The Design of a Remotely Operated Shutter (ROS) for Thermal Vacuum Testing

Space-flight hardware is required to meet specific outgassing criteria under vacuum conditions in order to reduce the risk of contaminating sensitive optics and spacecraft components. Under certain circumstances, it is desirable to measure the contamination levels that are being released from all surfaces of the test payload. This certification is often accomplished with a Total Outgassing Measurement (TOM) box. The TOM box has one 103.2 square centimeter (16 square inch) opening and one 4.84 square centimeter (0.75 square inches) opening. The larger opening allows contaminants to easily escape the box during the hardware bakeout phase. The smaller opening provides a limited conductance path for outgassed contaminants during the certification phase. A Thermoelectric Quartz Crystal Microbalance (TQCM) monitors the contamination levels inside the box to provide the total outgassing measurement. During transition from the bakeout phase to the certification phase, the TOM box is reconfigured to close the larger opening. For previous certifications, the vacuum chamber was returned to ambient conditions and the larger conductance port was closed manually. The ROS system eliminates the need to enter the chamber by remotely closing the large TOM box opening. Substantial schedule and cost savings are achieved through the use of this system. The ROS system consists of three main components; a shutter, a motion actuator, and an actuator controller. Each of these components was selected or designed to operate in an extreme-temperature and vacuum environment while providing a high level of reliability. Different types of motion actuators were considered for driving the shutter. Design parameters for the actuator included material properties, force capability, reliability, and cost.

Hale, Kathleen L.↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗

Active pixel sensor array with electronic shuttering

An active pixel cell includes electronic shuttering capability. The cell can be shuttered to prevent additional charge accumulation. One mode transfers the current charge to a storage node that is blocked against accumulation of optical radiation. The charge is sampled from a floating node. Since the charge is stored, the node can be sampled at the beginning and the end of every cycle. Another aspect allows charge to spill out of the well whenever the charge amount gets higher than some amount, thereby providing anti blooming.

Fossum, Eric R.↗

High-speed electromechanical shutter for imaging spectrographs

The present invention presents a high-speed electromechanical shutter which has at least two rotary beam choppers that are synchronized using a phase-locked loop electronic control to reduce the duty cycle. These choppers have blade means that can comprise discs or drums, each having about 60 (+/-15) slots which are from about 0.3 to about 0.8 mm wide and about 5 to about 20 mm long (radially) which are evenly distributed through out 360?, and a third rotary chopper which is optically aligned has a small number of slots, such as for example, 1 to 10 slots which are about 1 to about 2 mm wide and about 5 to about 20 mm long (radially). Further the blade means include phase slots that allow the blade means to be phase locked using a closed loop control circuit. In addition, in a preferred embodiment, the system also has a leaf shutter. Thus the invention preferably achieves a gate width of less than about 100 microseconds, using motors that operate at 3000 to 10,000 rpm, and with a phase jitter of less than about 1.5 microseconds, and further using an aperture with more than about 75% optical transmission with a clear aperture of about 0.8 mm?10 mm. The system can be synchronized to external sources at 0 6 kHz lasers, data acquisition systems, and cameras.

Nguyen, Quang-Viet↗

Design and Manufacture of a Highly Reliable, Miniaturized and Low Mass Shutter Mechanism

This paper describes the development, manufacturing and testing of a lightweight shutter mechanism made of titanium for the MERTIS Instrument. MERTIS is a thermal infrared imaging spectrometer onboard ESA's future BepiColombo mission to Mercury. The mechanism is built as a parallelogram arrangement of flexible hinges, actuated by a voice coil. In a first test run, it was shown that the selected EDM processing led to the generation of titanium oxides and an oxygen-enriched surface layer on the substrate (so called alpha-case layer). In the revised version of the shutter, it was possible to manufacture the complex geometry by micro-milling and an adjacent pickling procedure. The adequacy of this approach was verified by lifetime and vibration testing.

Manhart, M.↗

Ray-Tracing Simulations Characterising the Performance of the Proposed 2024 HFIR HB4 Main Shutter

The Main Shutter at HB4 will serve two purposes after the HFIR Beryllium Reflector Replacement planned to take place in 2024. First as the primary certified safety control controlling the passage of neutrons from the cold source in the HFIR pressure vessel into the cold guide hall, and second as the first set of reflecting surfaces used to guide neutrons from the source and into the individual guide starts for each instrument in the cold guide hall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic shutter gates image orthicon on and off

TV camera system contains an electronic shutter that gates the image orthicon photocathode on during expose time and off at all other times. The system records image of diffuse light-scattering regions in the solar system.

Sensening, W. A.↗