Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Photovoltaic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Georectified polygon database of ground-mounted large-scale solar photovoltaic sites in the United States.

Over 4,400 large-scale solar photovoltaic (LSPV) facilities operate in the United States as of December 2021, representing more than 60 gigawatts of electric energy capacity. Of these, over 3,900 are ground-mounted LSPV facilities with capacities of 1 megawatt direct current (MW dc ) or more. Ground-mounted LSPV installations continue increasing, with more than 400 projects appearing online in 2021 alone; however, a comprehensive, publicly available georectified dataset including spatial footprints of these facilities is lacking. The United States Large-Scale Solar Photovoltaic Database (USPVDB) was developed to fill this gap. Using US Energy Information Administration (EIA) data, locations of 3,699 LSPV facilities were verified using high-resolution aerial imagery, polygons were digitized around panel arrays, and attributes were appended. Quality assurance and control were achieved via team peer review and comparison to other US PV datasets. Data are publicly available via an interactive web application and multiple downloadable formats, including: comma-separated value (CSV), application programming interface (API), and GIS shapefile and GeoJSON.

14 SOLAR ENERGY↗

Silicon solar photovoltaic power stations

Modular design of components and arrays, cost estimates for modules and support structures, and cost/performance analysis of a central solar photovoltaic power plant are discussed. Costs of collector/reflector arrays are judged the dominant element in the total capital investment. High-concentration solar tracking arrays are recommended as the most economic means for producing solar photovoltaic energy when solar cells costs are high ($500 per kW generated). Capital costs for power conditioning subsystem components are itemized and system busbar energy costs are discussed at length.

Chowaniec, C. R.↗

Do Agrivoltaics Improve Public Support for Solar Photovoltaic Development? Survey Says: Yes!

Agrivoltaic systems allow for the simultaneous production of solar-generated electricity and agriculture. As the climate change related impacts of conventional energy and food production intensify, finding strategies to increase the deployment of solar photovoltaic systems, preserve agricultural land, and minimize competing land uses is urgent. Given the proven technical, economic, and environmental advantages provided by agrivoltaic systems, increased proliferation is anticipated, which necessitates accounting for the nuances of community resistance to solar development on farmland. Minimizing siting conflict and addressing agricultural communities’ concerns will be key in promoting public support for agrivoltaics, as localized acceptance of solar is a critical determinant of project success. This survey study assessed if public support for solar development increases when energy and agricultural production are combined in an agrivoltaic system. Results show that 81.8% of respondents would be more likely to support solar development in their community if it combined the production of both energy and agriculture. This increase in support for solar given the agrivoltaic approach highlights a development strategy that can improve local social acceptance and the deployment rate of solar photovoltaics. Survey respondents prefer agrivoltaic projects that a) are designed to provide economic opportunities for farmers and the local community b) are located on private property or existing agricultural land c) do not threaten local interests and d) ensure fair distribution of economic benefits. Proactively identifying what the public perceives as opportunities and concerns related to agrivoltaic development can help improve the design, business model, and siting of systems in the U.S.

14 SOLAR ENERGY↗

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY↗

The Redox Flow System for solar photovoltaic energy storage

The interfacing of a Solar Photovoltaic System and a Redox Flow System for storage was workable. The Redox Flow System, which utilizes the oxidation-reduction capability of two redox couples, in this case iron and titanium, for its storage capacity, gave a relatively constant output regardless of solar activity so that a load could be run continually day and night utilizing the sun's energy. One portion of the system was connected to a bank of solar cells to electrochemically charge the solutions, while a separate part of the system was used to electrochemically discharge the stored energy.

Odonnell, P.↗

Solar photovoltaic power stations

The subsystems of a solar photovoltaic central power system are identified and the cost of major components are estimated. The central power system, which would have a peak power capability in the range of 50 to 1000 MW, utilizes two types of subsystems - a power conditioner and a solar array. Despite differences in costs of inverters, the overall cost of the total power conditioning subsystem is about the same for all approaches considered. A combination of two inverters operating from balanced dc buses as a pair of 6-pulse groups is recommended. A number of different solar cell modules and tracking array structures were analyzed. It is concluded that when solar cell costs are high (greater than $500/kW), high concentration modules are more cost effective than those with low concentration. Vertical-axis tracking is the most effective of the studied tracking modes. For less expensive solar cells (less than $400/kW), fixed tilt collector/reflector modules are more cost effective than those which track.

Chowaniec, C. R.↗

Solar Photovoltaics in Severe Weather: Cost Considerations for Storm Hardening PV Systems for Resilience

Solar photovoltaic (PV) power has many advantages as a resilient power source, including the ability to provide power after a natural disaster. While solar arrays often survive severe weather events, systems are occasionally compromised and left unable to provide power. For PV systems to act as resilient power providers, they must remain operational. Building a system that is more likely to survive a storm comes at a cost, though. Previous efforts have identified various system measures and practices that can increase the likelihood of a PV system surviving a severe weather event. But what is the cost premium for a storm hardened PV system? This report provides initial estimates for the up-front cost premiums for various methods of storm hardening PV systems.

14 SOLAR ENERGY↗

Maximum Outputs of Solar Photovoltaic Arrays

Report presents electrical data for solar photovoltaic arrays operating at different locations in United States. Data useful in designing power-conditioners for matching output of array to load.

Ross, R. G., Jr.↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Latest developments in the Advanced Photovoltaic Solar Array Program

In 1985, the Advanced Photovoltaic Solar Array (APSA) Program was established to demonstrate a producible array system with a specific power greater than 130 W/kg at a 10-kW (BOL) power level. The latest program phase completed fabrication and initial functional testing of a prototype wing representative of a full-scale 5-kW (BOL) wing (except truncated in length to about 1 kW), with weight characteristics that could meet the 130-W/kg (BOL) specific power goal using thin silicon solar cell modules and weight-efficient structural components. The wing configuration and key design details are reviewed, along with results from key component-level and wing-level tests. Projections for future enhancements that may be expected through the use of advanced solar cells and structural components are shown. Performance estimates are given for solar electric propulsion orbital transfer missions through the Van Allen radiation belts. The latest APSA program plans are presented.

Stella, Paul M.↗

Mission applications for advanced photovoltaic solar arrays

The suitability of the Advanced Photovoltaic Solar Array (APSA) for future space missions was examined by considering the impact on the spacecraft system in general. The lightweight flexible blanket array system was compared to rigid arrays and a radio-isotope thermoelectric generator (RTG) static power source for a wide range of assumed future earth orbiting and interplanetary mission applications. The study approach was to establish assessment criteria and a rating scheme, identify a reference mission set, perform the power system assessment for each mission, and develop conclusions and recommendations to guide future APSA technology development. The authors discuss the three selected power sources, the assessment criteria and rating definitions, and the reference missions. They present the assessment results in a convenient tabular format. It is concluded that the three power sources examined, APSA, conventional solar arrays, and RTGs, can be considered to complement each other. Each power technology has its own range of preferred applications.

Stella, Paul M.↗

Particle transport-driven flow dynamics and heat transfer modulation in solar photovoltaic modules: Implications on soiling

Wind-swept debris and excessive heating reduce solar photovoltaic efficiency and accelerate panel degradation. For many solar plants in open environments, particle deposition is well-understood to exacerbate efficiency losses by blocking useable light and insulating panel surfaces. However, little is known about particle behavior in multi-panel systems, where complex wakes dominate and alter trajectories. This study examines debris-laden flow within a scaled array of two model solar panels, observing convective cooling and focusing on turbulent inter-panel flow dynamics. Convection is compared between the first and second panels (P 1 and P 2 ) and for a single inflow velocity at four particle concentrations (Φ v ), including a neutrally buoyant particle (i.e. tracer) case and three water droplet cases. Tracers and Φ v > 0 concentrations show increased convective heat transfer for P 2 compared to P 1 , while inertial particle presence and increased concentration reduces this improvement from +170% to +90%. Particle image velocimetry surrounding P 2 reveals dampened inter-panel wake features for particle-laden flow compared to the tracer case, where diminished mean flow and mean kinetic energy breakdown are observed for the particles due to their inertia. Together, the reduction in comparative convection and dampened wake effects accompanying inertial particle concentration motivates further studies on coupled array physics in debris-filled flow.

14 SOLAR ENERGY↗

Lightweight Solar Photovoltaic Blankets

Lightweight, flexible sheets containing arrays of stacked solar photovoltaic cells developed to supply electric power aboard spacecraft. Solar batteries satisfying stringent requirements for operation in outer space also adaptable to terrestrial environment. Attractive for use as long-lived, portable photovoltaic power sources. Cells based on amorphous silicon which offers potential for order-of-magnitude increases in power per unit weight, power per unit volume, and endurance in presence of ionizing radiation.

Ceragioli, R.↗

Resilience Metrics for Solar Photovoltaics

This workshop presentation proposes the development of solar photovoltaic (PV) system resilience metrics and a methodology and framework for evaluation of PV resilience metrics. PV resilience metrics are needed to establish a consistent basis for reporting, evaluation, and data collection by industry, evaluate performance of PV systems that have been subject to natural hazards, correlating resilience to system attributes, and predicting resilience for any PV system. PV resilience metrics can guide improved system design, standards, and insurance coverage. Establishing consistent metrics can foster data collection on impacts of natural hazards on PV systems.

14 SOLAR ENERGY↗