Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Approaching Suspicious Substances Safely

A mineral identification tool that was developed for NASA's Mars Rover Technology Development program is now serving as a powerful tool for U.S. law enforcement agencies and military personnel to identify suspicious liquid and solid substances. The tool can measure unknown substances through glass and plastic packaging materials with the RamanProbe(TradeMark) focused fiber-optic probe. The probe length can be extended up to 200 meters to enable users to analyze potentially dangerous substances at a safe distance. In many cases, the spectrometer and personnel are kept in a safe zone while the probe is positioned next to the sample being analyzed. Being able to identify chemicals in remote locations also saves users time and labor, since otherwise the samples would need to be collected, transported, and prepared prior to measurement in the laboratory.

Source record↗

Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

Sarrazin, P.↗

Olivine Dissolution and Formation of Secondary phases in Ultramafic Soils

Introduction: Olivine has been proposed as an indicator for the duration of water-rock interaction within Martian rocks and sediments [1-3]. The use of olivine as a mineralogical indicator for past aqueous alteration on Mars requires interpretation of a complex combination of factors including pH, temperature, and composition [5,6]. Here, we examine the persistence of natural olivine within terrestrial ultramafic soils (Fe/Mg-rich, Al-poor) developing under different climatic conditions and the incipient dissolution of emplaced forsterite (Fo) and fayalite (Fa) surfaces to investigate environmental effects on incipient olivine dissolution, olivine persistence in soils, and formation of secondary phases. Methods: Field Sites. We examined olivine weathering and secondary material formation in ultramafic soils at 6 sites in the Klamath Mountains (KM) of northern California with a mean annual temperature of ~12.8℃ and precipitation of ~55.7-95.4 cm/year [7], and soil pH of ~6.5-7.3; 4 sites in the Tablelands (TB) of Newfoundland, Canada with a mean annual temperature of <3.9℃ and precipitation of ~120.0 cm/year [8], and soil pH of ~7.7; and at 3 sites at Pickhandle Gulch (PG), Nevada with a mean annual temperature of ~14.4℃ and precipitation of ~14.1 cm/year [7], and soil pH of ~8.5. Sampling sites span an age range of ~12.1-50+ kya in the Klamath Mountains [9,10] and ~13-30 kya in the Tablelands [11]. Pickhandle Gulch sites are undated. Parent Material and Soil Analyses. Polished thin sections of bulk soil prepared by Wagner Petrographic, Inc were carbon-coated and analyzed on a JEOL 2100 SEM in back-scattered electron mode in the EMIL lab at UNLV and at the 13-ID-E synchrotron beamline at Argonne National Laboratory using µXRF, µXRD, and XAS. Soil and parent material samples were powdered in a Fritsch pulverisette and analyzed by XRD and soil by VNIR. Soil preparation is further described in [12]. Disk Preparation, Burial, and Collection. Fo disks were cut from a column prepared via hot-pressing and Fa disks by sintering synthetic fayalite powder, see [13] for detail. Disks were polished to a 0.25-micron level with diamond grit. Disks were buried in 3 KM soils, 4 TB soils, and 3 PG soils, collected after exactly 365 days, and washed gently with 100% reagent grade ethanol to remove potential adhered soil material. Weathered disks and soil samples were stored in a -20℃ freezer until analysis. Unaltered control disks prepared identically to the buried disks were stored at -20℃ for the duration of the experiment. Disk Analyses. One Fo and Fa disk from each climate zone was analyzed on a variable pressure Zeiss Supra 40VP SEM at Northern Arizona University. A separate Fo and Fa disk from each climate zone was analyzed by XPS using a Physical Electronics VersaProbe II at the Penn State Univ. Materials Characterization Lab after a Na-dodecyl sulfate wash and ozonation to remove carbon contamination as in [14]. VNIR measurements were conducted at Johnson Space Center using an ASD FieldSpec3 under ambient lab conditions on a separate Fo and Fa disk from each climate zone. One separate Fo and Fa control sample was analyzed for each technique for comparison with weathered samples. XPS uncertainty was determined from 5 repeat measurements on controls. Results: Bedrock and Soil Results Olivine is present in the parent material in the KM and TB. Olivine is found in ~12.1 ka KM soils but is absent from all older soils, while persisting into the oldest (>20 ka) TB soil (Figure 1). In both locations, olivine is found as cores surrounded by a serpentine rind (Figure 2). VNIR spectra from the analyzed soils possess strong OH-associated spectral features at ~2.33 µm indicating the presence of Mg-rich phyllosilicates as well as ferric-oxide features at ~0.92 µm in the KM (Figure 3). Primary crystalline silicate grains mostly incorporate Fe2+, while poorly crystalline weathering rinds are best fit by ferric oxide XAS standards (Figure 4). µXRF also shows that Fe and Ni concentrate in weathering rinds and Cr remains within interior silicate grains (Figure 4). Buried Sample Results All Fo surfaces exhibited formation of dissolution features including shallow pitting not observed on controls. Dissolution features were most visually widespread on the KM disk (Figure 5). Leaching of Mg from KM and TB Fo disks was evident from <1.6 Mg/Si ratios measured by XPS (Figure 6). Fe-rich precipitates in SEM (Figure 5) and Fe presence in XPS scans (Figure 6) indicate Fe deposition onto KM and TB Fo disk surfaces. The appearance of a spectral feature at 0.55 µm in the VNIR spectra from the TB Fo suggests this Fe is ferric (Figure 7). The PG Fo appears least altered, with minimal formation of dissolution features in SEM (Figure 5), a Mg/Si ratio inconsistent with leaching (~2) (Figure 6), and VNIR spectra almost identical to the control sample. Analysis of Fa surfaces is ongoing. The higher temperatures and more acidic pH in the KM soils likely drive the faster dissolution of the Fo disks described above. While the TB soils experience greater precipitation than in the KM, the cooler temperatures and more basic soil pH facilitate observable but more limited alteration. The dry climate and basic soil pH at PG lead to minimal dissolution of the PG disk surfaces.

A D Feldman↗

Determination of Phenols and Trimethylamine in Industrial Effluents

For regulatory purposes to control certain odorous compounds the analysis of phenols and trimethylamines in industrial effluents is necessary. The Bay Area Air Pollution Control District laboratory has been determining these gases by gas chromatographic techniques. The procedures for sample collection, preparation for analysis and determination are described in detail. Typical data from various sources showing the effect of proposed regulations is shown. Extensive sampling and usage of these procedures has shown them to be accurate, reliable and suitable to all types of source effluents.

Levaggi, D. A.↗

Laboratory on the Moon: Equipping and Testing of a Habitat Laboratory for the Scientific Exploration of the Moon by Humans

A human habitat on the Moon is predestined to house a laboratory, especially if it is built for scientific missions on the Moon. This laboratory could be used for (1) conducting experiments utilizing the lunar gravity and prepare experiments to be placed outside the laboratory in the lunar environment, (2) conducting analyses of lunar rock and regolith in high volume, and (3) performing preliminary analyses and screening of samples to be sent to Earth for more detailed, specialized analysis. In the past, spaceflight missions have often been implemented by adding scientific instruments after most of the engineering work is already finished, limiting scientific studies to relatively scattered, insular topics. However, if prepared appropriately, a research laboratory on the Moon can help address scientific questions thoroughly and at a fundamental level. Moreover, the challenge of creating a viable habitat is not only an engineering one, but one that requires input from architects, designers, and psychologists. After all, the crew not only works inside the habitat laboratory, but they spend (close to) their entire time on the Moon inside the habitat and under the isolation and confinement that comes with it. We combine science, engineering, and architecture to create a habitat laboratory that meets their conflicting requirements: The laboratory of the Moon and Mars Base Analog (MaMBA) has been designed with inputs from (1) scientists of selected disciplines, particularly geology, materials science, chemistry, biology, and medicine, (2) space architects specializing on extraterrestrial bases, and (3) engineers for the constraints imposed by the lunar environment. The MaMBA laboratory was built in 2019 into the mock-up of the first MaMBA module (out of six). Subsequently, the laboratory was tested by volunteer scientists for its usability. The scientists used the laboratory for work deemed representative of lunar scientific analyses; the complete test runs lasted one week each, with one test run in June 2019 and the second test run in late September 2019 following some modifications suggested by the scientists. Here, we will present an overview of the scientific topics that we think should be addressed on the Moon, together with a suggestion of scientific instrumentation that would be helpful for such investigations. Moreover, we present the MaMBA laboratory, equipped with the proposed instrumentation, and the outcomes of the test runs with a particular focus on the lessons learned regarding the equipping of the laboratory.

Christiane Heinicke↗

LDEF space optics handbook

There is a need to present design guidelines derived from the Long Duration Exposure Facility (LDEF) space optics experiments to hardware designers. In response to this need a small study program was just started by SAIC and POD Associates for the Phillips Laboratory. The objective is to prepare a top-level review of available results on the behavior of certain optical components in the LDEF space experiments. The optics interest centers on optical surfaces and coatings, and fabrication processes for laser windows and mirrors. The program has two main parts: the first phase, to be completed by the end of 1992, consists of identifying and acquiring data from the appropriate investigators. The second phase, ending in December 1993, comprises report preparation as well as selected, prioritized, additional characterization of certain samples, coordinated with the principal investigators and the Phillips Laboratory. This program is getting under way at the time of the Symposium and does not warrant more than the present summary at this time.

Champetier, Robert J.↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover Final Submission

NASA's Mars 2020 Perseverance Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions to Mars. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality: seven new and/or upgraded scientific payloads, an upgraded arm and sampling system, and a Helicopter demonstration. These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagn

Gonzales, Edward C↗

Evaporation Rate Study and NDMA Formation from UDMH/NO2 Reaction Products

Laboratory samples of uns-dimethylhydrazine (UDMH) fuel/oxidizer (nitrogen dioxide) non-combustion reaction products (UFORP) were prepared using a unique permeation tube technology. Also, a synthetic UFORP was prepared from UDMH, N-nitrosodimethylamine (NDMA), dimethylammonium nitrate, sodium nitrite and purified water. The evaporation rate of UFORP and synthetic UFORP was determined under space vacuum (approx 10(exp -3) Torr) at -40 ?C and 0 ?C. The material remaining was analyzed and showed that the UFORP weight and NDMA concentration decreased over time; however, NDMA had not completely evaporated. Over 85% of the weight was removed by subjecting the UFORP to 10(-3) Torr for 7 hours at -40 ?C and 4 hours at 0 ?C. A mixture of dimethylammonium nitrate and sodium nitrite formed NDMA at a rapid rate in a moist air environment. A sample of UFORP residue was analyzed for formation of NDMA under various conditions. It was found that NDMA was not formed unless nitrite was added.

Buchanan, Vanessa D.↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Sample Handling and Processing on Mars for Future Astrobiology Missions

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

Beegle, Luther↗

Thermoluminescent dosimetry for LDEF experiment M0006

Experiment M0006 on the Long Duration Exposure Facility had as its objective the investigation of space radiation effects on various electronic and optical components, as well as on seed germination. The Grumman Corporate Research Center provided the radiation dosimetric measurements for M0006, comprising the preparation of thermoluminescent dosimeters (TLD) and the subsequent measurement and analysis of flight exposed and control samples. In addition, various laboratory exposures of TLD's with gamma rays and protons were performed to obtain a better understanding of the flight exposures.

Chang, J. Y.↗

Benchtop Detection of Proteins

A process, and a benchtop-scale apparatus for implementing the process, have been developed to detect proteins associated with specific microbes in water. The process and apparatus may also be useful for detection of proteins in other, more complex liquids. There may be numerous potential applications, including monitoring lakes and streams for contamination, testing of blood and other bodily fluids in medical laboratories, and testing for microbial contamination of liquids in restaurants and industrial food-processing facilities. A sample can be prepared and analyzed by use of this process and apparatus within minutes, whereas an equivalent analysis performed by use of other processes and equipment can often take hours to days. The process begins with the conjugation of near-infrared-fluorescent dyes to antibodies that are specific to a particular protein. Initially, the research has focused on using near-infrared dyes to detect antigens or associated proteins in solution, which has proven successful vs. microbial cells, and streamlining the technique in use for surface protein detection on microbes would theoretically render similar results. However, it is noted that additional work is needed to transition protein-based techniques to microbial cell detection. Consequently, multiple such dye/antibody pairs could be prepared to enable detection of multiple selected microbial species, using a different dye for each species. When excited by near-infrared light of a suitable wavelength, each dye fluoresces at a unique longer wavelength that differs from those of the other dyes, enabling discrimination among the various species. In initial tests, the dye/antibody pairs are mixed into a solution suspected of containing the selected proteins, causing the binding of the dye/antibody pairs to such suspect proteins that may be present. The solution is then run through a microcentrifuge that includes a membrane that acts as a filter in that it retains the dye/antibody/protein complexes while allowing any remaining unbound dye/antibody pairs to flow away. The retained dye/antibody/protein complexes are transferred to a cuvette, wherein they are irradiated with light from a miniature near-infrared laser delivered via a fiber-optic cable. The resulting fluorescence from the dye(s) is measured by use of a miniature spectrometer, the output of which is digitized, then analyzed by laptop computer. The software running in the computer identifies the protein species by the wavelengths of their spectral peaks and determines the amounts of the proteins, and thus, one day, microbes of the various species from the intensities of the peaks. The abovementioned removal of the unbound dye/antibody pairs during centrifugation prevents false positive readings. The process proves successful in detecting proteins in solution and thus can now be employed for use in microbe detection.

Scardelletti, Maximilian C.↗

Electrotransport purification of thorium under low pressure conditions

It was demonstrated that the ultrapurification of refractory metals by electrotransport refining could best be accomplished in the noncontaminating environment of an orbiting low density materials laboratory such as the Molecular Shield Device. Refining experiments were performed at 2 x 10 to the -12th Torr which resulted in the preparation of small quantities of the World's purest thorium metal. The microgravity occurring in orbit was simulated electromagnetically and shown to be advantageous in eliminating grain-sliding caused by the plastic deformation of the sample at high temperature. The electrotransport sample assembly was tested in several environments including simulated solar irradiation, coldness and darkness and under various pressure conditions. Ultrapure single crystals of alpha thorium were also prepared and characterized. Laboratory electronics for the experiment were developed and a totally automatic control system was used to heat the specimens.

Schmidt, F. A.↗

A Review of the Handheld X-Ray Fluorescence Spectrometer as a Tool for Field Geologic Investigations on Earth and in Planetary Surface Exploration

X-ray fluorescence (XRF) spectroscopy is a well-established and commonly used technique in obtaining diagnostic compositional data on geological samples. Recently, developments in X-ray tube and detector technologies have resulted in miniaturized, field-portable instruments that enable new applications both in and out of standard laboratory settings. These applications, however, have not been extensively applied to geologic field campaigns. This study investigates the feasibility of using developing handheld XRF (hXRF) technology to enhance terrestrial field geology, with potential applications in planetary surface exploration missions. We demonstrate that the hXRF is quite stable, providing reliable and accurate data continuously over a several year period. Additionally, sample preparation is proved to have a marked effect on the strategy for collecting and assimilating hXRF data. While the hXRF is capable of obtaining data that are comparable to laboratory XRF analysis for several geologically-important elements (such as Si, Ca, Ti, and K), the instrument is unable to detect other elements (such as Mg and Na) reliably. While this limits the use of the hXRF, especially when compared to laboratory XRF techniques, the hXRF is still capable of providing the field user with significantly improved contextual awareness of a field site, and more work is needed to fully evaluate the potential of this instrument in more complex geologic environments.

Young, Kelsey E.↗

Application of Ion Mobility Spectrometry (IMS) in forensic chemistry and toxicology with focus on biological matrices

The IMS (Ion Mobility Spectroscopy) instrument 'Ionscan' takes advantage of the fact that trace quantities of illicit drugs are adsorbed on dust particles on clothes, in cars and on other items of evidence. The dust particles are collected on a membrane filter by a special attachment on a vacuum cleaner. The sample is then directly inserted into the spectrometer and can be analyzed immediately. We show casework applications of a forensic chemistry and toxicology laboratory. One new application of IMS in forensic chemistry is the detection of psilocybin in dried mushrooms without any further sample preparation.

Bernhard, Werner↗