SESOP: Program for solar-energy heating-systems analysis

Space heating and cooling loads are calculated for each building based on outside environment, desired inside conditions, building construction and geometry, domestic power usage, occupancy rate, and occupant metabolic rate. Loads are summed to determine requirements of central and alternative utility systems.

Source record↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

SPRITE - A computer code for the optimization of space based heat pipe radiator systems

An integrated analytical tool has been developed for use in designing optimized space-based heat pipe radiator systems. This code, SPRITE-1, incorporates the thermal, structural, and reliability aspects of the radiator into a single framework from which a physically consistent design can be obtained. A parametric study of the integral heat pipe panel radiator was performed using SPRITE-1, and a preliminary minimum mass design was obtained. The radiator design is summarized, and the mass minimization method and results are presented.

Buksa, John J.↗

Study of outgassing and decomposition of space shuttle heat protection tiles, fillers and adhesive

The purpose of this project was to determine the chemicals desorbing from the space shuttle heat protection tiles. The original protocol for this project involved direct insertion probe mass spectrometry (DIPMS) analysis of the outgassing products from the tiles. However, this method proved unsatisfactory due to the large number of compounds desorbing from the tiles. A purge and trap technique was then employed to collect and separate the chemicals desorbing from the tiles. The maximum temperature in this analysis was 180 C which is the gas chromatograph fused silica capillary column's temperature limit. The desorption was also carried out at atmospheric pressure with helium as the purge gas. A description of the modified protocol is given. All compounds are tentatively identified.

Proctor, B. L.↗

Results of a flight experiment on the catalytic efficiency of the Space Shuttle heat shield

An experiment was performed on the second Space Shuttle flight to verify data from arc-heated wind-tunnel tests indicating that the thermal protection tiles used on the Shuttle's surface are noncatalytic to the recombination of dissociated air. The experiment indicates that the tiles are indeed noncatalytic, and explains the lower than expected temperatures observed in the first two Shuttle flights. The data are reasonably well predicted with computations, using a chemically reactive boundary-layer code. The experimental setup and the computational analysis are described.

Rakich, J. V.↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

Thermal analysis of M551 experiment for materials processing in space

Heat flow in a disc due to moving heat generated by electron beam was studied analytically. Computer programs based on the finite-element method were developed for the analysis of two and three dimensional mathematical models. The limited experimental data were compared with the analytical results, and factors which had influence on heat flow in the disc were studied. The computer programs were modified to consider the effects of metal melting and solidification as well as radiation. Temperature dependency of thermophysical properties was also considered.

Muraki, T.↗

Space Station heat pipe advanced radiator element (SHARE) flight test results and analysis

The SHARE experiment, which consisted of a single 51 ft long by 1 ft wide prototypical Space Station heat pipe radiator panel, was flown aboard STS-29 in March 1989. Several problems were uncovered during the flight which limited performance. Extensive post-flight analysis has revealed that the manifold connecting the evaporator and condenser sections did not prime properly in 0-g, and that a mismatch in hydraulic diameters between the evaporator and condenser caused large bubbles to be present in the liquid channel at startup. These bubbles subsequently became trapped at the evaporator entrance, halting liquid flow and causing premature dryout of the evaporator wall grooves. The experiment did demonstrate heat pipe transport capability of up to 1572 W with near isothermality in both the evaporator and condenser for short periods of time.

Kosson, Robert↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Solar-heated bank-Marks Mississippi

Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.

Source record↗

Space shuttle: Heat transfer rate measurements of North American Rockwell orbiter (161B) at nominal Mach number of 8

Plots and tables which determine detailed heat transfer distributions on phase B space shuttle configurations are presented. A thin-skinned thermocouple was used to measure the reentry events of the delta wing orbiter. Data was obtained at a nominal Mach number of 8 and free stream Reynolds numbers ranging from 0.83 x 10 to the 6th power to 3.76 x 10 to the 6th power per foot. Angle of attack was varied from -5 to 50 degrees.

Warmbrod, J. D.↗

Time and Space Resolved Heat Transfer Measurements Under Nucleate Bubbles with Constant Heat Flux Boundary Conditions

Investigations into single bubble pool boiling phenomena are often complicated by the difficulties in obtaining time and space resolved information in the bubble region. This usually occurs because the heaters and diagnostics used to measure heat transfer data are often on the order of, or larger than, the bubble characteristic length or region of influence. This has contributed to the development of many different and sometimes contradictory models of pool boiling phenomena and dominant heat transfer mechanisms. Recent investigations by Yaddanapyddi and Kim and Demiray and Kim have obtained time and space resolved heat transfer information at the bubble/heater interface under constant temperature conditions using a novel micro-heater array (10x10 array, each heater 100 microns on a side) that is semi-transparent and doubles as a measurement sensor. By using active feedback to maintain a state of constant temperature at the heater surface, they showed that the area of influence of bubbles generated in FC-72 was much smaller than predicted by standard models and that micro-conduction/micro-convection due to re-wetting dominated heat transfer effects. This study seeks to expand on the previous work by making time and space resolved measurements under bubbles nucleating on a micro-heater array operated under constant heat flux conditions. In the planned investigation, wall temperature measurements made under a single bubble nucleation site will be synchronized with high-speed video to allow analysis of the bubble energy removal from the wall.

Myers, Jerry G.↗

Solar energy system performance evaluation report for IBM System 4 at Clinton, Mississippi

The IBM System 4 Solar Energy System is described and evaluated. The system was designed to provide 35 percent of the space heating and 63 percent of the domestic hot water preheating for a single family residence located within the United States. The system consists of 259 square feet of flat plate air collectors, a rock thermal storage containing 5 1/2 ton of rock, heat exchangers, blowers, a 52 gallon preheat tank, controls, and associated plumbing. In general, the performance of the system did not meet design expectations, since the overall design solar fraction was 48 percent and the measured value was 32 percent. Although the measured space heating solar fraction at 32 percent did agree favorably with the design space heating solar fraction at 35 percent, the hot water measured solar fraction at 33 percent did not agree favorably with the design hot water solar fraction of 63 percent. In particular collector array air leakage, dust covered collectors, abnormal hot water demand, and the preheat tank by pass valve problem are main reasons for the lower performance.

Source record↗