Search NASA⌕ Search

SEARCH · Search NASA

Results for “Southeast Texas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): A Sub-Basin Framework for Future CO 2 Infrastructure Development (Task 4.1.a)

The “Southeast Regional CO 2 Utilization and Storage Acceleration Partnership” (SECARB-USA) project supports the U.S. Department of Energy (DOE) Office of Fossil Energy's (FE) mission to help the United States meet its need for secure, affordable, and environmentally sound fossil energy supplies by utilizing the advancements made since 2003 by the Regional Carbon Sequestration Partnership (RCSP) Initiative to continue to identify and address knowledge gaps. The SECARB-USA regional initiative encompasses the states of Alabama, Arkansas, Florida, Georgia, Louisiana, Mississippi, North Carolina, South Carolina, Tennessee, Virginia, and portions of Kentucky, Missouri, Oklahoma, Texas, and West Virginia as noted in Figure 1.1. The primary objective of the project is to identify and address regional onshore storage and transport challenges facing commercial deployment of carbon dioxide (CO 2 ) capture, utilization, and storage (CCUS) technologies.

42 ENGINEERING↗

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Risk Inventory for Commercial Storage Projects

The “Southeast Regional CO2 Utilization and Storage Acceleration Partnership” (SECARB USA) project supports the U.S. Department of Energy (DOE) Odice of Fossil Energy's (FE) mission to help the United States meet its need for secure, adordable, and environmentally sound fossil energy supplies by utilizing the advancements made since 2003 by the Regional Carbon Sequestration Partnership (RCSP) Initiative to continue to identify and address knowledge gaps. The SECARB-USA regional initiative encompasses the states of Alabama, Arkansas, Florida, Georgia, Louisiana, Mississippi, North Carolina, South Carolina, Tennessee, Virginia, and portions of Kentucky, Missouri, Oklahoma, Texas, and West Virginia as noted in Figure 1. The primary objective of the project is to identify and address regional onshore storage and transport challenges facing commercial deployment of carbon dioxide (CO2) capture, utilization, and storage (CCUS) technologies.

42 ENGINEERING↗

Shallow Aseismic Slip in the Delaware Basin Determined by Sentinel-1 InSAR

The Delaware Basin, Texas is currently a hot-spot of induced seismicity and ground deformation due to fluid extraction and injection associated with horizontal drilling techniques; however, the driving mechanism behind the seismicity and deformation remains under debate. Here, using vertical and east-west horizontal surface deformation measurements derived from Sentinel-1 interferometric synthetic aperture radar (InSAR), we show that the subsurface responds differently to oil and gas activity in the northern and southeastern portions of the basin. In the north, where there is little seismicity, deformation patterns display long-wavelengths and equidimensional patterns. In contrast, the southeast region hosts most of the seismicity and displays spatial deformation patterns with narrow linear features that strike parallel to the maximum principal horizontal stress and to trends in seismicity, suggesting movement along normal faults. We model a linear deformation feature using edge dislocations and show that the InSAR observations can be reproduced by slip on normal faults contained within the Delaware Mountain Group (DMG), the formation that hosts local wastewater injection and the majority of earthquakes. Our model consists of three parallel, high-angle normal faults, with two dipping toward one another in a graben structure. Slip magnitudes reach up to 25 cm and are spatially correlated with injection wells. Measured seismicity can only explain ~2% of the fault motion predicted by our fault model, suggesting that slip leading to the deformation is predominantly aseismic. We conclude that seismic and aseismic fault motion in the southeastern Delaware Basin is likely driven by wastewater injection near critically-stressed normal faults within the DMG.

58 GEOSCIENCES↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Projections of future climate for U.S. national assessments: past, present, future

Climate assessments consolidate our understanding of possible future climate conditions as represented by climate projections, which are largely based on the output of global climate models. Over the past 30 years, the scientific insights gained from climate projections have been refined through model structural improvements, emerging constraints on climate feedbacks, and increased computational efficiency. Within the same period, the process of assessing and evaluating information from climate projections has become more defined and targeted to inform users. As the size and audience of climate assessments has expanded, the framing, relevancy, and accessibility of projections has become increasingly important. This paper reviews the use of climate projections in national climate assessments (NCA) while highlighting challenges and opportunities that have emerged over time. Reflections and lessons learned address the continuous process to understand the broadening assessment audience and evolving user needs. Insights for future NCA development include (1) identifying benchmarks and standards for evaluating downscaled datasets, (2) expanding efforts to gather research gaps and user needs to inform how climate projections are presented in the assessment (3) providing practitioner guidance on the use, interpretation, and reporting of climate projections and uncertainty to better inform decision-making.

Assessment↗

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Initial Inventory of Non-Technical Challenges to CCUS Deployment

The “Southeast Regional CO 2 Utilization and Storage Acceleration Partnership” (SECARBUSA) project supports the U.S. Department of Energy (DOE) Office of Fossil Energy's (FE) mission to help the United States meet its need for secure, affordable, and environmentally sound fossil energy supplies by utilizing the advancements made by the current Regional Carbon Sequestration Partnership (RCSP) Initiative to continue to identify and address knowledge gaps. The primary project objective is to identify and address regional onshore storage and transport challenges facing commercial deployment of carbon dioxide (CO 2 ) capture, utilization, and storage (CCUS) technologies. The Research Partners and a selected industry network of experienced CCUS project developers and operators will coordinate their capabilities to accelerate CCUS deployment by achieving four primary research objectives: 1) address key technical challenges; 2) facilitate data collection, sharing and analysis; 3) assess transportation and distribution infrastructure; and 4) promote regional technology transfer and dissemination of knowledge. The SECARB-USA Region includes the states of Alabama, Arkansas, Florida, Georgia, Louisiana, Mississippi, North Carolina, South Carolina, Tennessee, and Virginia and portions of Kentucky, Missouri, Oklahoma, Texas, and West Virginia. Under subtask 5.2: Non-Technical Challenges to CCUS Deployment, the Southern States Energy Board (SSEB) will define and identify An Inventory of Non-Technical Challenges to CCUS Deployment. As an initial step, SSEB organized an Industry and Non-Governmental Organization (NGO) Working Group comprised of knowledgeable market participants to assist in the development of an initial list of non-technical challenges to CCUS development.

42 ENGINEERING↗

The persistent shadow of the supermassive black hole of M87. II. Model comparisons and theoretical interpretations

The Event Horizon Telescope (EHT) observation of M87∗ in 2018 has revealed a ring with a diameter that is consistent with the 2017 observation. The brightest part of the ring is shifted to the southwest from the southeast. In this paper, we provide theoretical interpretations for the multi-epoch EHT observations for M87∗ by comparing a new general relativistic magnetohydrodynamics model image library with the EHT observations for M87∗ in both 2017 and 2018. The model images include aligned and tilted accretion with parameterized thermal and nonthermal synchrotron emission properties. The 2018 observation again shows that the spin vector of the M87∗ supermassive black hole is pointed away from Earth. A shift of the brightest part of the ring during the multi-epoch observations can naturally be explained by the turbulent nature of black hole accretion, which is supported by the fact that the more turbulent retrograde models can explain the multi-epoch observations better than the prograde models. The EHT data are inconsistent with the tilted models in our model image library. Assuming that the black hole spin axis and its large-scale jet direction are roughly aligned, we expect the brightest part of the ring to be most commonly observed 90 deg clockwise from the forward jet. This prediction can be statistically tested through future observations.

79 ASTRONOMY AND ASTROPHYSICS↗