Search NASASearch

SEARCH · Search NASA

Results for “Sink Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

354 records · Page 3

Characterization of Ternary NiTiPt High-Temperature Shape Memory Alloys

Pt additions substituted for Ni in NiTi alloys are known to increase the transformation temperature of the alloy but only at fairly high Pt levels. However, until now only ternary compositions with a very specific stoichiometry, Ni 50-x Pt x Ti 50 , have been investigated and then only to very limited extent. In order to learn more about this potential high-temperature shape memory alloy system, a series of over twenty alloys along and on either side of a line of constant stoichiometry between NiTi and TiPt were arc melted, homogenized, and characterized in terms of their microstructure, transformation temperatures, and hardness. The resulting microstructures were examined by scanning electron microscopy and the phase compositions quantified by energy dispersive spectroscopy. "Stoichiometric" compositions along a line of constant stoichiometry between NiTi to TiPt were essentially single phase but any deviations from a stoichiometry of (Ni,Pt) 50 Ti 50 resulted in the presence of at least two different intermetallic phases, depending on the overall composition of the alloy. Essentially all alloys, whether single or two-phase, still under went a martensitic transformation. It was found that the transformation temperatures were depressed with initial Pt additions but at levels greater than 10 at.% the transformation temperature increased linearly with Pt content. Also, the transformation temperatures were relatively insensitive to alloy stoichiometry within the range of alloys examined. Finally, the dependence of hardness on Pt content for a series of Ni 50-x Pt x Ti 50 alloys showed solution softening at low Pt levels, while hardening was observed in ternary alloys containing more than about 10 at.% Pt. On either side of these "stoichiometric" compositions, hardness was also found to increase significantly.

Transformation Temperatures

Bend Properties of Sapphire Fibers at Elevated Temperatures: Bend Survivability - 1

The effect of temperature on the bend radius that a c-axis-oriented sapphire fiber can withstand was determined for fibers of various diameter. Bend stress rupture tests were performed for times of 1-100 h and temperatures of 300-1700 C. Fibers would survive the bend test undeformed, would fracture or would deform. The bend survival radius was determined to be the radius above which no fibers fractured or deformed for a given time-temperature treatment. It was found that the ability of fibers to withstand curvature decreases substantially with time and increasing temperature and that fibers of smaller diameter (46-83 micron) withstood smaller bend radii than would be expected from just a difference in fiber diameter when compared with the bend results of the fibers of large diameter (144 micron). This was probably due to different flaw populations, causing high temperature bend failure for the tested sapphire fibers of different diameters.

Sapphire

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory

Management and Performance of APPLE Battery in High Temperature Environment

India's first experimental communication satellite, APPLE, carried a 12 AH Ni-Cd battery for supplying power during eclipse. Failure to deploy one of the two solar panels resulted in the battery operating in a high temperature environment, around 40 C. This also resulted in the battery being used in diurnal cycles rather than just half yearly eclipse seasons. The management and performance of the battery during its life of two years are described. An attempt to identify the probable degradation mechanisms is also made.

Suresh, M. S.

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen

High temperature resistant jet fuels

The thermal stability of aviation fuels is evaluated according to the ASTM D 2341 method. This characteristic is linked to the presence of generators of instability, mainly diolephins and N and S derivates. The objectives of the present work are as follows: to obtain, in the laboratory, kerosene which is thermally stable; the isolation and identification of generators of instability; and the regeneration of thermally unstable kerosenes.

Luis M. Peloche

Effect of Thermomechanical Processing on the Microstructure, Properties, and Work Behavior of a Ti50.5 Ni29.5 Pt20 High-Temperature Shape Memory Alloy

TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 °C, due to a reasonable balance of proper ties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti 50.5 Ni 29.5 Pt 20 alloy was processed using several techniques including single- pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti 50.5 Ni 29.5 Pt 20 alloy, including fine wire.

Grain Size

Precipitation Hardenable High Temperature Shape Memory Alloy

A composition of the invention is a high temperature shape memory alloy having high work output, and is made from (Ni+Pt+Y) x Ti (100-x) wherein x is present in a total amount of 49-55 atomic % Pt is present in a total amount of 10-30 atomic %, Y is one or more of Au, Pd. and Cu and is present in a total amount of 0 to 10 atomic %. The alloy has a matrix phase wherein the total concentration of Ni, Pt, and the one or more of Pd. Au, and Cu is greater than 50 atomic %.

Ronald D Noebe

Battery charge control with temperature compensated voltage limit

Battery charge control for orbiting spacecraft with mission durations from three to ten years, is a critical design feature that is discussed. Starting in 1974, the General Electric Space Systems Division designed, manufactured and tested battery systems for six different space programs. Three of these are geosynchronous missions, two are medium altitude missions and one is a near-earth mission. All six power subsystems contain nickel cadmium batteries which are charged using a temperature compensated voltage limit. This charging method was found to be successful in extending the life of nickel cadmium batteries in all three types of earth orbits. Test data and flight data are presented for each type of orbit.

Thierfelder, H. E.

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 – 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Reaction Control System

Atacama Cosmology Telescope A Measurement of Galaxy Cluster Temperatures Through Relativistic Corrections to the Thermal Sunyaev-Zeldovich Effect

The high electron temperature in galaxy clusters (> 1 keV or > 107 K) leads to corrections at the level of a few percent in their thermal Sunyaev-Zeldovich effect signatures. Both the size and frequency dependence of these corrections, which are known as relativistic temperature corrections, depend upon the temperature of the objects. In this work we exploit this effect to measure the average temperature of a stack of Compton-y selected clusters. Specifically, we apply the “spectroscopic method” and search for the temperature that best fits the clusters’ signal measured at frequencies from 30 to 545 GHz by the Atacama Cosmology Telescope and Planck satellite. We measure the average temperature of clusters detected in the Atacama Cosmology Telescope maps to be 8.5 2.4 keV, with an additional systematic error of comparable amplitude dominated by passband uncertainty. Upcoming surveys, such as the Simons Observatory and CMB-S4, have the potential to dramatically improve upon these measurements and thereby enable precision studies of cluster temperatures with millimeter observations. The key challenge for future observations will be mitigating instrumental systematic effects, which already limit this analysis.

William R Coulton

X-Ray Absorption Spectroscopy in High Temperature Oxidation of Metals and Alloys

An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.

Daniele Gozzi

The Use of Immersion Rigs for High Temperature Hydrogen Exposure Testing Within the Nuclear Thermal Rocket Element Environmental Simulator (NTREES): NTREES-5 Hydrogen Heat Exchanger (N5HHX-01)

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility at NASA’s Marshall Space Flight Center (MSFC) subjects materials and components typically found on nuclear thermal propulsion (NTP) systems to non-nuclear simulations of prototypic NTP reactor thermohydraulic environments. With 1.2 MW of inductive power available, the currently employed methods to simulate nuclear heating in NTREES consist of 1) inductively heating a test specimen, which typically cannot be performed on ceramic materials, or 2) heating gas that envelops the test specimen. The latter of these has provided a basis for developing so-called “immersion rigs” to be used in NTREES. Furthermore, immersion rigs are especially useful in the case of smaller, technically challenging test specimens. One such device, the “NTREES-5 Hydrogen Heat Exchanger” (N5HHX-01), designed and deployed to test small material coupons to ~0.5 g/s of 2800 K, 500 psi Hydrogen, is discussed herein. To achieve this desired delivery temperature level, the most suitable material for the N5HHX’s construction was pure tungsten, which imposed budgetary and manufacturing challenges. Also discussed in this paper is the design of the N5HHX rig’s sample container, which became the first iteration of improving NTREES small material coupon test operations by permitting rapid changeout of different material samples.

Reactor Testing

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Otto J Gregory