Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation

Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Development of a Theoretical Monitoring System Design for a HLW Repository Based on the 'MoDeRn Monitoring Workflow' (A Case Study) - 12044

In this paper, a generic German disposal concept in rock salt is used as an example to discuss the design of a repository monitoring system. The approach used is based on a generic structured approach to monitoring - the MoDeRn Monitoring Workflow - which is being developed and tested as part of an on-going European Commission Seventh Framework project. As a first step in the study, the requirements on the monitoring program were identified through consideration of the national context, including regulatory guidelines, host rock properties and waste to be disposed of. These are stated as general monitoring objectives. An analysis of the German safety concept for safe confinement of the radioactive waste allows these general objectives to be converted into specific sub-objectives, and for the sub-objectives to be related to specific monitoring processes and parameters. The safety concept identified the key safety components, each of them having specific associated safety functions. The safety functions can be related to the list of features, events and processes (FEPs) that contains all processes related to the future repository evolution. By screening the FEP list, all processes that potentially can affect the safety functions have been identified. In a next step the parameters that would be affected by the individual processes were determined, leading to a preliminary list of parameters to be monitored. By evaluating available techniques and monitoring equipment, this preliminary list was investigated with respect to its technical feasibility at the intended locations. Prior to final system selection, potential impacts of the monitoring system on safety or other measurements are evaluated. To avoid potential pathways for fluids that may compromise the integrity of a barrier, considerations on the application of wireless data transmission systems and techniques for autonomous, long-term power supply were given. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-251: Developing a Daily Proton Beam Monitoring System

Purpose: To develop a daily monitoring system for proton beam output check and beam uniformity check. Methods: Designed for continuously irradiated photon and electron beams with a field size of 20 cm x 20 cm, the daily output checker (Sun Nuclear, Inc.) is not suitable for monitoring proton beams with inter-pulse beam-off and a field size smaller than 14–16 cm in diameter. To allow such proton beam monitoring, the following tests were performed. 1. Absolute dose and array calibrations which accept continuous irradiation only, were performed using photon beams. 2. Five ion chambers within the central area of 8 cm x 8 cm were utilized to check constancy of output at the center of beam modulation and at distal edge and to check beam symmetry and flatness. 3. To simplify our evaluation, the array calibration was manually modified, such that all five chambers report equal values in spite of their differences in build-up thicknesses. 4. The chamber at the lower-right corner is placed under a buildup thickness that can offer dose measurement at the distal edge. This buildup thickness was determined by proton beam range measurements, which established buildup thickness for beam output measurement at the central chamber and range measurement at the corner chamber. 5. The beam-off delay which allows receipt of pulsed irradiation was activated and optimal delay times were determined for each proton beam at 149.6, 185.6, and 249.5 MeV. Results: The above system was tested by miss-steering proton beams and altering phantom thickness by 1 mm at a time. The system reliably monitored the beam with: 3% tolerance for beam flatness, symmetry and output. The range difference of 0.5 mm could be detected at all energies by setting a tolerance of 20%. Conclusion: A quick daily proton beam monitoring system was feasible.

07 ISOTOPE AND RADIATION SOURCES↗

Milliwave melter monitoring system

A milliwave melter monitoring system is presented that has a waveguide with a portion capable of contacting a molten material in a melter for use in measuring one or more properties of the molten material in a furnace under extreme environments. A receiver is configured for use in obtaining signals from the melt/material transmitted to appropriate electronics through the waveguide. The receiver is configured for receiving signals from the waveguide when contacting the molten material for use in determining the viscosity of the molten material. Other embodiments exist in which the temperature, emissivity, viscosity and other properties of the molten material are measured.

47 OTHER INSTRUMENTATION↗

Fission Gas Monitoring System Efficiency Calibration Summary Report

The Fission Gas Monitoring System was designed to work in conjunction with the Fuel Accident Condition Simulator Furnace and is used to measure fission gas releases during post-irradiation fuel heating tests. A high-purity helium sweep gas is swept past the heated fuel sample in the furnace and routed to a fission gas monitoring system, which cryrogenically traps the krypton (Kr) and xenon (Xe) fission gases. As the radioactive species of the trapped gas decays, high-purity germanium detectors monitor the amount of fission gas in each trap. The primary fission product present in this test is 85Kr, which has a 10.76-year half-life. The presence of 85Kr indicates particle defects and iodine release. There is also the potential for re-irradiating the fuel compacts in the Neutron Radiography Reactor in the Hot Fuel Examination Facility basement. With re-irradiation, it is possible to have xenon fission gas present, specifically 133Xe, which has a 5.243-day half-life. Re-irradiation also produces 131I, which is important for design-basis accidents and regulatory licensing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant

Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using simulation to evaluate warhead monitoring system effectiveness

There is a need to develop and demonstrate technical approaches for verifying potential future agreements to limit and reduce total warhead stockpiles. To facilitate this aim, warhead monitoring systems employ both concepts of operations (CONOPS) and technologies. A systems evaluation approach can be used to assess the relative performance of CONOPS and technologies in their ability to achieve monitoring system objectives which include: 1) confidence that a treaty accountable item (TAI) initialized by the monitoring system is as declared; 2) confidence that there is no undetected diversion from the monitoring system; and 3) confidence that a TAI is dismantled as declared. Although there are many quantitative methods that can be used to assess system performance for the above objectives, this paper focuses on a simulation perspective primarily for the ability to support analysis of the probabilities that are used to define operating characteristics of CONOPS and technologies. This paper describes a discrete event simulation (DES) model, comprised of three major sub-models: including TAI lifecycle flow, monitoring activities, and declaration behavior. The DES model seeks to capture all processes and decision points associated with the progressions of virtual TAIs, with notional characteristics, through the monitoring system from initialization through dismantlement. The simulation updates TAI progression (i.e., whether the generated test objects are accepted and rejected at the appropriate points) all the way through dismantlement. Evaluation of TAI lifecycles primarily serves to assess how the order, frequency, and combination of functions in the CONOPS affect system performance as a whole. It is important, however, to note that discrete event simulation is also capable (at a basic level) of addressing vulnerabilities in the CONOPS and interdependencies between individual functions as well. This approach is beneficial because it does not rely on complex mathematical models, but instead attempts to recreate the real world system as a decision and event driven simulation. Finally, because the simulation addresses warhead confirmation, chain of custody, and warhead dismantlement in a modular fashion, a discrete-event model could be easily adapted to multiple CONOPS for the exploration of a large number of “what if” scenarios.

Perkins, Casey J.↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Experience on Safety Review of Liquid and Gaseous Effluent Monitoring System for Nuclear Power Plants in Korea - 16237

The liquid and gaseous effluent monitoring systems are important components in order to evaluate and minimize the radiation environmental impacts from Nuclear Power Plants (NPPs). Therefore, licensee should install liquid and gaseous effluent monitoring systems and these systems should be reviewed by regulatory body. In Korea, the criteria of liquid and gaseous effluent monitoring systems for NPPs are stipulated in Nuclear Safety Act (NSA) and subordinate statute, and it is stated in 'Regulation on Technical Standards for Nuclear Reactor Facilities, etc.' that 'Instrumentation shall be provided to monitor related variables, including the following, and systems over their anticipated ranges of normal operations, anticipated operational occurrences, and accident conditions'. RG-1.97(Rev. 3, 1983) of US Nuclear Regulatory Commission (NRC) was used as criterion for accident monitoring instrumentations for NPPs in Korea. Licensee, however, started to apply RG-1.97(Rev. 4, 2006) as new criterion for accident monitoring instrumentation of the Construction Permit (CP) of new NPPs (Shin-kori Unit 5 and 6). Licensee submitted the report for type selection criteria and this report shows selection criteria of from 'Type A variables' to 'Type E variables'. Licensee of Korea has plans to submit the validation report regarding the criteria for accident monitoring instrumentation during Operation License (OL) and regulatory body of Korea also will conduct safety review of these reports. A graded approach to establishing a sampling program is required in ANSI/HPS N13.1-1999. Because deaerator release pipe of Shin-kori unit 5, 6 was integrated into condenser vacuum system release pipe, regulatory body reviewed application of a graded approach on this integration. Output of PWR GALE shows that iodine released from turbine building is 0.12% of total iodine release amount and this value is potential impact categories (PICs) 3 in ANSI/HPS N13.1-1999. So, periodic sampler installed in condenser vacuum system release pipe in Shin-kori unit 5, 6 is suitable. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Documentation pckage for the RFID temperature monitoring system (Of Model 9977 packages at NTS).

The technical basis for extending the Model 9977 shipping package periodic maintenance beyond the one-year interval to a maximum of five years is based on the performance of the O-ring seals and the environmental conditions. The DOE Packaging Certification Program (PCP) has tasked Argonne National Laboratory to develop a Radio-Frequency Identification (RFID) temperature monitoring system for use by the facility personnel at DAF/NTS. The RFID temperature monitoring system, depicted in the figure below, consists of the Mk-1 RFId tags, a reader, and a control computer mounted on a mobile platform that can operate as a stand-alone system, or it can be connected to the local IT network. As part of the Conditions of Approval of the CoC, the user must complete the prescribed training to become qualified and be certified for operation of the RFID temperature monitoring system. The training course will be administered by Argonne National Laboratory on behalf of the Headquarters Certifying Official. This is a complete documentation package for the RFID temperature monitoring system of the Model 9977 packagings at NTS. The documentation package will be used for training and certification. The table of contents are: Acceptance Testing Procedure of MK-1 RFID Tags for DOE/EM Nuclear Materials Management Applications; Acceptance Testing Result of MK-1 RFID Tags for DOE/EM Nuclear Materials Management Applications; Performance Test of the Single Bolt Seal Sensor for the Model 9977 Packaging; Calibration of Built-in Thermistors in RFID Tags for Nevada Test Site; Results of Calibration of Built-in Thermistors in RFID Tags; Results of Thermal Calibration of Second Batch of MK-I RFID Tags; Procedure for Installing and Removing MK-1 RFID Tag on Model 9977 Drum; User Guide for RFID Reader and Software for Temperature Monitoring of Model 9977 Drums at NTS; Software Quality Assurance Plan (SQAP) for the ARG-US System; Quality Category for the RFID Temperature Monitoring System; The Documentation Package for the RFID Temperature Monitoring System; Software Test Plan and Results for ARG-US OnSite; Configuration Management Plan (CMP) for the ARG-US System; Requirements Management Plan for the ARG-US System; and Design Management Plan for ARG-US.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Process control monitoring systems, industrial plants, and process control monitoring methods

A system comprises a valve; a plurality of RFID sensor assemblies coupled to the valve to monitor a plurality of parameters associated with the valve; a control tag configured to wirelessly communicate with the respective tags that are coupled to the valve, the control tag being further configured to communicate with an RF reader; and an RF reader configured to selectively communicate with the control tag, the reader including an RF receiver. Other systems and methods are also provided.

Skorpik, James R↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Ensuring Safety of Hydraulic Equipment at the Votkinsk Hydroelectric Power Plant with an Automated Diagnostic Monitoring System

Experience with the use of an automated diagnostic monitoring system for the technical condition and safety of concrete structures at the Votkinsk HPP is discussed. The automated system for monitoring the state of the hydraulic engineering systems has been developed to increase the accuracy, reliability, and efficiency of the data from instrumental observations during operation of the plant.

42 ENGINEERING↗

Assembly and characterization of fast neutron detectors for TREAT fuel motion monitoring system

The TREAT fuel motion monitoring system (FMMS) currently uses a fast neutron hodoscope which allows for fast neutron imaging produced by fission in the reactor core. These neutrons are then passed unmoderated through a core slot and collimated to the 360 detector array, or hodoscope. The purpose of this project was to assemble, characterize, and qualify another 96 PMT’s to add to the current batch of 96. The assembly consists of four main components starting with a PMT, a voltage divider, a PRS button that will scintillate when struck by neutrons, and a Phenolic shroud which will house all the components to create a standard form factor. The characterization will be completed in the lab to reach the goal of having all PMT’s characterized with a determination of operability before finalized and placed inside the TREAT hodoscope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation portal monitor system and method

A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

47 OTHER INSTRUMENTATION↗

Implant Angle Monitor System of MC3-II

Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.