Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solute diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fingering flow patterns of thermosolutal convection in rectangular enclosures

Convection in rectangular enclosures with combined horizontal temperature and concentration gradients is studied. An electrochemical system is employed to impose the concentration gradients. Due to a large difference between the thermal and solutal diffusion rates the flow possesses double-diffusive characteristics. Very complex fingering flow patterns are observed around the two-phase interfaces. The main objective of the present work is to obtain more information on the flows near the two vertical phase interfaces under various parametric conditions. The fingering flows near the crystal could be one of the most important factors to cause the crystal imperfections. The ranges of the parameters studied are Sc (Schmidt number) = 2200 to 2400, Pr (Prandtl number) = 4.0 to 7.0, Gr sub T (Grashof number) = 2.50 x 10 to the 6th to 5.10 x 10 to the 7th power, Ar (aspect ratio) = 0.61 to 3.0, and N (buoyancy ratio) = 0.05 to 54.8.

Wang, L. W.↗

Flow-induced morphological instabilities due to temporally-modulated stagnation-point flow

The influence of periodically-modulated planar stagnation-point flow on the morphological stability of a directionally-solidifying interface is presently considered with a view to the effect of unsteady nonparallel flows on single-crystal growth. The modeling of the system assumes that the viscous boundary layer thickness is much greater than that of the solute boundary layer, and that the modulation frequency is much smaller than the strength of plane stagnation-point flow. The solidifying interface is either stabilized or destabilized depending on the ratio of the period of modulation to the solute-diffusion time.

Merchant, G. J.↗

Thermosolutal convection in high-aspect-ratio enclosures

Convection in high-aspect-ratio rectangular enclosures with combined horizontal temperature and concentration gradients is studied experimentally. An electrochemical system is employed to impose the concentration gradients. The solutal buoyancy force either opposes or augments the thermal buoyancy force. Due to a large difference between the thermal and solutal diffusion rates the flow possesses double-diffusive characteristics. Various complex flow patterns are observed with different experimental conditions.

Wang, L. W.↗

Stability of dendritic arrays

An approximate method for studying steady-state properties and linear stability of the dendritic arrays that are formed in directional solidification of alloys is proposed. This analysis is valid at high growth rates where the primary spacing between dendrites is larger than the velocity-dependent solutal diffusion length. A neutral stability boundary is computed and it is found that, in the situations where the results should be valid, the experimental data of Somboonsuk, et al. (1984) lie in the stable region, well away from the boundary.

Warren, James A.↗

Process modelling for Space Station experiments

Examined here is the sensitivity of a variety of space experiments to residual accelerations. In all the cases discussed the sensitivity is related to the dynamic response of a fluid. In some cases the sensitivity can be defined by the magnitude of the response of the velocity field. This response may involve motion of the fluid associated with internal density gradients, or the motion of a free liquid surface. For fluids with internal density gradients, the type of acceleration to which the experiment is sensitive will depend on whether buoyancy driven convection must be small in comparison to other types of fluid motion, or fluid motion must be suppressed or eliminated. In the latter case, the experiments are sensitive to steady and low frequency accelerations. For experiments such as the directional solidification of melts with two or more components, determination of the velocity response alone is insufficient to assess the sensitivity. The effect of the velocity on the composition and temperature field must be considered, particularly in the vicinity of the melt-crystal interface. As far as the response to transient disturbances is concerned, the sensitivity is determined by both the magnitude and frequency of the acceleration and the characteristic momentum and solute diffusion times. The microgravity environment, a numerical analysis of low gravity tolerance of the Bridgman-Stockbarger technique, and modeling crystal growth by physical vapor transport in closed ampoules are discussed.

Alexander, J. Iwan D.↗

Dendritic Growth Velocities in Microgravity

We measured dendritic tip velocities in pure succinonitrile (SCN) in microgravity. using a sequence of telemetered binary images sent to Earth from the Space Shuttle Columbia (STS-62). Growth velocities were measured as a function of the supercooling over the range 0.05-1.5 K. Microgravity observations show that buoyancy-induced convection alters the growth kinetics of SCN dendrites at supercooling as high as 1.3 K. Also, the dendrite velocity data measured under microgravity agree well with the Ivantsov paraboloidal diffusion solution when coupled to a scaling constant of sigma(sup *) = 0.0157.

Glicksman, M. E.↗

Selective Permeability of PVA Membranes. I: Radiation-Crosslinked Membranes

The water and salt transport properties of ionizing radiation crosslinked poly(vinyl alcohol) (PVA) membranes were investigated. The studied membranes showed high permeabilities and low selectivities for both water and salt. The results were found to be in accord with a modified solution-diffusion model for transport across the membranes, in which pressure-dependent permeability coefficients are employed.

Katz, Moshe G.↗

Martian Meteor Ionization Layers

Small interplanetary grains bombard Mars, like all the solar system planets, and, like all the planets with atmospheres, meteoric ion and atom layers form in the upper atmosphere. We have developed a comprehensive one-dimensional model of the Martian meteoric ionization layer including a full chemical scheme. A persistent layer of magnesium ions should exist around an altitude of 70 km. Unlike the terrestrial case, where the metallic ions are formed via charge-exchange with the ambient ions, Mg(+) in the Martian atmosphere is produced by photoionization. Nevertheless, the predicted metal layer peak densities for Earth and Mars are similar. Diffusion solutions, such as those presented here, should be a good approximation of the metallic ions in regions where the magnetic field is negligible and may provide a significant contribution to the nightside ionosphere. The low ultraviolet absorption of the Martian atmosphere may make Mars an excellent laboratory in which to study meteoric ablation. Resonance lines not seen in the spectra of terrestrial meteors may be visible to a surface observatory in the Martian highlands.

Grebowsky, J. M.↗

Numerical Analysis of Temperature Gradients and Interface Shape During Directional Solidification of Al and Al-Cu Alloy Under Microgravity Conditions

Numerical modeling was undertaken to analyze the influence of radial thermal gradient on solid/liquid interface shape and convection patterns during solidification of pure Al and Al-4 wt. % Cu alloy. Steady state calculations were performed for different gravity levels and orientations. Furthermore, transient modeling was undertaken to investigate effect of the solidification velocity. The furnace configuration used in this analysis is the proposed International Space Station Furnace. Results from a thermal model of the furnace core were used as initial boundary conditions for solidification modeling. The Solidification model was adopted from previous work and was based on the finite element code FIDAP. Thermocouple data and quenched interface shape from a pure Al sample flown on the Life Sciences and Microgravity Spacelab (LMS) mission, July 1996 was used for model validation. Good agreement was obtained between the predicted interface shape and that measured from the quenched LMS sample. It was found that the imposed temperature boundary condition must be sufficiently smooth for the heat fluxes in the model to be self-consistent. The model predicted that alloy sample Al-Cu is more sensitive to variations in the gravity level compared to pure Al. For Al-Cu alloy, solute diffusivity is approximately 10(exp 4) times smaller than thermal diffusivity of pure Al. Hence, in a microgravity environment the weak convection has no measurable effect on the heat fluxes, but is still strong enough to affect concentration distribution. Since the alloy melting temperature is determined by concentration the interface shape depends on the level of convection. This was found not to be the case for pure metal.

Bune, Andris V.↗

Membrane Separation Processes at Low Temperatures

The primary focus of Kennedy Space Center's gas separation activities has been for carbon dioxide, nitrogen, and argon used in oxygen production technologies for Martian in-situ resource utilization (ISRU) projects. Recently, these studies were expanded to include oxygen for regenerative life support systems. Since commercial membrane systems have been developed for separation of carbon dioxide, nitrogen, and oxygen, initially the studies focused on these membrane systems, but at lower operating temperatures and pressures. Current investigations art examining immobilized liquids and solid sorbents that have the potential for higher selectivity and lower operating temperatures. The gas separation studies reported here use hollow fiber membranes to separate carbon dioxide, nitrogen, and argon in the temperature range from 230 to 300 K. Four commercial membrane materials were used to obtain data at low feed and permeate pressures. These data were used with a commercial solution-diffusion modeling tool to design a system to prepare a buffer gas from the byproduct of a process to capture Martian carbon dioxide. The system was designed to operate, at 230 K with a production rate 0.1 sLpm; Feed composition 30% CO2, 44% N2, and 26% Ar; Feed pressure 104 kPa (780); and Permeate pressure 1 kPa (6 torr); Product concentration 600 ppm CO2. This new system was compared with a similar system designed to operate at ambient temperatures (298 K). The systems described above, along with data, test apparatus, and models are presented.

Parrish, Clyde↗

Reverse osmosis filtration for space mission wastewater: membrane properties and operating conditions

Reverse osmosis (RO) is a compact process that has potential for the removal of ionic and organic pollutants for recycling space mission wastewater. Seven candidate RO membranes were compared using a batch stirred cell to determine the membrane flux and the solute rejection for synthetic space mission wastewaters. Even though the urea molecule is larger than ions such as Na+, Cl-, and NH4+, the rejection of urea is lower. This indicates that the chemical interaction between solutes and the membrane is more important than the size exclusion effect. Low pressure reverse osmosis (LPRO) membranes appear to be most desirable because of their high permeate flux and rejection. Solute rejection is dependent on the shear rate, indicating the importance of concentration polarization. A simple transport model based on the solution-diffusion model incorporating concentration polarization is used to interpret the experimental results and predict rejection over a range of operating conditions. Grant numbers: NAG 9-1053.

Non-NASA Center↗

Rotating Reverse Osmosis for Wastewater Reuse

Our previous work established the concept of a low-pressure rotating reverse osmosis membrane system. The rotation of the cylindrical RO filter produces shear and Taylor vortices in the annulus of the device that decrease the concentration polarization and fouling commonly seen with conventional RO filtration techniques. A mathematical model based on the film theory and the solution-diffusion model agrees well with the experimental results obtained using this first generation prototype. However, based on the model, the filtrate flux and contaminant rejection depend strongly on the transmembrane pressure. Therefore, the goal of our current work is to improve the flux of the device by increasing the transmembrane pressure by a factor of 3 to 4. In addition, the rejections for a wider variety of inorganic and organic compounds typically found in space mission wastewater are measured.

Lueptow, Richard M.↗

Compositional Pathways and Capillary Effects during Early-stage Isothermal Precipitation in a Nondilute Ni-Al-Cr Alloy

For a Ni-5.2 Al-14.2 Cr at.% alloy with moderate solute supersaturations, the compositional pathways, as measured with atom-probe tomography, during early to later stage y'(LI2)-precipitation (R = 0.45-10 nm), aged at 873 K, are discussed in light of a multi-component coarsening model. Employing nondilute thermodynamics, detailed model analyses during quasistationary coarsening of the experimental data establish that the y/y' interfacial free-energy is 22- 23+/-7 mJ/sq m. Additionally, solute diffusivities are significantly slower than model estimates. Strong quantitative evidence indicates that an observed y'-supersaturation of Al results from the Gibbs-Thomson effect, providing the first experimental verification of this phenomenon. The Gibbs-Thomson relationship, for a ternary system, as well as differences in measured phase equilibria with CALPHAD assessments, are considered in great detail.

Sudbrack, Chantal K.↗

Pressure flux-split viscous solutions for subsonic diffusers

A method for predicting flow in diffusers with inlet swirl has been developed. Solutions of the pressure flux-split Reduced Navier Stokes (RNS) equations are obtained for flows in axisymmetric diffusers. Viscous-Inviscid interactions and flow fields with toroidal recirculation regions are efficiently captured. The computational model is verified by comparision with experimental data and other computations. The extreme sensitivity to grid, turbulent closure model and inlet profiles is discussed.

Pordal, H. S.↗

Measurement of diffusion coefficients from solution rates of bubbles

The rate of solution of a stationary bubble is limited by the diffusion of dissolved gas molecules away from the bubble surface. Diffusion coefficients computed from measured rates of solution give mean values higher than accepted literature values, with standard errors as high as 10% for a single observation. Better accuracy is achieved with sparingly soluble gases, small bubbles, and highly viscous liquids. Accuracy correlates with the Grashof number, indicating that free convection is the major source of error. Accuracy should, therefore, be greatly increased in a gravity-free environment. The fact that the bubble will need no support is an additional important advantage of Spacelab for this measurement.

Krieger, I. M.↗

Steady-state solutions of a diffusive energy-balance climate model and their stability

A diffusive energy-balance climate model, governed by a nonlinear parabolic partial differential equation, was studied. Three positive steady-state solutions of this equation are found; they correspond to three possible climates of our planet: an interglacial (nearly identical to the present climate), a glacial, and a completely ice-covered earth. Models similar to the main one are considered, and the number of their steady states was determined. All the models have albedo continuously varying with latitude and temperature, and entirely diffusive horizontal heat transfer. The stability under small perturbations of the main model's climates was investigated. A stability criterion is derived, and its application shows that the present climate and the deep freeze are stable, whereas the model's glacial is unstable. The dependence was examined of the number of steady states and of their stability on the average solar radiation.

Ghil, M.↗

Multigrid techniques for the solution of the passive scalar advection-diffusion equation

The solution of elliptic passive scalar advection-diffusion equations is required in the analysis of many turbulent flow and convective heat transfer problems. The accuracy of the solution may be affected by the presence of regions containing large gradients of the dependent variables. The multigrid concept of local grid refinement is a method for improving the accuracy of the calculations in these problems. In combination with the multilevel acceleration techniques, an accurate and efficient computational procedure is developed. In addition, a robust implementation of the QUICK finite-difference scheme is described. Calculations of a test problem are presented to quantitatively demonstrate the advantages of the multilevel-multigrid method.

Phillips, R. E.↗

Effects of particle drift on cosmic ray transport. II - Analytical solution to the modulation problem with no latitudinal diffusion

An analytical solution to a model of the modulation of galactic cosmic rays in the presence of particle drifts is presented and discussed. The solution assumes an energy-independent radial diffusion coefficient proportional to distance and no latitudinal diffusion, and includes energy-independent particle drift velocities similar to those expected in a Parker spiral magnetic field with an equatorial current sheet. The solutions clearly demonstrate the large effects of drifts on the modulated cosmic-ray intensity. For values of the radial diffusion coefficient and particle drift velocity which are plausible for 1-GV-rigidity protons, the logarithmic radial gradient in the inner solar system is reduced by more than a factor of 5 over the value calculated in the absence of drifts. It is found that even for much smaller values of particle drift velocity and radial diffusion coefficient, such as might be expected for protons with energies of the order of 10 MeV, the effects of the drifts can be substantial.

Isenberg, P. A.↗