Search NASA⌕ Search

SEARCH · Search NASA

Results for “STAGNATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Stagnation-point Heat Transfer to Blunt Shapes in Hypersonic Flight, Including Effects of Yaw

An approximate theory is developed for predicting the rate of heat transfer to the stagnation region of blunt bodies in hypersonic flight. Attention is focused on the case where wall temperature is small compared to stagnation temperature. The theoretical heat-transfer rate at the stagnation point of a hemispherical body is found to agree with available experimental data. The effect of yaw on heat transfer to a cylindrical stagnation region is treated at some length, and it is predicted that large yaw should cause sizable reductions in heat-transfer rate.

Eggers, A J , Jr↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence From a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half scale model of a can-type combustor from a low NO(x), ground based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counter clockwise direction (facing downstream). A 5-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36' at the outer edges of the rectangular test section. Hot wire measurements showed test section flow had very high levels of turbulence, around 28.5 percent, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77 percent and was about 14 percent higher than predicted by a previously developed correlation for isotropic grid generated turbulence.

VanFossen, G. James↗

Augmentation of Stagnation Region Heat Transfer Due to Turbulence from a DLN Can Combustor

Heat transfer measurements have been made in the stagnation region of a flat plate with a circular leading edge. Electrically heated aluminum strips placed symmetrically about the leading edge stagnation region were used to measure spanwise-averaged heat transfer coefficients. The maximum Reynolds number obtained, based on leading edge diameter, was about 100,000. The model was immersed in the flow field downstream of an approximately half-scale model of a can-type combustor from a low NO(x), ground-based power-generating turbine. The tests were conducted with room temperature air; no fuel was added. Room air flowed into the combustor through six vane-type fuel/air swirlers. The combustor can contained no dilution holes. The fuel/air swirlers all swirled the incoming airflow in a counterclockwise direction (facing downstream). A five-hole probe flow field survey in the plane of the model stagnation point showed the flow was one big vortex with flow angles up to 36 deg at the outer edges of the rectangular test section. Hot-wire measurements showed test section flow had very high levels of turbulence, around 28.5%, and had a relatively large axial-length scale-to-leading edge diameter ratio of 0.5. X-wire measurements showed the turbulence to be nearly isotropic. Stagnation heat transfer augmentation over laminar levels was around 77% and was about 14% higher than predicted by a previously developed correlation for isotropic grid-generated turbulence.

VanFossen, G. James↗

Stagnation Region Heat Transfer Augmentation at Very High Turbulence Levels

A database for stagnation region heat transfer has been extended to include heat transfer measurements acquired downstream from a new high intensity turbulence generator. This work was motivated by gas turbine industry heat transfer designers who deal with heat transfer environments with increasing Reynolds numbers and very high turbulence levels. The new mock aero-combustor turbulence generator produces turbulence levels which average 17.4%, which is 37% higher than the older turbulence generator. The increased level of turbulence is caused by the reduced contraction ratio from the liner to the exit. Heat transfer measurements were acquired on two large cylindrical leading edge test surfaces having a four to one range in leading edge diameter (40.64 cm and 10.16 cm). Gandvarapu and Ames [1] previously acquired heat transfer measurements for six turbulence conditions including three grid conditions, two lower turbulence aero-combustor conditions, and a low turbulence condition. The data are documented and tabulated for an eight to one range in Reynolds numbers for each test surface with Reynolds numbers ranging from 62,500 to 500,000 for the large leading edge and 15,625 to 125,000 for the smaller leading edge. The data show augmentation levels of up to 136% in the stagnation region for the large leading edge. This heat transfer rate is an increase over the previous aero-combustor turbulence generator which had augmentation levels up to 110%. Note, the rate of increase in heat transfer augmentation decreases for the large cylindrical leading edge inferring only a limited level of turbulence intensification in the stagnation region. The smaller cylindrical leading edge shows more consistency with earlier stagnation region heat transfer results correlated on the TRL (Turbulence, Reynolds number, Length scale) parameter. The downstream regions of both test surfaces continue to accelerate the flow but at a much lower rate than the leading edge. Bypass transition occurs in these regions providing a useful set of data to ground the prediction of transition onset and length over a wide range of Reynolds numbers and turbulence intensity and scales.

20 FOSSIL-FUELED POWER PLANTS↗

Effects of platinum stagnation surface on the lean extinction limits of premixed methane/air flames at moderate surface temperatures

A stagnation flow reactor was used to study the effects of platinum on the lean flammability limits of atmospheric pressure premixed methane/air flames at moderate stagnation surface temperatures. Experimental and computational methods were used to quantify the equivalence ratio at the lean extinction limit ({phi}{sub ext}) and the corresponding stagnation surface temperature (T{sub s}). A range of flow rates (57-90 cm/s) and corresponding strain rates were considered. The results indicate that the gas-phase methane/air flames are sufficiently strong relative to the heterogeneous chemistry for T{sub s} conditions less than 750 K that the platinum does not affect {phi}{sub ext}. The computational results are in good agreement with the experimentally observed trends and further indicate that higher reactant flow rates (>139 cm/s) and levels of dilution (>{proportional_to}10% N{sub 2}) are required to weaken the gas-phase flame sufficiently for surface reaction to play a positive role on extending the lean flammability limits. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective versus ion thermal temperatures in the Weizmann Ne Z-pinch: Modeling and stagnation physics

The difference between the ion thermal and effective temperatures is investigated through simulations of the Ne gas puff z-pinch reported by Kroupp et al. [Phys. Rev. Lett. 107, 105001 (2011)]. Calculations are performed using a 2D, radiation-magnetohydrodynamic code with Tabular Collisional-Radiative Equilibrium, namely Mach2-TCRE [Thornhill et al., Phys. Plasmas 8, 3480 (2001)]. The extensive data set of imaging and K-shell spectroscopy from the experiments provides a challenging validation test for z-pinch simulations. Synthetic visible images of the implosion phase match the observed large scale structure if the breakdown occurs at the density corresponding to the Paschen minimum. At the beginning of stagnation (−4 ns), computed plasma conditions change rapidly showing a rising electron density and a peak in the ion thermal temperature of ∼1.8 keV. This is larger than the ion thermal temperature (<400 eV) inferred from the experiment. By the time of peak K-shell power (0 ns), the calculated electron density is similar to the data and the electron and ion thermal temperatures are equilibrated, as is observed. Effective ion temperatures are obtained from calculated emission line widths accounting for thermal broadening and Doppler velocity shifts. The observed, large effective ion temperatures (∼4 keV) early in the stagnation of this Ne pinch can be explained solely as a combination of compressional ion heating and steep radial velocity gradients near the axis. Approximations in the modeling are discussed in regard to the higher ion thermal temperature and lower electron density early in the stagnation compared to the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Target geometrical effects on the stagnation layer formed by colliding a pair of laser produced copper plasmas

We present the results of a time and space resolved optical-spectroscopic study of colliding plasmas formed at the front surfaces of flat and inclined Cu slab targets as a function of both the distance and the wedge angle between them for angles ranging from 100° to 180° (laterally colliding plasmas). The key parameters studied are stagnation layer density, temperature, duration, and kinetics of atomic/ionic spatial distributions and all have been found to vary significantly with wedge angle. It is found that the density and temperature of the stagnation layer decrease with increasing wedge angle. It is also found that the larger the wedge angle, the tighter and more well defined the stagnation layer formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stagnation region heat transfer augmentation at very high turbulence levels

Current land-based gas turbines are growing in size producing higher approach flow Reynolds numbers at the leading edge of turbine nozzles. These vanes are subjected to high intensity large scale turbulence. This present paper reports on the research which significantly expands the parameter range for stagnation region heat transfer augmenta-tion due to high intensity turbulence. Heat transfer measurements were acquired over two constant heat flux test surfaces with large diameter leading edges (10.16 cm and 40.64 cm). The test surfaces were placed downstream from a new high intensity (17.4%) mock combustor and tested over an eight to one range in approach flow Reynolds number for each test surface. Stagnation region heat transfer augmentation for the smaller (Re D = 15,625–125,000) and larger (Re D = 62,500–500,000) leading edge regions ranged from 45% to 81% and 80% to 136%, respectively. Furthermore, these data also include heat transfer distributions over the full test surface compared with the earlier data acquired at six additional inlet turbulence conditions. These surfaces exhibit continued but more moderate acceleration downstream from the stagnation regions and these data are expected to be useful in testing bypass transition predictive approaches. This database will be useful to gas turbine heat transfer design engineers. [DOI: 10.1115/1.4032677]

20 FOSSIL-FUELED POWER PLANTS↗

Emission characteristics and dynamics of the stagnation layer in colliding laser produced plasmas

The expansion dynamics of ion and neutral species in laterally colliding laser produced aluminum plasmas have been investigated using time and space resolved optical emission spectroscopies and spectrally and angularly resolved fast imaging. The emission results highlight a difference in neutral atom and ion distributions in the stagnation layer where, at a time delay of 80 ns, the neutral atoms are localized in the vicinity of the target surface (<1 mm from the target surface) while singly and doubly charged ions lie predominantly at larger distances, <1.5 and <2 mm, respectively. The imaging results show that the ions were found to form a well defined, but compressed, stagnation layer at the collision front between the two seed plasmas at early times ({Delta}t<80 ns). On the other hand, the excited neutrals were observed to form a V-shaped emission feature at the outer regions of the collision front with enhanced neutral emission in the less dense, cooler regions of the stagnation layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of stagnation performance metrics in magnetized liner inertial fusion experiments using Bayesian data assimilation

Here we present a new analysis methodology that allows for the self-consistent integration of multiple diagnostics including nuclear measurements, x-ray imaging, and x-ray power detectors to determine the primary stagnation parameters, such as temperature, pressure, stagnation volume, and mix fraction in magnetized liner inertial fusion (MagLIF) experiments. The analysis uses a simplified model of the stagnation plasma in conjunction with a Bayesian inference framework to determine the most probable configuration that describes the experimental observations while simultaneously revealing the principal uncertainties in the analysis. We validate the approach by using a range of tests including analytic and three-dimensional MHD models. An ensemble of MagLIF experiments is analyzed, and the generalized Lawson criterion χ is estimated for all experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A general stagnation-point convective heating equation for arbitrary gas mixtures

The stagnation-point convective heat transfer to an axisymmetric blunt body for arbitrary gases in chemical equilibrium was investigated. The gases considered were base gases of nitrogen, oxygen, hydrogen, helium, neon, argon, carbon dioxide, ammonia, and methane and 22 gas mixtures composed of the base gases. Enthalpies ranged from 2.3 to 116.2 MJ/kg, pressures ranged from 0.001 to 100 atmospheres, and the wall temperatures were 300 and 1111 K. A general equation for the stagnation-point convective heat transfer in base gases and gas mixtures was derived and is a function of the mass fraction, the molecular weight, and a transport parameter of the base gases. The relation compares well with present boundary-layer computer results and with other analytical and experimental results. In addition, the analysis verified that the convective heat transfer in gas mixtures can be determined from a summation relation involving the heat transfer coefficients of the base gases. The basic technique developed for the prediction of stagnation-point convective heating to an axisymmetric blunt body could be applied to other heat transfer problems.

Sutton, K.↗

A visual investigation of turbulence in stagnation flow about a circular cylinder

A diagnostic visualization study of turbulence in stagnation flow around a circular cylinder was carried out to gain physical insight into the coherent structure of turbulence in flow around a bluff body advanced by the vorticity-amplification theory. The visualization was conducted at a cylinder-diameter Reynolds number of 8000 utilizing titanium dioxide white smoke for an approaching flow containing turbulence at scales larger than the neutral wavelength of the stagnation flow. Analyses of the flow events focused on tracing out the temporal and spatial evolution of a cross-vortex tube outlined by the entrained smoke filaments from its emergence near the stagnation zone through its penetration into the cylinder boundary layer.

Sadeh, W. Z.↗

Turbulence and surface heat transfer near the stagnation point of a circular cylinder in turbulent flow

A turbulent boundary layer flow analysis of the momentum and thermal flow fields near the forward stagnation point due to a circular cylinder in turbulent cross flow is presented. Turbulence modeling length scale, anisotropic turbulence initial profiles and boundary conditions were identified as functions of the cross flow turbulence intensity and the boundary layer flow far field velocity. These parameters were used in a numerical computational procedure to calculate the mean velocity, mean temperature, and turbulence double correlation profiles within the flow field. The effects of the cross flow turbulence on the stagnation region momentum and thermal flow fields were investigated. This analysis predicted the existing measurements of the stagnation region mean velocity and surface heat transfer rate with cross flow Reynolds number and turbulence intensity less than 250,000 and 0.05, respectively.

Wang, C. R.↗

The influence of jet-grid turbulence on heat transfer from the stagnation region of a cylinder in crossflow

The effect of high-intensity turbulence on heat transfer from the stagnation region of a circular cylinder in crossflow was studied. The work was motivated by the desire to be able to more fully understand and predict the heat transfer to the leading edge of a turbine airfoil. In order to achieve high levels of turbulence with a reasonable degree of isotropy and homogeneity, a jet-injection turbulence grid was used. The jet grid provided turbulence intensities of 10 to 12 percent, measured at the test cylinder location, for downstream blowing with the blowing rate adjusted to an optimal value for flow uniformity. Heat transfer augmentation above the zeroturbulence case ranged from 37 to 53 percent for the test cylinder behind the jet grid for a cylinder Reynolds number range of 48,000 to 180,000, respectively. The level of heat transfer augmentation was found to be fairly uniform with respect to circumferential distance from the stagnation line. Stagnation point heat transfer results (expressed in terms of the Frossling number) were found to be somewhat low with respect to previous studies, when compared on the basis of equal values of the parameter Tu Re(1/2), indicating an additional Reynolds number effect as observed by previous investigators. Consequently, for a specified value of Tu Re(1/2), data obtained with a relatively high turbulence intensity will have a lower value of the Frossling number.

Obrien, J. E.↗

Direct simulation of stagnation streamline flow for hypersonic reentry

The direct simulation Monte Carlo (DSMC) method is applied to simulate one-dimensional flow along the stagnation streamline. The freestream conditions considered are those encountered by the nose region of the Space Shuttle Orbiter during the hypersonic reentry. The range of altitudes (75 to 92 km) considered in the present calculations covers continuum to the less rarefied portion of the transition flow regime. The calculations account for thermal as well as the chemical nonequilibrium effects. The attention is focused on the flow structure along the stagnation streamline for different specified shock locations at a given altitude. The effect of shock location on the stagnation-point gas composition and heat transfer is analyzed for specific altitude; consequently, these results are appropriate for hemispherical bodies with different nose radii. Finally, comparison is made between the present DSMC results and the viscous shock-layer calculations, which show good agreement at the lowest altitude.

Dogra, Virendra K.↗

Unsteady stagnation-point heat transfer during passage of a concentrated vortex

The unsteady boundary layer due to a single rectilinear vortex filament approaching a 2-D stagnation point is investigated. Assuming the vortex remains far from the surface, incompressible potential flow theory is used to determine the time dependent inviscid flow field. The unsteady boundary layer equations are solved by an alternating-direction-implicit finite-difference method. Two mechanisms which cause fluctuations in heat transfer are the unsteady velocity field in the boundary layer and secondly, the unsteady total temperature at the edge of the boundary layer. The relative importance of these mechanisms is dependent upon the total temperature fluctuations relative to the imposed temperature difference. As a vortex approaches a stagnation point it may be forced to one side of the stagnation line or the other, depending on its initial position. Results are presented for both of these cases.

Rigby, David L.↗

Effect of nose shape on three-dimensional stagnation region streamlines and heating rates

A new method for calculating the three-dimensional inviscid surface streamlines and streamline metrics using Cartesian coordinates and time as the independent variable of integration has been developed. The technique calculates the streamline from a specified point on the body to a point near the stagnation point by using a prescribed pressure distribution in the Euler equations. The differential equations, which are singular at the stagnation point, are of the two point boundary value problem type. Laminar heating rates are calculated using the axisymmetric analog concept for three-dimensional boundary layers and approximate solutions to the axisymmetric boundary layer equations. Results for elliptic conic forebody geometries show that location of the point of maximum heating depends on the type of conic in the plane of symmetry and the angle of attack, and that this location is in general different from the stagnation point. The new method was found to give smooth predictions of heat transfer in the nose region where previous methods gave oscillatory results.

Hassan, Basil↗

Flight evaluation of a stagnation detection hot-film sensor

Results are presented of flight evaluation tests of a stagnation detection hot-film sensor. Experiments were conducted at steady level-flight conditions over a range of altitudes, angles of attack, and air speeds, as well as quasi-steady conditions during level-flight velocity acceleration and deceleration maneuvers. The results demonstrate the ability of a hot-film sensor to provide an accurate, reliable, and relatively nonintrusive measurement of the stagnation region in a flight environment. Stagnation could be identified within 0.1 inches.

Scott, Michael A.↗