radar.

The Apollo Lunar Sounder Experiment that is scheduled to orbit the moon on Apollo 17 consists of a three frequency coherent radar system and an optical recorder. The coherent radar can be used to measure both phase and amplitude characteristics of the radar echo. Measurement methods that are related to the phase and amplitude will be used to determine the surface profile, locate subsurface features and ascertain near surface electrical properties of the lunar surface. The key to the coherent radar measurement is a highly stable oscillator that preserves an accurate phase reference (2 or 3 electrical degrees) over a long period of time. This reference provides a means for reducing surface clutter so that subsurface features are more easily detected and also provides a means of measuring range to the surface to within a fraction of a wavelength.

Brown, W. E., Jr.↗

A novel laser ranging system for measurement of ground-to-satellite distances

A technique was developed for improving the precision of laser ranging measurements of ground-to-satellite distances. The method employs a mode-locked laser transmitter and utilizes an image converter tube equipped with deflection plates in measuring the time of flight of the laser pulse to a distant retroreflector and back. Samples of the outgoing and returning light pulses are focussed on the photocathode of the image converter tube, whose deflection plates are driven by a high-voltage 120 MHz sine wave derived from a very stable oscillator. From the relative positions of the images produced at the output phosphor by the two light pulses, it is possible to make a precise determination of the fractional amount by which the time of flight exceeds some large integral multiple of the period of the deflection sinusoid.

Golden, K. E.↗

Laser ranging system with 1-cm resolution.

A laser ranging system has been developed in which an image converter tube equipped with deflection plates is used to make a precise measurement of the fractional amount by which the time of flight of the ranging pulse exceeds an integral multiple N of the period of a stable oscillator. The value of N is determined in an auxiliary measurement. In short-range tests with a laboratory breadboard version of the system, time-of-flight uncertainties of about 45 psec were observed. The corresponding uncertainty in a range measurement is smaller than 7 mm.

Golden, K. E.↗

System design of the Pioneer Venus spacecraft. Volume 7: Communication subsystem studies

Communications subsystem tradeoffs were undertaken to establish a low cost and low weight design consistent with the mission requirements. Because of the weight constraint of the Thor/Delta launched configuration, minimum weight was emphasized in determining the Thor/Delta design. In contrast, because of the greatly relaxed weight constraint of the Atlas/Centaur launched configuration, minimum cost and off the shelf hardware were emphasized and the attendant weight penalities accepted. Communication subsystem hardware elements identified for study included probe and bus antennas (CM-6, CM-17), power amplifiers (CM-10), and the large probe transponder and small probe stable oscillator required for doppler tracking (CM-11, CM-16). In addition, particular hardware problems associated with the probe high temperature and high-g environment were investigated (CM-7).

Newlands, D. M.↗

Measurements of small signal absorption at high temperature for the 001-100 band of CO2

In the experiments an absorption cell was irradiated by a polarized CW CO2-N2-He laser. By changing the length of the laser cavity, it was possible to obtain stable oscillations on the five lines P12 through P20 in the 10.4-micron band. The power output was slightly under 10 W. Intensity measurements of the incident and the transmitted beam were conducted when the cell was filled with a nonabsorbing calibrating gas (nitrogen) and with the test gas (carbon dioxide). Data for the absorption coefficient in the temperature range from 300 K to about 600 K are presented in graphs.

Leonard, R. L.↗

The TWERLE balloon-to-satellite data transmitting system

This paper describes the balloon instrumentation system which provides the one-way link for data gathering and navigation in the Tropical Wind, Energy conversion and Reference Level Experiment (TWERLE). In this experiment, 400 instrumented constant-level balloons will be launched at the southern hemisphere during 1975. The Random Access Measurement System (RAMS) on board the Nimbus-F satellite, will comprise the receiving end of the link. The data encoder, stable oscillator, transmitter and antenna are described, as well as two supporting components, the power source and the magnetic cutdown. These six items weigh 850 g. The oscillator-transmitter consume 1.9 W dc power to provide 0.6 W phase modulated RF power.

Levanon, N.↗

Ultrastable automatic frequency control

Center frequency of wideband AFC circuit drifts only hundredths of percent per day. Since circuit responds only to slow frequency drifts and modulation signal has high-pass characteristics, AFC does not interfere with normal FM operation. Stable oscillator, reset circuit, and pulse generator constitute time-averaging discriminator; digital counter in pulse generator replaces usual monostable multivibrator.

Sabourin, D. J.↗

GPS application to mapping, charting and geodesy

GPSPAC, a receiver being developed for space applications by the Defense Mapping Agency and NASA, will use signals from GPS constellations to generate real-time values of host vehicle position and velocity. The GPSPAC has an L-band antenna and preamp capable of receiving the 1575 MHz and 1227 MHz spread spectrum signals; its stable oscillator at 5.115 MHz provides the basic frequency reference, resulting in a long term drift of less than one part in 10 to the -10th day. The GPSPAC performs many functions on board the spacecraft which were previously relegated to large-scale ground-based computer/receiver systems. A positional accuracy of better than 8 can be achieved for those periods when four or more NAVSTAR satellites are visible to the host satellite. The GPS geodetic receiver development, which will provide prototype receivers for utilization in terrestrial surveying operations, has the potential to significantly enhance the accuracy of point geodetic surveys over the current user hardware capability.

Senus, W. J.↗

Cosmic background explorer (COBE) navigation with TDRSS one-way return-link Doppler in the post-helium-venting phase

A navigation experiment was performed which establishes Ultra-Stable Oscillator (USO) frequency stabilized one way return link Doppler TDRSS tracking data as a feasible option for mission orbit determination support at the Goddard Space Center Flight Dynamics Facility. The study was conducted using both one way and two way Tracking and Data Relay Satellite System (TDRSS) tracking measurements for the Cosmic Background Explorer (COBE) spacecraft. Tracking data for a 4 week period immediately follow the depletion of the helium supply was used. The study showed that, for both definitive orbit solution and short term orbit prediction (up to 4 weeks), orbit determination results based on one way return link Doppler tracking measurements are comparable to orbit determination results based on two way range and two way Doppler tracking measurements.

Nemesure, M.↗

A new solar cycle model including meridional circulation

A kinematic model is presented for the solar cycle which includes not only the transport of magnetic flux by supergranular diffusion and a poleward bulk flow at the sun's surface, but also the effects of turbulent diffusion and an equatorward 'return flow' beneath the surface. As in the earlier models of Babcock and Leighton, the rotational shearing of a subsurface poloidal field generates toroidal flux that erupts at the surface in the form of bipolar magnetic regions. However, such eruptions do not result in any net loss of toroidal flux from the sun (as assumed by Babcock and Leighton); instead, the large-scale toroidal field is destroyed both by 'unwinding' as the local poloidal field reverses its polarity, and by diffusion as the toroidal flux is transported equatorward by the subsurface flow and merged with its opposite hemisphere counterpart. The inclusion of meridional circulation allows stable oscillations of the magnetic field, accompanied by the equatorward progression of flux eruptions, to be achieved even in the absence of a radial gradient in the angular velocity. An illustrative case in which a subsurface flow speed of order 1 m/s and subsurface diffusion rate of order 10 sq km/s yield 22-yr oscillations in qualitative agreement with observations.

Wang, Y.-M.↗