Search NASASearch

SEARCH · Search NASA

Results for “SYSTEM STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Vibration Isolation and Stabilization System for Spacecraft Exercise Treadmill Devices

A novel, passive system has been developed for isolating an exercise treadmill device from a spacecraft in a zero-G environment. The Treadmill 2 Vibration Isolation and Stabilization System (T2-VIS) mechanically isolates the exercise treadmill from the spacecraft/space station, thereby eliminating the detrimental effect that high impact loads generated during walking/running would have on the spacecraft structure and sensitive microgravity science experiments. This design uses a second stage spring, in series with the first stage, to achieve an order of magnitude higher exercise- frequency isolation than conventional systems have done, while maintaining desirable low-frequency stability performance. This novel isolator design, in conjunction with appropriately configured treadmill platform inertia properties, has been shown (by on-orbit zero-G testing onboard the International Space Station) to deliver exceedingly high levels of isolation/ stability performance.

Fialho, Ian

A model following variable stability system for the NASA ARC X-14B.

A description of the basic design concept, hardware design, and flight evaluation of a Variable Stability System (VSS) installed on the NASA ARC X-14B is presented. The NASA ARC X-14B is a twin-engine, single-seated VTOL aircraft. The VSS is unique in that it employs a general purpose airborne digital computer as an integral part of the hybrid model following flight control system. The system design, analysis and testing phases are discussed in the paper from the application of optimal control techniques in the preliminary design of the system, through the flight demonstration of the VSS hardware.

Gallagher, J. T.

Coding Structures for Seated Row Simulation of an Active Controlled Vibration Isolation and Stabilization System for Astronaut’s Exercise Platform

Simulation for seated aerobic row exercise was a continued task to assist NASA in analyzing a one-dimensional vibration isolation and stabilization system for astronaut’s exercise platform. Feedback delay and signal noise were added to the simulation model. Simulation runs for this study were conducted in two software simulation tools, Trick and MBDyn, software simulation environments developed at the NASA Johnson Space Center. The exciter force in the simulation was calculated from motion capture of an exerciser during a seated aerobic row exercise. The simulation runs include passive control, active control using a Proportional, Integral, Derivative (PID) controller, and active control using a Piecewise Linear Integral Derivative (PWLID) controller. Output parameters include displacements of the exercise platform, the exerciser, and the counterweight; transmitted force to the wall of spacecraft; and actuator force to the platform. The simulation results showed excellent force reduction in the active controlled system compared to the passive controlled system, which resulted in less force reduction.

Simulation

Teal Cycle Ergometer Vibration Isolation and Stabilization System Human-in-the-Loop Ground Evaluation for Long-Duration Spaceflight

Purpose: To counter the deleterious effects of weightlessness on the cardiopulmonary system, astronauts living on the International Space Station exercise on a variety of countermeasure equipment including the Cycle Ergometer Vibration Isolation and Stabilization System (CEVIS). Operational since 2001, the onboard CEVIS will be replaced by a new model, known as Teal CEVIS (TC). As a part of ground evaluation, TC hardware underwent human-in-the-loop (HITL) testing to verify the TC hardware produces workloads that elicit physiologic responses comparable to a laboratory cycle ergometer (LAB). Methods: Seven subjects (5 M/2 F) performed submaximal cycle ergometer testing with indirect calorimetry measures on TC and LAB on separate test days. Testing consisted of graded 30 watt increases in workload until subjects reached 85% of age-predicted max heart rate (HR). Exercise outcomes included rate of oxygen uptake (VO2; liters/min), rate of energy expenditure (REE; kcal/min), and HR (beats/min). Linear mixed models (LMM) were fitted to compare VO2, REE, and HR responses between devices across power outputs with fixed effects for power (P) and device (D) and with random effects for subject. LMM effect coefficients (β), std errors (SE), pseudo-partial R2 of effects (pR2), and model likelihood ratio statistics (χ2, Pr(> chisq); α<.05) are provided. Results: LMM main effects for P and D were observed for VO2 (βp=.0107, SE = .0002, pR2=0.97; βd = -0.075, SE = 0.019, pR2=0.14; χ2(1)= 13.57, p<.001), such that VO2 was higher across stages on TC. Main effects of P and D were observed for REE (βp= .0586, SE = 0.001, pR2= 0.97; βd = -0.33208, SE = 0.099, pR2= 0.056; χ2(1)=10.481, p < .01), such that REE was higher across power outputs on TC. A P x D interaction was observed for HR, along with main effects for P and D (βp x d =-0.048, SE = 0.02, pR2=0.048; βp= 0.42, SE = 0.016, pR2=0.87; χ2(1) = 5.398, p = 0.02), such that higher workloads elicited a greater difference in HR between devices. Conclusions: HITL results show, TC elicits greater physiologic responses across power outputs compared to LAB. However, pR2 for device effects show small differences between devices. Therefore, TC can be expected to provide appropriate physiological stimulus across workloads and be considered a reliable tool to mitigate the effects of weightlessness.

Cycle Ergometer Vibration and Isolation System

Implementing a Laser Stabilization System for Trapping Ca+ Ions: an Internship Reflection

At Lawrence Livermore National Laboratory, I contributed to a project developing 3D printed micro ion traps for quantum computing. I designed, implemented, and assessed a laser stabilization system that locked lasers to the frequencies required for calibrating our High Finesse WS8-10 wavelength meter and for laser cooling and trapping of Ca+ ions. I also programmed a Python interface for hardware communication, data collection, and statistical analysis. Additionally, I optimized and aligned laser beam paths, and I implemented a closed digital feedback loop using Proportional, Integral, and Derivative (PID) control parameters. I analyzed both the long-term and short-term behavior of our locked lasers and adjusted PID parameters to enhance performance. Furthermore, I used COMSOL to simulate the capacitance of a linear Paul trap design and predict our trap’s performance. The procedures I developed for the interface, analysis, and simulations will continue to support the ion trapping experiment after my appointment. I strengthened my skills in data analysis, Python coding, and optical alignment for laser systems. My confidence as a researcher grew, particularly in communicating my research. This experience taught me the importance of careful planning and consideration in research and solidified my desire to continue exploring novel quantum technology as an undergraduate

42 ENGINEERING

Performance of an Active Vehicle Stabilization System During Touchdown in the Presence of Propellant Slosh Dynamics

This paper characterizes the effect of propellant slosh on the performance of an active stabilization control system for the two-two-and-over symmetric landing mode during touchdown. Generalized impulse and momenta theory is used to model the instance when the landing leg strikes the ground as an inelastic collision event. For active stabilization, a rate damping controller is used to stabilize the attitude of the vehicle via onboard reaction control system. Simulation results are shown comparing the performance of the control system with and without slosh dynamics.

Jing Pei

A movable-mass attitude stabilization system for cable-connected artificial-g space stations

The development of an active, momentum-exchange system to be used for attitude stabilization of a class of cable-connected artificial-g space stations is studied. A system which employs a single movable control mass is examined for the control of a space station which has the physical appearance of two cylinders connected axially by cables. The dynamic model for the space station includes its aggregate rigid body rotation and relative torsional rotation between the bodies. A zero torsional stiffness design (one cable) and a maximum torsional stiffness design (eight cables) are examined in various stages of deployment, for selected spin velocities ranging from 4 rpm upwards. A linear, time-invariant, feed-back control system is employed, with gains calculated via a root-specification procedure. The movable mass controller provides critical wobble-damping capability for the crew quarters for all configurations and spin velocity.

Childs, D. W.

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng

Modeling and Simulation for Exercise Vibration Isolation and Stabilization System Design

The microgravity environment that crew members experience on orbit presents a well-known health challenge, particularly when it comes to loss of muscle and bone mass. To counteract these negative effects, exercise countermeasures play a critical role in the daily routine of the crew on the International Space Station (ISS). To help inform requirements for upcoming exploration missions such as the Gateway Program, a new device, called the European Enhanced Exploration Exercise Device (E4D), is being built by the European Space Agency through their contractor, the Danish Aerospace Company. The E4D is being demonstrated on the ISS and is unique from other current exercise devices in that it provides four separate modalities in a single device: resistive, cycle ergometry, seated aerobic rowing, and rope pulling. To support the integration of E4D on ISS, a passive Vibration Isolation and Stabilization (VIS) system was required by NASA, and this responsibility was given to the Johnson Space Center. This paper describes the end-to-end process of modeling, simulation, and analysis used to inform the mechanical design of the VIS system. The process begins with the collection of representative exerciser motion capture (MoCap) through ground-based testing with the developmental E4D in both the Prototype Immersive Technology (PIT) Laboratory and the Active Response Gravity Offload System (ARGOS) facility at the Johnson Space Center. These collected MoCap data are processed through human biomechanics modeling to create forcing functions as input to a multibody dynamics simulation of the combined E4D/VIS system, with numerous resulting outputs. These outputs include microgravity accelerations, overall system displacements, internal and transmitted loads, as well as collisions. Microgravity accelerations are compared for compliance against ISS requirements while displacements are used for sway space determinations on the design and volumetric constraints within the targeted module. Internal loads are supplied to the supporting stress analysis teams and external loads for structural loads and dynamics teams, both at NASA and ESA. Finally, contact and clearance analysis is performed using the simulation to eliminate potential design issues. To ensure that the elements of the multibody simulation were verified and validated, correlation against multiple VIS related ground hardware testbeds was performed and characterized. In addition to the isolation part of the VIS problem, stabilization is also key to the integrated performance and evaluation. Due to the difficulty in defining ISS requirements in this area, the stability of the exerciser was inspected via analysis. Loss of balance was defined analytically as occurring when the resultant force vector acting on the exerciser lies outside the base of support of the feet. Both the VIS and E4D teams have recently gone through their Critical Design Reviews (CDRs) and the iterative model-based approach has been integral to inform mechanical design, particularly in the case of the VIS. This same end-to-end approach is now being applied for the Gateway Program, where an Exploration Exercise Device (EED) derived from the E4D and notional VIS for the device are under concept development.

Countermeasures

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION

Decision surface estimate of nonlinear system stability domain by Lie series method.

The Lie series recursive algorithm for Zubov's partial differential equation is used to generate two sets of points, where one represents the exact asymptotic stability boundary of an equilibrium state of the nonlinear system under consideration and the other is interior to it. Based on these two sets of data as training samples of two classes, a decision hypersurface can be determined such that it is a close approximation of the asymptotic stability boundary.

Kormanik, J.

Computer program determines system stability /DIGSTA/

Computer program implements a stability criterion that can be applied directly to the numerical solutions of systems of differential equations. The program accepts as input the time function of the system, a time to view the transient, and an acceptable amplitude boundary for any steady-state oscillation.

Lorenzo, C. F.