Search NASA⌕ Search

SEARCH · Search NASA

Results for “Selectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automatic PCM guard-band selector and calibrator

Automatic method for selection of proper guard band eliminates human error and speeds up calibration process. There is also an option which allows a single channel to be calibrated, independently of other channels. Entire system is designed on 3- by 4-inch printed-circuit cards and may be used with any pulse code modulation system.

Noda, T. T.↗

Multiband Selector for Linear Photodetector Array

Line image observed simultaneously in two or more spectral bands. Incoming light focused through beam splitter onto two linear arrays of photodetectors to form line images. Array of band-pass filters above each detector array positioned to select spectral band of line image. These capabilities are valuable in such multispectral-imaging applications as spaceborne and airborne visible and infrared observation of Earth for geology, oil and mineral exploration, biomass distribution, forestry, agriculture, and urban and rural development.

Richard, H. L.↗

Plug-In RF Selector Switch

Short, direct link between switch and filters reduces signal loss. New switch attaches directly to filter housing, eliminating cables and connectors. As result, losses in transmitter and receiver paths reduced by about 0.4 dB. Because connectors and cables are not used, RF path loss for selected signal through switch and filter is smaller than usual.

Hwon, A. H.↗

Speed-Selector Guard For Machine Tool

Simple guardplate prevents accidental reversal of direction of rotation or sudden change of speed of lathe, milling machine, or other machine tool. Custom-made for specific machine and control settings. Allows control lever to be placed at only one setting. Operator uses handle to slide guard to engage or disengage control lever. Protects personnel from injury and equipment from damage occurring if speed- or direction-control lever inadvertently placed in wrong position.

Shakhshir, Roda J.↗

Device Selector

Explore the source record for details and available documents.

Slettenhaar, H.↗

Chemiresistors for the Real‐Time Wireless Detection of Anions

Abstract Reported is an electrical transduction platform for real‐time wireless anion sensing using single‐walled carbon nanotubes (SWCNTs) noncovalently functionalized with squaramide‐based anion binding selectors. Systematically studied are anion‐binding properties and efficiency of the electrical transduction of the functionalized SWCNT composites using the squaramide‐based selectors with two similar electron‐withdrawing groups, 3,5‐bis(trifluoromethyl)benzyl ( 1 ) and 3,5‐bis(trifluoromethyl)phenyl ( 2 ), which induce hydrogen‐bonding interaction with anions and deprotonation of a squaramide N–H proton upon addition of acetate (AcO − ), respectively. Charge transduction occurs with AcO − as a result of charge transfer from the deprotonated selector 2 , whereas less sensitive transduction is observed with selector 1 via hydrogen‐bonding interaction. These results provide guidelines to efficiently transduce the chemical interaction between selectors and anions to create resistive transduction with functionalized SWCNTs. Electron‐withdrawing groups adjacent to the squaramide as well as proximate cationic pyridyl groups, enhance the anion binding affinity and also lower the selector's p K a . The chemiresistive sensor arrays are readily integrated with a wireless sensing module and demonstrated real‐time sensing of multiple anions with a smartphone readout.

Choi, Seon‐Jin↗

ThickBrick: optimal event selection and categorization in high energy physics. Part I. Signal discovery

We provide a prescription called ThickBrick to train optimal machine-learning-based event selectors and categorizers that maximize the statistical significance of a potential signal excess in high energy physics (HEP) experiments, as quantified by any of six different performance measures. For analyses where the signal search is performed in the distribution of some event variables, our prescription ensures that only the information complementary to those event variables is used in event selection and categorization. This eliminates a major misalignment with the physics goals of the analysis (maximizing the significance of an excess) that exists in the training of typical ML-based event selectors and categorizers. In addition, this decorrelation of event selectors from the relevant event variables prevents the background distribution from becoming peaked in the signal region as a result of event selection, thereby ameliorating the challenges imposed on signal searches by systematic uncertainties. Our event selectors (categorizers) use the output of machine-learning-based classifiers as input and apply optimal selection cutoffs (categorization thresholds) that are functions of the event variables being analyzed, as opposed to flat cutoffs (thresholds). These optimal cutoffs and thresholds are learned iteratively, using a novel approach with connections to Lloyd’s k-means clustering algorithm. We provide a public, Python implementation of our prescription, also called ThickBrick, along with usage examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective acetate recognition and sensing using SWCNTs functionalized with croconamides

Croconamides are a new class of dual-hydrogen bond donors that have attracted interest in anion recognition and sensing applications due to their strong H-bond donation capability. In this work, we report chemiresistive sensors for the detection of anions based on poly(4-vinylpyridine) (P4VP)-wrapped single-walled carbon nanotubes (SWCNTs) functionalized with croconamide-based selectors. Model structures of asymmetric N,N-substituted croconamide selectors with N,N-substitutional groups of alkyl cationic pyridinium and electron-withdrawing moieties such as aniline (6) and 3,5-bis(trifluoromethyl)phenyl (7) groups were synthesized and their binding affinities for various anions were characterized using UV–vis and 1 H NMR titrations. Switchable binding of oxoanions was observed with selector 7, wherein HSO 4 – formed hydrogen bonding interactions and acetate (AcO – ) induced deprotonation of the NH- protons of the croconamide. Large sensitivity transitions were obtained toward AcO – for both P4VP-6-SWCNT (S = 95.68 ± 2.11 %) and P4VP-7-SWCNT (S = 140.91 ± 3.68 %) at 83.33 mM, which was attributed to deprotonation of the croconamide selectors upon addition of AcO – . In conclusion, three serial sensors were assembled in a sensor array that rapid and selective screening of AcO – was demonstrated against other oxoanions such as HSO 4 – and H 2 PO 4 – in real-time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

A Platform for Ultra-Fast Proton Probing of Matter in Extreme Conditions

Recent developments in ultrashort and intense laser systems have enabled the generation of short and brilliant proton sources, which are valuable for studying plasmas under extreme conditions in high-energy-density physics. However, developing sensors for the energy selection, focusing, transport, and detection of these sources remains challenging. This work presents a novel and simple design for an isochronous magnetic selector capable of angular and energy selection of proton sources, significantly reducing temporal spread compared to the current state of the art. The isochronous selector separates the beam based on ion energy, making it a potential component in new energy spectrum sensors for ions. Analytical estimations and Monte Carlo simulations validate the proposed configuration. Due to its low temporal spread, this selector is also useful for studying extreme states of matter, such as proton stopping power in warm dense matter, where short plasma stagnation time (<100 ps) is a critical factor. The proposed selector can also be employed at higher proton energies, achieving final time spreads of a few picoseconds. This has important implications for sensing technologies in the study of coherent energy deposition in biology and medical physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inductively powered power bus apparatus

An apparatus for a power bus includes an inductive power harvesting unit structured to provide a first power output arising from current flowing in the power bus, an energy storage unit structured to store energy from the first power output and to provide a second power output, and a selector structured to select one of the first and second power outputs and to provide a third power output from the selected one. A processor is powered from the third power output of the selector. The selector is further structured to normally provide the third power output from the first power output of the inductive power harvesting unit. The processor is structured to determine that the first power output of the inductive power harvesting unit is inadequate and to cause the selector to provide the third power output from the second power output of the energy storage unit.

42 ENGINEERING↗

Adaptive strategies for materials design using uncertainties

Here, we compare several adaptive design strategies using a data set of 223 M2AX family of compounds for which the elastic properties [bulk (B), shear (G), and Young’s (E) modulus] have been computed using density functional theory. The design strategies are decomposed into an iterative loop with two main steps: machine learning is used to train a regressor that predicts elastic properties in terms of elementary orbital radii of the individual components of the materials; and a selector uses these predictions and their uncertainties to choose the next material to investigate. The ultimate goal is to obtain a material with desired elastic properties in as few iterations as possible. We examine how the choice of data set size, regressor and selector impact the design. We find that selectors that use information about the prediction uncertainty outperform those that don’t. Our work is a step in illustrating how adaptive design tools can guide the search for new materials with desired properties.

36 MATERIALS SCIENCE↗

An accurate locally active memristor model for S-type negative differential resistance in NbO{sub x}

A number of important commercial applications would benefit from the introduction of easily manufactured devices that exhibit current-controlled, or “S-type,” negative differential resistance (NDR). A leading example is emerging non-volatile memory based on crossbar array architectures. Due to the inherently linear current vs. voltage characteristics of candidate non-volatile memristor memory elements, individual memory cells in these crossbar arrays can be addressed only if a highly non-linear circuit element, termed a “selector,” is incorporated in the cell. Selectors based on a layer of niobium oxide sandwiched between two electrodes have been investigated by a number of groups because the NDR they exhibit provides a promisingly large non-linearity. We have developed a highly accurate compact dynamical model for their electrical conduction that shows that the NDR in these devices results from a thermal feedback mechanism. A series of electrothermal measurements and numerical simulations corroborate this model. These results reveal that the leakage currents can be minimized by thermally isolating the selector or by incorporating materials with larger activation energies for electron motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chemical Method of Urine Volume Measurement

A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

QUANTITATIVE ANALYSIS↗

System for calibrating pressure transducer

A system for calibrating a pressure transducer which has a reference portion and an active portion is reported. A miniature selector valve is positioned immediately adjacent the pressure transducer. A reference pressure, known pressure, and unknown pressure can be selectively admitted to the active side of the pressure transducer by the selector valve to enable calibration of the transducer. A valve admits pressure to the selector valve which has a piston and floating piston arrangement which allows proper selection with very small linear movement.

Rollins, G. N.↗