202 records · Page 3

Three-Dimensional, Multi-Phase Unsteady Flow of Water Undergoing Multiple Flow Regimes (Free Surface, Droplet, and Fluid Film)

Upgrades to the Mobile Launcher Rainbird nozzles were implemented for the Artemis II launch to increase water flow rates and improve the mobile launcher deck water coverage while minimizing the water throw distance to avoid impacting the Space Launch System (SLS) rocket nozzles. This analysis describes the use of a three-dimensional, multi-phase, free surface transient computational fluid dynamics (CFD) model to simulate the water flowing out through the Rainbird nozzle and ensure compliance with current Artemis requirements. Flow rates, pressures, velocities, nozzle throw distances and coverage areas were analyzed to ensure that system requirements are met. The completed results were used to make necessary modifications to the Ignition Overpressure Protection and Sound Suppression (IOP/SS) system Rainbird design by reshaping the nozzle used in the system.

CFD

Performance Results of a Digital Test Signal Generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (P c /N o ) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

B O Gutierrez-Luaces

Mariner Mars 1971 battery design, test, and flight performance

The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

Bogner, R. S.

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft

Skylab Experiment M552: Exothermic Brazing

The M552 Skylab experiment reveals that brazing in space is feasible. It successfully demonstrated the ability to retain molten metal within a braze tube joint system. Surface energy was the dominant operative force system controlling liquid metal for this experiment. The zero gravity environment for brazing resulted in several differences; increased solubility, increased liquid spreading, more uniform menisci (liquid/vapor interface) and a reduction of braze alloy shrinkage defects. The residual radioactive intensity and location of the redistributed isotope was interpreted to provide a sequential history of braze alloy movement during the melt-flow-solidification stages of the process. Convection theory applied to M552 was validated but some results were not explainable by it, i.e., increased nickel transport and the radial mixing of the silver isotope on samples SLN-2 and SLN-4. All characteristics of thermal analysis appeared to react as expected but heat conduction rates increased because of increased extent, rate and uniformity of braze alloy spreading.

J R Williams

Bipolar and Monopolar Lithium-Ion Battery Technology at Yardney

Lithium-ion battery systems offer several advantages: intrinsically safe; long cycle life; environmentally friendly; high energy density; wide operating temperature range; good discharge rate capability; low self-discharge; and no memory effect.

Russell, P.

Battery failure model derived from flaw theory

A previously derived failure model for battery lifetime is discussed in terms of growth rate of the flaw, distribution of flaw sizes, and number of flaws. Equations are presented for determining the failure model for a nickel cadmium battery.

Schulman, I.

RTE: A Computer Code for Rocket Thermal Evaluation

The numerical model for a rocket thermal analysis code (RTE) is discussed. RTE is a comprehensive thermal analysis code for thermal analysis of regeneratively cooled rocket engines. The input to the code consists of the composition of fuel/oxidant mixture and flow rates, chamber pressure, coolant temperature and pressure. dimensions of the engine, materials and the number of nodes in different parts of the engine. The code allows for temperature variation in axial, radial and circumferential directions. By implementing an iterative scheme, it provides nodal temperature distribution, rates of heat transfer, hot gas and coolant thermal and transport properties. The fuel/oxidant mixture ratio can be varied along the thrust chamber. This feature allows the user to incorporate a non-equilibrium model or an energy release model for the hot-gas-side. The user has the option of bypassing the hot-gas-side calculations and directly inputting the gas-side fluxes. This feature is used to link RTE to a boundary layer module for the hot-gas-side heat flux calculations.

Mohammad H N Naraghi

Test Results of a Ten Cell Bipolar Nickel-hydrogen Battery

A study was initiated to design and evaluate a new design concept for nickel-hydrogen cells. This concept involved constructing a battery in a bipolar stack with cells consisting of a one plate for each nickel and hydrogen electrode. Preliminary designs at the system level of this concept promised improvements in both volumetric and gravimetric energy densities, thermal management, life extension, costs, and peak power capability over more conventional designs. Test results were most encouraging. This preprototype battery, built with less than ideal components and hardware, exceeded expectations. A total of 2000 LEO cycles at 80 percent depth of discharge were accrued. A cycle life goal of 30,000 cycles appears achievable with minor design changes. These improvements include advanced technology nickel electrodes, insulated bipolar plates and specifically designed frames to minimize shunt currents. The discharge rate capability of this design exceeds 25C. At the 10C discharge rate, 80% of the battery capacity can be withdrawn in six minutes. This data shows that the bipolar design is well suited for those applications requiring high peak power pulses.

Cataldo, R. L.

Battery charge regulator is coulometer controlled

Coulometer controlled battery charge regulator controls nickel/cadmium type primary cells used in space applications. The use of the coulometer as an ampere hour measuring device permits all available current to go to the battery until full charge state is reached, at which time the charge rate is automatically reduced.

Paulkovich, J.

Long Life Molten Salt Battery for NASA Venus Application

A development program is being conducted at Advanced Thermal Batteries (ATB) to create a low discharge rate, long life, molten salt battery for a NASA Venus surface probe. Battery goals are 60 days continuous operation at +25V +0/-6 volts and -25V +6/-0 Volts under severe environments of 465°C, 92 atm pressure, and corrosive sulfur dioxide in a super critical carbon dioxide atmosphere. Conveniently, molten salt thermal battery electrochemistry starts to operate efficiently at 330°C. However, a major barrier to direct application of existing thermal battery technology is the high self-discharge rate, resulting in lifetimes in only minutes, not days. The best performance to date, which meets the required voltage regulation, has been a lithium silicon (LiSi) alloy anode discharging through all three voltage plateau versus an iron monosulfide (FeS) cathode. In order to perform reproducibly, additional engineering controls within the battery design are required to limit cell–to–cell parasitic discharge mechanisms. Results of these trials have improved the efficiency and manufacturability of the design.

Thermal Battery

NiH2 Battery Reconditioning for LEO Applications

This paper summarizes reasons for and benefits of reconditioning nickel-hydrogen (NiH2) batteries used for Low Earth Orbit (LEO) applications. NiH2 battery cells do not have the classic discharge voltage problems more commonly associated with nickel-cadmium (NiCd) cells. This is due, in part, to use of hydrogen electrodes in place of cadmium electrodes. The nickel electrode, however, does have a similar discharge voltage signature for both cell designs. This can have an impact on LEO applications where peak loads at higher relative depths of discharge can impact operations. Periodic reconditioning provides information which can be used for analyzing long term performance trends to predict usable capacity to a specified voltage level. The reconditioning process described herein involves discharging NiH2 batteries at C/20 rates or less, to an average cell voltage of 1.0 volts or less. Recharge is performed at nominal C/5 rates to specified voltage/temperature (V/T) charge levels selected to restore required capacity with minimal overcharge. Reconditioning is a process of restoring reserve capacity lost on cycling, which is commonly called the memory effect in NiCd cells. This effect is characterized by decreases in the discharge voltage curve with operational life and cycling. The end effect of reconditioning NiH2 cells may be hidden in the versatility, of that design over the NiCd cell design and its associated negative electrode fading problem. The process of deep discharge at lower rates by way of reconditioning tends to redistribute electrolyte and water in the NiH2 cell electrode stack, while improving utilization and charge efficiency. NiH2 battery reconditioning effects on life are considered beneficial and may, in fact. extend life based on NiCd experience. In any case, usable capacity data obtained from reconditioning is required for performance evaluation and trend analysis. Characterization and life tests have provided the historical data base used to determine the need for reconditioning in most battery applications. The following sections briefly describe the background of NiH2 battery reconditioning and testing at Lockheed Martin Missiles & Space (LMMS) and other aerospace companies.

Armantrout, J. D.

Computation of three-dimensional mixed convective boundary layer flow

The paper presents the numerical solution of heat and mass transfer during cross-flow (orthogonal) mixed convection. In this class of flow, a buoyancy-driven transport in the vertical direction and a forced convective flow in the horizontal direction results in a three-dimensional boundary layer structure adjacent to the plate. The rates of heat and mass transfer are determined by a combined influence of the two transport processes. The equations for the conservation of mass, momentum, energy, and species concentration were solved along with appropriate boundary conditions to determine the distributions of velocity components, temperature, and concentration across the thickness of the boundary layer at different locations on the plate. Results were expressed in dimensionless form using Reynolds number, Richardson number for heat transfer, Richardson number for mass transfer, Prandtl number, and Schmidt number as parameters. It was found that the transport is dominated by buoyancy at smaller vertical locations and at larger distances away from the forced convection leading edge. Effects of forced convection appeared to be very strong at smaller horizontal distances from the leading edge. The cross stream forced convection enhanced the rate of heat and mass transfer by a very significant amount.

Prashandt Gadepalli

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot

Evaluation of AMSOIL® -ANT PGW Coolant Formula Change and Super Space AMSOIL Development

AMSOIL ® Propylene Glycol Water (PGW), is the baselined internal thermal control fluid for multiple manned spacecraft including Gateway (HALO, IHAB, and ALM modules) and Orion. The use of AMSOIL-ANT PGW was originally validated through extensive NASA/Collins materials-compatibility testing (circa 2008–2015). However, in late 2019, AMSOIL implemented an unannounced change in its PG inhibitor package. Because of this reformulation, concerns around materials compatibility arose. Therefore, NASA initiated corrosion rate and coolant stability testing in 2024. Results showed that the reformulated AMSOIL PG produced substantially elevated corrosion rates in aluminum alloys (about two times when compared to the original AMSOIL PG formula) accompanied by visible surface degradation. Coolant stability testing indicated accelerated propylene-glycol breakdown as well, with glycolate levels about nine times higher than the original formulation. Based on these findings, NASA Materials & Processes and Thermal Control Systems groups have baselined the use of the original PGW chemistry for all spacecraft use. In response, AMSOIL produced a reformulated variant, “Super Space AMSOIL” (ANT-SSA), compliant with MPCV 70156.This paper documents the reformulation testing completed, details on the formulation change, and the development of Super Space AMSOIL.

Woody Beringer

Evaluation of AMSOIL ® -ANT PGW Coolant Formula Change and Super Space AMSOIL ® Development

AMSOIL ® Propylene Glycol Water (PGW), is the baselined internal thermal control fluid for multiple manned spacecraft including Gateway (HALO, IHAB, and ALM modules) and Orion. The use of AMSOIL-ANT PGW was originally validated through extensive NASA/Collins materials-compatibility testing (circa 2008–2015). However, in late 2019, AMSOIL implemented an unannounced change in its PG inhibitor package. Because of this reformulation, concerns around materials compatibility arose. Therefore, NASA initiated corrosion rate and coolant stability testing in 2024. Results showed that the reformulated AMSOIL PG produced substantially elevated corrosion rates in aluminum alloys (about two times when compared to the original AMSOIL PG formula) accompanied by visible surface degradation. Coolant stability testing indicated accelerated propylene-glycol breakdown as well, with glycolate levels about nine times higher than the original formulation. Based on these findings, NASA Materials & Processes and Thermal Control Systems groups have baselined the use of the original PGW chemistry for all spacecraft use. In response, AMSOIL produced a reformulated variant, “Super Space AMSOIL” (ANT-SSA), compliant with MPCV 70156.This paper documents the reformulation testing completed, details on the formulation change, and the development of Super Space AMSOIL.

David Brockett

Microprocessor controlled advanced battery management systems

The advanced battery management system described uses the capabilities of an on-board microprocessor to: (1) monitor the state of the battery on a cell by cell basis; (2) compute the state of charge of each cell; (3) protect each cell from reversal; (4) prevent overcharge on each individual cell; and (5) control dual rate reconditioning to zero volts per cell.

W. T. Payne

Life cycle test results of a bipolar nickel hydrogen battery

A history is given of low Earth orbit (LEO) laboratory test data on a 6.5 ampere-hour bipolar nickel hydrogen battery designed and built at the NASA Lewis Research Center. The bipolar concept is a means of achieving the goal of producing an acceptable battery, of higher energy density, able to withstand the demands of low-Earth-orbit regimes. Over 4100 LEO cycles were established on a ten cell battery. It seems that any perturbation on normal cycling effects the cells performance. Explanations and theories of the battery's behavior are varied and widespread among those closely associated with it. Deep discharging does provide a reconditioning effect and further experimentation is planned in this area. The battery watt-hour efficiency is about 75 percent and the time averaged, discharge voltage is about 1.26 volts for all cells at both the C/4 and LEO rate. Since a significant portion of the electrode capacity has degraded, the LEO cycle discharges are approaching depths of 90 to 100 percent of the high rate capacity. Therefore, the low end-of-discharge voltages occur precipitously after the knee of the discharge curve and is more an indication of electrode capacity and is a lesser indicator of overall cell performance.