Search NASA⌕ Search

SEARCH · Search NASA

Results for “Salt convection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Single-phase, natural circulation annular flow measurements for cartridge loop irradiation experiments

The nuclear industry is increasingly considering cartridge-style experiments for irradiation testing of advanced reactor fuels and materials under flowing conditions. Cartridge loops do not require the extensive support infrastructure that are necessary for external flow loops and minimize the possibility of coolant solidification over the long distance from the reactor to the external facilities. However, there is a general lack of quality flow data for internally heated fluids in an annular configuration representative of a cartridge-type irradiation experiment, particularly one with natural circulation. To address this data need, a series of experiments was conducted to measure the natural circulation flow rates of pressurized water in a sealed, internally heated vessel with annular flow conditions that represent a molten salt or sodium cartridge loop. Temperatures and flow rates were measured under steady-state and transient conditions. Here, this paper describes the facility, methods, and results of the experiments, including the determination of nondimensional parameters. A simple 1D model of the natural convection flow rates agrees well with the experimental results. Applying this model to simulate a liquid salt cartridge experiment predicts that natural circulation flow might be able to provide liquid salt Reynolds numbers similar to those of some molten salt reactor concepts at relevant power densities.

42 ENGINEERING↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Study of Eutectic Molten Salts NaCl/KCl/ZnCl2 Heat Transfer Inside a Smooth Tube for High-Temperature Application

Abstract Eutectic salts NaCl-KCl-ZnCl2 and NaCl-KCl-MgCl2 are two of the chloride salt systems that are promising for being used as high-temperature heat transfer fluid (HTF) and thermal energy storage (TES) materials in a wide range of temperatures from 230 °C to 750 °C in concentrated solar thermal power systems. To conduct measurement of the heat transfer coefficient of the molten salt at high temperatures, a circulation system and instrumentation of flow and heat transfer was constructed. Experimental measurement of the convective heat transfer coefficients of NaCl-KCl-ZnCl2 (molar fraction: 13.8–41.9–44.3%) inside tubes has been accomplished to find the most suitable heat transfer correlations. Experience of salt processing and operation of the high-temperature heat transfer test system was obtained. Two correlations, Dittus-Boelter equation and Gnielinski’s correlation for Nusselt number against Reynolds number and Prandtl number, are evaluated using the test results, and the latter correlation is recommended due to its better agreement of prediction against tested data.

Energy & Fuels↗

An Improved Representation of Aerosol Wet Removal by Deep Convection and Impacts on Simulated Aerosol Vertical Profiles

Here, we introduce a physics-based aerosol wet removal scheme with unified treatments of aerosol transport and removal by convective clouds into the Community Atmosphere Model version 6. Since several important physical processes are still neglected or poorly represented in this new physics-based scheme, we develop secondary improvements to the parameterizations of aerosol activation, resuspension, and cloud-borne aerosol detrainment in this new scheme. Changes in the aerosol wet removal scheme cause tropospheric aerosol concentrations to decrease to different extents: compared to the control run, the physics-based scheme significantly decreases aerosol burdens by up to 60% over the southern Pacific Ocean, whereas the secondary improvements mitigate the decreasing tendency. The burden changes also depend on aerosol chemical components: the sulfate mass decrease is compensated by secondary production, black carbon (BC) is effectively removed via increasing the hygroscopicity of particulate organic matter from 0 to 0.2, and dust shows the most spatially heterogeneous changes. Simulated aerosol profiles are evaluated against aircraft-based observations over the Pacific and Atlantic Oceans. The secondary-improved scheme reduces the overestimations of upper tropospheric BC and sea salt concentrations by a factor of 10 and 1,000, respectively, and reproduces the dependence of BC mass decrease rates on cloud types. Consideration of convective cloud-borne aerosol detrainment plays the most important role in enhancing the aerosol wet removal and decreasing the positive biases of tropospheric BC and sea salt concentrations. We also summarize unresolved issues related to convective cloud genesis and microphysics, cloud-borne aerosol evolution, and BC and dust emissions.

54 ENVIRONMENTAL SCIENCES↗

Assessing Stainless Steel Compatibility in Flowing FLiBe Salt

To address the considerable interest in LiF-BeF 2 (FLiBe) compatibility for fission and fusion reactor applications, static and flowing compatibility experiments were conducted to assess the compatibility with type 316H stainless steel. In static testing at 550° and 650 °C, small mass changes were measured and posttest characterization of the FLiBe showed increased levels of Fe, Cr, Ni and Mn in the salt. Adding Be in the static salt test reduced the dissolution of Fe and Ni. Further, an initial assessment of mass transfer in flowing FLiBe without a Be addition was conducted using a monometallic 316H thermal convection loop (TCL) operated for 1000 h with a peak temperature of 650 °C. Similar to prior results in flowing FLiNaK salt, the 316H specimens exhibited small mass losses in the hot leg. Posttest characterization of the 316H specimens suggested Cr surface depletion in the hot and cold legs and possibly Fe deposition in the cold leg. To further understand this behavior, Cr and Fe dissolution was measured in static FLiBe at 550–650 °C.

316H stainless steel↗

Simulation of natural circulation cartridge loop experiments and application to molten salt reactors

This work uses the TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics (TH) code to model natural circulation cartridge loop experiments previously conducted at Oak Ridge National Laboratory (ORNL) using water and compares the simulated and experimental results. TRACE is also used to characterize natural circulation in the cartridge loop vehicle using FLiNaK as the working fluid. The experimental vehicle is a buoyancy-aided, annular cartridge loop, referred to as a thermosyphon, and is designed to aid in qualifying liquid–fueled and/or liquid–cooled irradiation experiments for the Versatile Test Reactor (VTR), which is currently being designed in the United States. Out-of-pile water experiments have been conducted using the cartridge and the Thermosyphon Test Loop facility at ORNL, and future experiments are anticipated that would use other molten salt surrogates as the working fluid, followed by eventual insertion of a similar cartridge into VTR. Additionally, this work aims to determine how well TRACE can replicate the natural convection conditions that were observed experimentally; this serves as an initial step for validating the modeling tool for design and safety calculations to support future irradiation experiments in VTR. Initial predictions of potential experiments were made using FLiNaK as the natural circulation fluid to demonstrate the relevance of the cartridge design to molten salt reactors (MSRs). Results from this study indicate that TRACE can accurately capture natural convection phenomena in the thermosyphon and that several design changes to the current cartridge vehicle are necessary to achieve hydraulic conditions similar to those expected in MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FLiBe Capsule Testing of 316H

This milestone was originally envisioned for completion in FY20 and was delayed due to the COVID-19 response and lack of FLiBe salt. In March 2021, FLiBe salt was received from Kairos Power. The nine capsule experiments with type 316H stainless steel specimens and 316 capsules were completed at 550° and 650°C for 1000 h to bracket the conditions expected in the subsequent thermal convection loop (TCL) experiment. In three capsules, Be metal was added for redox control. The specimen mass losses were low, similar to those observed previously for FLiNaK salt and the addition of Be reduced the average mass loss. Initial characterization suggested that some reaction with Be may have occurred. Therefore, Be was not included in the TCL experiment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MOSCATO Development and Integration in Fiscal Year 2022

During FY21, we conducted ongoing development work for the MOSCATO (Molten Salt Chemistry and Transport) solver. The code development work primarily consisted of transitioning capabilities from the original version of the solver, which was written in OpenFOAM, into Nek5000. In doing so, a fast, highly parallelizable solver was created that is capable of complex chemistry and corrosion simulations for engineering-scale molten salt systems. The Nek5000 version of MOSCATO is now fully featured and capable of higher-fidelity simulations than were previously possible. Demonstration cases including a thermal convection loop have been simulated to test these new capabilities. We built upon the work for FY22 and improved the code from several different perspectives. First, we improved the user interface by adding a new component to the official Nek5000 input file (.par). This new part contains documents parameters like, salt properties (density, viscosity, Cp, thermal conductivity), diffusion coefficients, standard potential, etc. Second, we built a conversion script to extract salt properties from the MSTDB-TP salt database and write to MOSCATO input file. Third, we migrated the code to NekRS, which is the GPU branch of Nek5000 and suitable for next generation supercomputers. Verification and Validation (V&V) work was also continued in FY22. Two tasks were performed. The first V&V task involved the validation of the Poisson-Nernst-Planck equation solver and Butler-Volmer electrode kinetics, by comparing with numerical and experimental data about thermoelectric cells. The second task involved the comparisons to corrosion results from a thermal convection loop run during the MSRE era. Satisfactory agreement was obtained from both tasks.

Yuan, Haomin↗

Highly selective ion separations based on counter-flow electromigration in nanoporous membranes

Highly selective ion separations are vital for recovering important salts, and membrane-based techniques may enable environmentally friendly ion separations that operate continuously. This study demonstrates that simply opposing convective flow with electromigration in track-etched membranes leads to remarkable selectivities among monovalent ions. Because the membrane-pore diameters are orders of magnitude larger than the ion diameters, advection moves all ions at the same velocity, whereas electrophoretic velocities are proportional to ion mobilities. Thus during counter-flow cation electromigration, less mobile cations have lower electromigration velocity components and pass through porous membranes more rapidly than more mobile cations. Using membranes with 400 nm pores, counter-flow electromigration gives Li + /K + selectivities of 100 and Li + /Na + selectivities around 30 in mixed-salt studies. In this work, numerical simulations based on the extended Nernst-Planck equation agree with trends in experimental data and highlight the importance of high Péclet numbers, high current-to-flow ratios, and uniform current distributions for achieving high selectivities. Importantly, experimental separations give high selectivities at 0.3 M ionic strength and low Li + /K + ratios, which suggest these methods may also work in brine solutions. Nevertheless, energy costs for such separations are high.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ekman-driven salt transport as a key mechanism for open-ocean polynya formation at Maud Rise

Open-ocean polynyas formed over the Maud Rise, in the Weddell Sea, during the winters of 2016–2017. Such polynyas are rare events in the Southern Ocean and are associated with deep convection, affecting regional carbon and heat budgets. Using an ocean state estimate, we found that during 2017, early sea ice melting occurred in response to enhanced vertical mixing of heat, which was accompanied by mixing of salt. The melting sea ice compensated for the vertically mixed salt, resulting in a net buoyancy gain. An additional salt input was then necessary to destabilize the upper ocean. This came from a hitherto unexplored polynya-formation mechanism: an Ekman transport of salt across a jet girdling the northern flank of the Maud Rise. Such transport was driven by intensified eastward surface stresses during 2015–2018. Our results illustrate how highly localized interactions between wind, ocean flow and topography can trigger polynya formation in the open Southern Ocean.

54 ENVIRONMENTAL SCIENCES↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗

High-Fidelity CFD Simulation of Mixed Convection and Forced Convection in a Pebble Bed Test Reactor Core

The Hermes low-power [35-MW(thermal)] reactor will be built and operated by Kairos Power LLC (KP) to demonstrate its fluoride salt-cooled high-temperature reactor (FHR) technology. In the KP FHR, the reactor core is composed of randomly packed pebbles with TRISO fuel particles inside with FLiBe flow upward through the core acting as a coolant. Previous numerical and experimental studies have been limited to either a small-size bed or to a lack of detailed measurements for heat transfer. Here, to address the lack of high-fidelity heat transfer data in a real-size FHR core, in this study, we simulated a pebble bed core with 34 374 pebbles randomly packed, similar to the Hermes reactor's size. The core radius was 14 times that of the pebble diameter, while the core height was 45 times. In this work, we were particularly interested in a mixed convection regime, where buoyancy is important. Therefore, we performed several large-eddy simulations at different Reynolds numbers (160 to 1000) with gravitational force included. The spectral element computational fluid dynamics code NekRS with graphics processing unit acceleration was used for this study. The low-Mach number approximation was applied to address property changes in the FLiBe and to account for buoyancy. A pure hexahedral mesh with 60 million elements was generated by the Voronoi cell method. At the polynomial order of 5, the total degrees of freedom was 7.5 billion. The developed case in this work is the first of its kind in terms of size and complexity. The local numerical data across the domain were obtained and compared with empirical correlations. After examining the data, we found the following conclusions. For pressure drop, the Reger correlation predicted less than a 5% error. On the other hand, for heat transfer, the Wakao correlation outperformed the others. Based on our findings, we recommend the use of the Wakao correlation for the Nusselt number calculation, and for pressure drop, the KTA (Kerntechnischer Ausschuss) correclation, among the available experimental correlations. In conclusion, the Reger direct numerical simulation-driven correlation for pressure drops should also be considered, given its best agreement with our calculations.

Mixed Convection↗

Measurement of the Natural Convection Heat Transfer in a Magnesium Oxide Electrolytic Cell Concept

The rate of heat transfer by natural convection between the wall and electrolyte of an electrolytic cell that produces magnesium (Mg) from magnesium oxide (MgO) at temperatures near 1000 °C in a molten fluoride salt electrolyte is presented. An experimental model of the cell was developed that enabled measurements of the heat transfer in the absence of electrolysis and at temperatures less than 100 °C over ranges of Rayleigh numbers from 1 × 10 -7 to 7 × 10 -8 and Prandtl numbers from 2 to 6200, ranges that include those anticipated in the operation of the MgO electrolytic cell. The model avoids the substantial experimental challenges associated with the high-temperature, corrosive molten salt to enable a conservative estimate of the heat transfer at a lower cost and greater accuracy than would otherwise be possible. The results are correlated by the expression Nu = 0.412Ra 0.23 Pr 0.15 with Nusselt numbers spanning 30–80. The application of the correlation shows that the heat transfer between the cell wall and the molten fluoride electrolyte at ≈1000 °C is characterized by convection coefficients between 100 and 600 W/m 2 -K and is fast enough to enable heat fluxes up to 10 W/cm 2 without compromising the structural integrity of the steel cell wall.

Engineering↗

Transient Modeling and Simulation of a Generic Stable Salt Reactor

A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.

stable salt reactor; transient simulations; system↗

Flow through negatively charged, nanoporous membranes separates Li + and K + due to induced electromigration

Flow through negatively charged nanopores separates Li + and K + with selectivities of up to 70 and Li + passages from 20% to above 100%. Remarkably, both the Li + /K + selectivity and Li + passage initially increase with flow rate, breaking the permeability/selectivity trade-off. Modelling demonstrates that flow through the membranes creates electric fields that retard transport of cations. Selectivity increases with flow rate because the K + electromigration velocity exceeds its convective velocity, but for Li + electromigration is weaker than convection. Here, modelling also shows the importance of controlling concentration polarization. With further work, related separations might provide highly pure Li salts for battery manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling and simulation of brinicle formation

Below the Arctic sea ice, under the right conditions, a flux of icy brine flows down into the sea. The icy brine has a much lower fusion point and is denser than normal seawater. As a result, it sinks while freezing everything around it, forming an ice channel called a brinicle (also known as ice stalactite). In this paper, we develop a mathematical model for this phenomenon, assuming cylindrical symmetry. The fluid is considered to be viscous and quasi-stationary. The heat and salt transport are weakly coupled to the fluid motion and are modelled with the corresponding conservation equations, accounting for diffusive and convective effects. Finite-element discretization is employed to solve the coupled system of partial differential equations. We find that the model can capture the general behaviour of the physical system and generate brinicle-like structures while also recovering dendrite composition, which is a physically expected feature aligned with previous experimental results. This represents, to our knowledge, the first complete model proposed that captures the global structure of the physical phenomenon even though it has some discrepancies, such as brine accumulation.

97 MATHEMATICS AND COMPUTING↗

MOSCATO Solver Development and Integration Plan

During FY21, we conducted ongoing development work for the MOSCATO (Molten Salt Chemistry and Transport) solver. The code development work primarily consisted of transitioning capabilities from the original version of the solver, which was written in OpenFOAM, into Nek5000. In doing so, a fast, highly parallelizable solver was created that is capable of complex chemistry and corrosion simulations for engineering-scale molten salt systems. The Nek5000 version of MOSCATO is now fully featured and capable of higher-fidelity simulations than were previously possible. Demonstration cases including a thermal convection loop have been simulated to test these new capabilities. Although capable of large-scale simulations, MOSCATO is not well-suited to parametric studies of complete reactor geometries. These types of simulations are instead better handled by reduced-order modeling codes such as ORNL’s Mole code. Reduced-order simulation tools like Mole, however, are dependent on high fidelity correlations to account for complex, coupled three-dimensional phenomena that they do not directly simulate. Tools such as MOSCATO must therefore be used to create these correlations, as suitable empirical relationships are not available for most molten salt systems. Toward that end, we used the Nek-derived version of MOSCATO to create new mass transfer correlations for three relevant cases including tubular, tube bank, and subchannel geometries. These new correlations are more accurate than any existing ones and can be readily integrated into any reduced-order modeling tools that are targeting full-scale MSR simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MSR Transient Simulation and MSRE Transient Benchmark with SAM and SPECTRA

In recent years, there has been renewed interest in molten salt reactors (MSRs) for their potential advantages compared to reactors that rely on solid fuel. In response to such interest, many methods and codes have been developed to capture the unique features of MSRs. Among them, SPECTRA and SAM are two system analysis codes that have been enhanced to include MSR-specific modeling capabilities, including delayed neutron precursor drift and modified point kinetics equations.This paper discusses the efforts taken to verify and validate these features. A standard MSR system test problem was developed to verify and demonstrate the capability of SPECTRA and SAM on the MSR transient simulation. Sixteen transients were simulated. Further, the results obtained from SPECTRA and SAM show good agreement. The Molten Salt Reactor Experiment transient experiments were reviewed and selected to validate the SPECTRA and SAM codes. The experiments included pump startup and coastdown tests at zero power, reactivity insertion tests at different power levels, frequency tests, and a natural convection test. The simulation results from SPECTRA and SAM show good agreement with the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗