Search NASA⌕ Search

SEARCH · Search NASA

Results for “Session detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TH-B-BRC-02: Troubleshooting Issues with Linear Accelerator

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-03: Measurement and Calibration Discrepancy: Advanced Warning Guidance

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

Introduction

The 2014 SPIE Sensing Technologies for Global Health, Military Medicine and Environmental Monitoring conference embraced a wealth of state-of-the-art information in basic and applied science. This event covered the latest developments in the following areas: Non-invasive Disease Diagnostics for Global Health- This opening series of two consecutive sessions focused on oral biospecimen based rapid assays and point-of-care devices for the detection of pathogens causing infectious diseases, biomarkers for cancer, and analytes for noncommunicable diseases such as diabetes. They also covered presentations on the human proteasome and microbiome with linkage to human diseases and diagnostic approaches. The sessions were built on the past experience and expertise of the National Institutes of Health, National Institutes of Dental and Craniofacial Research. Military Medicine I: Traumatic Brain Injury and PTSD-This assembly covered oral-biomarker based diagnostics for brain damage and TBI as well as prevention and rehabilitation technologies. Neurorehabilitation and noninvasive neuromodulation were also discussed as critical approaches for effective functioning. Military Medicine II: Physiology and Medicine of Extreme Environments and Spaceflight-This scientific segment showcased physiological, pharmacological and diagnostic sensing methodologies during spaceflight per the National Aeronautics and Space Administration as well as military-relevant toxicans and future sensing trends per the Department of Defense. It also included latest technologies to determine hydration status in warfighters, eye surgery using the latest laser technologies, and sensing tools for blood analysis.  Sensing Technologies for Disease Diagnostics and Environmental Monitoring-This closing series of two consecutive sessions provided the venues to learn and discuss more results on the next generation of diagnostic tools and field technologies for diseases, including biomarker detection by digital imaging, multiplex technologies, capillary electrophoresis and molecular platforms serving as labs-on-chips. This conference allowed cross-fertilization of ideas, projects and collaborative work by a multidisciplinary audience of national and international colleagues from the academia, industry and federal government: The National Institutes of Health, National Aeronautics and Space Administration, and the Department of Defense.

Wotring, Virginia E.↗

Outcomes of Iodine-125 Plaque Brachytherapy for Uveal Melanoma With Intraoperative Ultrasonography and Supplemental Transpupillary Thermotherapy

Purpose: To assess the impact on local tumor control of intraoperative ultrasonographic plaque visualization and selective application of transpupillary thermotherapy (TTT) in the treatment of posterior uveal melanoma with iodine-125 (I-125) episcleral plaque brachytherapy (EPB). Methods and Materials: Retrospective analysis of 526 patients treated with I-125 EPB for posterior uveal melanoma. Clinical features, dosimetric parameters, TTT treatments, and local tumor control outcomes were recorded. Statistical analysis was performed using Cox proportional hazards and Kaplan-Meier life table method. Results: The study included 270 men (51%) and 256 women (49%), with a median age of 63 years (mean, 62 years; range, 16-91 years). Median dose to the tumor apex was 94.4 Gy (mean, 97.8; range, 43.9-183.9) and to the tumor base was 257.9 Gy (mean, 275.6; range, 124.2-729.8). Plaque tilt >1 mm away from the sclera at plaque removal was detected in 142 cases (27%). Supplemental TTT was performed in 72 patients (13.7%). One or 2 TTT sessions were required in 71 TTT cases (98.6%). After a median follow-up of 45.9 months (mean, 53.4 months; range, 6-175 months), local tumor recurrence was detected in 19 patients (3.6%). Local tumor recurrence was associated with lower dose to the tumor base (P=.02). Conclusions: Ultrasound-guided plaque localization of I-125 EPB is associated with excellent local tumor control. Detection of plaque tilt by ultrasonography at plaque removal allows supplemental TTT to be used in patients at potentially higher risk for local recurrence while sparing the majority of patients who are at low risk. Most patients require only 1 or 2 TTT sessions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JANNAF 28th Propellant Development and Characterization Subcommittee and 17th Safety and Environmental Protection Subcommittee Joint Meeting

This volume contains 37 unclassified/unlimited-distribution technical papers that were presented at the JANNAF 28th Propellant Development & Characterization Subcommittee (PDCS) and 17th Safety & Environmental Protection Subcommittee (S&EPS) Joint Meeting, held 26-30 April 1999 at the Town & Country Hotel and the Naval Submarine Base, San Diego, California. Volume II contains 29 unclassified/limited-distribution papers that were presented at the 28th PDCS and 17th S&EPS Joint Meeting. Volume III contains a classified paper that was presented at the 28th PDCS Meeting on 27 April 1999. Topics covered in PDCS sessions include: solid propellant rheology; solid propellant surveillance and aging; propellant process engineering; new solid propellant ingredients and formulation development; reduced toxicity liquid propellants; characterization of hypergolic propellants; and solid propellant chemical analysis methods. Topics covered in S&EPS sessions include: space launch range safety; liquid propellant hazards; vapor detection methods for toxic propellant vapors and other hazardous gases; toxicity of propellants, ingredients, and propellant combustion products; personal protective equipment for toxic liquid propellants; and demilitarization/treatment of energetic material wastes.

Cocchiaro, James E.↗

Lunar and Planetary Science XXXV: Venus

The session "Venus" included the following reports:Is It Possible to Detect Magnetic Materials on Venus with Bistatic Radar Probing?; Airfall Crater Deposits on the Surface of Venus: Do We See Them in the Venera Panoramas?; Rift System Architecture on Venus; Constraints on Deformation Belt Evolution on Venus; An Admittance Survey of Large Volcanoes on Venus: Implications for Volcano Growth; Crustal Thickening Above a Convecting Mantle with Application to Venus and Mars; Geological Mapping of Venus: Interpretation of Geologic History and Assessment of; Directional and Non-Directional Models; Ages of Venusian Ridge Belts Relative to Regional Plains; and Plumes as a Mechanism for Equilibrium Resurfacing of Venus.

Source record↗

Integrated Weed Control for Land Stewardship at Legacy Management's Rocky Flats Site in Colorado - 13086

Land stewardship is one of nine sustainability programs in the U.S. Department of Energy's Environmental Management System. Land stewardship includes maintaining and improving ecosystem health. At the Rocky Flats Site near Westminster, Colorado, land stewardship is an integral component of the Office of Legacy Management's post-closure monitoring and management at the site. Nearly 263 hectares (650 acres) were disturbed and re-vegetated during site cleanup and closure operations. Proactive management of revegetation areas is critical to the successful reestablishment of native grasslands, wetlands, and riparian communities. The undisturbed native plant communities that occur at the site also require active management to maintain the high-quality wetlands and other habitats that are home to numerous species of birds and other wildlife such as elk and deer, rare plant communities, and the federally listed threatened Preble's meadow jumping mouse. Over the past several decades, an increase of Noxious weeds has impacted much of Colorado's Front Range. As a result, weed control is a key component of the land stewardship program at Rocky Flats. Thirty-three species of state-listed Noxious weeds are known to occur in the Central and Peripheral Operable Units at Rocky Flats, along with another five species that are considered invasive at the site. Early detection and rapid response to control new invasive species is crucial to the program. An integrated weed control/vegetation management approach is key to maintaining healthy, sustainable plant communities that are able to resist Noxious weed invasions. Weed mapping, field surveys, and field-staff training sessions (to learn how to identify new potential problem species) are conducted to help detect and prevent new weed problems. The integrated approach at Rocky Flats includes administrative and cultural techniques (prevention), mechanical controls, biological controls, and chemical controls. Several species of biocontrol insects have been released to assist with control of different target weed species. Monitoring is conducted to evaluate the effectiveness of control efforts and to provide information for future control efforts. The effective implementation of this integrated approach has reduced the infestation levels of many species and has kept several newly discovered invasive species from spreading and becoming larger problems at the site. (authors)

54 ENVIRONMENTAL SCIENCES↗

INTERFEROMETRIC MONITORING OF GAMMA-RAY BRIGHT AGNs. I. THE RESULTS OF SINGLE-EPOCH MULTIFREQUENCY OBSERVATIONS

We present results of single-epoch very long baseline interferometry (VLBI) observations of gamma-ray bright active galactic nuclei (AGNs) using the Korean VLBI Network (KVN) at the 22, 43, 86, and 129 GHz bands, which are part of a KVN key science program, Interferometric Monitoring of Gamma-Ray Bright AGNs. We selected a total of 34 radio-loud AGNs of which 30 sources are gamma-ray bright AGNs with flux densities of >6 × 10{sup −10} ph cm{sup −2} s{sup −1}. Single-epoch multifrequency VLBI observations of the target sources were conducted during a 24 hr session on 2013 November 19 and 20. All observed sources were detected and imaged at all frequency bands, with or without a frequency phase transfer technique, which enabled the imaging of 12 faint sources at 129 GHz, except for one source. Many of the target sources are resolved on milliarcsecond scales, yielding a core-jet structure, with the VLBI core dominating the synchrotron emission on a milliarcsecond scale. CLEAN flux densities of the target sources are 0.43–28 Jy, 0.32–21 Jy, 0.18–11 Jy, and 0.35–8.0 Jy in the 22, 43, 86, and 129 GHz bands, respectively. Spectra of the target sources become steeper at higher frequency, with spectral index means of −0.40, −0.62, and −1.00 in the 22–43 GHz, 43–86 GHz and 86–129 GHz bands, respectively, implying that the target sources become optically thin at higher frequencies (e.g., 86–129 GHz).

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of emetic activity in the cat by monitoring venous pressure and audio signals

To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

A Nagahara↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Ka-band (8.4/32 GHz) has been constructed using fifty-one 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec in a cos delta and 290 micro-arcsec in delta. There is evidence for zonal errors at the 100 micro-arcsec level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

reference systems catalog↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Kaband (8.4/32 GHz) has been constructed using fiftyone 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec ( mu as) in alpha cos delta and 290 mu as in delta. There is evidence for zonal errors at the 100 mu as level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

interferometry↗

Sparse Superpixel Unmixing for Hyperspectral Image Analysis

Software was developed that automatically detects minerals that are present in each pixel of a hyperspectral image. An algorithm based on sparse spectral unmixing with Bayesian Positive Source Separation is used to produce mineral abundance maps from hyperspectral images. A superpixel segmentation strategy enables efficient unmixing in an interactive session. The algorithm computes statistically likely combinations of constituents based on a set of possible constituent minerals whose abundances are uncertain. A library of source spectra from laboratory experiments or previous remote observations is used. A superpixel segmentation strategy improves analysis time by orders of magnitude, permitting incorporation into an interactive user session (see figure). Mineralogical search strategies can be categorized as supervised or unsupervised. Supervised methods use a detection function, developed on previous data by hand or statistical techniques, to identify one or more specific target signals. Purely unsupervised results are not always physically meaningful, and may ignore subtle or localized mineralogy since they aim to minimize reconstruction error over the entire image. This algorithm offers advantages of both methods, providing meaningful physical interpretations and sensitivity to subtle or unexpected minerals.

Castano, Rebecca↗

Cutting-Edge Operations Concepts: Intelligent Infrastructure, Cooperative Driving, Signal Control, and Curbside Management

The objective of this breakout session at the NREL Mobility workshop was to examine emerging traffic operations concepts built on key detection technology such as radars, lidars, and imaging recognition - and identify challenges and paths forward to integrate into our current roadway system. The key objective were to identify the opportunities for intelligent infrastructure to support near-term safety, equity, energy, and congestion mitigation goals, while supporting longer term connected-automated vehicle objectives. In the plenary session, Eric Raamot, from the USDOT Highly Automated Safety Systems Office challenged the participants to think broadly about the roll of standards and reference architecture to provide both an accelerated rollout of intelligent infrastructure, but also a repeatable and supportable framework upon which many infrastructure owners and operators (IOOs) could utilize for their implementation purposes.

ADVANCED PROPULSION SYSTEMS↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

IP Profiling via Service Cluster Membership Vectors

This study investigates the feasibility of establishing and maintaining a system of compact IP behavioral profiles as a robust means of computer anomaly definition and detection. These profiles are based upon the degree to which a system's (IP's) network traffic is distributed among stable characteristic clusters derived of the aggregate session traffic generated by each of the major network services. In short, an IP's profile represents its degree of membership in these derived service clusters. The goal is to quantify and rank behaviors that are outside of the statistical norm for the services in question, or present significant deviation from profile for individual client IPs. Herein, we establish stable clusters for accessible features of common session traffic, migrate these clusters over time, define IP behavior profiles with respect to these clusters, migrate individual IP profiles over time, and demonstrate the detection of IP behavioral changes in terms of deviation from profile.

99 GENERAL AND MISCELLANEOUS↗

Quasi real time in vivo dosimetry for VMAT

Purpose: Results about the feasibility of a method for quasi real timein vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images was adopted to verify off-axis reproducibility of fractionated plan delivery. Methods: An algorithm to reconstructin vivo the isocenter dose, D{sub iso}, for RapidArc treatments has been developed. 20 VMAT plans, optimized with two opposite arcs, for prostate, pancreas, and head treatments have been delivered by a Varian linac both to a conic PMMA phantom with elliptical section and to patients. The ratios R between reconstructed D{sub iso} and the planned doses were determined for phantom and patient irradiations adopting an acceptance criterion of ±5%. In total, 40 phantom checks and 400 patient checks were analyzed. Moreover, 3% and 3 mm criteria were adopted for portal image γ-analysis to assess patient irradiation reproducibility. Results: The average ratio R, between reconstructed and planned doses for the PMMA phantom irradiations was equal to 1.007 ± 0.024. When the IVD method was applied to the 20 patients, the average R ratio was equal to 1.003 ± 0.017 and 96% of the tests were within the acceptance criteria. The portal image γ-analysis supplied 88% of the tests within the pass rates γ{sub mean} ≤ 0.4 and P{sub γ<1} ≥ 98%. All the warnings were understood comparing the CT and the cone beam CT images and in one case a patient's setup error was detected and corrected for the successive fractions. Conclusions: This preliminary experience suggests that the method is able to detect dosimetric errors in quasi real time at the end of the therapy session. The authors intend to extend this procedure to other pathologies with the integration of in-room imaging verification by cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interferometric Monitoring of Gamma-Ray Bright AGNs: S5 0716+714

We present the results of very long baseline interferometry (VLBI) observations of gamma-ray bright blazar S5 0716+714 using the Korean VLBI Network (KVN) at the 22, 43, 86, and 129 GHz bands, as part of the Interferometric Monitoring of Gamma-ray Bright active galactic nuclei (iMOGABA) KVN key science program. Observations were conducted in 29 sessions from 2013 January 16 to 2016 March 1, with the source being detected and imaged at all available frequencies. In all epochs, the source was compact on the milliarcsecond scale, yielding a compact VLBI core dominating the synchrotron emission on these scales. Based on the multiwavelength data between 15 GHz (Owens Valley Radio Observatory) and 230 GHz (Submillimeter Array), we found that the source shows multiple prominent enhancements of the flux density at the centimeter (cm) and millimeter (mm) wavelengths, with mm enhancements leading cm enhancements by −16 ± 8 days. The turnover frequency was found to vary between 21 and 69 GHz during our observations. By assuming a synchrotron self-absorption model for the relativistic jet emission in S5 0716+714, we found the magnetic field strength in the mas emission region to be ≤5 mG during the observing period, yielding a weighted mean of 1.0 ± 0.6 mG for higher turnover frequencies (e.g., >45 GHz).

79 ASTRONOMY AND ASTROPHYSICS↗

Contribution of X/Ka VLBI to Multi-Wavelength Celestial Frame Studies

This paper is an update of Sotuela et al. (2011) which improves their simulated Gaia frame tie precision by approximately 10% by adding three additional VLBI observing sessions. Astrometry at X/Ka-band (8.4/32 GHz) using NASAs Deep Space Network has detected 466 quasars with accuracies of 200-300 micro-arc seconds. A program is underway to reduce errors by a factor of 2-3. From our sample, 245 sources have optical magnitudes V less than 20 and should also be detectable by Gaia. A covariance study using existing X/Ka data and simulated Gaia uncertainties for the 345 objects yields a frame tie precision of 10-15 micro-arc seconds (1 - sigma). The characterization of wavelength dependent systematic from extended source morphology and core shift should benefit greatly from adding X/Ka-band measurements to S/X-band (2.3/8.4 GHz) measurements thus helping to constrain astrophysical models of the wavelength dependence of positions.

galaxies↗