Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimental verification of Space Platform battery discharger design optimization

The detailed design of two candidate topologies for the Space Platform battery discharger, a four module boost converter (FMBC) and a voltage-fed push-pull autotransformer (VFPPAT), is presented. Each has unique problems. The FMBC requires careful design and analysis in order to obtain good dynamic performance. This is due to the presence of a right-half-plane (RHP) zero in the control-to-output transfer function. The VFPPAT presents a challenging power stage design in order to yield high efficiency and light component weight. The authors describe the design of each of these converters and compare their efficiency, weight, and dynamic characteristics.

Sable, Dan M.↗

Primary zinc-air batteries for space power

Prismatic HR and LC cells and batteries were built and tested, and they performed well with respect to the program goals of high capacity and high rate capability at specific energies. The HR batteries suffered reduced utilizations owing to dryout at the 2 and 3 A rates for the 50 C tests owing to the requirement for forced convection. The LC batteries suffered reduced utilizations under all conditions owing to the chimney effect at 1 G, although this effect would not occur at 0 G. An empirical model was developed which accurately predicted utilizations and average voltages for single cells, although thermal effects encountered during battery testing caused significant deviations, both positive and negative, from the model. Based on the encouraging results of the test program, we believe that the zinc-air primary battery of a flat, stackable configuration can serve as a high performance and safe power source for a range of space applications.

Bragg, Bobby J.↗

Hubble Space Telescope: Battery Capacity Trend Studies

Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. Capacity trend data is presented which suggests HST battery replacement is required in 2005-2007 or sooner.

Rao, M. Gopalakrishna↗

Sealed Silver-oxide Cadmium Batteries for Space Flight, 1960 - 1977

A technical summary of design, development, and test activities with Silver-Oxide Cadmium Batteries at the Goddard Space Flight Center since 1960 is given. The flight experience of over 15 missions has demonstrated the sealed Silver-Oxide Cadmium Battery to be a viable energy storage device for missions requiring ultra-clean magnetic environment.

Hennigan, Thomas J.↗

Evaluation of nickel-hydrogen battery for space application

Results of electrical space qualification tests of nickel-hydrogen battery type HR 23S are presented. The results obtained for the nickel-cadmium battery type VO 23S are similar except that the voltage level and the charge conservation characteristics vary significantly. The electrical and thermal characteristics permit predictions of the following optimal applications: charge coefficient in the order of 1.3 to 1.4 at 20C; charge current density higher than C/10 at 20C; discharge current density from C/10 to C/3 at 20C; maximum discharge temperature: OC; storage temperature: -20C.

Billard, J. M.↗

Hubble Space Telescope battery background

The following topics are presented in viewgraph form and include the following: the MSFC Hubble Space Telescope (HST) Nickel-Hydrogen Battery Contract; HST battery design requirements; HST nickel-hydrogen battery development; HST nickel-hydrogen battery module; HST NiH2 battery module hardware; pressure vessel design; HST NiH2 cell design; offset non-opposing vs. rabbit ear cell; HST NiH2 specified capacity; HST NiH2 battery design; and HST NiH2 module design.

Standlee, Dan↗

Enabling Mission Flexibility to Battery Driven Deep Space Endeavors With Generalized Battery-Health-Monitoring Using Physics-Based and Data-Driven Reduced-Order Models

The needs and requirements for an electrochemical energy storage for deep space exploration is well explored. It is often understood that different mission sites and environmental conditions require different battery chemistries or technologies. Additionally, various engineering solutions are deployed to overcome specific chemical challenges. One often overlooked need is the “health” monitoring of an electrochemical storage system. The term generalized health monitoring, as envisioned in this work, refers to the monitoring of various aspects such as electrode health, electrolyte health, reaction pathway health, cooling system health, sensor health, and BMS health [1]. Generalized health monitoring allows mission leads, engineers, and scientists to incorporate flexibility in mission designs, make on-the-fly mission changes, and extend the duration of science missions. Moreover, it enables automation and data-driven decision-making without compromising safety and performance. Recently, our group developed a hierarchy of thermal reduced-order models (TROM) by combining a physics-based modeling approach and data-driven model reduction techniques applied to flight data [2]. The resulting TROMs were found to be not only accurate but also identifiable from the flight data. Consequently, the coefficient of variance of the model parameters is small over the course of hundreds of flights, allowing for monitoring the parameter evolution trajectories as the battery ages and degrades. These parameters constitute the metrics of the generalized health of a battery. Monitoring their evolution allows such models to be used for anomaly detection and prognostics, improving early detection of abnormal behavior and thus enabling timely maintenance, longer battery life, and enhanced battery safety. For this presentation, the practicality of the thermal model will be validated on a pack of 14cells under various topology configurations such as 1S14P, 2P7S, 7S2P, and 1P14S. It is well known that manufacturing and non-uniform aging lead to variability in the performance of a cell, which is exacerbated by cell balancing during active load. Additionally, in extreme scenarios, the paramount objective is to complete the mission, regardless of the stresses on the battery. Topology-induced balancing issues further stress the battery. The goal of this study is to determine if the noise (identifiability) in the reduced-order thermal model parameters is sensitive to topology, cell spacing, cooling strategy, and manufacturing or age variability. The variability in cells is considered by assuming a multimodal distribution for microscopic parameters of a cell (such as porosity, tortuosity, reaction kinetics, volumetric thermal conductivity, and volumetric heat capacity). The compounded effect of manufacturing variability, topological selection, cooling strategies, and cell balancing ages each cell in a battery differently. The study aims to clarify whether the challenge in extracting maximum information depends on the minimum number of sensors or models used for data extraction.

Automation↗

A high power lithium thionyl chloride battery for space applications

A high power, 28 V, 330 A h, active lithium thionyl chloride battery has been developed for use as main and payload power sources on an expendable launch vehicle. Nine prismatic cells, along with the required electrical components and a built-in heater system, are efficiently packaged resulting in significant weight savings over presently used silver-zinc batteries. The high rate capability is achieved by designing the cells with a large electrochemical surface area and impregnating an electrocatalyst, polymeric phthalocyanine, into the carbon cathodes. Passivation effects are reduced with the addition of sulfur dioxide into the thionyl chloride electrolyte solution. The results of conducting a detailed thermal analysis are utilized to establish the heater design parameters and the thermal insulation requirements of the battery. An analysis of cell internal pressure and vent characteristics clearly illustrates the margins of safety under different operating conditions. Performance of fresh cells is discussed using polarization scan and discharge data at different rates and temperatures. Self-discharge rate is estimated based upon test results on cells after storage. Results of testing a complete prototype battery are described.

Shah, Pinakin M.↗

Exploring the Model Design Space for Battery Health Management

Battery Health Management (BHM) is a core enabling technology for the success and widespread adoption of the emerging electric vehicles of today. Although battery chemistries have been studied in detail in literature, an accurate run-time battery life prediction algorithm has eluded us. Current reliability-based techniques are insufficient to manage the use of such batteries when they are an active power source with frequently varying loads in uncertain environments. The amount of usable charge of a battery for a given discharge profile is not only dependent on the starting state-of-charge (SOC), but also other factors like battery health and the discharge or load profile imposed. This paper presents a Particle Filter (PF) based BHM framework with plug-and-play modules for battery models and uncertainty management. The batteries are modeled at three different levels of granularity with associated uncertainty distributions, encoding the basic electrochemical processes of a Lithium-polymer battery. The effects of different choices in the model design space are explored in the context of prediction performance in an electric unmanned aerial vehicle (UAV) application with emulated flight profiles.

Saha, Bhaskar↗

The design and application of nickel-cadmium batteries in space

This paper describes the considerations given to selection of 20 and 50 A h nickel-cadmium cells and batteries for NASA/Goddard's Solar Max and Landsat D missions. Results of cell and battery manufacturer testing and improvements in design required by NASA standard specifications are shown. Operation of three batteries in parallel using a single voltage limit/current taper charge control system is described along with suggestions for optimizing life and uniformity. The results of three years of in-orbit operation is presented.

Halpert, G.↗

Crewed Space Vehicle Battery Safety Requirements

This requirements document is applicable to all batteries on crewed spacecraft, including vehicle, payload, and crew equipment batteries. It defines the specific provisions required to design a battery that is safe for ground personnel and crew members to handle and/or operate during all applicable phases of crewed missions, safe for use in the enclosed environment of a crewed space vehicle, and safe for use in launch vehicles, as well as in unpressurized spaces adjacent to the habitable portion of a space vehicle. The required provisions encompass hazard controls, design evaluation, and verification. The extent of the hazard controls and verification required depends on the applicability and credibility of the hazard to the specific battery design and applicable missions under review. Evaluation of the design and verification program results shall be completed prior to certification for flight and ground operations. This requirements document is geared toward the designers of battery systems to be used in crewed vehicles, crew equipment, crew suits, or batteries to be used in crewed vehicle systems and payloads (or experiments). This requirements document also applies to ground handling and testing of flight batteries. Specific design and verification requirements for a battery are dependent upon the battery chemistry, capacity, complexity, charging, environment, and application. The variety of battery chemistries available, combined with the variety of battery-powered applications, results in each battery application having specific, unique requirements pertinent to the specific battery application. However, there are basic requirements for all battery designs and applications, which are listed in section 4. Section 5 includes a description of hazards and controls and also includes requirements.

Jeevarajan, Judith A.↗

Aluminum-oxygen batteries for space applications

An aluminum oxygen fuel cell is under development. Several highly efficient cell designs were constructed and tested. Air cathodes catalyzed with cobalt tetramethoxy porphorin have demonstrated more than 2000 cycles in intermittant use conditions. Aluminum alloys have operated at 4.2 kWH/kg at 200 mA/sq cm. A novel separator device, an impeller fluidizer was coupled with the battery to remove the solid hydrargillite discharge product. A 60 kW, 720 kWH battery system is projected to weigh about 2200 lbs., for an energy density of 327 WH lb.

Niksa, Marilyn J.↗

Driving Design Factors for Safe, High Power Batteries for Space Applications

Final Document is attached. New design features and test methods are in development at NASA to take advantage of the newest high power and energy dense commercial Li-ion cell designs and to achieve passively thermal runaway (TR) propagation resistant (PPR) designs for manned missions requiring high power/voltage. The goal is to minimize the parasitic mass and volume of the battery components; thus reaching a balance between high battery specific power (W/kg) and energy (Wh/kg) as well as power (W/L) and energy density (Wh/L). Current 18650 cell designs achieve greater than 275 Wh/kg, greater than 725 Wh/L, but present high risks of side wall breaching during TR which can defeat many other safety features resulting in nearly immediate TR propagation. This work seeks to better understand the phenomena of cell side wall breaches and to determine the effectiveness of promising battery design features for achieving safe, high performing battery designs for high voltage/power applications.

Li-ion↗

Li-Ion Batteries for Space Applications: High Specific Energy and Wide-Operating Temperature

Compared to the conventional Ni-Co oxides (with or without AI additions), the NMC (1/3:1/3:1/3) cathode provides marginal improvement in specific capacity. However, some of the formulations based on the solid solutions of layered Li2Mn03 and LiM02 (M = Mn0.5Ni0.5} have shown capacities as high as 250 mAh/g, combined with high cell voltages (4.5 V) and with the likelihood of enhanced thermal stability. Multi-component electrolytes with low EC-proportions and selected co-solvents provide significant improvement in the low temperature performance, down to -60 C, combined with the non-flammable attribute from the co-solvents. The NMC cathode shows good compatibility with the carbonate-based low temperature electrolytes. Impressive performances have been realized at low temperatures of <= 30 C. Electrolytes with high salt concentration and high EC content fare well at room temperatures, while the formulations with low EC content and low salt concentration are preferred at low temperatures. DPA studies reveal increased SEI growth on the electrodes, especially anode, upon irradiation. Performance of low temperature electrolytes in prototype cells corroborate the findings from laboratory cells.

storage↗

Secondary lithium batteries for space applications

Secondary lithium cells which use a LiAsF6-2-Me-THF electrolyte and a TiS2 intercalatable cathode exhibit encouraging cycle life at ambient temperature. Electrochemical and surface analytical studies indicate that the electrolyte is unstable in the presence of metallic lithium, leading to the formation of a lithium passivating film composed of lithium arsenic oxyfluorides and lithium fluorsilicates. The lithium cyclability remains as the most important problem to solve. Different electrolyte solvents, such as sulfolane, exhibit promising characteristics but lead to new compatibility problems with the other cell component materials.

Carter, B.↗

New Techniques for Thermo-electrochemical Analysis of Lithium-ion Batteries for Space Applications

The overall goal of this study was achieved: Replicated the numerical assessment performed by Chen et. al. (2005). Displayed the ability of Thermal Desktop to be coupled with thermo-electrochemical analysis techniques. such that the local heat generated on the cells is a function of the model itself using logic blocks and arrays. Differences in the TD temperature vs. depth of discharge profiles and Chen's was most likely due to differences in two primary areas: Contact regions and conductance values. Differences in density and specific heat values. center dot The model results are highly dependent on the accuracy of the material properties with respect to the multiple layers of an individual cell.

Walker, William↗