Search NASA⌕ Search

SEARCH · Search NASA

Results for “Septum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dynamic Transcriptomic and Phosphoproteomic Analysis During Cell Wall Stress in Aspergillus nidulans

The fungal cell-wall integrity signaling (CWIS) pathway regulates cellular response to environmental stress to enable wall repair and resumption of normal growth. This complex, interconnected, pathway has been only partially characterized in filamentous fungi. To better understand the dynamic cellular response to wall perturbation, a β-glucan synthase inhibitor (micafungin) was added to a growing A. nidulans shake-flask culture. From this flask, transcriptomic and phosphoproteomic data were acquired over 10 and 120 min, respectively. To differentiate statistically-significant dynamic behavior from noise, a multivariate adaptive regression splines (MARS) model was applied to both data sets. Over 1800 genes were dynamically expressed and over 700 phosphorylation sites had changing phosphorylation levels upon micafungin exposure. Twelve kinases had altered phosphorylation and phenotypic profiling of all non-essential kinase deletion mutants revealed putative connections between PrkA, Hk-8–4, and Stk19 and the CWIS pathway. Our collective data implicate actin regulation, endocytosis, and septum formation as critical cellular processes responding to activation of the CWIS pathway, and connections between CWIS and calcium, HOG, and SIN signaling pathways.

59 BASIC BIOLOGICAL SCIENCES↗

The role of CenKR in the coordination of Rhodobacter sphaeroides cell elongation and division

ABSTRACT Cell elongation and division are essential aspects of the bacterial life cycle that must be coordinated for viability and replication. The impact of misregulation of these processes is not well understood as these systems are often not amenable to traditional genetic manipulation. Recently, we reported on the CenKR two-component system (TCS) in the Gram-negative bacterium Rhodobacter sphaeroides that is genetically tractable, widely conserved in α-proteobacteria, and directly regulates the expression of components crucial for cell elongation and division, including genes encoding subunit of the Tol-Pal complex. In this work, we show that overexpression of cenK results in cell filamentation and chaining. Using cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET), we generated high-resolution two-dimensional (2D) images and three-dimensional (3D) volumes of the cell envelope and division septum of wild-type cells and a cenK overexpression strain finding that these morphological changes stem from defects in outer membrane (OM) and peptidoglycan (PG) constriction. By monitoring the localization of Pal, PG biosynthesis, and the bacterial cytoskeletal proteins MreB and FtsZ, we developed a model for how increased CenKR activity leads to changes in cell elongation and division. This model predicts that increased CenKR activity decreases the mobility of Pal, delaying OM constriction, and ultimately disrupting the midcell positioning of MreB and FtsZ and interfering with the spatial regulation of PG synthesis and remodeling. IMPORTANCE By coordinating cell elongation and division, bacteria maintain their shape, support critical envelope functions, and orchestrate division. Regulatory and assembly systems have been implicated in these processes in some well-studied Gram-negative bacteria. However, we lack information on these processes and their conservation across the bacterial phylogeny. In R. sphaeroides and other α-proteobacteria, CenKR is an essential two-component system (TCS) that regulates the expression of genes known or predicted to function in cell envelope biosynthesis, elongation, and/or division. Here, we leverage unique features of CenKR to understand how increasing its activity impacts cell elongation/division and use antibiotics to identify how modulating the activity of this TCS leads to changes in cell morphology. Our results provide new insight into how CenKR activity controls the structure and function of the bacterial envelope, the localization of cell elongation and division machinery, and cellular processes in organisms with importance in health, host-microbe interactions, and biotechnology.

59 BASIC BIOLOGICAL SCIENCES↗

Water isotope data for the TEMPEST study site, 2023-2026

This dataset contains water isotope (deuterium (dD) and oxygen (d18O)) data from porewater, experimental source water, and aquifer sources from the Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental field site in Edgewater, MD. Samples were taken from 2023-2026 and included in file "TEMPEST_Water_Isotope_LANL_2023-2026.csv". Porewater samples were taken from 15cm depth at multiple locations in each experimental plot (i.e., control, freshwater, and saltwater). Water samples were stored in 2 ml amber glass vials with septum caps under refrigeration until analysis. A L2140-i Picarro cavity ringdown spectrometer connected to an A0211 Picarro vaporization module was used to run water samples. Standards (United States Geological Survey (USGS) 47 and 48) were used to check instrument accuracy during each run of samples. Post-processing codes were run to calculate isotopic values from raw data. Reported isotope data is post-processed. Raw data CSV files from the Picarro were processed using a Python script and output as excel files containing data calibrated to Vienna Standard Mean Ocean Water (VSMOW). Standardization is based on USGS47 and USGS48 standards that are measured before and after every 5-10 unknowns. Every measurement is comprised of 10 injections. Processing involved discarding the first 4 injections due to a known memory effect. Raw means of the last 6 injections are taken for each measurement and then corrected from the linear calibration relationship of the USGS standards expected vs measured values to obtain corrected compositions relative to VSMOW. Reported isotope data are corrected mean results.

Aquifer↗

Current status of the electron transport line from RCS to ESR: RTE line

The electron injection system of the U.S. Electron-Ion Collider (EIC) is located outside of the RHIC tunnel. Electrons beams accelerated by the Rapid Cycling Synchrotron (RCS) must be transported to the Electron Storage Ring (ESR), which resides within the RHIC tunnel. To accomplish this, a dedicated beam transport line, referred to as RTE (RCS-to-ESR) line is being designed. The proposed conceptual design comprises three main sections; RCS extraction, a vertical bend and dispersion suppression region, and ESR injection matching. The extraction section uses pulsed kickers and septum magnets to achieve a total deflection angle of 3 degrees. To align the injection section with ESR, the beamline must provide a vertical elevation of 1.68 m, and an array of FODO cells is used to suppress the vertical dispersion. The total length of the RTE line is approximately 133 m, and this paper presents the current design status and considerations for this transport line.

Accelerator Physics↗

New Collins Quad Design

The Collins quadrupoles are used on the DARHT 2nd axis to transform the elliptical beam from the septum quadrupole back to a round beam. They are also used to minimize kicker smear by producing a point-to-point focus from the kicker to the target. The present Collins quads introduce significant aberrations due to the design of the iron pole tip. The effect of these aberrations becomes particularly large as the beam size in the Collins quads increases. This note describes an improved 2D pole tip design for the Collins quads developed using POISSON.

43 PARTICLE ACCELERATORS↗

Feasibility of using crystal channeling for the beam loss mitigation in Slow Extraction at 8GeV

The mitigation of the beam losses in slow extraction is becoming more and more demanding in accelerator applications for HEP as the beam power is gradually increasing. The successful demonstration of using the proton beam channeling at 450GeV to deflect the beam away from the extraction septa opens the new levels of improving the slow extraction efficiency. It is yet to be demonstrated that this method is still effective at low and medium proton beam energies. Here we present the promising results of the recent computer simulation studies of the septum shadowing at 8GeV for the Mu2e project slow extraction at Fermilab. Depending on the beam parameters the beam loss reduction is shown to be achievable in the range of 1/3 to factor of 3.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Scattering Through Foil at NSRL

In this note, we describe the foil structure that is used in the NASA Space Radiation Laboratory (NSRL) transport line just before D6 septum magnet. Foils of different materials and thickness are used through which different ion species at different energies pass. Foil removes the electrons from the incoming ions and make it fully stripped (or partially stripped is also possible). Further, when charged particles pass through a foil, the outgoing particles form a Gaussian like angular distribution. This Gaussian like distribution passes through a set of octupole magnets creates a uniform beam distribution at the NSRL target which is required for various beam experiments. We utilize the Bmad and SRIM packages to calculate the energy loss through the foils for various ion species at different energies and charge states. Finally, we provide a summary of the energy loss calculations through the foils using these two different methods.

43 PARTICLE ACCELERATORS↗

Multiphysics simulations of a steady-state lower hybrid current drive antenna for the FSNF

The Fusion Nuclear Science Facility (FNSF) is a proposed tokamak reactor with the mission to investigate operation of a fusion reactor in a nuclear environment. The high neutron fluence component of the FNSF mission requires steady-state operation for extremely long pulses (t_{pulse} ∼ months) at full power. Plasma sustainment and current drive will be critical components of a successful FNSF. COMSOL Multiphysics software is used for combined radiofrequency (RF) and thermal simulations of the lower hybrid current drive (LHCD) antenna system. These simu- lations consider the resistive RF losses in the antenna including realistic surface roughness and a range of potential materials. The thermal analysis adds volumetric nuclear heating, plasma heat flux on leading edges, and electromagnetic radiation from the plasma to the RF heating calculated by COMSOL. Additional neutronics calculations have been performed to determine the impact of these antenna designs on activated waste disposal for the materials considered. The simulations show that it is technically feasible to implement a fully-active multi-junction (FAM) rather than a passive-active multi-junction (PAM) style of antenna if the septum between adjacent waveguides is sufficiently wide and the thermal conductivity of the structural material is sufficiently high. The FAM has the benefit of higher achievable power density with respect to the PAM, which results in a more compact antenna with potentially lower impact on neutron shielding and tritium breeding. These considerations point to tungsten rather than steel as the preferred structural material in constructing the antenna.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-sealing closure enables access to several fluid containers

Self-sealing closure enables small amounts of specific biochemical solutions to be withdrawn from or added to containers in inaccessible or small spaces. It uses a self-sealing septum of a silicone elastomer through which a hypodermic needle can be inserted.

Wheeler, S. B.↗

Pattern of filling in the pulmonary capillary bed.

Artificially ventilated and perfused dog lungs were rapidly frozen under various physiological conditions. In 2-micron-thick sections the number of red blood cells (RBCs) per 10-micron length of alveolar septum was counted. Under conditions in which alveolar pressure exceeded venous pressure, variation in RBC concentration within areas supplied by single arterioles accounted completely for variation between areas supplied by different arterioles. Except at very high perfusion pressures when venous pressure exceeded alveolar pressure, there was no significant correlation between RBC concentrations of pairs of adjacent septa.

Warrell, D. A.↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Space shuttle galley water system test program

A water system for food rehydration was tested to determine the requirements for a space shuttle gallery flight system. A new food package concept had been previously developed in which water was introduced into the sealed package by means of a needle and septum. The needle configuration was developed and the flow characteristics measured. The interface between the food package and the water system, oven, and food tray was determined.

Source record↗

Suprachiasmatic nuclei and Circadian rhythms. The role of suprachiasmatic nuclei on rhythmic activity of neurons in the lateral hypothalamic area, ventromedian nuclei and pineal gland

Unit activity of lateral hypothalamic area (LHA) and Ventromedian nuclei (VMN) was recorded in urethane anesthetized male rats. A 5 to 10 sec. a 3-5 min and a circadian rhythmicity were observed. In about 15% of all neurons, spontaneous activity of LHA and VMN showed reciprocal relationships. Subthreshold stimuli applied at a slow rate in the septum and the suprachiasmatic nuclei (SCN) suppressed the rhythms without changing firing rates. On the other hand, stimulation of the optic nerve at a rate of 5 to 10/sec increased firing rates in 1/3 of neurons of SCN. Iontophoretically applied acetylcholine increased 80% of tested neurons of SCN, whereas norepinephrine, dopamine and 5 HT inhibited 64, 60 and 75% of SCN neurons respectively. These inhibitions were much stronger in neurons, the activity of which was increased by optic nerve stimulation. Stimulation of the SCN inhibited the tonic activity in cervical sympathetic nerves.

Nishino, H.↗

Food packages for Space Shuttle

The paper reviews food packaging techniques used in space flight missions and describes the system developed for the Space Shuttle. Attention is directed to bite-size food cubes used in Gemini, Gemini rehydratable food packages, Apollo spoon-bowl rehydratable packages, thermostabilized flex pouch for Apollo, tear-top commercial food cans used in Skylab, polyethylene beverage containers, Skylab rehydratable food package, Space Shuttle food package configuration, duck-bill septum rehydration device, and a drinking/dispensing nozzle for Space Shuttle liquids. Constraints and testing of packaging is considered, a comparison of food package materials is presented, and typical Shuttle foods and beverages are listed.

Fohey, M. F.↗

Design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

A titanium multiwall thermal protection system panel was designed. The panel is a nine sheet sandwich structure consisting of an upper and lower face sheet; four dimpled sheets, three septum sheets, and clips for attachment to a vehicle structure. An acceptable fabrication process was developed, and the panel design was verified through mechanical and thermal testing of component specimens. A design was completed which takes into consideration fabrication techniques, thermal properties, mechanical properties, and materials availability.

Blair, W.↗

Laboratory study of efficient add-on treatments for interior noise control in light aircraft

Experimental and theoretical studies of the transmission loss (TL) of 1.15 x 1.46 m flat stiffened-skin aluminum panels are described. Panel configurations included panels with no treatment and eight combinations of treatments consisting of a fiberglass-septum layer, a foam-foil damping material, and a plywood double wall trim panel. Measured TL of the untreated panel and the panel with a damping layer showed characteristics of the double mass law: at low frequencies the TL followed a mass law trend associated with the average mass of both skin and stiffness, while at higher frequencies the TL followed a mass law trend associated with skin mass only. A comparison of TL for panels treated with a damping layer, a fiberglass layer, or a trim panel showed that the effects of damping are frequency dependent with some performing better below 500 Hz and others performing better above 500 Hz. Treatment combinations showed that two treatments with the same mass could have TL values different by about 10 dB, while other combinations having weights different by a factor of two could have TL values within a few dB over most of the frequency range. The highest TL values (50 dB at 1000 Hz) were obtained with a treatment consisting of a fiberglass layer, a trim panel, and damping layers on both the stiffened panel and the trim panel.

Mixson, J. S.↗

Cabin Noise Control for Twin Engine General Aviation Aircraft

An analytical model based on modal analysis was developed to predict the noise transmission into a twin-engine light aircraft. The model was applied to optimize the interior noise to an A-weighted level of 85 dBA. To achieve the required noise attenuation, add-on treatments in the form of honeycomb panels, damping tapes, acoustic blankets, septum barriers and limp trim panels were added to the existing structure. The added weight of the noise control treatment is about 1.1 percent of the total gross take-off weight of the aircraft.

Vaicaitis, R.↗