Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Overview of advanced plasma-facing materials testing for Fusion Pilot Plants at DIII-D

Characterization and testing of advanced plasma-facing materials (PFMs) for Fusion Pilot Plants (FPP) is being conducted at the DIII-D National Fusion Facility through the ongoing two-year FPP Candidate Materials Thrust. Year one tested 17 novel materials utilizing the Divertor Materials Evaluation System (DiMES), with samples analyzed pre- and post-experiment via SEM, EDS, and confocal microscopy. Repeatable reference discharges were developed to ensure uniformity between experiments, including a new strike-point rastering scenario to provide more uniform heat/particle flux across DiMES during ELMing H-mode discharges. Various sample geometries and temperatures were used to achieve FPP-relevant conditions, including samples angled 10° towards the incident plasma flux and pre-heating up to 500 °C. The first exposure of liquid lithium (Li) capillary porous structures in a tokamak demonstrated uniform emission of Li vapor and suppression of Li droplets in H-mode when preheated to 350 °C. Dispersoid-strengthened W with 1 wt% TaC, TiC, and ZrC exposed to H-mode showed cracking and dispersoid ejection for all varieties except TiC, providing a clear down-selection. Ultra-high temperature ceramic materials TiB 2 and ZrB 2 showed minimal degradation under L-mode exposure. Silicon carbide (SiC) fiber composites showed arcing along edges, while CVD SiC remained pristine. Atmospheric plasma-sprayed W and SiC coatings endured H-mode exposure without macroscopic delamination; SiC exhibited granular ejection, while W showed increased outgassing. Additional W-based alloys were stress tested in H-mode, including Ni-based W heavy alloys, W f SiC f /W composites, W multi-principle element alloys, and functionally-graded W/SiC, to varying degrees of success.

DIII-D↗

Electric Field Effects on the Hidden Order of Microstructured URu 2 Si 2

Despite being studied for over 30 years there is still continual interest in they heavy-fermion URu 2 Si 2 due largely in part to the still disagreed upon origin of the so-called hidden-order (HO) state that arises below THO = 17.5 K. While both the application of pressure and high magnetic fields have been shown to suppress the HO state, one mechanism that has yet to be explored is the application of an electric field, most likely due to the difficulty of measuring such an effect in a metal. To overcome this challenge we have used focused ion beam (FIB) lithography to obtain the necessary sample geometry to create an electric field across a small section of the sample by applying a voltage. Our results suggest that at low temperatures the application of an electric field is able to suppress the hidden order state.

36 MATERIALS SCIENCE↗

Development of combined microstructure and structure characterization facility for in situ and operando studies at the Advanced Photon Source

Following many years of evolutionary development, first at the National Synchrotron Light Source, Brookhaven National Laboratory, and then at the Advanced Photon Source (APS), Argonne National Laboratory, the APS ultra-small-angle X-ray scattering (USAXS) facility has been transformed by several new developments. These comprise a conversion to higher-order crystal optics and higher X-ray energies as the standard operating mode, rapid fly scan measurements also as a standard operational mode, automated contiguous pinhole small-angle X-ray scattering (SAXS) measurements at intermediate scattering vectors, and associated rapid wide-angle X-ray scattering (WAXS) measurements for X-ray diffraction without disturbing the sample geometry. With each mode using the USAXS incident beam optics upstream of the sample, USAXS/SAXS/WAXS measurements can now be made within 5 min, allowing in situ and operando measurement capabilities with great flexibility under a wide range of sample conditions. Furthermore, these developments are described, together with examples of their application to investigate materials phenomena of technological importance. Developments of two novel USAXS applications, USAXS-based X-ray photon correlation spectroscopy and USAXS imaging, are also briefly reviewed.

47 OTHER INSTRUMENTATION↗

Rapid method for computing the mechanical resonances of irregular objects

A solid object's geometry, density, and elastic moduli completely determine its spectrum of normal modes. Solving the inverse problem—determining a material's elastic moduli given a set of resonance frequencies and sample geometry—relies on the ability to compute resonance spectra accurately and efficiently. Established methods for calculating these spectra are either fast but limited to simple geometries, or are applicable to arbitrarily shaped samples at the cost of being prohibitively slow. Here, we describe a method to rapidly compute the normal modes of irregularly shaped objects using entirely open-source software. Our method's accuracy compares favorably with existing methods for simple geometries and shows a significant improvement in speed over existing methods for irregular geometries.

Acoustics↗

An Analysis Technique for Active Neutron Multiplicity Measurements Based on First Principles

Passive neutron multiplicity counting is commonly used to quantify the total mass of plutonium in a sample, without prior knowledge of the sample geometry. However, passive neutron counting is less applicable to uranium measurements due to the low spontaneous fission rates of uranium. Active neutron multiplicity measurements are therefore used to determine the {sup 235}U mass in a sample. Unfortunately, there are still additional challenges to overcome for uranium measurements, such as the coupling of the active source and the uranium sample. Techniques, such as the coupling method, have been developed to help reduce the dependence of calibration curves for active measurements on uranium samples; although, they still require similar geometry known standards. An advanced active neutron multiplicity measurement method is being developed by Texas A&M University, in collaboration with Los Alamos National Laboratory (LANL) in an attempt to overcome the calibration curve requirements. This method can be used to quantify the {sup 235}U mass in a sample containing uranium without using calibration curves. Furthermore, this method is based on existing detectors and nondestructive assay (NDA) systems, such as the LANL Epithermal Neutron Multiplicity Counter (ENMC). This method uses an inexpensive boron carbide liner to shield the uranium sample from thermal and epithermal neutrons while allowing fast neutrons to reach the sample. Due to the relatively low and constant fission and absorption energy dependent cross-sections at high neutron energies for uranium isotopes, fast neutrons can penetrate the sample without significant attenuation. Fast neutron interrogation therefore creates a homogeneous fission rate in the sample, allowing for first principle methods to be used to determine the {sup 235}U mass in the sample. This paper discusses the measurement method concept and development, including measurements and simulations performed to date, as well as the potential limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sub-sized specimen testing and its relationship with Gen IV Materials Qualification

Renewed interest in advanced reactor technologies which can produce inherently safe, reliable, low carbon, low cost energy requires the development of new materials which can operate in the extreme environments proposed by Gen IV reactor designs. The primary focus of the Nuclear Materials Discovery and Qualification Initiative (NMDQi) is to accelerate the process by which new materials can make their way into commercial use, enabling new technologies and innovations within the nuclear sector. Due to limitations in the production of neutron irradiated material for testing and qualification, the use of specimens far smaller than those traditionally called for in regulatory codes becomes a necessity. While the use of these sub-sized specimens is necessary to achieve materials qualification on a realistic timeline and budget, literature showing the efficacy of these samples as an appropriate surrogate for ASME/ASTM defined samples is limited. This poster will detail historical efforts to compare the mechanical behavior of small geometry samples with bulk material behavior and the potential of sub-sized specimen testing at INL for future materials qualification efforts.

36 MATERIALS SCIENCE↗

Ultra-high temperature testing and performance of L-PBF C103

Additive Manufacturing (AM) of refractory alloys is gaining traction as a materials processing route for components subject to extreme temperature environments. Due to the low oxidation resistance of refractory alloys, novel methods for evaluating their elevated temperature performance must be developed. In this work, a Gleeble® 3800 thermomechanical load frame was modified to evaluate the mechanical properties of laser powder bed fusion (L-PBF) consolidated niobium alloy C103 ranging from room temperature (RT) to 1400 °C. The fixturing and sample geometry were designed to accommodate Joule heating and prevent damage to the test chamber. Oxidation of the samples was minimized via testing in vacuum level of 1E-5 Torr. Ultimate tensile strength (UTS), yield strength (YS), elongation, and strain-hardening behavior were determined as a function of temperature. L-PBF C103 presented an average UTS of ∼650 MPa and over 25 % elongation at RT. Above RT, the UTS and YS dropped then leveled off from 500 °C to 1000 °C with values ranging from ∼400 MPa to ∼460 MPa, which is consistent with dynamic strain aging observed in this class of alloys. The strength rapidly declined after 1200 °C to ∼150 MPa at 1400 °C. Fractography indicated ductile fractures for the C103 at all test temperatures, and Electron Backscatter Diffraction (EBSD) analysis revealed a textured microstructure and the presence of dynamic recrystallization within the necked region of the sample tested at 1400 °C.

33 ADVANCED PROPULSION SYSTEMS↗

Stability of multipole-mode solitons in thermal nonlinear media

We study the stability of multipole-mode solitons in one-dimensional thermal nonlinear media. We show how the sample geometry impacts the stability of multipole-mode solitons and reveals that the tripole and quadrupole can be made stable in their whole domain of existence, provided that the sample width exceeds a critical value. In spite of such geometry-dependent soliton stability, we find that the maximal number of peaks in stable multipole-mode solitons in thermal media is the same as that in nonlinear materials with finite-range nonlocality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of lateral carrier confinement on electro-optical tuning properties of polariton condensates

Electro-optical measurements on exciton-polaritons below and above the condensation threshold are performed on high quality, pin-doped microcavities with embedded GaAs quantum wells. Applying an external electric field shifts the polariton emission by hundreds of μeV both in the linear and the nonlinear regime. We study three device geometries to investigate the influence of carrier confinement in the plane of the quantum well on the electro-optical tuning properties. In the conventional micropillar geometry, the electric field tuning behavior is dominated by the effects of carrier tunneling and electric field screening that manifest in a blueshift of the polariton emission. In stark contrast, for a planar sample geometry, we can significantly extend the range of electric fields and a redshift is observed. To separate the contributions of quantum confined Stark effect and reduced exciton oscillator strength to the energy shift, we study a third sample where the etching of micropillars is stopped just above the active region. In this semi-planar geometry, exciton and polariton emissions can be measured simultaneously. As for the planar geometry, redshifts of the polariton emission are observed below and above threshold that are well reproduced by theoretical shifts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the bidirectional reflectance distribution function of mixed finite plant canopies and soil

An analytical model of the bidirectional reflectance for optically semi-infinite plant canopies has been extended to describe the reflectance of finite depth canopies contributions from the underlying soil. The model depends on 10 independent parameters describing vegetation and soil optical and structural properties. The model is inverted with a nonlinear minimization routine using directional reflectance data for lawn (leaf area index (LAI) is equal to 9.9), soybeans (LAI, 2.9) and simulated reflectance data (LAI, 1.0) from a numerical bidirectional reflectance distribution function (BRDF) model (Myneni et al., 1988). While the ten-parameter model results in relatively low rms differences for the BRDF, most of the retrieved parameters exhibit poor stability. The most stable parameter was the single-scattering albedo of the vegetation. Canopy albedo could be derived with an accuracy of less than 5% relative error in the visible and less than 1% in the near-infrared. Sensitivity were performed to determine which of the 10 parameters were most important and to assess the effects of Gaussian noise on the parameter retrievals. Out of the 10 parameters, three were identified which described most of the BRDF variability. At low LAI values the most influential parameters were the single-scattering albedos (both soil and vegetation) and LAI, while at higher LAI values (greater than 2.5) these shifted to the two scattering phase function parameters for vegetation and the single-scattering albedo of the vegetation. The three-parameter model, formed by fixing the seven least significant parameters, gave higher rms values but was less sensitive to noise in the BRDF than the full ten-parameter model. A full hemispherical reflectance data set for lawn was then interpolated to yield BRDF values corresponding to advanced very high resolution radiometer (AVHRR) scan geometries collected over a period of nine days. The resulting parameters and BRDFs are similar to those for the full sampling geometry, suggesting that the limited geometry of AVHRR measurements might be used to reliably retrieve BRDF and canopy albedo with this model.

Schluessel, G.↗

Self-Organized Criticality and Phase Problem in Magnetoaocustic Emission Burst in Ferromagnets

Two types of ferromagnets, pure iron and steel with varying geometry and microstructural properties, were prepared for the present study of magnetoacoustic emission (MAE). The purpose was to separate the effects of structural property variations from changes caused by differences in the sample geometry. The position and shape of the leading MAE sub-burst and its variation among the samples are explained by magnetic anisotropy and the results of numerical simulations which utilized the concept of self-organized criticality (SOC). The amplitude and duration of the second sub-burst, which previously was thought to occur as a result of a complicated interaction between non-180 deg domain walls and lattice defects, can easily be explained by the results of our simulation.

Namkung, M.↗

Enabling direct nanoscale observations of biological reactions with dynamic TEM

Biological processes can occur over a wide range of spatial and temporal scales; from femtoseconds to hours and from angstroms to meters. Although no single experimental method can fully cover this entire phase space, many new biological insights can be expected from a better understanding of the processes that occur on the very fast timescales and very small length scales. In this regard, new instruments that use fast x-ray or electron pulses are now available that are expected to reveal new mechanistic insights for macromolecular protein dynamics. To ensure that any observed conformational change is physiologically relevant and not constrained by three-dimensional crystal packing, it would be preferable for experiments to utilize smaller protein samples such as single particles or two-dimensional crystals that mimic the target protein’s native environment. These samples aren’t typically amenable to x-ray analysis, but transmission electron microscopy has successfully imaged such sample geometries for over 40 years and permits data acquisition using both direct imaging and diffraction modes. While conventional transmission electron microscopes (TEM) have only visualized biological samples with atomic resolution in an arrested or frozen state, the recent development of the dynamic TEM (DTEM) extends electron microscopy capabilities into dynamics. A new 2nd generation DTEM that is currently being constructed has the potential to observe live biological processes with unprecedented spatiotemporal resolution by using pulsed electron packets to probe the sample on the micro- and nanosecond timescale. In addition to the enhanced temporal resolution, the DTEM also operates in the pump-probe regime that can permit visualizing reactions propagating in real-time. This article reviews the experimental parameters necessary for coupling DTEM with in situ liquid microscopy to allow direct imaging of protein conformational dynamics in a fully hydrated environment.

Dynamic TEM↗

Modeling and simulation framework for dynamic strain localization in elasto-viscoplastic metallic materials subject to large deformations

This study describes a theoretical and computational framework for the treatment of adiabatic shear band formation in rate-sensitive polycrystalline metallic materials. From a computational perspective, accurate representation of strain localization behavior has been a long-standing challenge. In addition, the underlying physical mechanisms leading to the localization of plastic deformation are still not fully understood. The proposed framework is built around an enhanced-strain finite element formulation, designed to alleviate numerical pathologies known to arise in localization problems, by allowing a localization band of given finite width (weak discontinuity) to be embedded within individual elements. The mechanical threshold strength (MTS) model is used to represent the temperature and strain rate-dependent viscoplastic response of the material. This classical flow stress model employs an internal state variable to quantify the effect of dislocation structure evolution (work hardening and recovery). In light of growing evidence suggesting that the softening effect of dynamic recrystallization may play a significant role, alongside thermal softening, in the process of shear band formation and growth, a simple dynamic recrystallization model is proposed and cast within the context of the MTS model with the aid of the aforementioned internal state variable. An initiation criterion for shear localization in rate and temperature-sensitive materials is introduced and used in the present context of high-rate loading, where material rate-dependence is pronounced and substantial temperature increases are achieved due to the dissipative nature of viscoplastic processes. In addition, explicit time integration is adopted to facilitate treatment of the dynamic problems under consideration, where strain rates in excess of 10 4 s –1 are typically attained. Two series of experiments are conducted on AISI 316L stainless steel, employing the commonly used top-hat sample geometry and the Split-Hopkinson Pressure Bar dynamic test system. Axi-symmetric finite element simulation results are compared to cross-sectional micrographs of recovered samples and experimental load–displacement results, in order to examine the performance of the proposed framework and demonstrate its effectiveness in treating the initiation and growth of adiabatic shear banding in dynamically loaded metallic materials. These comparisons demonstrate that thermal softening alone is insufficient to induce shear localization behaviors observed in some materials, such as stainless steel, and support the hypothesis that dynamic recrystallization and/or other softening mechanisms play an essential role in this process.

36 MATERIALS SCIENCE↗

Temperature distributions in the laser-heated diamond anvil cell from 3-D numerical modeling

We present TempDAC, a 3-D numerical model for calculating the steady-state temperature distribution for continuous wave laser-heated experiments in the diamond anvil cell. TempDAC solves the steady heat conduction equation in three dimensions over the sample chamber, gasket, and diamond anvils and includes material-, temperature-, and direction-dependent thermal conductivity, while allowing for flexible sample geometries, laser beam intensity profile, and laser absorption properties. The model has been validated against an axisymmetric analytic solution for the temperature distribution within a laser-heated sample. Example calculations illustrate the importance of considering heat flow in three dimensions for the laser-heated diamond anvil cell. In particular, we show that a “flat top” input laser beam profile does not lead to a more uniform temperature distribution or flatter temperature gradients than a wide Gaussian laser beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airfoil sampling of a pulsed Laval beam with tunable vacuum ultraviolet (VUV) synchrotron ionization quadrupole mass spectrometry: Application to low--temperature kinetics and product detection

A new pulsed Laval nozzle apparatus with vacuum ultraviolet (VUV) synchrotron photoionization quadrupole mass spectrometry is constructed to study low-temperature radicalneutralchemical reactions of importance for modeling the atmosphere of Titan and the outer planets. A design for the sampling geometry of a pulsed Laval nozzle expansion has beendeveloped that operates successfully for the determination of rate coefficients by time-resolved mass spectrometry. The new concept employs airfoil sampling of the collimated expansion withexcellent sampling throughput. Time-resolved profiles of the high Mach number gas flow obtained by photoionization signals show that perturbation of the collimated expansion by theairfoil is negligible. The reaction of C2H with C2H2 is studied at 70 K as a proof-of-principle result for both low-temperature rate coefficient measurements and product identification basedon the photoionization spectrum of the reaction product versus VUV photon energy. This approach can be used to provide new insights into reaction mechanisms occurring at kinetic ratesclose to the collision-determined limit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoluminescence response of a quantum well to a change in the magnetic field of the Mn {delta} Layer in InGaAs/GaAs heterostructures

Ferromagnetic ordering of two types (depending on the sample geometry) is found to occur in a thin Ga{sub 1-x}Mn{sub x}As alloy layer (Mn {delta} layer) in heterostructures containing an InGaAs/GaAs quantum well. Singular samples in which the {delta} Mn layer is parallel to the (001) GaAs plane exhibit the '3/2' Bloch temperature dependence of magnetization, and vicinal samples in which the {delta} Mn layer deviates from the (001) GaAs plane exhibit a 'percolation' ferromagnetic transition. The photoluminescence polarization of the quantum well is shown to follow changes in the magnetization of the Mn {delta} layer as a function of temperature according to the Bloch law in the singular samples and to a percolation law in the vicinal samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interpretation of dark-field contrast and particle-size selectivity in grating interferometers

In grating-based x-ray phase sensitive imaging, dark-field contrast refers to the extinction of the interference fringes due to small-angle scattering. For configurations where the sample is placed before the beamsplitter grating, the dark-field contrast has been quantified with theoretical wave propagation models. Yet when the grating is placed before the sample, the dark-field contrast has only been modeled in the geometric optics regime. Here we attempt to quantify the dark-field effect in the grating-before-sample geometry with first-principle wave calculations and understand the associated particle-size selectivity. We obtain an expression for the dark-field effect in terms of the sample material's complex refractive index, which can be verified experimentally without fitting parameters. A dark-field computed tomography experiment shows that the particle-size selectivity can be used to differentiate materials of identical x-ray absorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗