Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillator characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Initial measurement of reactor antineutrino oscillation at SNO+

The SNO+ collaboration reports its first spectral analysis of long-baseline reactor antineutrino oscillation using 114 tonne-years of data. Fitting the neutrino oscillation probability to the observed energy spectrum yields constraints on the neutrino mass-squared difference Δ$m^2_{21}$. In the ranges allowed by previous measurements, the best-fit Δ$m^2_{21}$ is ($8.85^{+1.10}_{-1.33}$) × 10 -5 eV 2 . This measurement is continuing in the next phases of SNO+ and is expected to surpass the present global precision on Δ$m^2_{21}$ with about three years of data. In the following, we first describe the configuration of the SNO+ detector when it was partially filled with scintillator, and a characterization of the detector response using intrinsic radioactivity. Next, we detail the event selection and expectations for reactor IBDs and (α, n) reactions. Then, we present the results of an energy spectrum analysis using 114 tonne-years of data. We conclude with prospects of future results from the SNO+ detector, which has been operating fully-filled with 780 tonnes of scintillator

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characterization of a Lens-Coupled System for Dynamic X-Ray Diffraction

X-ray diffraction (XRD) is a necessary technique for understanding states of materials under static and dynamic loading conditions. The higher-pressure Equation of State (EOS) of many materials can only be explored via shock or ramp compression at temperatures and pressures of interest. While static XRD work has yielded EOS measurements in the 100 - 200 GPa regime, dynamic X-ray diffraction (DXRD) can explore EOS phases in the TPa regime, which closely resembles inner-core planetary conditions. DXRD hinges on the ability to measure the exact phase or phase change of a material while under dynamic loading conditions. Macroscopic diagnostic systems (e.g. velocimetry and pyrometry) can infer a phase change but not identify the specific phase entered by a material. While microscopic (atomic-level) diagnostic systems (e.g. DXRD) have been designed and implemented in Department of Energy’s (DOE) National Laboratories complex, the unique nature of Sandia National Laboratories’ Pulsed Power Facility (Z Machine) prohibits the use of such devices. The destructive nature of Z experiments presents a challenge to data capture and retrieval. Furthermore there are electromagnetic interference, X-ray background, and mechanical constraints to consider. Thus, a multi-part X-ray diagnostic for use on the Z Machine and Z-Beamlet Laser system has been designed and analyzed. Portions of this new DYnamic SCintillator Optic (DYSCO) have been built, tested and fielded. A data analysis software has been written. Finally, the radiance profile of the DYSCO’s scintillator has been characterized through experiments performed at the University of Arizona.

36 MATERIALS SCIENCE↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

Crystal Growth and Characterization of Europium-Doped Rubidium Calcium Bromide Scintillators

National security strategies like gamma spectroscopy and high-energy X-ray radiography are limited, in part, by the scintillator used, prompting research into novel materials with improved properties. In this paper, Eu 2+ activated rubidium calcium bromide scintillators were grown via the vertical Bridgman method with a range of dopant concentrations. Light yield, energy resolution, and the afterglow of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu improved with increasing Eu 2+ concentration, and scintillation decay time increased. The highest light yields of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu were 71000 and 45000 ph/MeV, respectively.

36 MATERIALS SCIENCE↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Liquid Argon Scintillation Light Properties by means of an Alpha Source placed inside the CERN 10-PMT LAr Detection System

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter dewar filled with liquid argon and equipped with an extendible feed-through and mechanical support for an alpha source (241Am). The position of the source can be changed with respect to the PMT plane in vertical and horizontal directions. Arrays of silicon photomultiplier (SiPM) photodetectors, integrated in the source support, are used for the data acquisition trigger and to define the t0 of the light generation. PMT and SiPM signals can be recorded at different distances and different positions allowing the measurement of some of the LAr scintillation light properties. The system was studied and characterized in detail, and physics results on LAr scintillation properties are expected soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of Missing Energy due to Nuclear Effects in Monoenergetic Neutrino Charged-Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from 𝐾 + → 𝜇 + ⁢𝜈 𝜇 decay at rest (𝐸 𝜈 𝜇 = 235.5 MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly 𝜈 𝜇 ⁢𝑛 → 𝜇 − ⁢𝑝 or 𝜈 𝜇 ⁢ 12 C → 𝜇 − ⁢ 12 N, we define the missing energy as the energy transferred to the nucleus (𝜔) minus the kinetic energy of the outgoing proton(s), 𝐸 𝑚 ≡ 𝜔−∑ 𝑇 𝑝 , and relate this to visible energy in the detector, 𝐸 𝑚 = 𝐸 𝜈 𝜇 ⁡(235.5 MeV) − 𝑚 𝜇⁡ (105.7 MeV) + [𝑚 𝑛 − 𝑚 𝑝⁡ (1.3 MeV)] − 𝐸 vis . The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g., nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a (77 ± 3)% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements, and Type-II supernova studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed Material Scintillator Systems Particle ID Modelling Report

AMixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators. This report contains results from this project’s second task, to model and quantify the promise of the MMSSs invented earlier in the project. Those inventions have been divided into two categories, and this report focuses on the first category: MMSS inventions the use zones of differently-colored scintillators to detect and characterize neutron sources. We call this category particle-ID, or PID, detectors. Inventions using gradients designed to encode the position of radiation interactions using gradients will be discussed in a future report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Long-length Scintillating Fibers for Nuclear Waste Repositories (Conference Record)

This paper describes the fabrication, testing, and characterization of long-length, up to 50 m, scintillating fibers for the purpose of radiation monitoring in inaccessible radiological and nuclear waste repositories. The fabrication aspect was focused on ruggedizing the 1-mm diameter fiber and limiting external light interference for fibers. Testing and characterization were performed in a laboratory setting with radiation sources, a photosensor module and a multi-channel analyzer. Light attenuation was studied as a function of distance by analyzing both the spectrum and count rate. Additionally, the scintillating fibers were coupled to optical communication fibers (100 m) to extend the reach of the system. This paper also includes the optical spectrometry results from the sensitivity and response of the signal attenuation. Lastly, the paper covers the field testing of the scintillating fibers in a relevant environment.

47 - OTHER INSTRUMENTATION↗