Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Charge collected by diffusion from an ion track under mixed boundary conditions

Charge-carrier diffusion from an ion track in a silicon substrate at least a few hundred microns thick is analyzed. The substrate upper surface is treated as reflective except for a small section, intended to represent a reverse-biased junction, which is treated as a sink. Total charge collected by the sink is calculated by assuming transport to be governed by an ambipolar diffusion equation with temporally constant and spatially uniform carrier lifetime and diffusion coefficient. Present results apply to a normally incident track but could easily be generalized to arbitrary track direction. The collected charge is found to depend on track length and on the electrostatic capacitance, rather than the area, of the sink. Theoretical predictions are compared to the results of a numerical simulation called the Poisson and Continuity Equation Solver (PISCES) for three cases and are found to agree within a factor of two in the worst case.

Edmonds, Larry D.↗

Development of a Silicon Tracker for the All-Sky Medium Energy Gamma-ray Observatory Prototype

The gamma-ray sky from several hundred keV to a hundred MeV has remained largely unexplored due to the challenging nature of detecting gamma rays in this regime. At lower energies, Compton scattering is the dominant interaction process whereas at higher energies pair production dominates, with a crossover at a few MeV. Thus, an instrument designed to work in this energy range must be optimized for both Compton and pair-production events. AMEGO, the All-sky Medium Energy Gamma-ray Observatory, a Probe-class mission in consideration for the 2020 decadal survey, is designed to operate at energies from 200 keV to > 10 GeV with over an order of magnitude increase in sensitivity and with superior angular and energy resolution compared to previous instruments. AMEGO comprises four major subsystems: a plastic anticoincidence detector for rejecting cosmic-ray events, a silicon tracker for tracking pair-production products and tracking and measuring the energies of Compton-scattered electrons, a cadmium-zinc-telluride (CZT) calorimeter for measuring the energy and location of Compton scattered photons, and a CsI calorimeter for measuring the energy of the pair-production products at high energies. A prototype instrument, known as ComPair, is under development at NASA’s Goddard Space Flight Center and the US Naval Research Laboratory. In this contribution, we provide details on the development of the silicon tracker subsystem.

Griffin, Sean↗

The Event Detection System in the NEXT-White Detector

This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Event Gate Rupture in Power MOSFETs: A New Radiation Hardness Assurance Approach

Almost every space mission uses vertical power metal-semiconductor-oxide field-effect transistors (MOSFETs) in its power-supply circuitry. These devices can fail catastrophically due to single-event gate rupture (SEGR) when exposed to energetic heavy ions. To reduce SEGR failure risk, the off-state operating voltages of the devices are derated based upon radiation tests at heavy-ion accelerator facilities. Testing is very expensive. Even so, data from these tests provide only a limited guide to on-orbit performance. In this work, a device simulation-based method is developed to measure the response to strikes from heavy ions unavailable at accelerator facilities but posing potential risk on orbit. This work is the first to show that the present derating factor, which was established from non-radiation reliability concerns, is appropriate to reduce on-orbit SEGR failure risk when applied to data acquired from ions with appropriate penetration range. A second important outcome of this study is the demonstration of the capability and usefulness of this simulation technique for augmenting SEGR data from accelerator beam facilities. The mechanisms of SEGR are two-fold: the gate oxide is weakened by the passage of the ion through it, and the charge ionized along the ion track in the silicon transiently increases the oxide electric field. Most hardness assurance methodologies consider the latter mechanism only. This work demonstrates through experiment and simulation that the gate oxide response should not be neglected. In addition, the premise that the temporary weakening of the oxide due to the ion interaction with it, as opposed to due to the transient oxide field generated from within the silicon, is validated. Based upon these findings, a new approach to radiation hardness assurance for SEGR in power MOSFETs is defined to reduce SEGR risk in space flight projects. Finally, the potential impact of accumulated dose over the course of a space mission on SEGR susceptibility is explored. SEGR evaluation of gamma-irradiated power MOSFETs suggests a non-significant SEGR susceptibility enhancement due to accumulated dose from gamma rays. During SEGR testing, an unexpected enhanced dose effect from heavy-ion irradiation was detected. We demonstrate that this effect could be due to direct ionization by two or more ions at the same channel location. The probability on-orbit for such an occurrence is near-zero given the low heavy-ion fluence over a typical mission lifetime, and did not affect SEGR susceptibility. The results of this work can be used to bound the risk of SEGR in power MOSFETs considered for insertion into spacecraft and instruments.

Lauenstein, Jean-Marie↗

An initial comparative assessment of orbital and terrestrial central power systems

Orbital solar power plants, which beam power to earth by microwave, are compared with ground-based solar and conventional baseload power plants. Candidate systems were identified for three types of plants and the selected plant designs were then compared on the basis of economic and social costs. The representative types of plant selected for the comparison are: light water nuclear reactor; turbines using low BTU gas from coal; central receiver with steam turbo-electric conversion and thermal storage; silicon photovoltaic power plant without tracking and including solar concentration and redox battery storage; and silicon photovoltaics.

Caputo, R.↗

Collection Of Charge By Diffusion From Ion Track

Collection of electric charge carriers from track of energetic ion through silicon electronic device studied using diffusion model representing transport of charge from ion track to sink. Effects of ionizing radiation approximated by simple equations.

Edmonds, Larry D.↗

The Gamma-ray Large Area Space Telescope (GLAST) Mission Concept Study

The Gamma-ray Large Area Space Telescope (GLAST), a next generation high-energy gamma-ray mission designed to observe cosmic sources of gamma-rays over the approximate energy range from 10 MeV to 300 GeV, was studied for possible flight in the next decade. The GLAST baseline mission studied will achieve a major advance in sensitivity beyond EGRET by the use of modern particle physics tracking technology. The baseline instrument design that has been extensively studied uses solid-state silicon strip detectors for particle tracking and efficient on-board data processing and event triggering to achieve more than an order of magnitude improvement in sensitivity compared to EGRET. Development of technology requirements and a technology development roadmap for the GLAST mission is presented.

Michelson, Peter F.↗

Pointing Reference Scheme for Free-Space Optical Communications Systems

A scheme is proposed for referencing the propagation direction of the transmit laser signal in pointing a free-space optical communications terminal. This recently developed scheme enables the use of low-cost, commercial silicon-based sensors for tracking the direction of the transmit laser, regardless of the transmit wavelength. Compared with previous methods, the scheme offers some advantages of less mechanical and optical complexity and avoids expensive and exotic sensor technologies. In free-space optical communications, the transmit beam must be accurately pointed toward the receiver in order to maintain the communication link. The current approaches to achieve this function call for part of the transmit beam to be split off and projected onto an optical sensor used to infer the pointed direction. This requires that the optical sensor be sensitive to the wavelength of the transmit laser. If a different transmit wavelength is desired, for example to obtain a source capable of higher data rates, this can become quite impractical because of the unavailability or inefficiency of sensors at these wavelengths. The innovation proposed here decouples this requirement by allowing any transmit wavelength to be used with any sensor. We have applied this idea to a particular system that transmits at the standard telecommunication wavelength of 1,550 nm and uses a silicon-based sensor, sensitive from 0.5 to 1.0 micrometers, to determine the pointing direction. The scheme shown in the figure involves integrating a low-power 980-nm reference or boresight laser beam coupled to the 1,550-nm transmit beam via a wavelength-division-multiplexed fiber coupler. Both of these signals propagate through the optical fiber where they achieve an extremely high level of co-alignment before they are launched into the telescope. The telescope uses a dichroic beam splitter to reflect the 980- nm beam onto the silicon image sensor (a quad detector, charge-coupled device, or active-pixel-sensor array) while the 1,550- nm signal beam is transmitted through the optical assembly toward the remotely located receiver. Since the 980-nm reference signal originates from the same single-mode fiber-coupled source as the transmit signal, its position on the sensor is used to accurately determine the propagation direction of the transmit signal. The optics are considerably simpler in the proposed scheme due to the use of a single aperture for transmitting and receiving. Moreover, the issue of mechanical misalignment does not arise because the reference signal and transmitted laser beams are inherently co-aligned. The beam quality of the 980-nm reference signal used for tracking is required to be circularly symmetric and stable at the tracking-plane sensor array in order to minimize error in the centroiding algorithm of the pointing system. However, since the transmit signal is delivered through a fiber that supports a single mode at 1,550 nm, propagation of higher order 980-nm modes is possible. Preliminary analysis shows that the overall mode profile is dominated by the fundamental mode, giving a near symmetric profile. The instability of the mode was also measured and found to be negligible in comparison to the other error contributions in the centroid position on the sensor array.

Wright, Malcolm↗

The ATLAS ITk Strip detector system for the Phase-II LHC upgrade

In the view of the luminosity increase foreseen by the High-Luminosity Large Hadron Collider program at CERN, the ATLAS experiment initiated an R&D program to replace its complete inner detector (ID) system. The new Inner Tracker (ITk) system, anticipated to be installed by 2028, will be a new all-silicon based tracker including Strip and Pixel detector technologies. The new detector is designed to meet the requirements of operating under a harsh environment namely, high radiation levels, increased pile-up and data rates while decrease the material budget and maintain or even improve the performance. The Strip project has advanced in several areas the last years while facing challenges moving from pre-production to production. Here, this manuscript gives an overview of the ITk Strip system and describes the advancements and challenges to date.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam Test Characterization of an Irradiated Pixel-Strip Module for HL_LHC CMS Tracker Upgrade

A new tracker, for the CMS detector at The Large Hadron Collider, will be built to address the demands of the High Luminosity upgrade which aims to achieve peak instantaneous luminosities from 5 up to 7.5 10^34 cm^-2 s^-1 and an integrated luminosity of 3000 4000 fb^-1 at a center of mass energy of 14 TeV. To meet the resulting challenges, the CMS experiment is changing its outer tracker silicon modules to include tracking capabilities at the Level-1 trigger. As part of this upgrade effort, a prototype module, combining both pixel and strip sensors (PS-module), was irradiated and subsequently tested at the Fermilab Test Beam and Irradiation facilities. These tests evaluated the module's ability to maintain precise tracking, effective particle momentum discrimination, and consistent performance when exposed to the radiation levels expected in the High Luminosity LHC environment. Results from these studies are presented with a focus on comparing the module's performance before and after irradiation.

43 PARTICLE ACCELERATORS↗

The Electron Spectrum above 20 GeV Measured by ATIC

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment has been flown from McMurdo, Antarctica in 2000-01 (test flight) and 2002-03 (science flight). ATIC is composed of a segmented BGO calorimeter following a carbon target with scintillator tracking layers and a Silicon matrix detector at the entrance. ATIC measures the composition and energy spectra of the nuclei plus electrons. We present the electron spectrum derived from the ATIC flights, from 20 GeV to 3 TeV, and compare it to existing very high energy measurements from emulsion chambers and to the results of galactic propagation calculations. The good energy resolution and high statistics in the ATIC data allow detailed astrophysical interpretation of the results.

Chang, J.↗

The Electron Spectrum above 20 GeV Measured by ATIC-2

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment has been flown from McMurdo, Antarctica in 2000-01 (test flight) and 2002-03 (science flight). ATIC is composed of a segmented BGO calorimeter following a carbon target with scintillator tracking layers and a Silicon matrix detector at the entrance. ATIC measures the composition and energy spectra of the nuclei plus electrons. We present the electron spectrum derived from the ATIC-2 science flight, from 20 GeV to 1.5 TeV, and compare it to existing very high energy measurements from emulsion chambers and to the results of galactic propagation calculations. The good energy resolution and high statistics in the ATIC data allow detailed astrophysical interpretation of the results.

Chang, J.↗

Module Testing Procedures and Results for the CMS Phase-2 Outer Tracker Upgrade at Fermilab

The High-Luminosity LHC (HL-LHC) will operate at significantly increased luminosities and is expected to deliver about 3000 $fb^{-1}$ of proton-proton collision data at $\sqrt{s}=14$ TeV over a decade of operation. To maintain efficient tracking and triggering performance under high pileup and radiation conditions, the CMS experiment is upgrading its tracking detector for Phase-2 operations. The upgraded Outer Tracker (OT) will consist of Pixel-Strip (PS) and Strip-Strip (2S) silicon modules capable of providing tracking information to the Level-1 trigger at 40 MHz. Production and qualification of OT modules have been ongoing for about one year across several assembly and testing centers in the US, Europe, India, and Pakistan, requiring extensive testing to ensure stable operation in the HL-LHC environment. Fermilab is responsible for the production and testing of a significant fraction of the OT modules. The testing activities include IV characterization of silicon sensors, noise and pedestal measurements, verification of communication between module components, and burn-in studies using cold-box systems operated under controlled thermal conditions. Results from module testing and qualification studies performed during production will be presented.

Baradia, Sweta [UC, Davis (main)]↗

Requirements, Status, and Plans for Track Reconstruction at the sPHENIX Experiment

sPHENIX is a new experiment that is being constructed at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. The primary physics goals of sPHENIX are to measure jets, their substructure, and the upsilon resonances in p+p, p+Au and Au+Au collisions. To realize these goals, a tracking system composed of a time projection chamber and several silicon detectors will be used to identify tracks that correspond to jets and upsilon decays. However, the sPHENIX experiment will collect approximately 200 PB of data utilizing a finite-sized computing center; thus, performing track reconstruction in a timely manner is a challenge due to the large occupancy of heavy-ion collisions. The sPHENIX experiment, its track reconstruction, and the need for implementing faster track-fitting algorithms, such as that provided by the A Common Tracking Software package, into the sPHENIX software stack are discussed.

Osborn, Joe↗

1D Projections Readout and Track Reconstruction for the SONTRAC Instrument

Neutron spectroscopy and imaging has improved considerably over the last decade with the advancement of modern scintillating materials and compact, low power readout devices. Though challenging to detect, fast (>0.5 MeV) neutrons are ubiquitous, contribute to the radiation exposure of astronauts and space hardware, and have been effectively used to examine physical processes both locally and within our heliosphere at large. The SOlar Neutron TRACking (SONTRAC) instrument is designed to measure neutrons between 20-200 MeV with good angular sensitivity. SONTRAC consists of orthogonally stacked scintillating fibers readout by silicon photomultipliers to detect and track the recoil protons from double scatter neutron events. Proton tracking provides high-resolution imaging of fast neutronsat energies where the bulk of solar and planetary neutrons resides. The SONTRAC readout system, algorithms for track reconstruction, and tracking performance are presented.

George Suarez↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

The detection of fast neutrons has important applications in several fields including solar, Geospace and planetary physics. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High-energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement is limited by short flight paths and small detector sizes characteristic of small satellite platforms. It is now possible to perform high-energy neutron measurements inside a large monolithic detector by imaging the recoil proton tracks, thus eliminating the need for a measure of the time-of-flight. The concept is based on a spectrometer assembled from numerous thin hydrogenous scintillating fibers that allow ionization track imaging. Fine grained readout is now possible with arrays of1-mm pitch silicon photomultipliers (SiPMs). The Solar Neutron TRACking (SONTRAC) instrument, equipped with scintillating fibers readout with SiPMs sensors, provides high-resolution, fine grained, imaging of fast (between 20-200 MeV) neutron scatters in a compact, low-power design ideal for small satellite(and aircraft) platforms. We discuss below applications of this technology and performance characteristics of the prototype SONTRAC instrument.

de Nolfo, Georgia A.↗

Depth-Resolved X-Ray Nanoimaging of Coherent and Incoherent Energy Transport in Silicon Carbide

Understanding lattice dynamics is crucial for optimizing the process of creating functional structures, such as laser writing of color-center defects. However, existing structural probes have difficulty measuring structural dynamics with submicrometer depth sensitivity. Here, in this study, a depth-resolved ultrafast X-ray nanodiffraction technique is developed to track the lattice dynamics of silicon carbide (SiC) in three dimensions. Upon laser excitation of an aluminum layer that acts as a heat and strain transducer, a specular Bragg peak of SiC shows an overall increase in the X-ray diffraction intensity rather than a peak shift. The relaxation dynamics of the increased intensity are significantly different when probed on and off the Bragg peak. The fast subnanosecond relaxation probed at the maximum of the Bragg peak is a result of the propagation of a coherent strain wave along the depth direction, while a slow relaxation probed at the wings of the Bragg peak reflects a localized incoherent lattice heating. To further visualize these processes, spatiotemporal maps were obtained by scanning the relative position and delay between the laser pump and X-ray probe beams, which capture the propagation of the strain wave, as well as a stationary structural distortion close to the aluminum/SiC interface. These depth-resolved structural measurements disentangle energy dissipation mechanisms in laser-excited SiC, and they open opportunities for finer control of, for example, the formation of optically addressable defect complexes central to quantum information applications.

X-ray nanodiffraction↗