Search NASA⌕ Search

SEARCH · Search NASA

Results for “Seebeck Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Magnetic freeze-out and anomalous Hall effect in ZrTe 5

The ultra-quantum limit is achieved when a magnetic field confines an electron gas in its lowest spin-polarised Landau level. Here we show that in this limit, electron doped ZrTe 5 shows a metal-insulator transition followed by a sign change of the Hall and Seebeck effects at low temperature. We attribute this transition to a magnetic freeze-out of charge carriers on the ionized impurities. The reduction of the charge carrier density gives way to an anomalous Hall response of the spin-polarised electrons. This behavior, at odds with the usual magnetic freeze-out scenario, occurs in this Dirac metal because of its tiny Fermi energy, extremely narrow band gap and a large g-factor. We discuss the different possible sources (intrinsic or extrinsic) for this anomalous Hall contribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-Dependent Thermoelectric Power of Nanoislands

The Seebeck effect explains the generation of electric voltage as a result of a temperature gradient. Its efficiency, defined as the ratio of the generated electric voltage to the temperature difference, is sensitive to local inhomogeneities that alter the scattering rate and the density of the conduction electrons. Spin-polarized Seebeck tunneling generates a distinct thermovoltage in spin-up and spin-down charge transport channels, which, as a key to spin caloritronics, focuses on transport phenomena related to spin and heat. Here, we report spatially resolved measurement of the spin-dependent thermovoltage in a tunneling junction formed by ferromagnetic Co nanoislands and a Ni tip using spin-dependent scanning tunneling thermovoltage microscopy (SP-STVthM). We resolve the nanoscale thermoelectric powers with respect to spin polarization, nanoisland size, stacking order of Co layers on a Cu substrate, and local sample heterogeneities. The observed thermally generated spin voltages are supported by first-principles and model calculations.

36 MATERIALS SCIENCE↗

Magnon spin current from a non-collinear magnetic phase in a compensated rare earth ferrimagnet

The rare earth iron garnets have been commonly treated like ferromagnets due to the strong exchange coupling between the Fe3+ sublattices. However, the exchange coupling between the rare earth (RE) and transition metal (TM) in the RE-TM compounds is relatively weak and cannot hold the magnetic moments rigidly in a collinear state upon effective anisotropy energy. In this work, we show that a non-collinear magnetic phase is readily presented for a rare earth ferrimagnetic insulator, gadolinium iron garnet (GdIG), when a small magnetic field (H) is applied in the hard axis. We excite magnons from both the collinear and non-collinear magnetic configuration in GdIG via the spin Seebeck effect and detect these magnons in the adjacent normal metal. The comparison between the collinear and non-collinear magnetic configurations reveals a comparable magnon compensating temperature (TMM) for both cases. Moreover, as temperature decreases, the in-plane component of the magnon from the non-collinear case enhances and becomes comparable with that of the collinear case at TMM, representing the dominant role Gd3+ 4f spin plays at low T. Our study shows a wide magnetic tunability in the compensated ferrimagnetic insulator, which offers a myriad of opportunities for magnonic applications.

Physics↗

Leveraging Sequential Doping of Semiconducting Polymers to Enable Functionally Graded Materials for Organic Thermoelectrics

With the ability to modulate electronic properties through molecular doping coupled with ease in processability, semiconducting polymers are at the forefront in enabling organic thermoelectric devices for thermal energy management. In contrast to uniform thermoelectric material properties, an alternative route focuses on functionally graded materials (FGMs) where one spatially controls and optimizes transport properties across the length of a thermoelectric material. While primarily studied in the context of inorganic materials, the concept of FGMs for organic thermoelectrics has not been explored. Herein, we introduce how molecular doping of semiconducting polymers enables spatial compositional control of thin-film FGMs. Specifically, we utilize sequential vapor doping of poly[2,5-bis(3-tetradecylthiophen-2-yl) thieno [3,2-b]thiophene] (PBTTT) with the small molecule acceptor 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ) to fabricate the simplest form of FGMs – double- segmented thin films. The two thin-film segments are of equal length (7.5 mm), but each set to different doping levels. Our study focuses on understanding the thermoelectric properties (Seebeck coefficient, α, and electronic conductivity, σ) and structural properties (through X-ray scattering, UV-vis-NIR spectroscopy, and Raman spectroscopy) within and across the two segments. We observe the presence of a small diffuse interfacial region of 0.5 – 1 mm between the two segments where the doping level and transport properties vary continuously. Despite the diffuse interface, the measured effective Seebeck coefficient (αeff) across the two segments is simply the average of α within each segment. Importantly, this experimental result is consistent with reported mathematical models describing αeff in graded thermoelectric materials. Finally, our results demonstrate the facile fabrication and characterization of functionally graded organic thermoelectric materials, providing guidelines for further development on more complex FGMs.

36 MATERIALS SCIENCE↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Large magnon-induced anomalous Nernst conductivity in single-crystal MnBi

Thermoelectric modules are a promising approach to energy harvesting and efficient cooling. In addition to the longitudinal Seebeck effect, transverse devices utilizing the anomalous Nernst effect (ANE) have recently attracted interest. For high conversion efficiency, it is required that the material have a large ANE thermoelectric power and low electrical resistance, which lead to the conductivity of the ANE. ANE is usually explained in terms of intrinsic contributions from Berry curvature. Our observations suggest that extrinsic contributions also matter. Studying single-crystal manganese-bismuth (MnBi), we find a high ANE thermopower (~10 μV/K) under 0.6 T at 80 K, and a transverse thermoelectric conductivity of over 40 A/Km. With insight from theoretical calculations, we attribute this large ANE predominantly to a new advective magnon contribution arising from magnon-electron spin-angular momentum transfer. We propose that introducing a large spin-orbit coupling into ferromagnetic materials may enhance the ANE through the extrinsic contribution of magnons.

36 MATERIALS SCIENCE↗

Conformal High-Power-Density Half-Heusler Thermoelectric Modules: A Pathway toward Practical Power Generators

Thermoelectric generators (TEGs) exploiting the Seebeck effect provide a promising solution for waste heat recovery. Among the large number of thermoelectric (TE) materials, half-Heusler (hH) alloys are leading candidates for medium- to high-temperature power generation applications. However, the fundamental challenge in this field has been inhomogeneous material properties at large wafer diameters, insufficient power output from the modules, and rigid form factors of TE modules. This has restricted the transition of TEGs in practical applications for over three decades. Here, we successfully demonstrate large diameter wafers with uniform TE properties, high-power conformal hH TE modules for high-temperature application, and their direct integration on flue gas platforms, such as cylindrical tubes, to form large area flexible TEGs. This new conformal architecture design provides a breakthrough toward medium-/high-temperature TEGs over the conventional BiTe- and polymer-based flexible TEG design. In this work, a variable fill factor and greater flexibility due to the conformal design result in higher device performance as compared to conventional rigid TEG devices. Modules with 72-couple hH legs exhibit a device high-power-density of 3.13 W cm-2 and a total output power of 56.6 W under a temperature difference of 570 degrees C. These results provide a promising pathway toward widespread utilization of thermoelectric technology into the waste heat recovery application and will have a significant impact on the development of practical thermal to electrical converters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flat epitaxial quasi-1D phosphorene chains

The emergence of peculiar phenomena in 1D phosphorene chains (P chains) has been proposed in theoretical studies, notably the Stark and Seebeck effects, room temperature magnetism, and topological phase transitions. Attempts so far to fabricate P chains, using the top-down approach starting from a few layers of bulk black phosphorus, have failed to produce reliably precise control of P chains. We show that molecular beam epitaxy gives a controllable bottom-up approach to grow atomically thin, crystalline 1D flat P chains on a Ag(111) substrate. Scanning tunneling microscopy, angle-resolved photoemission spectroscopy, and density functional theory calculations reveal that the armchair-shaped chains are semiconducting with an intrinsic 1.80 ± 0.20 eV band gap. This could make these P chains an ideal material for opto-electronic devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Third harmonic characterization of antiferromagnetic heterostructures

Abstract Electrical switching of antiferromagnets is an exciting recent development in spintronics, which promises active antiferromagnetic devices with high speed and low energy cost. In this emerging field, there is an active debate about the mechanisms of current-driven switching of antiferromagnets. For heavy-metal/ferromagnet systems, harmonic characterization is a powerful tool to quantify current-induced spin-orbit torques and spin Seebeck effect and elucidate current-induced switching. However, harmonic measurement of spin-orbit torques has never been verified in antiferromagnetic heterostructures. Here, we report harmonic measurements in Pt/ α -Fe 2 O 3 bilayers, which are explained by our modeling of higher-order harmonic voltages. As compared with ferromagnetic heterostructures where all current-induced effects appear in the second harmonic signals, the damping-like torque and thermally-induced magnetoelastic effect contributions in Pt/ α -Fe 2 O 3 emerge in the third harmonic voltage. Our results provide a new path to probe the current-induced magnetization dynamics in antiferromagnets, promoting the application of antiferromagnetic spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The elphbolt ab initio solver for the coupled electron-phonon Boltzmann transport equations

elphbolt is a modern Fortran (2018 standard) code for efficiently solving the coupled electron–phonon Boltzmann transport equations from first principles. Using results from density functional and density functional perturbation theory as inputs, it can calculate the effect of the non-equilibrium phonons on the electronic transport (phonon drag) and non-equilibrium electrons on the phononic transport (electron drag) in a fully self-consistent manner and obeying the constraints mandated by thermodynamics. It can calculate the lattice, charge, and thermoelectric transport coefficients for the temperature gradient and electric fields, and the effect of the mutual electron–phonon drag on these transport properties. The code fully exploits the symmetries of the crystal and the transport-active window to allow the sampling of extremely fine electron and phonon wave vector meshes required for accurately capturing the drag phenomena. The corray feature of modern Fortran, which offers native and convenient support for parallelization, is utilized. The code is compact, readable, well-documented, and extensible by design.

electron drag↗

Spin current generation and detection in uniaxial antiferromagnetic insulators

Spin current represents a flow of spin angular momentum and does not require movement of charges. Magnetic insulators can therefore work as a source as well as a medium of spin currents, which has been established in ferrimagnetic insulators. Here, we report recent progress in the generation and electrical detection of spin currents in uniaxial antiferromagnetic insulators carried by antiferromagnetic magnons, both thermally and resonantly excited, respectively, via the spin Seebeck effect and antiferromagnetic spin pumping by subterahertz microwaves. These findings open up many exciting possibilities of potential antiferromagnetic applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A perspective on two-dimensional van der Waals opto-spin-caloritronics

Two-dimensional (2D) van der Waals magnetic semiconductors displaying controllable ferromagnetism at room temperature form atomically sharp interfaces with various substrates. Such heterostructures create platforms for understanding spin-dependent phenomena across interfaces and surfaces for high-performance technological applications. Combining these 2D magnets with light and the spin Seebeck effect (SSE) in-state-of-the-art thermo-opto-spin studies forms a new paradigm in the field of spin-caloritronics that harnesses light as the new heat. In this Perspective, we detail how to exploit recent advances in 2D van der Waals materials to boost the SSE and propose a new strategy for optically controlled SSE in 2D magnetic semiconductor-based heterostructures with the intent to establish the research thrust of “opto-spin-caloritronics.”

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermally generated magnonic spin currents in a polycrystalline gadolinium iron garnet thin film with perpendicular magnetic anisotropy

Rare-earth iron garnets (REIGs) are the benchmark systems for magnonics, including the longitudinal spin Seebeck effect (LSSE). While most research has focused on single-crystalline REIGs on complimentary garnet substrates, moving to more, cost-effective complementary metal-oxide semiconductor (CMOS)-compatible substrates is important to integrate REIG thin films with existing technology. In this regard, we grow a 130 nm-thick polycrystalline gadolinium iron garnet (GdIG) film on the Si/SiO2 substrate and investigate the temperature-dependent LSSE. Interestingly, the polycrystalline GdIG film exhibits perpendicular magnetic anisotropy (PMA) at room temperature which is induced by tensile in-plane (IP)-strain originating from the thermal-expansion mismatch between the GdIG film and the substrate during rapid thermal annealing. Further, a spin-reorientation transition from the out-of-plane IP direction below TS = 180 K is observed. Additionally, the film reveals a magnetic compensation temperature, TComp, of ≈240 K. The LSSE voltage not only demonstrates a sign-inversion around TComp, but also shows noticeable changes around TS. As compared to a single-crystalline GdIG film, the lower LSSE voltage for the polycrystalline GdIG is attributed to the higher effective magnetic anisotropy and enhanced magnon scattering at the grain boundaries. Our study not only paves the way for the cost-effective growth of CMOS-compatible REIG-based systems with PMA for magnonic memory and information processing applications, but also highlights the fact that the spincaloritronic and spin-insulatronic properties of the polycrystalline REIGs follow those of their single-crystalline counterparts with reduced spin-to-charge conversion efficiency through LSSE which can be tuned further by controlling the average gran size and interface engineering.

Physics↗

Spontaneous Nernst effect in the iron-based superconductor Fe 1+y Te 1–x Se x

We present a study of the Nernst effect in an iron-based superconductor with a nontrivial band topology Fe 1+y Te 1–x Se x . A nonzero Nernst signal is observed in a narrow temperature region around the superconducting transition temperature Tc at a zero field. This anomalous Nernst signal shows symmetric dependence on the external magnetic field and indicates an unconventional vortex contribution in an s-wave superconductor with a strong spin-orbit coupling, which is originated from the local magnetic moments of the interstitial Fe atoms. Furthermore, our experiments also provide the first evidence of a locally broken time-reversal symmetry in bulk Fe 1+y Te 1–x Se x single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Magnon Polarization

We measure the mode-resolved direction of the precessional motion of the magnetic order, i.e.,magnon polarization, via the chiral term of inelastic polarized neutron scattering spectra. The magnon polarization is a unique and unambiguous signature of magnets and is important in spintronics, affecting thermodynamic properties such as the magnitude and sign of the spin Seebeck effect. However, it has never been directly measured in any material until this work. The observation of both signs of magnon polarization in Y 3 Fe 5 O 12 also gives direct proof of its ferrimagnetic nature. The experiments agree very well with atomistic simulations of the scattering cross section.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ORNL Design Engineering Library: Validated Thermoelectric Digital Twins

Radioisotope thermoelectric generators (RTGs) serve a crucial role in supplying thermal and electrical energy for reliable and long-duration power in remote and extreme environments. The thermal energy is provided by the decay of radioisotopes and is converted into electrical energy using the steady-state thermoelectric process by exploiting the Seebeck effect. Maintaining a thermal gradient through the material is necessary to drive current production. Modern predictive multi-physics tools are able to effectively describe the complex and strongly coupled phenomena needed for accurate model-based system engineering efforts needed to develop higher performing RTGs. Experimental validation of model simulations is essential to confirm the accuracy, reliability, and applicability of predictive multiphysics tools. Validation fosters confidence among users, helps meet regulatory requirements, and contributes to the ongoing improvement of simulation techniques, ultimately leading to better, safer, and more efficient designs and processes. Validated models can then be used as digital twins and can be interrogated to understand and quantify the performance gaps between theoretical and physical systems. These insights can be used to build higher performing systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Anomalous Nernst and Seebeck coefficients in epitaxial thin film Co 2 MnAl x Si 1 - x and Co 2 FeAl

Here we have measured the Seebeck and anomalous Nernst coefficients and corresponding transverse and longitudinal thermoelectric conductivities from 2 to 400 K in thin film (thickness t ~10 nm) Co 2 MnAl x Si 1-x (0 ≤ x ≤ 1) and Co 2 FeAl grown by molecular beam epitaxy (MBE). A large (-14 A m -1 K -1 at 300 K) anomalous component of the transverse thermoelectric conductivity is observed in Co 2 MnAl, especially as contrasted to Co 2 MnSi (0.28 A m -1 K -1 at 300 K). This enhancement is likely due to Weyl points close to the Fermi level of Co 2 MnAl which disappear as x decreases.

36 MATERIALS SCIENCE↗