Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated Signal Timing Plan Reconstruction Using High-Resolution Event-Based Controller Data for Digital Twins

Transportation digital twins are essential tools for evaluating emerging technologies such as connected and automated vehicles, adaptive traffic signal control, and mobility optimization strategies. Realistic digital twins require accurate emulation of real-world signal controllers and detailed signal timing plans. However, signal timing plans are often unavailable or difficult to access, forcing researchers and modelers to rely on assumed fixed timings or halt their analysis. To overcome this challenge, we present a method that directly estimates signal timing plan parameters using high-resolution, event-based data from traffic signal controllers. The proposed method extracts key parameters, including cycle length, offset, phase sequence, coordinated phases, phase-specific minimum and maximum green durations, vehicle extensions, and splits under coordination. A rule-based deterministic signal timing reconstruction algorithm based on traffic signal operation rules, such as those outlined in the Signal Timing Manual, is developed and validated. We evaluate this method, which uses high-resolution controller event logs and verified signal timing plans, on 94 signalized intersections in Nashville, Tennessee, demonstrating their ability to generate accurate, simulation-ready signal timing plans for tools such as SUMO and Vissim.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

Wavelet Methods Developed to Detect and Control Compressor Stall

A "wavelet" is, by definition, an amplitude-varying, short waveform with a finite bandwidth (e.g., that shown in the first two graphs). Naturally, wavelets are more effective than the sinusoids of Fourier analysis for matching and reconstructing signal features. In wavelet transformation and inversion, all transient or periodic data features (as in compressor-inlet pressures) can be detected and reconstructed by stretching or contracting a single wavelet to generate the matching building blocks. Consequently, wavelet analysis provides many flexible and effective ways to reduce noise and extract signals which surpass classical techniques - making it very attractive for data analysis, modeling, and active control of stall and surge in high-speed turbojet compressors. Therefore, fast and practical wavelet methods are being developed in-house at the NASA Lewis Research Center to assist in these tasks. This includes establishing user-friendly links between some fundamental wavelet analysis ideas and the classical theories (or practices) of system identification, data analysis, and processing.

Le, Dzu K.↗

Enhanced Data-Acquisition System

Time-consuming, costly digitization of analog signals on magnetic tape eliminated. Proposed data-acquisition system provides nearly immediate access to data in incoming signals by digitizing and recording them both on magnetic tape and on optical disk. Tape and/or disk later played back to reconstruct signals in analog or digital form for analysis. Of interest in industrial and scientific applications in which necessary to digitize, store, and/or process large quantities of experimental data.

Mustain, Roy W.↗

The NIFTY way of Bayesian signal inference

We introduce NIFTY, 'Numerical Information Field Theory', a software package for the development of Bayesian signal inference algorithms that operate independently from any underlying spatial grid and its resolution. A large number of Bayesian and Maximum Entropy methods for 1D signal reconstruction, 2D imaging, as well as 3D tomography, appear formally similar, but one often finds individualized implementations that are neither flexible nor easily transferable. Signal inference in the framework of NIFTY can be done in an abstract way, such that algorithms, prototyped in 1D, can be applied to real world problems in higher-dimensional settings. NIFTY as a versatile library is applicable and already has been applied in 1D, 2D, 3D and spherical settings. A recent application is the D{sup 3}PO algorithm targeting the non-trivial task of denoising, deconvolving, and decomposing photon observations in high energy astronomy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters are recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(omega(sub 1)), where omega(sub 1) is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Three-wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters arc recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(sub omega1), where omega, is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Multiwire Thermocouples in Reversing Flow

Measurements are recorded for multiwire thermocouples consisting of either two or three wires of unequal diameters. Signals from the multiwire probe are recorded for a reversing gas flow with both a periodic temperature and time constant fluctuation. It is demonstrated that the reconstructed signal from the multiwire thermocouple requires no compensation provided omega/omega(sub 1) less than 2.3 for two wires or omega/omega(sub 1) less than 3.6 for three wires where omega(sub 1) (= 2(pi)f) is the natural frequency of the smaller wire based on the maximum gas velocity. The latter results were possible provided Fourier transformed data from the wires were used and knowledge of the gas velocity phase angle was available.

Forney, L. J.↗

Intermolecular correlations are necessary to explain diffuse scattering from protein crystals

Conformational changes drive protein function, including catalysis, allostery, and signaling. X-ray diffuse scattering from protein crystals has frequently been cited as a probe of these correlated motions, with significant potential to advance our understanding of biological dynamics. However, recent work challenged this prevailing view, suggesting instead that diffuse scattering primarily originates from rigid body motions and could therefore be applied to improve structure determination. To investigate the nature of the disorder giving rise to diffuse scattering, and thus the potential applications of this signal, a diverse repertoire of disorder models was assessed for its ability to reproduce the diffuse signal reconstructed from three protein crystals. This comparison revealed that multiple models of intramolecular conformational dynamics, including ensemble models inferred from the Bragg data, could not explain the signal. Models of rigid body or short-range liquid-like motions, in which dynamics are confined to the biological unit, showed modest agreement with the diffuse maps, but were unable to reproduce experimental features indicative of long-range correlations. Extending a model of liquid-like motions to include disorder across neighboring proteins in the crystal significantly improved agreement with all three systems and highlighted the contribution of intermolecular correlations to the observed signal. These findings anticipate a need to account for intermolecular disorder in order to advance the interpretation of diffuse scattering to either extract biological motions or aid structural inference.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-wideband radios for time-of-flight-ranging and network position estimation

This invention provides a novel high-accuracy indoor ranging device that uses ultra-wideband (UWB) RF pulsing with low-power and low-cost electronics. A unique of the present invention is that it exploits multiple measurements in time and space for very accurate ranging. The wideband radio signals utilized herein are particularly suited to ranging in harsh RF environments because they allow signal reconstruction in spite of multipath propagation distortion. Furthermore, the ranging and positioning techniques discussed herein directly address many of the known technical challenges encountered in UWB localization regarding synchronization and sampling. In the method developed, noisy, corrupted signals can be recovered by repeating range measurements across a channel, and the distance measurements are combined from many locations surrounding the target in a way that minimizes the range biases associated to indirect flight paths and through-wall propagation delays.

47 OTHER INSTRUMENTATION↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Operation and performance of the ATLAS tile calorimeter in LHC Run 2

The ATLAS tile calorimeter (TileCal) is the hadronic sampling calorimeter covering the central region of the ATLAS detector at the Large Hadron Collider (LHC). This paper gives an overview of the calorimeter’s operation and performance during the years 2015–2018 (Run 2). In this period, ATLAS collected proton–proton collision data at a centre-of-mass energy of 13 TeV and the TileCal was 99.65% efficient for data-taking. The signal reconstruction, the calibration procedures, and the detector operational status are presented. The performance of two ATLAS trigger systems making use of TileCal information, the minimum-bias trigger scintillators and the tile muon trigger, is discussed. Studies of radiation effects allow the degradation of the output signals at the end of the LHC and HL-LHC operations to be estimated. Finally, the TileCal response to isolated muons, hadrons and jets from proton–proton collisions is presented. The energy and time calibration methods performed excellently, resulting in good stability and uniformity of the calorimeter response during Run 2. The setting of the energy scale was performed with an uncertainty of 2%. The results demonstrate that the performance is in accordance with specifications defined in the Technical Design Report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electro optical system to measure strains at high temperature

The goals of this proposal were to develop a prototype of an electro-optics system for the measurement of strains in structures at high temperatures and to perform a test under field conditions. In the research task section, the topics addressed include: (1) correction of the effect of vibrations and thermal currents by means of an active compensation system; (2) reduction of the speckle noise by means of electronic filter and TV signal reconstruction circuit; (4) compensation of the rigid body motions by mounting the camera in a universal motion system; and (5) removal of phase errors left by the active compensation system by dynamic reading. In the design and construction section, the topics addressed include: (1) preliminary design; (2) final design; (3) software development; (4) signal conditioning; (5) data processing; (6) recorrelation of two holograms in the presence of rigid body motions; and (7) phase extraction using a computer generated image. Testing in the high temperature oven is also addressed.

Sciammarella, Cesar A.↗

Synthetic aperture radar signal data compression using block adaptive quantization

This paper describes the design and testing of an on-board SAR signal data compression algorithm for ESA's ENVISAT satellite. The Block Adaptive Quantization (BAQ) algorithm was selected, and optimized for the various operational modes of the ASAR instrument. A flexible BAQ scheme was developed which allows a selection of compression ratio/image quality trade-offs. Test results show the high quality of the SAR images processed from the reconstructed signal data, and the feasibility of on-board implementation using a single ASIC.

Kuduvalli, Gopinath↗

CMB lensing reconstruction in the presence of diffuse polarized foregrounds

The measurement and characterization of the lensing of the cosmic microwave background (CMB) is key goal of the current and next generation of CMB experiments. We perform a case study of a three-channel balloon-borne CMB experiment observing the sky at (l,b)=(250°,−38°) and attaining a sensitivity of 5.25 μK−arcmin with 8' angular resolution at 150 GHz, in order to assess whether the effect of polarized Galactic dust is expected to be a significant contaminant to the lensing signal reconstructed using the EB quadratic estimator. We find that for our assumed dust model, polarization fractions of about as low as a few percent may lead to a significant dust bias to the lensing convergence power spectrum. We investigated a parametric component separation method, proposed by Stompor et al. (2009), as well as a template cleaning method, for mitigating the effect of this dust bias. The template-based method recovers unbiased convergence power spectrum in all polarization fraction cases we considered, while for the component separation technique we find a dust contrast regime in which the accuracy of the profile likelihood spectral index estimate breaks down, and in which external information on the dust frequency scaling is needed. We propose a criterion for putting a requirement on the accuracy with which the dust spectral index must be estimated or constrained, and demonstrate that if this requirement is met, then the dust bias can be removed.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB lensing power spectrum biases from galaxies and clusters using high-angular resolution temperature maps

The lensing power spectrum from cosmic microwave background (CMB) temperature maps will be measured with unprecedented precision with upcoming experiments, including upgrades to the Atacama Cosmology Telescope and the South Pole Telescope. Achieving significant improvements in cosmological parameter constraints, such as percent level errors on σ{sub 8} and an uncertainty on the total neutrino mass of ∼50 meV, requires percent level measurements of the CMB lensing power. This necessitates tight control of systematic biases. We study several types of biases to the temperature-based lensing reconstruction signal from foreground sources such as radio and infrared galaxies and the thermal Sunyaev-Zel'dovich effect from galaxy clusters. These foregrounds bias the CMB lensing signal due to their non-Gaussian nature. Using simulations as well as some analytical models we find that these sources can substantially impact the measured signal if left untreated. However, these biases can be brought to the percent level if one masks galaxies with fluxes at 150 GHz above 1 mJy and galaxy clusters with masses above M {sub vir} = 10{sup 14} M {sub ☉}. To achieve such percent level bias, we find that only modes up to a maximum multipole of l {sub max} ∼ 2500 should be included in the lensing reconstruction. We also discuss ways to minimize additional bias induced by such aggressive foreground masking by, for example, exploring a two-step masking and in-painting algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Compressed Sensing to 2-D Ultrasonic Propagation Imaging System data

The Ultrasonic Propagation Imaging (UPI) System is a unique, non-contact, laser-based ultrasonic excitation and measurement system developed for structural health monitoring applications. The UPI system imparts laser-induced ultrasonic excitations at user-defined locations on a structure of interest. The response of these excitations is then measured by piezoelectric transducers. By using appropriate data reconstruction techniques, a time-evolving image of the response can be generated. A representative measurement of a plate might contain 800x800 spatial data measurement locations and each measurement location might be sampled at 500 instances in time. The result is a total of 640,000 measurement locations and 320,000,000 unique measurements. This is clearly a very large set of data to collect, store in memory and process. The value of these ultrasonic response images for structural health monitoring applications makes tackling these challenges worthwhile. Recently compressed sensing has presented itself as a candidate solution for directly collecting relevant information from sparse, high-dimensional measurements. The main idea behind compressed sensing is that by directly collecting a relatively small number of coefficients it is possible to reconstruct the original measurement. The coefficients are obtained from linear combinations of (what would have been the original direct) measurements. Often compressed sensing research is simulated by generating compressed coefficients from conventionally collected measurements. The simulation approach is necessary because the direct collection of compressed coefficients often requires compressed sensing analog front-ends that are currently not commercially available. The ability of the UPI system to make measurements at user-defined locations presents a unique capability on which compressed measurement techniques may be directly applied. The application of compressed sensing techniques on this data holds the potential to reduce the number of required measurement locations, reduce the time to make measurements, reduce the memory required to store the measurements, and possibly reduce the computational burden to classify the measurements. This work considers the appropriate selection of the signal dictionary used for signal reconstruction, and performs an evaluation of compressed sensing technique's ability to reconstruct ultrasonic images using fewer measurements than would be needed using traditional Nyquist-limited data collection techniques.

42 ENGINEERING↗

Uncovering electronic and geometric descriptors of chemical activity for metal alloys and oxides using unsupervised machine learning

Here, we show that unsupervised machine learning (ML) using principal component analysis (PCA) provides a straightforward pathway for developing accurate and interpretable electronic-structure descriptors of the chemical and catalytic properties of materials. We demonstrate the approach by finding chemisorption descriptors for metal alloys and surface oxygens on metals and metal oxides. In both cases, the principal component (PC) descriptors yield ML models that predict the material’s chemical properties with competitive accuracy compared to ML models built using established descriptors. Importantly, interpreting the electronic-structure patterns captured by each PC descriptor via signal reconstruction suggests potential design motifs for future electronic-structure descriptor design and allows us to identify links between a material’s geometric and catalytic properties. Ultimately, we show that the unsupervised ML approach provides a route to find electronic-structure descriptors of the catalytic properties of materials that readily connect to geometric structure and composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optical-input Maximum Likelihood Estimation feedback system demonstrated on tokamak horizontal equilibrium control

A readily parallelized Maximum Likelihood Estimation (MLE) algorithm with linear computational complexity is demonstrated in real time using only measurements from an extreme ultraviolet (EUV) diagnostic to control the horizontal position of a tokamak plasma. A set of trial emissivity profiles are parameterized by the control quantity of interest (R m ), and the MLE is identified from the profile which minimizes the signal reconstruction residual. The algorithm depends on an empirically determined likelihood function with exponential form. EUV emission (λ ≈ 15eV-1keV) is captured in a poloidal plane by four 16-channel AXUV diodes mounted at different poloidal angles with radial and angular resolution sufficient to discern plasma equilibrium evolution in HBT-EP. Calculations of the plasma major radius by the system are consistent within diagnostic uncertainty for the majority of the discharge with those of: a weighted average of vertical soft X-ray or EUV chords, magnetic sensors, and an equilibrium reconstruction. The feedback system corrects for a horizontal displacement of the major radius equal to 20% of the plasma minor radius by adjusting the vertical field produced from 40 in-vessel control coils in real time. The MLE calculation is performed on a GPU in a 15 μs cycle, with similar performance in this application to a simple weighted average of vertical chords. Finally, results demonstrate horizontal position control using magnetic actuators and an optical observer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗