Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Validation of continuous energy sensitivity coefficients calculations in the MORET 5 code - 14269

A continuous-energy sensitivity coefficients calculation capability has been developed in the MORET 5 Monte Carlo code recently. As discussed in this paper, it relies on the differential operator method, an adjoint weighting model (to avoid calculating the fission source derivatives) and a constrained sensitivity coefficient model for sensitivity profiles to distributions such as, for instance, the fission spectrum. For now, the coefficients are provided per medium, per isotope, per reaction on an energy binning defined by the user. The sensitivity coefficients are currently available for the following quantities: total, elastic scattering, total inelastic scattering, fission, total capture and radiative capture cross sections, average neutron produced by fission and fission spectrum. This paper deals with the validation of this new feature in the MORET code on several benchmarks and applications with various energy spectra and geometrical configurations. This validation is performed through the UACSA expert group and the Jezebel ICSBEP benchmarks, but also thanks to calculations performed in the frame of experimental program design in the STACY facility. Comparisons are made using the MCNP6.1 code and the SCALE6.1 package as references. Preliminary results show a pretty good agreement between the different software. (authors)

42 ENGINEERING↗

WE-DE-207B-05: Measuring Spatial Resolution in Digital Breast Tomosynthesis: Update of AAPM Task Group 245

Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spread function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object-independent. Depth-direction spatial resolution may be measured directly using MTF or indirectly using ASF or SSP as surrogate measurements. While MTF is object-independent, it is invalid for nonlinear reconstructions.

60 APPLIED LIFE SCIENCES↗

K-Eigenvalue sensitivities of secondary distributions of continuous-energy data

MCNP6 has the capability to produce energy-resolved sensitivity profiles for secondary distributions (fission {Chi} and scattering laws). Computing both unconstrained and constrained profiles are possible. Verification is performed with analytic test problems and a comparison to TSUNAMI-3D, and the comparisons show MCNP6 calculates correct or consistent results. Continuous-energy calculations are performed for three fast critical experiments: Jezebel, Flattop, and copper-reflected Zeus. The sensitivities to the secondary distributions (integrated over chosen energy ranges) are of similar magnitude to those of many of the cross sections, demonstrating the possibility that integral experiments are useful for assessing the fidelity of these data as well. (authors)

97 MATHEMATICS AND COMPUTING↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Silicon photodiode with selective Zr/Si coating for extreme ultraviolet spectral range

The procedure of manufacturing silicon photodiodes with an integrated Zr/Si filter for extreme ultraviolet (EUV) spectral range is developed. A setup for measuring the sensitivity profile of detectors with spatial resolution better than 100 {mu}m is fabricated. The optical properties of silicon photodiodes in the EUV and visible spectral ranges are investigated. Some characteristics of SPD-100UV diodes with Zr/Si coating and without it, as well as of AXUV-100 diodes, are compared. In all types of detectors a narrow region beyond the operating aperture is found to be sensitive to the visible light. (photodetectors)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relationship between neutron yield rate of tokamak plasmas and spectrometer measured flux for different sight lines

A parametric relationship between total neutron yield rate and collimated fluxes related to the brightness (B) of plasma chords ({lambda}) is developed for different emissivity distributions of tokamak plasmas. Specifically, the brightness was expressed as a function of chord coordinates of radial position using a simple model for the emissivity profiles of width parameter w. The functional brightness dependence B({lambda},w) was calculated to examine the relationship between measured flux and deduced yield rate, and its plasma profile dependence. The results were used to determine the chord range of minimum profile sensitivity in order to identify the preferred collimator sight for the determination of yield rate from neutron emission spectroscopy (YNES) measurements. The YNES method is discussed in comparison to conventional methods to determine the total neutron yield rates and related plasma fusion power relying on uncollimated flux measurements and a different calibration base for the flux-yield relationship. The results have a special bearing for tokamaks operating with both deuterium and deuterium-tritium plasmas and future high power machines such as for ITER, DEMO, and IGNITOR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity studies to Support TEX critical experiments design

In the frame of the ongoing Thermal/Epithermal experiments program, supported by the DOE-NCSP, we are characterizing expected data with analysis of sensitivity coefficients to nuclear data. The computations were performed for detailed and simplified models of the experimental configurations in order to demonstrate their invariance with respect to small geometry variations. The sensitivity coefficients were computed with recently developed precise methodologies using Monte Carlo tools (MCNP-6.1, SCALE 6.1 and MORET 5.C.1) with the following nuclear data libraries: ENDF/B-VII.0, ENDF/B-VII.1, and JEFF3.1. Since the considered experiments are devoted to tantalum data validation, their neutronic characteristics are compared with the relevant integral experiment data collected in the OECD/NEA ICSBEP Handbook. Although analysis of sensitivity coefficients taken alone is insufficient for an entire assessment, we can conclude that TEX experimental results can fill gaps in the available benchmarks to facilitate quantification of uncertainty for plutonium containing systems with epithermal neutron spectra (e.g. wet plutonium-based powders). However, analysis of sensitivity profiles demonstrates that an advanced statistical methodology will be needed to fit tantalum nuclear data or to evaluate the associated uncertainties. (authors)

42 ENGINEERING↗

Temperature dependence of APD-based PET scanners

Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/°C , R = −0.96) temperature changes. Count rate evaluation showed that although the total count rate is consistently higher at 21 °C than at 24 °C for different source activity concentrations, this is mainly due to an increase in scattered and random coincidences. The peak total count rate is 400 kcps at both temperatures but is reached at lower activity at 21 °C. The peak true count rate is 138 kcps (at 100 MBq) at 21 °C and 180 kcps (at 125 MBq) at 24 °C. The peak noise equivalent count rate is also lower at 21 °C (70 kcps at 70 MBq) than at 24 °C (100 kcps at 100 MBq). At realistic activity levels, the scatter fraction is lower at higher temperatures, but at the cost of a strong decrease in true count rate.Conclusions: A model was proposed for the temperature dependence of APD-based PET scanners and evaluated using the LabPET small animal PET scanner. System sensitivity and count rate performance are strongly dependent on ambient temperature while system resolution is not. The authors’ results indicate that it is important to assure stable ambient temperature to obtain reproducible results in imaging studies with APD-based PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Data Testing Of Pu{sup 239} CIELO Evaluation With NDaST

Within the Collaborative International Evaluated Library Organisation (CIELO) project a coordinated effort is being made amongst the different nuclear data evaluation projects, ENDF, JEFF, JENDL etc. to improve the cross sections of six of the most important isotopes, Pu{sup 239}, U{sup 235}, U{sup 238}, Fe{sup 56}, O{sup 16} and H{sup 1}. Recently developed, the Nuclear Data and Sensitivity Tool (NDaST) is an online tool (http://www.oecd-nea.org/ndast/) that allows nuclear data evaluators to get rapid feedback about the consequences of changes to nuclear data on integral experiment benchmarks that exist within the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and International Reactor Physics Evaluation (IRPhE) Project handbooks. NDaST links the thousands of nuclear data sensitivity profiles in the Database for ICSBEP (DICE) and the IRPhE Database and Analysis Tool (IDAT), with the nuclear data viewing tool JANIS. NDaST can be used to provide timely feedback to CIELO participants. Normally an evaluator changes the ENDF/B files based on differential data, and subsequently hands the new evaluation to testers who give feedback on the performance of the new evaluation in terms of accurately predicting the integral benchmark results. This process is often slow. With accurate sensitivity coefficients it is feasible to predict the results of changes to differential data without performing the direct substitution, by simply multiplying the change in cross section with the sensitivity. Furthermore, when multiple aspects of the file are changed simultaneously, the impact of each individual change can be muddled in the substitution testing. NDaST when used in conjunction with direct perturbation testing can help provide feedback as to which cross section changes are driving changes in the benchmarks. In this paper we focus on Pu{sup 239}, and comparing the NDaST predictions of CIELO files to direct substitution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Minimum critical masses and their uncertainties for several fissile nuclides and reflectors - 14296

A systematic effort was undertaken to reevaluate the minimum critical mass for several fissile nuclides and reflectors. This was done using MCNP6 in combination with several modern nuclear data libraries, viz. ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1. This combination was benchmarked extensively against criticality safety benchmarks. The procedure to extract the minimum critical mass from the MCNP6 calculations was carefully implemented, so that it would have a negligible impact on the accuracy of the end results. All parts of the calculation, i.e. nuclear data processing, MCNP6 models, and post-processing, were applied consistently for all cases, involving varying fissile nuclides and reflectors. Results for the minimum critical mass were generated for {sup 233,235}U, {sup 236,239,241}Pu, {sup 242m}Am, {sup 243,245,247}Cm, and {sup 249,251}Cf, for the case of water moderation and water reflection. For {sup 235}U, the minimum critical mass was also calculated for cases with other reflectors, such as beryllium, heavy water, graphite, lead, and concrete. The results for the water reflection cases are in good agreement with most of the literature values, but for the cases with reflectors such as graphite, lead, or concrete, there are sizable differences. The accuracy of the results was assessed in two ways. First, a comparison was made with criticality safety benchmark results, by selecting benchmarks that resemble the minimum mass systems the most. It was clear that for {sup 233,235}U and {sup 239}Pu with water reflection, the differences in minimum critical masses between the libraries are consistent with the differences obtained for benchmark cases. The difference between the benchmark calculations and the benchmark values is then an indication of the accuracy with which one can simulate comparable systems. Secondly, sensitivity runs were performed with the new MCNP6 sensitivity option, based on ENDF/B-VII.1 nuclear data. For each fissile nuclide, the sensitivity of k{sub eff} to cross sections such as capture, fission, elastic, inelastic was calculated for the minimum critical mass case. The same was done for the {sup 1}H and {sup 16}O cross sections in the moderator and reflector. The uncertainty in k{sub eff} was calculated by combining the sensitivity profiles with the appropriate ENDF/B-VII.1 covariance matrix, using the SUSD code. As a final step, the uncertainty in k{sub eff} can be translated to an uncertainty in the minimum critical mass. (author)

42 ENGINEERING↗

User Manual for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015- 2016, Whisper was updated to version 1.1 and is to be included with the upcoming release of MCNP6.2. This document describes the user input and options for running whisper-1.1, including 2 perl utility scripts that simplify ordinary NCS work, whisper_mcnp.pl and whisper_usl.pl. For many detailed references on the theory, applications, nuclear data & covariances, SQA, verification-validation, adjointbased methods for sensitivity-uncertainty analysis, and more – see the Whisper – NCS Validation section of the MCNP Reference Collection at mcnp.lanl.gov. There are currently over 50 Whisper reference documents available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methodology, verification, and performance of the continuous-energy nuclear data sensitivity capability in MCNP6

A continuous-energy sensitivity coefficient capability has been introduced into MCNP6. The methods for generating energy-resolved and energy-integrated sensitivity profiles are discussed. Results from the verification exercises that were performed are given, and these show that MCNP6 compares favorably with analytic solutions, direct density perturbations, and comparisons to TSUNAMI-3D and MONK. Run-time and memory requirements are assessed for typical applications, and these are shown to be reasonable with modern computing resources. (authors)

97 MATHEMATICS AND COMPUTING↗

Release Notes for Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation [1-3]. It uses the sensitivity profile data for an application as computed by MCNP6 [4-6] along with covariance files [7,8] for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014 [3]. During 2015-2016, Whisper was updated to version 1.1 [9] and is to be included with the upcoming release of MCNP6.2. This document describes the Whisper-1.1 package that will be included with the MCNP6.2 release during 2017. Specific details are provided on the computer systems supported, the software quality assurance (SQA) procedures, installation, and testing. This document does not address other important topics, such as the importance of sensitivity-uncertainty (SU) methods to NCS validation, the theory underlying SU methodology, tutorials on the usage of MCNP-Whisper, practical approaches to using SU methodology to support and extend traditional validation, etc. There are over 50 documents included with Whisper-1.1 and available in the MCNP Reference Collection on the MCNP website (mcnp.lanl.gov) that address all of those topics and more. In this document, however, a complete bibliography of relevant MCNP-Whisper references is provided.

97 MATHEMATICS AND COMPUTING↗

Preliminary neutronic study of D{sub 2}O-Cooled high conversion PWRs

This paper presents a preliminary neutronics analysis of tight-pitch D{sub 2}O-cooled high-conversion pressurised water reactors (HPWR) loaded with MOX fuel aiming at high Pu conversion and negative void coefficient. SCALE6.1 code has been exclusively utilized for this study. The analyses are performed in two separate parts. The first part of this paper investigates the performance of axial and internal blankets and seeks break-even or near-breeder core even without the presence of radial blankets. The analyses showed that the relative Pu mass balance was effectively increased by the addition of the axial blanket. The addition of only 4 cm of blanket resulted in the 4000 pcm increase in the void coefficient. Thus, the presence of the axial blanket made the void coefficient hardly negative. The second part of this paper performs sensitivity and uncertainty analyses of integral parameters (k{sub eff} and void coefficient) for selected systems in order to analyze the characters of this high-conversion PWR from different aspects. The uncertainty analysis of k{sub eff} showed that its breakup contributions for D{sub 2}O-HPWR were very similar to other fast systems (SFR and H{sub 2}O-HPWR) such that the key contributors were {sup 238}U inelastic and {sup 239}Pu ν-bar. However, breakup uncertainties of void coefficients showed that while those of D{sub 2}O-HPWR resembled to H{sub 2}O-HPWR, Na elastic became the significant contributor of the void coefficient uncertainty of SFR. Also sensitivity profiles of {sup 238}U inelastic and {sup 239}Pu ν-bar to the void coefficient revealed that those of SFR were quite dissimilar to both HPWRs. The study also found that while the absolute values of void coefficient uncertainty for D{sub 2}O-HPWR were invariant through the burnup, its percentage uncertainty was significantly increased.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Covariance Data File Formats for Whisper-1.0 & Whisper-1.1

Whisper is a statistical analysis package developed in 2014 to support nuclear criticality safety (NCS) validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit (USL) for the application. Whisper version 1.0 was first developed and used at LANL in 2014. During 2015-2016, Whisper was updated to version 1.1 and is to be included with the upcoming release of MCNP6.2. This report describes the file formats used for the covariance data in both Whisper-1.0 and Whisper-1.1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Structure-guided inhibitor design for human FAAH by interspecies active site conversion

The integral membrane enzyme fatty acid amide hydrolase (FAAH) hydrolyzes the endocannabinoid anandamide and related amidated signaling lipids. Genetic or pharmacological inactivation of FAAH produces analgesic, anxiolytic, and antiinflammatory phenotypes but not the undesirable side effects of direct cannabinoid receptor agonists, indicating that FAAH may be a promising therapeutic target. Structure-based inhibitor design has, however, been hampered by difficulties in expressing the human FAAH enzyme. Here, we address this problem by interconverting the active sites of rat and human FAAH using site-directed mutagenesis. The resulting humanized rat (h/r) FAAH protein exhibits the inhibitor sensitivity profiles of human FAAH but maintains the high-expression yield of the rat enzyme. We report a 2.75-{angstrom} crystal structure of h/rFAAH complexed with an inhibitor, N-phenyl-4-(quinolin-3-ylmethyl)piperidine-1-carboxamide (PF-750), that shows strong preference for human FAAH. This structure offers compelling insights to explain the species selectivity of FAAH inhibitors, which should guide future drug design programs.

36 MATERIALS SCIENCE↗

TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.

60 APPLIED LIFE SCIENCES↗