Search NASA⌕ Search

SEARCH · Search NASA

Results for “Site screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advancements in the Aerosol Robotic Network (AERONET) Version 3 database – automated near-real-time quality control algorithm with improved cloud screening for Sun photometer aerosol optical depth (AOD) measurements

The Aerosol Robotic Network (AERONET) has provided highly accurate, ground-truth measurements of the aerosol optical depth (AOD) using Cimel Electronique Sun–sky radiometers for more than 25 years. In Version 2 (V2) of the AERONET database, the near-real-time AOD was semiautomatically quality controlled utilizing mainly cloud-screening methodology, while additional AOD data contaminated by clouds or affected by instrument anomalies were removed manually before attaining quality-assured status (Level 2.0). The large growth in the number of AERONET sites over the past 25 years resulted in significant burden to the manual quality control of millions of measurements in a consistent manner. The AERONET Version 3 (V3) algorithm provides fully automatic cloud screening and instrument anomaly quality controls. All of these new algorithm updates apply to near-real-time data as well as post-field-deployment processed data, and AERONET reprocessed the database in 2018. A full algorithm redevelopment provided the opportunity to improve data inputs and corrections such as unique filter-specific temperature characterizations for all visible and near-infrared wavelengths, updated gaseous and water vapor absorption coefficients, and ancillary data sets. The Level 2.0 AOD quality-assured data set is now available within a month after post-field calibration, reducing the lag time from up to several months. Near-real-time estimated uncertainty is determined using data qualified as V3 Level 2.0 AOD and considering the difference between the AOD computed with the pre-field calibration and AOD computed with pre-field and post-field calibration. This assessment provides a near-real-time uncertainty estimate for which average differences of AOD suggest a +0.02 bias and one sigma uncertainty of 0.02, spectrally, but the bias and uncertainty can be significantly larger for specific instrument deployments. Long-term monthly averages analyzed for the entire V3 and V2 databases produced average differences (V3–V2) of +0.002 with a ±0.02 SD (standard deviation), yet monthly averages calculated using time-matched observations in both databases were analyzed to compute an average difference of −0.002 with a ±0.004 SD. The high statistical agreement in multiyear monthly averaged AOD validates the advanced automatic data quality control algorithms and suggests that migrating research to the V3 database will corroborate most V2 research conclusions and likely lead to more accurate results in some cases.

David M. Giles↗

Screening actuator locations for static shape control

Correction of shape distortion due to zero-mean normally distributed errors in structural sizes which are random variables is examined. A bound on the maximum improvement in the expected value of the root-mean-square shape error is obtained. The shape correction associated with the optimal actuators is also characterized. An actuator effectiveness index is developed and shown to be helpful in screening actuator locations in the structure. The results are specialized to a simple form for truss structures composed of nominally identical members. The bound and effectiveness index are tested on a 55-m radiometer antenna truss structure. It is found that previously obtained results for optimum actuators had a performance close to the bound obtained here. Furthermore, the actuators associated with the optimum design are shown to have high effectiveness indices. Since only a small fraction of truss elements tend to have high effectiveness indices, the proposed screening procedure can greatly reduce the number of truss members that need to be considered as actuator sites.

Haftka, Raphael T.↗

Cryogenic Quenching Process for Electronic Part Screening

The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

Sheldon, Douglas J.↗

Microbiological investigations

The crew microbiology program was conducted to evaluate lunar contamination, to detect potentially pathogenic microoganisms, to identify medically important microorganisms recovered from ill crewmen, to aid in diagnosis and treatment, and to collect microbiological data that would aid in elucidating the response of the crew microbial autoflora to the space flight environment and in evaluating the resultant effect on the crewmember. Microbiological sampling of selected sites in the command module was initiated in support of the quarantine program. During lunar quarantine missions, microbial screening was accomplished for all support personnel to be isolated with the returning crewman. Virology support for the Apollo project consisted of characterization of the viral and mycoplasma flora of the crewmembers and performance of viral serology for crewmembers, crew contacts, and key mission personnel. Procedures and results are discussed in detail.

James K. Ferguson↗

Study of Systems and Technology for Liquid Hydrogen Production Independent of Fossil Fuels

Based on Kennedy Space Center siting and logistics requirements and the nonfossil energy resources at the Center, a number of applicable technologies and system candidates for hydrogen production were identified and characterized. A two stage screening of these technologies in the light of specific criteria identified two leading candidates as nonfossil system approaches. Conceptual design and costing of two solar-operated, stand alone systems, one photovoltaic based on and the other involving the power tower approach reveals their technical feasibility as sited as KSC, and the potential for product cost competitiveness with conventional supply approaches in the 1990 to 1210 time period. Conventional water hydrolysis and hydrogen liquefaction subsystems are integrated with the solar subsystems.

Sprafka, R. J.↗

Wilson Corners SWMU 001 2015 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2015 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration John F. Kennedy Space Center, Florida. The objectives of the 2015 LTM event were to evaluate the groundwater flow direction and gradient, to monitor the vertical and horizontal extent of the volatile organic compounds (VOCs; including the upgradient and sidegradient extents, which are monitored every five years), and to monitor select locations internal to the dissolved groundwater plume. The 2015 LTM event included several upgradient and sidegradient monitoring wells that are not sampled annually to verify the extent of VOCs in this portion of the site. The December 2015 LTM groundwater sampling event included, depth to groundwater measurements, 40 VOC samples collected using passive diffusion bags, and one VOC sample collected using low-flow techniques. Additionally, monitoring well MW0052DD was overdrilled and abandoned using rotasonic drilling techniques. The following conclusions can be made based on the 2015 LTM results: groundwater flow is generally to the west with northwest and southwest flow components from the water table to approximately 55 feet below land surface (ft BLS); peripheral monitoring wells generally delineate VOCs to groundwater cleanup target levels (GCTLs) except for monitoring wells MW0088, MW0090, MW0095, and NPSHMW0039, which had vinyl chloride (VC) concentrations near the GCTL and MW0062, which had trichloroethene (TCE), cis-1,2-dichloroethenen (cDCE), and VC concentrations above natural attenuation default concentrations (NADCs); VOCs in interior downgradient wells generally fluctuate within historic ranges except for monitoring wells in the north-northwest portion of the site, which have increasing VC concentrations indicating potential plume migration and expansion; Historically, the vertical extents of the VOCs were delineated by monitoring wells screened greater than 60 ft BLS (MW0083 through MW0086, and MW0078). The 2015 LTM results indicate that concentrations of daughter product cDCE is greater than the NADC in MW0078 and that cDCE and VC are greater than NADCs in MW0130. TCE was greater than the GCTL in monitoring well MW130 and not detected above method detection limits (9 micrograms per Liter) in monitoring well MW0078. No GCTL exceedances were identified in monitoring wells MW0083 or MW0086; the dissolved plume footprint appears generally stable, though not fully delineated by monitoring well data in the northeast portion of the site; and 2015 LTM results generally support the existing Conceptual Site Model. Geosyntec recommends modifying the LTM program, collecting a verification sample from monitoring well MW0062, and performing a direct push technology instigation in the northnortheastern portion of the site. A cluster of monitoring wells (MW0132 [2 to 12 ft BLS], MW0133 [15 to 25 ft BLS], and MW0134 [29 to 34 ft BLS]) is proposed to delineate impacts in the northnortheast portion of the site. Geosyntec recommends installation of a vertical extent well in the center of the site (Hot Spot 2 area) post-remediation implementation.

groundwater↗

NASA airframe structural integrity program

NASA has initiated a research program with the long-term objective of supporting the aerospace industry in addressing issues related to the aging commercial transport fleet. The interdisciplinary program combines advanced fatigue crack growth prediction methodology with innovative nondestructive examination technology with the focus on multi-site damage (MSD) at riveted connections. A fracture mechanics evaluation of the concept of pressure proof testing the fuselage to screen for MSD has been completed. Also, a successful laboratory demonstration of the ability of the thermal flux method to detect disbonds at riveted lap splice joints has been conducted. All long-term program elements have been initiated and the plans for the methodology verification program are being coordinated with the airframe manufacturers.

Harris, Charles E.↗

Phase II and III Solid Waste Management Unit Assessment and Confirmatory Sampling Report for Per- and Polyfluorinated Alkyl Substances, Potential Release Location 237, Kennedy Space Center, Florida

Per- and polyfluoroalkyl substances (PFAS) Phase II and III Solid Waste Management Unit (SWMU) Assessment (SA) and Confirmatory Sampling (CS) were conducted at the John F. Kennedy Space Center (KSC), Potential Release Location (PRL) 237, located in Merritt Island, Brevard County, Florida for the National Aeronautics and Space Administration (NASA) under Contract 80KSC019D0010/80KSC019F0289. A Phase I SA and CS Report was previously submitted that identified 33 locations of concern (LOCs) at KSC associated with the storage, use, or release of materials containing PFAS. The objectives of the Phase II and III SA and CS were to: - Complete site and source characterization of identified LOCs; - Identify areas of potential concern (AOPCs) where past or present activities may have resulted in a release of PFAS to the environment; - Qualitatively characterize migration potential of released PFAS to environmental media (primarily soil, groundwater, surface water, and sediment); and - Identify potential receptors for exposure to PFAS-impacted environmental media. Surface water samples were collected from LOCs/AOPCs and locations on the KSC periphery during PFAS CS Phases I, II and III. Including duplicate samples, 143 environmental samples were analyzed for 14 PFAS compounds and 104 environmental samples were analyzed for 18 PFAS compounds. Ten of the analytes on the 14 compound list were detected at least once in surface water at KSC, with a wide range in magnitude of detections. The State of Florida has surface water screening levels (SWSLs) for perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) in surface water, both for human and ecological receptors. The human health screening levels are lower than the ecological ones and are used in this report. PFOA was not detected in surface water at concentrations exceeding the SWSL at any LOC or Area of Potential Concern (AOPC). PFOS was detected in surface water at concentrations exceeding the SWSL at 28 LOCs/AOPCs, plus 42 locations on the KSC periphery. The data suggest a wide distribution of PFAS, particularly PFOS, in surface water but the sources of surface water contamination are not yet adequately understood. Sediment samples were collected during Phases II and III but not Phase I. Including duplicate samples, 104 environmental samples were analyzed for 14 PFAS compounds and 10 environmental samples were analyzed for 18 PFAS compounds. Twelve compounds were detected in sediment at KSC, with a wide range in magnitude of detections. There are currently no screening levels or cleanup target levels (CTLs) for sediment. The need to delineate and further characterize PFAS in sediment will be evaluated for those sites that move forward into Site Assessment. Groundwater samples were collected via DPT from LOCs/AOPCs and locations on the KSC periphery during PFAS CS Phases I, II and III. Including duplicate samples, 812 environmental DPT groundwater samples were analyzed for 14 PFAS compounds and 247 environmental samples were analyzed for 18 PFAS compounds. Twelve of the 14 compounds were detected in groundwater at KSC, with a wide range in magnitude of detections. The State of Florida has provisional groundwater cleanup target levels (GCTLs) for PFOA, PFOS and the additive concentration of PFOA+PFOS. PFOA was detected in groundwater at concentrations exceeding its provisional GCTL at 16 LOCs/AOPCs, with no exceedances on the KSC periphery. PFOS was detected in groundwater at concentrations exceeding its provisional GCTL at 30 LOCs/AOPCs, plus two locations on the KSC periphery. PFOA+PFOS was detected in groundwater at concentrations exceeding the provisional GCTL at 31 LOCs/AOPCs, plus two locations on the KSC periphery. Soil samples were collected during Phases II and III but not Phase I. Including duplicate samples, 292 environmental samples were analyzed for 14 PFAS compounds and 80 environmental samples were analyzed for 18 PFAS compounds. Fourteen compounds were detected in soil at KSC, with a wide range in magnitude of detections. The State of Florida has provisional soil cleanup target levels (SCTLs) for PFOA and PFOS. There were no PFOA results above its provisional SCTL. There was one LOC with a result above the provisional SCTL for residential settings. Recommendations are presented for each LOC and AOPC.

PFAS↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 SWMU #041 Year 3 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 3 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 3 PMR extends from September 2021 through October 2022. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 3 reporting period was approximately 91%, with the majority of downtime attributed to system maintenance and repair. This is generally consistent with Year 1 and Year 2 runtimes of 85% and 92%, respectively. To help reduce downtime, an anti-scaling amendment, Redux 390, has been used to reduce scaling and help maintain system design parameters. Over nine million gallons of groundwater were treated during Year 3 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 97%. This PMR describes the activities that were performed during Year 3 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 3 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 3 plume conditions. Therefore, it can be assumed that the projected path remains valid for transition to MNA in one to two years of continuous HCS operation. The contents of this Year 3 PMR were presented during the February 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Replacement of MW0019 and VMP04 was also recommended, as well as additional direct-push technology sampling to further delineate the downgradient plume and confirm overall site-wide low-concentration plume boundaries. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

World-Wide Web Tools for Locating Planetary Images

The explosive growth of the World-Wide Web (WWW) in the past year has made it feasible to provide interactive graphical tools to assist scientists in locating planetary images. The highest available resolution images of any site of interest can be quickly found on a map or plot, and, if online, displayed immediately on nearly any computer equipped with a color screen, an Internet connection, and any of the free WWW browsers. The same tools may also be of interest to educators, students, and the general public. Image finding tools have been implemented covering most of the solar system: Earth, Mars, and the moons and planets imaged by Voyager. The Mars image-finder, which plots the footprints of all the high-resolution Viking Orbiter images and can be used to display any that are available online, also contains a complete scrollable atlas and hypertext gazetteer to help locating areas. The Earth image-finder is linked to thousands of Shuttle images stored at NASA/JSC, and displays them as red dots on a globe. The Voyager image-finder plots images as dots, by longitude and apparent target size, linked to online images. The locator (URL) for the top-level page is http: //ic-www.arc.nasa.gov/ic/projects/bayes-group/Atlas/. Through the efforts of the Planetary Data System and other organizations, hundreds of thousands of planetary images are now available on CD-ROM, and many of these have been made available on the WWW. However, locating images of a desired site is still problematic, in practice. For example, many scientists studying Mars use digital image maps, which are one third the resolution of Viking Orbiter survey images. When they douse Viking Orbiter images, they often work with photographically printed hardcopies, which lack the flexibility of digital images: magnification, contrast stretching, and other basic image-processing techniques offered by off-the-shelf software. From the perspective of someone working on an experimental image processing technique for super-resolution, the discovery that potential users are often not using the highest resolution already available, nor using conventional image processing techniques, was surprising. This motivated the present work.

Kanefsky, Bob↗

Waste Site Mapping

Old aircraft considered not restorable are melted down in on-site furnaces to reclaim the aluminum in their airframes. The process produces aluminum ingots and leaves a residue known as "dross." Because dross contains contaminants like lead silver cadmium and copper, Pima County, the dross dumping site, wanted to locate areas where dross had been dumped. Dr. Larry Lepley and Sandra L. Perry used the Landsat Thematic Mapper to screen for dross. A special two-step procedure was developed to separate the dross dumps (typically no larger than 50 meters across) from the desert background. The project has opened the door for similar applications.

Source record↗

Strategies Toward Lunar Dust Adhesion Mitigation

Recently, the NASA Space Technology Mission Directorate solicited feedback to prioritize shortfalls, which were defined as technology areas needed to enable future exploration missions. Lunar dust mitigation emerged as a critical area and is cross-cutting with many of the highest ranked shortfalls with passive dust mitigation technologies being directly ranked in the top 50. Hazards associated with lunar dust are ubiquitous across all aspects of long duration lunar surface missions, whether crewed or robotic, due to the abrasive, electrostatically charged, and chemically reactive properties of lunar dust. Compounding the issue, lunar dust moves across the lunar surface due to levitation, twilight craters, and plume-surface interactions, which can result in particle velocities exceeding 1 km/h. To address lunar dust challenges, NASA is developing active and passive adhesion mitigation technologies to address specific mission needs, including electrodynamic dust screens, piezoelectric materials, biomimetic engineered surfaces, among many others. Additionally, abrasion-resistant materials are being evaluated for applications for use near landing sites and in surface manipulation and excavation equipment. These approaches, as well as test methodologies both in the laboratory and on the lunar surface to evaluate technology efficacy, will be described.

Dust Mitigation↗

Metrics of Balance Control for Use in Screening Tests of Vestibular Function

Decrements in balance control have been documented in astronauts after space flight. Reliable measures of balance control are needed for use in postflight field tests at remote landing sites. Diffusion analysis (DA) is a statistical mechanical tool that shows the average difference of the dependent variable on varying time scales. These techniques have been shown to measure differences in open-loop and closed-loop postural control in astronauts and elderly subjects. The goal of this study was to investigate the reliability of these measures of balance control. Eleven subjects were tested using the Clinical Test of Sensory Interaction on Balance: the subject stood with feet together and arms crossed on a stable or compliant surface, with eyes open or closed and with or without head movements in the pitch or yaw plane. Subjects were instrumented with inertial motion sensors attached to their trunk segment. The DA curves for linear acceleration measures were characterized by linear fits measuring open- (Ds) and closed-loop (Dl) control, and their intersection point (X-int, Y-int). Ds and Y-int showed significant differences between the test conditions. Additionally, Ds was correlated with the root mean square (RMS) of the signal, indicating that RMS was dominated by open-loop events (< 0.5 seconds). The Y-int was found to be correlated with the average linear velocity of trunk movements. Thus DA measures could be applied to derive reliable metrics of balance stability during field tests.

Fiedler, Matthew↗

STK Integrated Message Production List Editor (SIMPLE) for CEO Operations

Late in fiscal year 2011, the Crew Earth Observations (CEO) team was tasked to upgrade and replace its mission planning and mission operations software systems, which were developed in the Space Shuttle era of the 1980s and 1990s. The impetuses for this change were the planned transition of all workstations to the Windows 7 64-bit operating system and the desire for more efficient and effective use of Satellite Tool Kit (STK) software required for reliable International Space Station (ISS) Earth location tracking. An additional requirement of this new system was the use of the same SQL database of CEO science sites from the SMMS, which was also being developed. STK Integrated Message Production List Editor (SIMPLE) is the essential, all-in-one tool now used by CEO staff to perform daily ISS mission planning to meet its requirement to acquire astronaut photography of specific sites on Earth. The sites are part of a managed, long-term database that has been defined and developed for scientific, educational, and public interest. SIMPLE's end product is a set of basic time and location data computed for an operator-selected set of targets that the ISS crew will be asked to photograph (photography is typically planned 12 to 36 hours out). The CEO operator uses SIMPLE to (a) specify a payload operations planning period; (b) acquire and validate the best available ephemeris data (vectors) for the ISS during the planning period; (c) ingest and display mission-specific site information from the CEO database; (d) identify and display potential current dynamic event targets as map features; (e) compute and display time and location information for each target; (f) screen and select targets based on known crew availability constraints, obliquity constraints, and real-time evaluated constraints to target visibility due to illumination (sun elevation) and atmospheric conditions (weather); and finally (g) incorporate basic, computed time and location information for each selected target into the daily CEO Target List product (message) for submission to ISS payload planning and integration teams for their review and approval prior to uplink. SIMPLE requires and uses the following resources: an ISS mission planning period Greenwich Mean Time start date/time and end date/time), the best available ISS mission ephemeris data (vectors) for that planning period, the STK software package configured for the ISS, and an ISS mission-specific subset of the CEO sites database. The primary advantages realized by the development and implementation of SIMPLE into the CEO payload operations support activity are a smooth transition to the Windows 7 operating system upon scheduled workstation refresh; streamlining of the input and verification of the current ISS ephemeris (vector data); seamless incorporation of selected contents of the SQL database of science sites; the ability to tag and display potential dynamic event opportunities on orbit track maps; simplification of the display and selection of encountered sites based on crew availability, illumination, obliquity, and weather constraints; the incorporation of high-quality mapping of the Earth with various satellite-based datasets for use in describing targets; and the ability to encapsulate and export the essential selected target elements in XML format for use by onboard Earth-location systems, such as Worldmap. SIMPLE is a carefully designed and crafted in-house software package that includes detailed help files for the user and meticulous internal documentation for future modifications. It was delivered in February 2012 for test and evaluation. Following acceptance, it was implemented for CEO mission operations support in May 2012.

Trenchard, Mike↗

Ground state energy of electrons in a static point-ion lattice

The ground state energy of a neutral collection of protons and electrons was investigated under the assumption that in the ground state configuration, static protons occupy the sites of a rigid Bravais lattice. The Wigner-Seitz method was used in conjunction with three postulated potentials: bare Coulomb, Thomas-Fermi screening, and screening by a uniform bare background charge. Within these approximations, the exact band-minimum energy and wave functions are derived. For each of the three potentials, the approximate minimum ground state energy per proton (relative to isolated electrons and protons) is, respectively, -1.078 Ry, -1.038 Ry, and -1.052 Ry. These three minima all fall at a density of about 0.60 gm/cu cm, which is thus an approximate lower bound on the density of metallic hydrogen at its transition pressure.

Styer, D. F.↗

New applications for phosphoric acid fuel cells

New applications for phosphoric acid fuel cells were identified and evaluated. Candidates considered included all possibilities except grid connected electric utility applications, on site total energy systems, industrial cogeneration, opportunistic use of waste hydrogen, space and military applications, and applications smaller than 10 kW. Applications identified were screened, with the most promising subjected to technical and economic evaluation using a fuel cell and conventional power system data base developed in the study. The most promising applications appear to be the underground mine locomotive and the railroad locomotive. Also interesting are power for robotic submersibles and Arctic villages. The mine locomotive is particularly attractive since it is expected that the fuel cell could command a very high price and still be competitive with the conventionally used battery system. The railroad locomotive's attractiveness results from the (smaller) premium price which the fuel cell could command over the conventional diesel electric system based on its superior fuel efficiency, and on the large size of this market and the accompanying opportunities for manufacturing economy.

Stickles, R. P.↗

Wilson Corners SWMU 001 2019-2020 Annual Long-Term Monitoring Report Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2019 and 2020 at Wilson Corners, Solid Waste Management Unit 001, at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. Sampling of these wells in 2020 was replaced with the direct push technology investigations in October 2020 and April 2021. The activities presented in this report include three field events: (1) December 2019 -groundwater gauging of 38 monitoring wells and sampling of 36 monitoring wells; (2) May 2020 - groundwater sampling of 7 monitoring wells; and (3) December 2020 - groundwater gauging of 49 monitoring wells and sampling of 43 monitoring wells. During the December 2019 and May 2020 events, monitoring wells were sampled using passive diffusion bags and were analyzed for a “full list” of volatile organic compounds (VOCs), including Freon 113. During the December 2020 event, the low flow sampling method was used, and samples were analyzed for a “select list” of VOCs, including Freon 113. The following conclusions can be made based on the 2019 and 2020 LTM results: •In December 2019 and December 2020, groundwater flow for the site was generally to the west with the individual zones only varying by occasional northerly and southerly components. This is generally consistent with historical observations at the site. •The GCTL plume continues to extend both horizontally and vertically beyond our current monitoring well network. •The vertical extent of VOCs was historically generally delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells WILC-MW0078 and WILC-MW0130 that were sampled during the 2019 and 2020 LTM indicate that groundwater VOC concentrations in both wells were greater than the GCTL. •Freon 113 was not detected above GCTLs during the 2019 and 2020 LTM events. Based on groundwater sampling activities performed during this reporting period, including recent DPT groundwater sampling conducted for the implementation of an air sparge system, the following recommendations are provided: •Install 10 new monitoring wells, which will be sampled along with 49 existing monitoring wells, to assist with delineation of the low concentration plume. The wells are listed inTable 4-1, and the proposed locations are presented on Figures4 -1 through 4-5. (Figures 4-1, 4-2, 4-3, and 4-5 also show updated plumes and proposed performance monitoring well locations. This information will be discussed and presented under a separate cover.) •Modify the annual LTM sampling plan as presented inTable 4-1. •Sampling for future events at the site will be conducted using low flow pumping methods. The next annual LTM sampling event is currently planned for December 2021. Please note the 10 new monitoring wells will not be installed before this event but will be installed as part of the upcoming IM construction and will be sampled during baseline sampling, along with the 49 existing monitoring wells. Following this sampling event, it is recommended that the Annual LTM be combined with the performance monitoring under the IM implementation, and LTM be temporarily discontinued. Objectives of the 2021 LTM are to: (i) evaluate groundwater gradient and flow direction by collecting depth to water measurements from LTM wells; (ii) continue monitoring the peripheral VOC trends in the northern, southern, and western portions of the site by monitoring existing wells and installing and monitoring new wells as recommended; and (iii) monitor select internal plume wells.

Jennifer Lynn Joyal↗

Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

Feiveson, Alan H.↗