Deposition of organic dyes for dye-sensitized solar cell by using matrix-assisted pulsed laser evaporation

The deposition of various distinct organic dyes, including ruthenium complex N3, melanin nanoparticle (MNP), and porphyrin-based donor-π-acceptor dye YD2-o-C8, by using matrix-assisted pulsed laser evaporation (MAPLE) for application to dye-sensitized solar cell (DSSC) is investigated systematically. It is found that the two covalently-bonded organic molecules, i.e., MNP and YD2-o-C8, can be transferred from the frozen target to the substrate with maintained molecular integrity. In contrast, N3 disintegrates in the process, presumably due to the lower bonding strength of metal complex compared to covalent bond. With the method, DSSC using YD2-o-C8 is fabricated, and an energy conversion efficiency of 1.47% is attained. The issue of the low penetration depth of dyes deposited by MAPLE and the possible resolution to it are studied. This work demonstrates that MAPLE could be an alternative way for deposition of organic dyes for DSSC.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hessian matrix approach for determining error field sensitivity to coil deviations.

The presence of error fields has been shown to degrade plasma confinement and drive instabilities. Error fields can arise from many sources, but are predominantly attributed to deviations in the coil geometry. In this paper, we introduce a Hessian matrix approach for determining error field sensitivity to coil deviations. A primary cost function used for designing stellarator coils, the surface integral of normalized normal field errors, was adopted to evaluate the deviation of the generated magnetic field from the desired magnetic field. The FOCUS code [Zhu et al., Nucl. Fusion 58(1):016008 (2018)] is utilized to provide fast and accurate calculations of the Hessian. The sensitivities of error fields to coil displacements are then determined by the eigenvalues of the Hessian matrix. A proof-of-principle example is given on a CNT-like configuration. We anticipate that this new method could provide information to avoid dominant coil misalignments and simplify coil designs for stellarators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Defect Detection in Additively Manufactured Lattice Structures Using 3D Electrical Resistance Tomography

Cellular lattice structures possess high strength-to-weight ratios suitable for advanced lightweight engineering applications. However, their quality and mechanical performance can degrade because of defects introduced during manufacturing or in-service. Their complexity and small length scale features make defects difficult to detect using conventional nondestructive evaluation methods. Here we propose a current injection-based method, electrical resistance tomography (ERT), that can be used to detect damaged struts in conductive cellular lattice structures with their intrinsic electromechanical properties. The reconstructed conductivity distributions from ERT can reveal the severity and location of damaged struts without having to probe each strut. However, the low central sensitivity of ERT may result in image artifacts and inaccurate localization of damaged struts. To address this issue, this study introduces an absolute, high throughput, conductivity reconstruction algorithm for 3D ERT. The algorithm incorporates a strut-based normalized sensitivity map to compensate for lower interior sensitivity and suppresses reconstruction artifacts. Numerical simulations and experiments on fabricated representative cellular lattice structures were performed to verify the ability of ERT to quantitatively identify single and multiple damaged struts. The improved performance of this method compared with classical ERT was observed, based on greatly decreased imaging and reconstructed value errors.

36 MATERIALS SCIENCE↗

An energy fluence-convolution model for amorphous silicon EPID dose prediction

In this work, an amorphous silicon electronic portal imaging device (a-Si EPID) dose prediction model based on the energy fluence model of the Pinnacle treatment planning system Version 7 (Philips Medical Systems, Madison, WI) is developed. An energy fluence matrix at very high resolution (<1 mm) is used to incorporate multileaf collimator (MLC) leaf effects in the predicted EPID images. The primary dose deposited in the EPID is calculated from the energy fluence using experimentally derived radially dependent EPID interaction coefficients. Separate coefficients are used for the open beam energy fluence component and the component of the energy fluence transmitted through closed MLC leaves to each EPID pixel. A spatially invariant EPID dose deposition kernel that describes both radiative dose deposition, central axis EPID backscatter, and optical glare is convolved with the primary dose. The kernel is further optimized to give accurate EPID penumbra prediction and EPID scatter factor with changing MLC field size. An EPID calibration method was developed to reduce the effect of nonuniform backscatter from the support arm (E-arm) in a calibrated EPID image. This method removes the backscatter component from the pixel sensitivity (flood field) correction matrix retaining only field-specific backscatter in the images. The model was compared to EPID images for jaw and MLC defined open fields and eight head and neck intensity modulated radiotherapy (IMRT) fields. For the head and neck IMRT fields with 2%, 2 mm criteria 97.6{+-}0.6% (mean {+-}1 standard deviation) of points passed with a gamma index less than 1, and for 3%, 3 mm 99.4{+-}0.4% of points were within the criteria. For these fields, the 2%, 2 mm pass score reduced to 96.0{+-}1.5% when backscatter was present in the pixel sensitivity correction matrix. The model incorporates the effect of MLC leaf transmission, EPID response to open and MLC leakage dose components, and accurately predicts EPID images of IMRT fields. Removing the backscatter component of the pixel sensitivity matrix correction reduces the effect of nonuniform E-arm backscatter.

61 RADIATION PROTECTION AND DOSIMETRY↗

Condition and Error Estimates in Numerical Matrix Computations

This tutorial paper deals with sensitivity and error estimates in matrix computational processes. The main factors determining the accuracy of the result computed in floating--point machine arithmetics are considered. Special attention is paid to the perturbation analysis of matrix algebraic equations and unitary matrix decompositions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Search for the Higgs Boson in the $ZH$ Dilepton Decay Channel at CDF II

This dissertation describes a search for the Standard Model Higgs boson produced in association with the Z boson via Higgs-strahlung at the CDF II detector at the Tevatron. At a Higgs boson mass between 100 GeV/c{sup 2} and 135 GeV/c{sup 2}, the primary Higgs decay mode is to a pair of b quarks. The associated Z boson can decay to a pair of electrons or muons, allowing detection of a final event signature of two visible leptons and two b quarks. This final state allows reduction of large QCD backgrounds compared to a hadronic Z boson decay, leading to a more sensitive search. To increase sensitivity, standard model matrix element probabilities for ZH signal and the dominant backgrounds are used as components to a likelihood fit in signal fraction. In 2.7 fb{sup -1} of CDF II data, we see no evidence of production of a Higgs boson with a mass between 100 GeV c{sup 2} and 150 GeV/c{sup 2}. Using the Feldman-Cousins technique to set a limit, at 95% coverage and a Higgs boson mass of 115 GeV/c{sup 2}, the median expected limit was 12.1 x {sigma}{sub SM} and a limit of 8.2 x {sigma}{sub SM} was observed, where {sigma}{sub SM} is the NNLO theoretical cross section of p{bar p} {yields}ZH {yields} l +l -b{bar b} at {radical}s=1.96 TeV . Cross section limits are computed at a range of Higgs boson mass values between 100 GeV/c {sup 2} and 150 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BRAVE_EBC-TMT.1.0

Exhaled breath condensate (EBC) represents a low-cost and non-invasive means of examining respiratory health. EBC has been used to discover and validate exhaled volatile and non-volatile biomarkers of disease related to the respiratory system distress such as asthma, COPD, lung cancer, and secondary infections. One newly emerging utilization of EBC, is proteomics analysis, which can provide an unbiased snapshot into ongoing biological processes in the airway. Fully characterizing the biological landscape of EBC collections is challenging though, due to sample variability, and low detection sensitivity. EBC is primarily composed of condensed water, causing technical challenges with detecting key macromolecules from the dilute sample matrix; therefore, high sensitivity techniques are required to unlock the full capability of EBC as a method for non-invasive biomarker detection. To overcome some of these technical challenges for proteomic analyses, we applied our recently developed microscale proteomic techniques and developed a novel TMT based approach which enabled reliable, relative quantification with significantly improved detection of low abundance peptides/proteins across multiple healthy volunteer EBC samples. Our EBC collection design includes longitudinal EBC collections from five individual healthy volunteers on three separate days of the week with triplicate, back-to-back donations each day. Here, we report a total of 235 quantifiable proteins corresponding to 1,877 non-redundant peptides for evaluating sample collection reproducibility and establishing a healthy (human host) baseline EBC biomarker proteome studies. This work will pave the way for further investigations of EBC protein expression profiles and showcase the value of using non-invasive collection method techniques for clinically relevant biomarker discovery. This research was supported by the LDRD Biomedical Resilience And Readiness in AdVerse Operating Environments (BRAVE) Project (73748), and was conducted at Pacific Northwest National Laboratory (PNNL) in Richland, WA. PNNL is a multiprogram national laboratory operated by Battelle for the Department of Energy (DOE) under Contract DE-AC05-76RLO 1830.

59 BASIC BIOLOGICAL SCIENCES↗

Oxygen-Induced Mechanical Property Variations of Rapidly Solidified Ti-Based Bulk Metallic Composites

In titanium-based metallic glass composites, a new kind of structural material, the presence of oxygen is an unavoidable problem. Since the amorphous matrix is very sensitive to oxygen, oxygen content must be carefully controlled during the manufacturing process. In this paper, the effects of oxygen on the microstructure and mechanical properties of Ti{sub 48}Zr{sub 20}Nb{sub 12}Cu{sub 5}Be{sub 15} metallic glass composite was studied. The results showed that even low concentrations of oxygen in the metallic glass composite are sufficient to significantly affect the strength, plasticity and working hardening ability without altering the microstructure of the composite on micron scale. Acceptable oxygen content ranges in Ti{sub 48}Zr{sub 20}Nb{sub 12}Cu{sub 5}Be{sub 15} metallic glass composites for practical applications can be determined by balancing the stability of the amorphous matrix and the strength and plasticity of the alloy.

36 MATERIALS SCIENCE↗

Materials science applications of Neutron Depth Profiling at the PGAA facility of Heinz Maier-Leibnitz Zentrum

Highlights: • Exploiting the range of NDP from thin films to electrodes for Li-ion batteries • Adopting an analytical method to probe undisturbed depth profiles from thick films • Revealing depth-dependent lithium immobilization in Li-ion battery electrodes Neutron depth profiling (NDP) is a non-destructive, isotope-sensitive profiling technique to monitor concentration profiles in almost any material matrix. Since NDP is sensitive to {sup 6}Li and lithium is widely used for different material science applications such as ceramics, optical waveguides or energy-storage systems, NDP offers answers to a broad spectrum of research questions. In the present work, the recently developed instrument N4DP at MLZ is used to address two research questions which are hardly accessible by conventional analytical techniques. First, the homogeneity of lithium formations within lithium niobate thin films for optical waveguide applications is investigated. Afterwards, the accumulation of inactive lithium in the solid-electrolyte-interphase (SEI) of silicon-graphite electrodes for lithium-ion batteries is studied ex situ. Since the material mass loading differs considerably between the two applications, a new analytical technique is introduced which mathematically separates the different particle signals and thus allows to investigate samples with high mass loadings.

36 MATERIALS SCIENCE↗

Quantitative shearography: error reduction by using more than three measurement channels

Shearography is a noncontact optical technique used to measure surface displacement derivatives. Full surface strain characterization can be achieved using shearography configurations employing at least three measurement channels. Each measurement channel is sensitive to a single displacement gradient component defined by its sensitivity vector. A matrix transformation is then required to convert the measured components to the orthogonal displacement gradients required for quantitative strain measurement. This transformation, conventionally performed using three measurement channels, amplifies any errors present in the measurement. This paper investigates the use of additional measurement channels using the results of a computer model and an experimental shearography system. Results are presented showing that the addition of a fourth channel can reduce the errors in the computed orthogonal components by up to 33% and that, by using 10 channels, reductions of around 45% should be possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phosphodiesterase (PDE5) inhibition assay for rapid detection of erectile dysfunction drugs and analogs in sexual enhancement products

Abstract Products marketed as dietary supplements for sexual enhancement are frequently adulterated with phosphodiesterase‐5 (PDE5) inhibitors, which are erectile dysfunction drugs or their analogs that can cause adverse health effects. Due to widespread adulteration, a rapid screening assay was developed to detect PDE5 inhibitors in adulterated products. The assay employs fluorescence detection and is based on measuring inhibition of PDE5 activity, the pharmacological mechanism shared among the adulterants. Initially, the assay reaction scheme was established and characterized, followed by analysis of 9 representative PDE5 inhibitors ( IC 50 , 0.4–4.0 ng mL –1 ), demonstrating sensitive detection in matrix‐free solutions. Next, dietary supplements serving as matrix blanks ( n = 25) were analyzed to determine matrix interference and establish a threshold value; there were no false positives. Finally, matrix blanks were spiked with 9 individual PDE5 inhibitors, along with several mixtures. All 9 adulterants were successfully detected (≤ 5 % false negative rate; n = 20) at a concentration of 1.00 mg g –1 , which is over 5 times lower than concentrations commonly encountered in adulterated products. A major distinction of the PDE5 inhibition assay is the ability to detect adulterants without prior knowledge of their chemical structures, demonstrating a broad‐based detection capability that can address a continuously evolving threat of new adulterants. The PDE5 inhibition assay can analyze over 40 samples simultaneously within 15 minutes and involves a single incubation step and simple data analysis, all of which are advantageous for combating the widespread adulteration of sex‐enhancement products.

Santillo, Michael F.↗

Structure–Thermodynamic Relationship of a Polysaccharide Gel (Alginate) as a Function of Water Content and Counterion Type (Na vs Ca)

Biofilms are the predominant mode of microbial life on Earth, and so a deep understanding of microbial communities-and their impacts on environmental processes-requires a firm understanding of biofilm properties. Because of the importance of biofilms to their microbial inhabitants, microbes have evolved different ways of engineering and reconfiguring the matrix of extracellular polymeric substances (EPS) that constitute the main non-living component of biofilms. This ability makes it difficult to distinguish between the biotic and abiotic origins of biofilm properties. An important route toward establishing this distinction has been the study of simplified models of the EPS matrix. This study builds on such efforts by using atomistic simulations to predict the nanoscale (≤10 nm scale) structure of a model EPS matrix and the sensitivity of this structure to interpolymer interactions and water content. To accomplish this, we use replica exchange molecular dynamics (REMD) simulations to generate all-atom configurations of ten 3.4 kDa alginate polymers at a range of water contents and Ca–Na ratios. Simulated systems are solvated with explicitly modeled water molecules, which allows us to capture the discrete structure of the hydrating water and to examine the thermodynamic stability of water in the gels as they are progressively dehydrated. Our primary findings are that (i) the structure of the hydrogels is highly sensitive to the identity of the charge-compensating cations, (ii) the thermodynamics of water within the gels (specific enthalpy and free energy) are, surprisingly, only weakly sensitive to cation identity, and (iii) predictions of the differential enthalpy and free energy of hydration include a short-ranged enthalpic term that promotes hydration and a longer-ranged (presumably entropic) term that promotes dehydration, where short and long ranges refer to distances shorter or longer than ~0.6 nm between alginate strands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirical probability and machine learning analysis of m , n = 2, 1 tearing mode onset parameter dependence in DIII-D H-mode scenarios

m, n = 2, 1 tearing mode onset empirical probability and machine learning analyses of a multiscenario DIII-D database of over 14 000 H-mode discharges show that the normalized plasma beta, the rotation profile, and the magnetic equilibrium shape have the strongest impact on the 2,1 tearing mode stability, in qualitative agreement with neoclassical tearing modes (m and n are the poloidal and toroidal mode numbers, respectively). In addition, 2,1 tearing modes are most likely to destabilize when n > 1 tearing modes are already present in the core plasma. The covariance matrix of tearing sensitive plasma parameters takes a nearly block-diagonal form, with the blocks incorporating thermodynamic, current and safety factor profile, separatrix shape, and plasma flow parameters, respectively. This suggests a number of paths to improved stability at fixed pressure and edge safety factor primarily by preserving a minimum of 1 kHz differential rotation, increasing the minimum safety factor above unity, using upper single null magnetic configuration, and reducing the core impurity radiation. In addition, lower triangularity, lower elongation, and lower pedestal pressure may also help to improve stability. Furthermore, the electron and ion temperature, collisionality, resistivity, internal inductance, and the parallel current gradient appear to only weakly correlate with the 2,1 tearing mode onsets in this database.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiquark matrix elements in the proton and three gluon exchange for exclusive $η_c$ production in photon-proton diffractive scattering

Exclusive production of a η c pseudoscalar meson in γ ( * ) + p → η c + p scattering at high energies involves a C -odd exchange in the t -channel. We formulate the description of this process within the high-energy framework of eikonal dipole scattering. We obtain expressions for the light-cone wave function of the η c required in this framework as well as for the C -odd amplitudes due to exchange of a single photon, of a photon plus two gluons, and of three gluons. We relate these amplitudes to correlators of the plus component of the quark current in the light-cone wave function of the proton. For high transverse momenta, these correlators correspond to (leading twist) generalized parton distributions given by diagrams where all exchanged gauge bosons attach to a single quark in the proton. Diagrams involving multiquark matrix elements potentially sensitive to correlations screen infrared singularities. Moreover, they are numerically important for configurations where the exchanged bosons nearly share the total momentum transfer. Using two simple models for the three-quark Fock state of the proton at x ≃ 0.1 , we find that single photon exchange dominates for | t | < 1.5 GeV 2 . Here, the quark generalized parton distribution could be measured cleanly in γ ( * ) + p → η c + p via single photon exchange. For higher momentum transfer, three-gluon (“Odderon”) exchange is dominant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modification of Photoconductivity Spectra in ZnO–CdSe Quantum- Dot Composites upon Exposure to Additional Photoexcitation

The incorporation of CdS nanocrystals into a porous ZnO matrix results in sensitization of the composite in the visible spectral region. Studies of the photoconductivity spectra upon variable external illumination show that the spectra undergo reversible transformations. It is shown that the shape of the peak and the position of the local photoconductivity maximum corresponding to nanocrystals depend on the wavelength distribution of the incident radiation intensity. The mechanisms responsible for the process are discussed.

36 MATERIALS SCIENCE↗

New capabilities of the MORET 6 Monte Carlo neutron transport code

The MORET code is a simulation tool that solves the transport equation for neutrons using the Monte Carlo method. It allows users to model complex three-dimensional geometrical configurations in a user-friendly way. New features have been introduced to extend the application field of MORET beyond the usual criticality calculations for which it has been initially designed. The most important change is the addition of an analog fixed source mode which allows studies of systems of any reactivity combined with very flexible outputs. Other useful improvements have been added concerning the geometric part, the fission matrix, the multigroup sensitivity coefficients and the outputs. This paper presents an overview of these new features. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗