Search NASA⌕ Search

SEARCH · Search NASA

Results for “STARTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

A parametric study of motor starting for a 2- to 10-kilowatt Brayton power system

A study of the motor starting of a Brayton cycle power system was conducted to provide estimates of system sensitivity to several controllable parameters. These sensitivity estimates were used as a basis for selection of an optimum motor-start scheme to be implemented on the 2- to 10-kilowatt Brayton power system designed and presently under test. The studies were conducted with an analog simulation of the Brayton power system and covered a range of frequencies from 400 Hz (33 percent design) to 1200 Hz (design), voltage-to-frequency ratios of 0.050 (50 percent design) to 0.100 (design), turbine-inlet temperatures of 800 K (1440 R, 70 percent design) to 1140 K (2060 deg R, design), and prestart pressure levels of 14.5 psia to 29.0 psia. These studies have shown the effect of selected system variables on motor starting. The final selection of motor-start variables can therefore be made on the basis of motor-start inverter complexity, battery size and weight, desired steady-state pressure level after startup, and other operational limitations. In general, the study showed the time required for motor starting to be inversely proportional to motor frequency, voltage, turbine-inlet temperature, and pressure level. An increase in any of these parameters decreases startup time.

Cantoni, D. A.↗

Arcjet starting reliability: A multistart test on hydrogen/nitrogen mixtures

An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets onboard a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hrs. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.

Haag, Thomas W.↗

Arcjet starting reliability - A multistart test on hydrogen/nitrogen mixtures

An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets on board a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hr. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.

Haag, Thomas W.↗

Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

Appelbaum, Joseph↗

Start-On-The-Part Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

Fabrication of a complex part by automated tape placement (ATP) can require starting up a new tape-end in the part interior, termed start-on-the-part. Careful thermal management of the starting transient is needed to achieve uniform crystallinity and inter-laminar weld strength - which is the objective of this modeling effort. The transient is modeled by a Fourier-Laplace transform solution of the time-dependent thermal transport equation in two spatial dimensions. The solution is subject to a quasi-steady approximation for the speed and length of the consolidation head. Sample calculations are done for the Langley ATP robot applying PEEK/carbon fiber composite and for two upgrades in robot performance. The head starts out almost at rest which meets an engineering requirement for accurate placement of the new tape-end. The head then rapidly accelerates until it reaches its steady state speed. This rapid acceleration, however, violates the quasi-steady approximation, so uniform weld strength and crystallinity during the starting transient are not actually achieved. The solution does give the elapsed time and distance from start-up to validity of the quasi-steady approximation - which quantifies the length of the non-uniform region. The elapsed time was always less than 0.1 s and the elapsed distance less than 1 cm. This quantification would allow the non-uniform region to be either trimmed away or compensated for in the design of a part. Such compensation would require experiments to measure the degree of non-uniformity, because the solution does not provide this information. The rapid acceleration suggests that the consolidation roller or belt be actively synchronized to avoid abrading the tape.

Costen, Robert c.↗

Effects of Gravity on Start-up of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper describes an experimental study on the effect of gravity on the start-up of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. Each evaporator has an outer diameter of 9 mm and has its own integral compensation chamber (CC). The MLHP was placed under five configurations where the relative elevation and tilt among the loop components were varied. The four well-known initial conditions between the evaporator and CC prior to the LHP start-up were created in this experimental study through combinations of: 1) the test configuration; 2) the method of preconditioning the loop prior to start-up, and 3) the heat load distribution among the evaporators. A total of 165 start-ups were conducted under the five test configurations. All of these start-ups were successful. However, the effect of gravity on start-up transients was clearly seen under otherwise the same heat load distribution and sink temperatures. An analytical model was used to simulate the MLHP transient behaviors, and the model predictions agreed very well with the experimental results.

Ku, Jentung↗

Evaluation of Start Transient Oscillations with the J-2X Engine Gas Generator Assembly

During development of the gas generator for the liquid oxygen/liquid hydrogen propellant J-2X rocket engine, distinctive and oftentimes high-amplitude pressure oscillations and hardware vibrations occurred during the start transient of nearly every workhorse gas generator assembly test, as well as during many tests of engine system hardware. These oscillations appeared whether the steady-state conditions exhibited stable behavior or not. They occurred similarly with three different injector types, and with every combustion chamber configuration tested, including chamber lengths ranging over a 5:1 range, several different nozzle types, and with or without a side branch line simulating a turbine spin start gas supply line. Generally, two sets of oscillations occurred, one earlier in the start transient and at higher frequencies, and the other almost immediately following and at lower frequencies. Multiple dynamic pressure measurements in the workhorse combustion chambers indicated that the oscillations were associated with longitudinal acoustic modes of the combustion chambers, with the earlier and higher frequency oscillation usually related to the second longitudinal acoustic mode and the later and lower frequency oscillation usually related to the first longitudinal acoustic mode. Given that several early development gas generator assemblies exhibited unstable behavior at frequencies near the first longitudinal acoustic modes of longer combustion chambers, the start transient oscillations are presumed to provide additional insight into the nature of the combustion instability mechanisms. Aspects of the steadystate oscillations and combustion instabilities from development and engine system test programs have been reported extensively in the three previous JANNAF Liquid Propulsion Subcommittee meetings (see references below). This paper describes the hardware configurations, start transient sequence operations, and transient and dynamic test data during the start transient. The implications of these results on previous analyses and understanding of the combustion instability observed during steady-state conditions, especially the effects of injector influences, is discussed.

Hulka, J. R.↗

Black-Starting Microgrids Using Inverter-Based Distributed Energy Resources

Recent trends in power systems show increasing deployment of inverter-based distributed energy resources (DERs) at the distribution level. Efforts have also been made to use inverter-based DERs for system restoration of critical sections of distribution feeders. In the past few years, there has been active consideration of using local grid-forming (GFM) DERs, which can form their own voltage and frequency, to black-start microgrids instead of waiting for the bulk system for supply restoration. However, using current-limited inverter-based DERs for black-start operations with high inrush currents can pose some technical challenges. This paper presents detailed electromagnetic transient studies on a digital real-time simulator to assess the operational feasibility of using local inverter-based GFM DERs for microgrid black-start operations as a bottom-up approach instead of a top-down approach where the substation is used to restore critical sections of the feeder. The paper presents key modeling details for distribution system components for studying GFM DER-based microgrid black-start operations. The paper presents simulation results comparing different black-start approaches using GFM DERs for two test systems: i) a simple test microgrid and ii) a real-world utility microgrid currently being designed and deployed by Holy Cross Energy in Colorado.

black start↗

Survival and behavior of Mojave desert tortoises head-started with and without outdoor rearing

Mojave desert tortoise (Gopherus agassizii) populations in some regions have declined by >50% since 2004, prompting the need for more research on ways to recover populations. One possible recovery tool is head-starting (i.e., the act of protecting and raising juvenile tortoises to sizes that increase survival upon release); however, head-starting can have high start-up and maintenance costs that can limit its feasibility. Strategies that reduce cost and rearing duration may foster broader and more effective use. We released and radio-tracked 60 juvenile tortoises in the Mojave National Preserve in California, USA, that had been reared under 2 treatments: those reared 1 year indoors after hatching, then 1 year outdoors (combo) and those reared just 1 year indoors (indoor-only). We tested whether indoor-only rearing alone could be a more efficient means of producing robust head-started tortoises. We examined the behavior, movement, and survival of tortoises after release into the wild from 2020 to 2021 to determine whether these outcomes differed between husbandry treatments. Combo tortoises tended to perform settling behaviors (mean ± 1 SE days to building first burrow = 6.7 ± 0.8, entering dormancy = 23.3 ± 2.1, and emerging from dormancy = 189.6 ± 4.4) earlier than indoor-only tortoises (7.4 ± 0.9, 31.5 ± 2.6, and 193.9 ± 5.9, respectively), but this difference was not significant, suggesting the rearing method did not greatly alter settling behavior. Indoor-only tortoises dispersed at least twice as far from their release site (156.2 ± 26.3 m compared with 77.3 ± 20.6 m for combo tortoises), had larger mean use areas (3.7 ± 0.1 ha compared with 2.8 ± 0.3 ha for combo tortoises for 95% Brownian bridge movement model estimates), and greater variability in their movements than combo tortoises (daily average step length post-emergence: 4.3 ± 0.2 m compared with 2.8 ± 0.1 m for combo tortoises). Despite differences in their movements, indoor-only and combo tortoises had similar survival rates over the study, 51% versus 42%, respectively, during a period of extreme drought in 2021. The similarity in survival between groups gives head-starting practitioners freedom in their rearing methods. The indoor-only group had lower site fidelity, which should be considered when this is an undesirable trait for released tortoises.

60 APPLIED LIFE SCIENCES↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Characterization of commercial vehicles’ start-up operations from in-use data

Diesel engines produce disproportionate levels of emissions when the engine and after-treatment systems are operating at low temperatures. This situation arises most commonly when the vehicle is first started after overnight. To quantify emissions attributable to vehicle starts, a sizable collection of on-road commercial vehicle operating data is analyzed to identify start-up events and inspect associated emissions. Data was obtained from the National Renewable Energy Laboratory’s (NREL’s) Fleet DNA and from the Center for Environmental Research & Technology (CE-CERT). Included are 500 + diesel vehicles with more than 42,000 recorded days, drawn from 25 vocational categories across the United States. Analysis shows that vehicle behavior, in terms of engine cold- and warm-operation, starts per day, soak time, and warm-up duration, differs significantly between vehicle vocations. Also, weighting factors for cold- and hot-starts currently used in the U.S. Environmental Protection Agency’s Federal Test Procedure (FTP) for heavy-duty emissions certification accurately represent real-world operations. Although the FTP includes a comparable fraction of cold operation, the hot fraction is much shorter than real-world operation due to limited test duration. The investigation also revealed that real-world engines operate for a significant amount of time when the engine coolant is in the “hot-stabilized” region, but the selective catalytic reduction (SCR) temperature is below its effective operating temperature of 200 °C. Of the vehicles under investigation, almost 20% of their operational time is within this condition. Therefore, novel approaches to raise and maintain SCR temperature are highly required to further reduce engine emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Efficient ECCD non-inductive plasma current start-up, ramp-up, and sustainment for an ST fusion reactor

The elimination of the need for an Ohmic heating solenoid may be the most impactful design driver for the realization of economical compact fusion tokamak reactor systems. However, this would require fully non-inductive start-up and current ramp-up from zero plasma current and low electron temperature of sub-keV to the full plasma current of ~10–15 MA at 20–30 keV electron temperature. To address this challenge, an efficient solenoid-free start-up and ramp-up scenario utilizing a low-field-side-launched extraordinary mode at the fundamental electron cyclotron harmonic frequency (X–I) is proposed, which has more than two orders of magnitude higher electron cyclotron current drive (ECCD) efficiency than the conventional ECCD for the sub-keV start-up regime. A time dependent model was developed to simulate the start-up scenarios. For the Spherical Tokamak Advanced Reactor (STAR) (Menard et al 2023 Next-Step Low-Aspect-Ratio Tokamak Design Studies (IAEA)), it was found that to fully non-inductively ramp-up to 15 MA, it would take about 25 MW of EC power at 170 GHz. Because of the relatively large plasma volume of STAR, radiation losses must be considered. It is important to make sure that high Z impurities are kept sufficiently low during the early current start-up phase where the temperature is sub-keV range. Since the initial current ramp up takes place at a factor of ten lower density compared to the sustained regimes, it is important to transition into a higher bootstrap fraction discharge at lower density to minimize the ECCD power requirement during the densification. For the sustainment phase an array of eight gyrotron launchers with a total of about 60 MW of fundamental O-mode was found to be sufficient to provide the required axis-peaked external current drive. High efficiencies between 19–57 kA MW –1 were found with optimal aiming, and these were resilient to small changes in aiming angles and density and temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of corporate investment in start-ups for climate-tech innovation

Enabling and accelerating the full potential of energy innovation is a critical component of the global policy response to climate change. Incentivizing start-ups advancing climate-tech (i.e., products and services related to clean energy and climate change), has become central to innovation policy because start-ups are nimble (compared to incumbents), can quickly focus on bringing new technologies to market, and simultaneously create new jobs and catalyze local industries. Public policies to support climate-tech start-ups and efforts such as Mission Innovation tend to focus on increasing government spending (e.g., grants for research and development) or on creating demand pull for new technologies (e.g., feed-in-tariffs). But to go from research and development to widespread adoption of new products and services, start-ups need to grow and scale, and this requires support from private investors. Yet, research on how different investors can shape the direction of climate innovation—and how public policy can incentivize private investment in climate-tech start-ups to support the public good—is surprisingly sparse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Black Start with Inverter-Based Resources: Hardware Testing

Black start, or grid restoration after a wide-spread power outage, is a critical service on the power system that has historically been provided by transmission-connected synchronous generators. As the power system transitions to rely on more distributed and inverter-based resources it will be critical that these resources can also provide black start services. In this work we investigated battery energy storage and solar photovoltaics technical capabilities and limitations to provide black start services through hardware testing in an experimental microgrid testbed. This hardware demonstration of inverter-based resources providing black start functions can help inform grid operators on how to include these types of resources in their black start plans.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MSTL Re-Start Phase 1.5 Project Final Report

This document provides an overview of re-start efforts at Sandia National Laboratories (SNL), National Solar Thermal Test Facility (NSTTF), for the SNL Molten Salt Test Loop (MSTL). MSTL is one of the world’s only industrial-scale molten salt test systems, capable of testing commercial-scale thermal hydraulic equipment at an industrial scale, required for confident bankability of products. This work was facilitated as part of the Phase 1 re-start effort for facilitating forensics assessments to inform final refurbishments and upgrades costs and schedule information for revitalizing MSTL for use during a separate Phase 2 effort. This work was facilitated to further de-risk a Phase 2 effort pertaining to the tank and the pump, which were considered during Phase 1 to be high-risk items for a successful re-start. Impact from a successful re-start will allow SNL and other industrial molten salt systems companies, such as those in the Market Utilization Report provided in the Phase 1 submission package. An objective of this document is to also ensure longevity of utilization of MSTL after re start.

14 SOLAR ENERGY↗

The Effect of Spark-Plug Heat Dispersal Range and Exhaust Valve Opening Timing on Cold-Start Emissions and Cycle-to-Cycle Variability

The partnership for advancing combustion engines (PACE) is a US Department of Energy consortium involving multiple national laboratories and includes a goal of addressing key efficiency and emission barriers in light-duty engines fueled with a market-representative E10 gasoline. A major pillar of the initiative is the generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster light-off of the three-way catalyst and engine out emissions during that period. In this study, gaseous and soot emissions were measured at a distance representative of the three-way catalyst position downstream of the engine at a 2 bar net indicated mean effective pressure (NIMEP) steady-state operating condition representative of cold-start. The test matrix included sweeps of ignition timing 15 degrees-before to 10 degrees-after top dead center firing (TDCf) across three different spark-plug heat dispersal ranges (HR). Additionally, the effect of varying exhaust valve opening (EVO) timing on combustion stability and emissions was also studied. Results show that the spark plug HR affects the coefficient of variation (COV) of NIMEP under all cold-start conditions, while the impact on emissions was found to be minimal. At very retarded spark timings, colder spark plugs required higher air and fuel flow to maintain the desired 2bar NIMEP load, but the fraction of fuel energy going into the exhaust was found to be similar for all spark plugs. Finally, retarding exhaust valve timings showed a simultaneous reduction in emissions while increasing the fraction of fuel energy being fed into the exhaust. However, engine COV was also observed to increase with retarded exhaust timings.

42 ENGINEERING↗

Auto Stop-Start Fuel Consumption Benefits

With increasingly stringent regulations mandating the improvement of vehicle fuel economy, automotive manufacturers face growing pressure to develop and implement technologies that improve overall system efficiency. One such technology is an automatic (auto) stop-start feature. Auto stop-start reduces idle time and reduces fuel use by temporarily shutting the engine off when the vehicle comes to a stop and automatically re-starting it when the brake is released, or the accelerator is pressed. As mandated by the U.S. Congress, the U.S. Environmental Protection Agency (EPA) is required to keep the public informed about fuel saving practices. This is done, in partnership with the U.S. Department of Energy (DOE), through the fueleconomy.gov website. The “Fuel-Saving Technologies” and “Gas Mileage Tips” sections of the website are focused on helping the public make informed purchasing decisions and encouraging fuel-saving driving habits. Here, in order to provide users with accurate information about the auto stop-start feature, experiments were conducted to determine its fuel economy effect. Four vehicles were tested both with and without the feature enabled under three test cycles: the Federal Test Procedure (FTP) city fuel economy test, the US06 high acceleration aggressive driving schedule that is often identified as the “Supplemental FTP” driving schedule, and the EPA New York City Cycle (NYCC). The results were compared to measure the fuel economy and consumption effects of using the auto stop-start feature. It was found that the fuel economy improvement varied significantly between drive cycles depending on the amount and percentage of idle time during the test. The largest fuel economy improvements were 7.27% and 26.4% for the FTP and NYCC, respectively.

33 ADVANCED PROPULSION SYSTEMS↗