Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 'BOOSTED FIREBALL' MODEL FOR STRUCTURED RELATIVISTIC JETS

We present a model for relativistic jets which generates a particular angular distribution of Lorentz factor and energy per solid angle. We consider a fireball with specific internal energy E/M launched with bulk Lorentz factor γ {sub B}. In its center-of-momentum frame the fireball expands isotropically, converting its internal energy into radially expanding flow with asymptotic Lorentz factor η{sub 0} ∼ E/M. In the lab frame the flow is beamed, expanding with Lorentz factor Γ = 2η{sub 0}γ {sub B} in the direction of its initial bulk motion and with characteristic opening angle θ{sub 0} ∼ 1/γ {sub B}. The flow is jet-like with Γθ{sub 0} ∼ 2η{sub 0} such that jets with Γ > 1/θ{sub 0} are naturally produced. The choice η{sub 0} ∼ γ {sub B} ∼ 10 yields a jet with Γ ∼ 200 on-axis and angular structure characterized by opening angle θ{sub 0} ∼ 0.1 of relevance for cosmological gamma-ray bursts (GRBs), while γ {sub B} ∼> 1 may be relevant for low-luminosity GRBs. The model produces a family of outflows, of relevance for different relativistic phenomena with structures completely determined by η{sub 0} and γ {sub B}. We calculate the energy per unit solid angle for the model and use it to compute light curves for comparison with the widely used top-hat model. The jet break in the boosted fireball light curve is greatly subdued when compared to the top-hat model because the edge of the jet is smoother than for a top-hat. This may explain missing jet breaks in afterglow light curves.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress on the National Solar Radiation Data Base (NSRDB): A new DNI computation

This study introduces a new technique to compute direct normal irradiance (DNI) for improving the National Solar Radiation Data Base (NSRDB). A finite-surface integration algorithm is developed to compute solar radiation in differential solid angles and efficiently infer its contribution to a surface perpendicular to the solar direction. A lookup table of cloud bi-directional transmittance distribution function (BTDF) is developed by use of the discrete ordinates radiative transfer (DISORT) model for possible solar and observing directions and various cloud optical and microphysical properties. In each solar incident direction, DNI is given by the cloud BTDFs from approximately 200 differential solid angles. The simulated DNI is calibrated and evaluated using surface observations at the National Renewable Energy Laboratory's (NREL's) Solar Energy Research Laboratory (SRRL) and the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) facility.

54 ENVIRONMENTAL SCIENCES↗

Fe-K LINE PROBING OF MATERIAL AROUND THE ACTIVE GALACTIC NUCLEUS CENTRAL ENGINE WITH SUZAKU

We systematically analyzed the high-quality Suzaku data of 88 Seyfert galaxies, about 31% of which are Compton-thick active galactic nuclei (AGNs). We obtained a clear relation between the absorption column density and the equivalent width (EW) of the 6.4 keV line above 10{sup 23} cm{sup -2}, suggesting a wide-ranging column density of 10{sup 23}-10{sup 24.5} cm{sup -2} with a similar solid and an Fe abundance of 0.7-1.3 solar for Seyfert 2 galaxies. The EWs of the 6.4 keV line for Seyfert 1 galaxies are typically 40-120 eV, suggesting the existence of Compton-thick matter like the torus with a column density of >10{sup 23} cm{sup -2} and a solid angle of (0.15-0.4) x 4{pi}, and no difference of neutral matter is visible between Seyfert 1 and 2 galaxies. An absorber with a lower column density of 10{sup 21}-10{sup 23} cm{sup -2} for Compton-thin Seyfert 2 galaxies is suggested to be not a torus but an interstellar medium. These constraints can be understood by the fact that the 6.4 keV line intensity ratio against the 10-50 keV flux is almost identical within a range of 2-3 in many Seyfert galaxies. Interestingly, objects exist with a low EW, 10-30 eV, of the 6.4 keV line, suggesting that those torus subtends only a small solid angle of <0.2 x 4{pi}. Thanks to high-quality data with a good signal-to-noise ratio and the accurate continuum determination of Suzaku, ionized Fe-K{alpha} emission or absorption lines are detected from several percent of AGNs. Considering the ionization state and EW, emitters and absorbers of ionized Fe-K lines can be explained by the same origin, and highly ionized matter is located at the broad-line region. The rapid increase in EW of the ionized Fe-K emission lines at N{sub H}>10{sup 23} cm{sup -2} indicates that the column density of the ionized material also increases together with that of the cold material. It is found that these features seem to change for brighter objects with more than several 10{sup 44} erg s{sup -1} such that the Fe-K line features become weak. This extends the previously known X-ray Baldwin effect on the neutral Fe-K{alpha} line to ionized emission or absorption lines. The luminosity dependence of these properties, regardless of the scatter of black hole mass by two orders of magnitudes, indicates that the ionized material is associated with the structure of the parent galaxy rather than the outflow from the nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nested Neutron Microfocusing Optics on SNAP

The high source intensity of the Spallation Neutron Source (SNS), together with efficient detectors and large detector solid angles, now makes possible neutron experiments with much smaller sample volumes than previously were practical. Nested Kirkpatrick–Baez supermirror optics provide a promising and efficient way to further decrease the useable neutron sample size by focusing polychromatic neutrons into microbeams. Because the optics are nondispersive, they are ideal for spallation sources and for polychromatic and wide bandpass experiments on reactor sources. Theoretical calculations indicate that nested mirrors can preserve source brilliance at the sample for small beams and for modest divergences that are appropriate for diffraction experiments. Although the flux intercepted by a sample can be similar with standard beam-guided approaches, the signal-to-background is much improved with small beams on small samples. Here we describe the design, calibration and performance of a nested neutron mirror pair for the Spallation Neutrons At Pressure (SNAP) beamline at the SNS. High-pressure neutron diffraction is but one example of a large class of neutron experiments that will benefit from spatially-resolved microdiffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing Nesting DXTRAN Spheres for Neutron Transport in Air

The deterministic transport sphere (DXTRAN sphere) is a technology that can be utilized in MCNP for improving sampling in the vicinity of a particular geometry, when the solid angle, between the source and particular geometry, is small. At a collision event, a DXTRAN particle is created and deterministically transported to the DXTRAN sphere, while the colliding particle (NONDXTRAN particle) continues transporting as if no DXTRAN event had occurred. Weight is balanced by killing the NONDXTRAN particle when traversing the DXTRAN sphere. If set up correctly, the DXTRAN particle placed on the DXTRAN sphere has a high probability of interacting with the geometry within the DXTRAN sphere. The Central Limit Theorem (CLT) states that the estimated mean approaches a normal distribution with known variance as the number of random samples grows sufficiently large. In reality the variance is seldom known and therefore must be estimated. In a Monte Carlo calculation, one must determine when the number of random samples is sufficiently large for the CLT to be satisfied. For the CLT to be satisfied, the first two moments (mean and variance) must exist. The second moment, the variance of a normal distribution is estimated. The slope test, which uses the largest 201 history scores of each tally fluctuation chart (TFC) bin fit to a Pareto function, is used to determine if the largest history scores decrease faster than 1/x{sup 3}. If the slope is less than 3, then enough histories have not yet been sampled such to meet the second moment existence requirement of the CLT. Usually, a slope of less than 3 indicates that the effects of high weight scores have not been satisfactorily sampled; such a consequence can also be manifested in examining trends in the 4. moment, the variance of the variance (VOV). For example, when examining the TFC, if the VOV is monotonically decreasing for a few sets of histories and then drastically increases for the next set of histories, chances are a rare high weight score, significantly greater than the average score, was encountered. As a result of the 1/R{sup 2} term, a point detector can achieve an extremely high weight, much greater than the average, as the distance from collision to point detector approaches zero. To remedy this difficulty, a 'radius of exclusion' is applied, where within the radius of exclusion 'the point detector estimate is assumed to be the average flux uniformly distributed'. A DXTRAN sphere can suffer from the same weight fluctuation as collisions in the vicinity of the DXTRAN sphere produce much larger weights than collisions happening far from the DXTRAN sphere. If the rare large weight put on the DXTRAN sphere then scores in a tally, there will be a significant increase in the VOV and the slope may drop below 3. To compliment that analysis, here we utilize an air composition and density that varies as a function of altitude, detailing the trials and tribulations of attempting to pass the 10 statistical checks for a variety of single and nested DXTRAN sphere approaches. The objective here is to illuminate important considerations for radiation transport problems with small solid angles in a scatter medium of few mean free paths (MFPs)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SEARCH FOR SOURCES OF HIGH-ENERGY NEUTRONS WITH FOUR YEARS OF DATA FROM THE ICETOP DETECTOR

IceTop is an air-shower array located on the Antarctic ice sheet at the geographic South Pole. IceTop can detect an astrophysical flux of neutrons from Galactic sources as an excess of cosmic-ray air showers arriving from the source direction. Neutrons are undeflected by the Galactic magnetic field and can typically travel 10 ( E /PeV) pc before decay. Two searches are performed using 4 yr of the IceTop data set to look for a statistically significant excess of events with energies above 10 PeV (10{sup 16} eV) arriving within a small solid angle. The all-sky search method covers from −90° to approximately −50° in declination. No significant excess is found. A targeted search is also performed, looking for significant correlation with candidate sources in different target sets. This search uses a higher-energy cut (100 PeV) since most target objects lie beyond 1 kpc. The target sets include pulsars with confirmed TeV energy photon fluxes and high-mass X-ray binaries. No significant correlation is found for any target set. Flux upper limits are determined for both searches, which can constrain Galactic neutron sources and production scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSCURING FRACTION OF ACTIVE GALACTIC NUCLEI: IMPLICATIONS FROM RADIATION-DRIVEN FOUNTAIN MODELS

Active galactic nuclei (AGNs) are believed to be obscured by an optical thick “torus” that covers a large fraction of solid angles for the nuclei. However, the physical origin of the tori and the differences in the tori among AGNs are not clear. In a previous paper based on three-dimensional radiation-hydorodynamic calculations, we proposed a physics-based mechanism for the obscuration, called “radiation-driven fountains,” in which the circulation of the gas driven by central radiation naturally forms a thick disk that partially obscures the nuclear emission. Here, we expand this mechanism and conduct a series of simulations to explore how obscuration depends on the properties of AGNs. We found that the obscuring fraction f{sub obs} for a given column density toward the AGNs changes depending on both the AGN luminosity and the black hole mass. In particular, f{sub obs} for N{sub H} ≥ 10{sup 22} cm{sup −2} increases from ∼0.2 to ∼0.6 as a function of the X-ray luminosity L{sub X} in the L{sub X} = 10{sup 42–44} erg s{sup −1} range, but f{sub obs} becomes small (∼0.4) above a luminosity (∼10{sup 45} erg s{sup −1}). The behaviors of f{sub obs} can be understood by a simple analytic model and provide insight into the redshift evolution of the obscuration. The simulations also show that for a given L{sub AGN}, f{sub obs} is always smaller (∼0.2–0.3) for a larger column density (N{sub H} ≥ 10{sup 23} cm{sup −2}). We also found cases that more than 70% of the solid angles can be covered by the fountain flows.

79 ASTRONOMY AND ASTROPHYSICS↗

Cross-section measurement and analysis for the {sup 149}Sm(n,alpha){sup 146}Nd reaction at 6.0 MeV

We have measured the {sup 149}Sm(n,alpha){sup 146}Nd cross section at 6.0 MeV to be 0.12+-0.018 mb. This is the first reported result for this cross section in the MeV region and so should be helpful for constraining nuclear data evaluations (which differ by a factor of 40 for this reaction at this energy) and for testing and improving nuclear models. The experiment was performed at the at the 4.5-MV Van de Graaff accelerator of Peking University. Neutrons were produced via the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target, and absolute neutron flux was determined with a small {sup 238}U fission chamber. Alpha particles were detected using a two-section gridded ionization chamber in which two large-area {sup 149}Sm{sub 2}O{sub 3} samples were placed back-to-back so that the cross section and forward/backward ratio were measured for nearly the entire 4pi solid angle. The data were compared to statistical-model predictions using the code talys. Good agreement between the measured and theoretical cross sections could be obtained with a small modification of the alpha-optical potential parameters from their default values in talys. However, we were not able to reproduce the measured forward/backward ratio. In addition, using the previously reported {sup 147}Sm(n,alpha){sup 144}Nd cross section at 6.0 MeV together with our new result, good agreement was found between the measured and predicted cross-section ratio for these two isotopes. Finally, none of the existing evaluated data libraries are in agreement with our new data to within the experimental uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MODELING THE NON-RECYCLED FERMI GAMMA-RAY PULSAR POPULATION

We use Fermi Gamma-ray Space Telescope detections and upper limits on non-recycled pulsars obtained from the Large Area Telescope (LAT) to constrain how the gamma-ray luminosity L{sub γ} depends on the period P and the period derivative P-dot . We use a Bayesian analysis to calculate a best-fit luminosity law, or dependence of L{sub γ} on P and P-dot , including different methods for modeling the beaming factor. An outer gap (OG) magnetosphere geometry provides the best-fit model, which is L{sub γ}∝P{sup -a} P-dot {sup b} where a = 1.36 ± 0.03 and b = 0.44 ± 0.02, similar to but not identical to the commonly assumed L{sub γ}∝√( E-dot )∝P{sup -1.5} P-dot {sup 0.5}. Given upper limits on gamma-ray fluxes of currently known radio pulsars and using the OG model, we find that about 92% of the radio-detected pulsars have gamma-ray beams that intersect our line of sight. By modeling the misalignment of radio and gamma-ray beams of these pulsars, we find an average gamma-ray beaming solid angle of about 3.7π for the OG model, assuming a uniform beam. Using LAT-measured diffuse fluxes, we place a 2σ upper limit on the average braking index and a 2σ lower limit on the average surface magnetic field strength of the pulsar population of 3.8 and 3.2 × 10{sup 10} G, respectively. We then predict the number of non-recycled pulsars detectable by the LAT based on our population model. Using the 2 yr sensitivity, we find that the LAT is capable of detecting emission from about 380 non-recycled pulsars, including 150 currently identified radio pulsars. Using the expected 5 yr sensitivity, about 620 non-recycled pulsars are detectable, including about 220 currently identified radio pulsars. We note that these predictions significantly depend on our model assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Emulation of anamorphic imaging on the SHARP extreme ultraviolet mask microscope

The SHARP high-numerical aperture actinic reticle review project is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. SHARP emulates the illumination and imaging conditions of current EUV lithography scanners and those several generations into the future. An anamorphic imaging optic with increased mask-side numerical aperture (NA) in the horizontal and increased demagnification in the vertical direction has been proposed in this paper to overcome limitations of current multilayer coatings and extend EUV lithography beyond 0.33 NA. Zoneplate lenses with an anamorphic 4×/8× NA of 0.55 are fabricated and installed in the SHARP microscope to emulate anamorphic imaging. SHARP’s Fourier synthesis illuminator with a range of angles exceeding the collected solid angle of the newly designed elliptical zoneplates can produce arbitrary angular source spectra matched to anamorphic imaging. A target with anamorphic dense features down to 50-nm critical dimension is fabricated using 40 nm of nickel as the absorber. In a demonstration experiment, anamorphic imaging at 0.55 4×/8× NA and 6 deg central ray angle (CRA) is compared with conventional imaging at 0.5 4× NA and 8 deg CRA. A significant contrast loss in horizontal features is observed in the conventional images. Finally, the anamorphic images show the same image quality in the horizontal and vertical directions.

36 MATERIALS SCIENCE↗

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers

A major challenge in soft X-ray spectroscopy is the efficient collection of the emitted X-rays by grazing-incidence mirrors. In this energy range, grazing-incidence mirrors are widely used as optics for the collection of light. The small angle of incidence necessarily limits the collection solid angle of soft X-ray spectrometers. We present a new mirror surface, a sagittal collimating diaboloid, that can both collect and focus light from a point source in an aberration-free manner. The usefulness of this optic in increasing throughput is demonstrated with a realistic example design of a moderate-sized (3 m) medium-resolution resonant inelastic X-ray scattering spectrometer.

36 MATERIALS SCIENCE↗

A unified heteronuclear decoupling strategy for magic-angle-spinning solid-state NMR spectroscopy

A unified strategy of two-pulse based heteronuclear decoupling for solid-state magic-angle spinning nuclear magnetic resonance is presented. The analysis presented here shows that different decoupling sequences like two-pulse phase-modulation (TPPM), X-inverse-X (XiX), and finite pulse refocused continuous wave (rCW{sup A}) are basically specific solutions of a more generalized decoupling scheme which incorporates the concept of time-modulation along with phase-modulation. A plethora of other good decoupling conditions apart from the standard, TPPM, XiX, and rCW{sup A} decoupling conditions are available from the unified decoupling approach. The importance of combined time- and phase-modulation in order to achieve the best decoupling conditions is delineated. The consequences of different indirect dipolar interactions arising from cross terms comprising of heteronuclear and homonuclear dipolar coupling terms and also those between heteronuclear dipolar coupling and chemical-shift anisotropy terms are presented in order to unfold the effects of anisotropic interactions under different decoupling conditions. Extensive numerical simulation results are corroborated with experiments on standard amino acids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting the full photoemission cone from laser-based ARPES experiments by leveraging deflector technology

Angle-resolved photoemission spectroscopy (ARPES) provides a direct access to the electronic band structure of solid and molecular systems. The momentum range accessible by this technique depends directly on the photon energy used, and low-photon-energy sources are insufficient to photoemit electrons over the full Brillouin zone of most quantum materials. In addition, while electrons are emitted over a 2π solid angle, conventional hemispherical analyzers only collect a small subset of those electrons. A previous work [Gauthier et al., Rev. Sci. Instrum. 92, 123907 (2021)] demonstrated that electrons emitted over a larger field-of-view can be acquired in one fixed configuration by accelerating them toward the analyzer with a bias voltage. Here, in this study, we extend this work by leveraging the deflector technology of novel ARPES hemispherical analyzers. We demonstrate the ability to detect all 2π photoemitted electrons in a fixed configuration for various materials, such as gold, cuprates, and transition-metal dichalcogenides. This approach is especially advantageous for time-resolved ARPES, as electron dynamics over a large momentum range can be accessed with identical measurement conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗