Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rapid, Sensitive, Label-Free Electrical Detection of SARS-CoV-2 in Nasal Swab Samples

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.

60 APPLIED LIFE SCIENCES↗

Novel Ultrafast Lu2O3:Yb Ceramics for Future HEP Applications

Inorganic scintillators activated by charge transfer luminescence Yb3+ are considered promising ultrafast material to break the ps timing barrier for future high energy physics applications. Inorganic scintillators in ceramic form are potentially more cost-effective than crystals because of their lower fabrication temperature and no need for aftergrowth mechanical processing. This paper reports an investigation on Lu2O3:Yb and Lu2xY2(1−x)O3:Yb scintillating ceramic samples fabricated by Radiation Monitoring Devices Inc. All samples show X-ray excited luminescence peaked at 370 nm. Ultrafast decay time of 1.1 ns was observed by using a microchannel plate-photomultiplier tube-based test bench at Caltech. Considering its intrinsic high density (9.4 g/cm3), Lu2O3:Yb ceramics are promising for future time of fight application for high energy physics experiments.

47 OTHER INSTRUMENTATION↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Imaging dynamic exciton interactions and coupling in transition metal dichalcogenides

Transition metal dichalcogenides (TMDs) are regarded as a possible material platform for quantum information science and related device applications. In TMD monolayers, the dephasing time and inhomogeneity are crucial parameters for any quantum information application. In TMD heterostructures, coupling strength and interlayer exciton lifetimes are also parameters of interest. However, many demonstrations in TMDs can only be realized at specific spots on the sample, presenting a challenge to the scalability of these applications. Here, using multi-dimensional coherent imaging spectroscopy, we shed light on the underlying physics—including dephasing, inhomogeneity, and strain—for a MoSe 2 monolayer and identify both promising and unfavorable areas for quantum information applications. We, furthermore, apply the same technique to a MoSe 2 /WSe 2 heterostructure. Despite the notable presence of strain and dielectric environment changes, coherent and incoherent coupling and interlayer exciton lifetimes are mostly robust across the sample. This uniformity is despite a significantly inhomogeneous interlayer exciton photoluminescence distribution that suggests a bad sample for device applications. This robustness strengthens the case for TMDs as a next-generation material platform in quantum information science and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Serial femtosecond and serial synchrotron crystallography can yield data of equivalent quality: A systematic comparison

For the two proteins myoglobin and fluoroacetate dehalogenase, we present a systematic comparison of crystallographic diffraction data collected by serial femtosecond (SFX) and serial synchrotron crystallography (SSX). To maximize comparability, we used the same batch of micron-sized crystals, the same sample delivery device, and the same data analysis software. Overall figures of merit indicate that the data of both radiation sources are of equivalent quality. For both proteins, reasonable data statistics can be obtained with approximately 5000 room-temperature diffraction images irrespective of the radiation source. The direct comparability of SSX and SFX data indicates that the quality of diffraction data obtained from these samples is linked to the properties of the crystals rather than to the radiation source. Therefore, for other systems with similar properties, time-resolved experiments can be conducted at the radiation source that best matches the desired time resolution.

59 BASIC BIOLOGICAL SCIENCES↗

Physical layer authentication of electronic communication networks

A network authentication system can be configured for sampling a plurality of signal samples from a device on a network, providing the plurality of signal samples to a first machine-learned model that is configured to determine a device fingerprint based at least in part on the plurality of signal samples, and providing the device fingerprint to a second machine-learned model that is configured to classify the device based at least in part on the device fingerprint.

97 MATHEMATICS AND COMPUTING↗

Demonstration of an Automated System for Vertical Profiles of Volatile Organic Compounds

Volatile organic compounds (VOCs) play important roles throughout the atmosphere, many of which are altitude dependent. This highlights the need for easily deployable devices to sample VOCs across different atmospheric layers. To address this, we present the design and initial application of a Time Resolved Automated Volatile organIc compounds Sampling system (TRAVIS). VOCs are collected on sorbent tubes, which are subsequently analyzed by a thermal desorption gas chromatography mass spectrometry pipeline. TRAVIS leverages a piezoelectric pump with an integrated pressure sensor for precise (0.1% flow rate relative standard deviation) and accurate (−3 ± 2% error in VOC quantitation) measurements. Via deployment on a tethered balloon system over an agricultural area, TRAVIS is used to show consistent vertically resolved VOC concentrations in a well-mixed (i.e., turbulent) atmosphere (e.g., 5% relative standard deviation for isoprene) and vertically dependent concentrations for a stratified atmosphere (e.g., prior to boundary layer development). Furthermore, we also show VOC information from an intermittent plume via both targeted and untargeted analysis, highlighting future applications for spurious events in agriculture, air quality monitoring, and environmental impact. Overall, the development of TRAVIS represents a lightweight, accurate, sensitive, and precise VOC sampling module for the scientific community.

Aerosols↗

Signatures of moiré trions in WSe 2 /MoSe 2 heterobilayers

Moiré superlattices formed by van der Waals materials can support a wide range of electronic phases, including Mott insulators superconductors and generalized Wigner crystals2. When excitons are confined by a moiré superlattice, a new class of exciton emerges, which holds promise for realizing artificial excitonic crystals and quantum optical effects. When such moiré excitons are coupled to charge carriers, correlated states may arise. However, no experimental evidence exists for charge-coupled moiré exciton states, nor have their properties been predicted by theory. In this work, we report the optical signatures of trions coupled to the moiré potential in tungsten diselenide/molybdenum diselenide heterobilayers. The moiré trions show multiple sharp emission lines with a complex charge-density dependence, in stark contrast to the behaviour of conventional trions. We infer distinct contributions to the trion emission from radiative decay in which the remaining carrier resides in different moiré minibands. Variation of the trion features is observed in different devices and sample areas, indicating high sensitivity to sample inhomogeneity and variability. The observation of these trion features motivates further theoretical and experimental studies of higher-order electron correlation effects in moiré superlattices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

All polymer microfluidic chips—A fixed target sample delivery workhorse for serial crystallography

The development of x-ray free electron laser (XFEL) light sources and serial crystallography methodologies has led to a revolution in protein crystallography, enabling the determination of previously unobtainable protein structures and near-atomic resolution of otherwise poorly diffracting protein crystals. However, to utilize XFEL sources efficiently demands the continuous, rapid delivery of a large number of difficult-to-handle microcrystals to the x-ray beam. A recently developed fixed-target system, in which crystals of interest are enclosed within a sample holder, which is rastered through the x-ray beam, is discussed in detail in this Perspective. The fixed target is easy to use, maintains sample hydration, and can be readily modified to allow a broad range of sample types and different beamline requirements. Recent innovations demonstrate the potential of such microfluidic-based fixed targets to be an all-around “workhorse” for serial crystallography measurements. In conclusion, this Perspective will summarize recent advancements in microfluidic fixed targets for serial crystallography, examine needs for future development, and guide users in designing, choosing, and utilizing a fixed-target sample delivery device for their system.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmarking Microscale Ductility Measurements (Final Report of the Project DE-NE0008799)

Conventional macroscale experimentation is generally considered to be straightforward with few limitations. Conversely, micro/nanoscale experimentation presents numerous challenges in loading device design, sample preparation and handling, as well as accurate understanding of grain size and local texture effects on recorded measurements. Despite these challenges, nanopillar compression, MEMs based micro-tension, and nanoindentation approaches have been able to provide fundamental contributions to the understanding of material behavior at small lengthscales. However, the overarching shortcoming of these micro/nanoscale experimentation approaches, is the inability to directly translate measurements evaluated at the nm and µm length scales (e.g., hardness) to macroscale tensile material behavior (i.e., elastic modulus, yield strength, and ductility). The objectives of the proposed study are, 1) to establish best practices for obtaining tensile microscale ductility measurements, and 2) to validate methodologies to for comparing microscale ductility measurements to macroscale ductility measurements. In order to achieve these objectives, a multi-lengthscale, multi-temperature testing protocol and simulation framework are executed first on copper as a model material to validate the following approach, and second on reactor grade Zircaloy-2. Experiments are conducted on specimens extracted from the same test piece to ensure nominally identical grain size and texture from specimens to specimen. Motivated by the need to isolate the contribution of size-effects on obtained mechanical property measurements, specimens are manufactured with thicknesses at the micro- (1-10 µm), meso- (10-100's µm), and macroscales (sub-sized ASTM E8). In-situ full-field deformation techniques (scanning electron microscopy (SEM) grid methods and optical DIC) are incorporated into testing at each specimen length-scale to capture plasticity localization and evolution. Experimental testing for all specimens is conducted at both room temperature and elevated temperatures to probe the role of thermal activation on plastic deformation accommodation processes. Simulation efforts focus on examining the mechanical behavior of microscale specimens using a finite element approach with explicitly resolved grain morphologies, and an embedded crystal plasticity model. The cost-efficient implementation method allows for the modeling of a statistically significant number of both real (i.e., digital twin) and generated microstructures to obtain an understanding of the interrelationships between specimen microstructure and geometric variables (grain size, texture, specimen geometry, etc.) on microscale mechanical behavior.

36 MATERIALS SCIENCE↗

A Beginner's Guide to Power and Energy Measurement and Estimation for Computing and Machine Learning

Concerns about the environmental footprint of machine learning are increasing. While studies of energy use and emissions of ML models are a growing subfield, most ML researchers and developers still do not incorporate energy measurement as part of their work practices. While measuring energy is a crucial step towards reducing carbon footprint, it is also not straightforward. This paper introduces the main considerations necessary for making sound use of energy measurement tools and interpreting energy estimates, including the use of at-the-wall versus on-device measurements, sampling strategies and best practices, common sources of error, and proxy measures. It also contains practical tips and real-world scenarios that illustrate how these considerations come into play. It concludes with a call to action for improving the state of the art of measurement methods and standards for facilitating robust comparisons between diverse hardware and software environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Programmable delay device enabling large delay in small package

A programmable delay device that provides delays of more than 100 ns over a broad bandwidth is disclosed. The device includes an input stage that employs M sampling switched capacitor elements such that each sampling switched capacitor element samples at a rate of only 1/M of the fundamental sampling rate. The device includes a programmable delay stage with M programmable switched capacitor banks, each programmable switched capacitor bank having N delay switched capacitor storage elements. Thus, the programmable delay stage includes a total of M×N delay switched capacitor storage elements, thereby reducing the sampling rate by a factor of M×N. This reduced sampling rate permits much smaller sampling switches, resulting in reduced leakage current and enabling far longer programmable delay times. Lastly, the device includes an output reconstruction stage that reconstructs a delayed version of the input RF signal by combining signals from the programmable delay stage.

Forbes, Travis↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Integration of multiple coinflip devices for high-quality random sampling

Artificial intelligence, scientific computing, and probabilistic computing use random sampling to approximate solutions to various problems, with larger models requiring a substantial quantity of random numbers. To generate the required vast quantity of random numbers at high rates, we explore so-called “coinflip” devices, which are stochastic microelectronic devices ideally capable of independently generating random bits with a tunable weight at a high rate. However, coinflip devices are inherently analog and demonstrate nonidealities, like temperature dependence and drift, that can introduce determinism into the outputs. We present important considerations for building systems of multiple coinflip devices to produce high-quality bitstreams with low error and little dependency on previous bits. Using tunnel diodes as coinflip devices, we implement a control loop to adapt to temperature dependence and generate fair bitstreams with each device. While this can lead to dependencies between bits in a single bitstream, we demonstrate that combining results generated in parallel with individual tunnel diodes can produce fair and unpredictable bitstreams. The suitability of these bitstreams for use in probabilistic computing is then demonstrated through a Monte Carlo approximation of π.

Taylor, Brady Garland [Sandia National Laboratorie↗

Stability of Cu(In x Ga 1− x )Se 2 Solar Cells Utilizing RbF Postdeposition Treatment under a Sulfur Atmosphere

Alkali halide postdeposition treatments (PDTs) have become a key tool to maximize efficiency in Cu(In x Ga 1− x )Se 2 (CIGS) photovoltaics. RbF PDTs have emerged as an alternative to the more common Na‐ and K‐based techniques. This study utilizes temperature‐dependent current–voltage ( JVT ) measurements to study a unique RbF PDT performed in a S atmosphere. The samples are measured before and after 6 months in a desiccator to study device stability. Both samples contain Na and K which diffuse from the soda–lime glass substrate. A reference sample and a RbF + S PDT sample both show the development of a rear contact barrier after aging. The contact barrier is higher for the RbF + S PDT sample, leading to decreased current in forward bias. Series resistance is also higher in the RbF + S PDT device which leads to lower fill factor. However, after aging the reference sample has a larger decrease in open‐circuit voltage ( V OC ). Ideality factor measurements suggest Shockley–Read–Hall recombination dominates both samples. V OC versus temperature and a temperature‐dependent activation energy model are used to calculate diode activation energies for each sample condition. Both techniques produce similar values that indicate recombination primarily occurs within the bulk absorber.

14 SOLAR ENERGY↗

Disruption event characterization and forecasting in tokamaks

Disruption prediction and avoidance is a critical need for next-step tokamaks, such as ITER. Disruption Event Characterization and Forecasting (DECAF) research fully automates analysis of tokamak data to determine chains of events that lead to disruptions and to forecast their evolution allowing sufficient time for mitigation or complete avoidance of the disruption. Disruption event chains related to local rotating or global magnetohydrodynamic (MHD) modes and vertical instability are examined with warnings issued for many off-normal physics events, including density limits, plasma dynamics, confinement transitions, and profile variations. Along with Greenwald density limit evaluation, a local radiative island power balance theory is evaluated and compared to the observation of island growth. Automated decomposition and analysis of rotating tearing modes produce physical event chains leading to disruptions. A total MHD state warning model comprised of 15 separate criteria produces a disruption forecast about 180 ms before a standard locked mode detector warning. Single DECAF event analyses have begun on KSTAR, MAST, and NSTX/-U databases with thousands of shot seconds of device operation using from 0.5 to 1 × 10 6 tested sample times per device. An initial multi-device database comparison illustrates a highly important result that plasma disruptivity does not need to increase as βN increases. Global MHD instabilities, such as resistive wall modes (RWMs), can give the briefest time period of warning before disruption compared to other physics events. In an NSTX database with unstable RWMs, the mode onset, loss of boundary and current control, and disruption event warnings are found in all cases and vertical displacement events are found in 91% of cases. An initial time-dependent reduced physics model of kinetic RWM stabilization created to forecast the disruption chain predicts instability 84% of the time for experimentally unstable cases with a relatively low false positive rate. Instances of the disruption event chain analysis illustrate dynamics including H–L back transitions for rotating MHD and global RWM triggering events. Furthermore, disruption warnings are issued with sufficient time before the disruption (on transport timescales) to potentially allow active profile control for disruption avoidance, active mode control, or mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Apparatus and methods for sample analysis with multi-gradient microfluidics

A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.

Kim, Peter Wonhee↗

Differential multi-probe thermal transport measurements of multi-walled carbon nanotubes grown by chemical vapor deposition

Carbon nanotubes (CNTs) are quasi-one dimensional nanostructures that display both high thermal conductivity for potential thermal management applications and intriguing low-dimensional phonon transport phenomena. In comparison to the advances made in the theoretical calculation of the lattice thermal conductivity of CNTs, thermal transport measurements of CNTs have been limited by either the poor temperature sensitivity of Raman thermometry technique or the presence of contact thermal resistance errors in sensitive two-probe resistance thermometry measurements. Here we report advances in a multi-probe measurement of the intrinsic thermal conductivity of individual multi-walled CNT samples that are transferred from the growth substrate onto the measurement device. The sample-thermometer thermal interface resistance is directly measured by this multi-probe method and used to model the temperature distribution along the contacted sample segment. The detailed temperature profile helps to eliminate the contact thermal resistance error in the obtained thermal conductivity of the suspended sample segment. A differential electro-thermal bridge measurement method is established to enhance the signal-to-noise ratio and reduce the measurement uncertainty by over 40%. The obtained thermal resistances of multiple suspended segments of the same MWCNT samples increase nearly linearly with increasing length, revealing diffusive phonon transport as a result of phonon-defect scattering in these MWCNT samples. The measured thermal conductivity increases with temperature and reaches up to 390 ± 20 W m –1 K –1 at room temperature for a 9-walled MWCNT. In conclusion, theoretical analysis of the measurement results suggests submicron phonon mean free paths due to extrinsic phonon scattering by extended defects such as grain boundaries. The obtained thermal conductivity is decreased by a factor of 3 upon electron beam damage and surface contamination of the CNT sample.

42 ENGINEERING↗