Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Voyager 1 and 2 Observations of a Change in the Nature of Magnetic Fluctuations in the VLISM with Increasing Distance from the Heliopause

Voyager 2 (V2) crossed the heliopause at 119.0 au on 2018 day 309, after which it observed compressive (longitudinal) magnetic field fluctuations along the average magnetic field direction in the very local interstellar medium (VLISM) at distances from 119.00 to 121.48 au and latitudes 32.°2 to 32.°4 S in heliographic inertial coordinates from 2018 day 309 to 2019 day 230. This result confirms the observations of longitudinal magnetic field fluctuations by Voyager 1 (V1) between 124.14 and 128.71 au at 34.°6N (∼2–7 au upwind of the heliopause) from 2013 day 133 to 2014 day 235. V1 crossed the heliopause at 121.58 au and 34.°5N on 2012 day 238. It came as a surprise to find it seemed that V1 observed transverse (Alfvénic) fluctuations of B between 131.40 and 135.98 au at latitude 34.°6–34.°7N (∼10–14 au upwind of the heliopause) from 2015 day 145 to 2016 day 248. The most recent V1 observations show the possible presence of transverse fluctuations of B in the VLISM from 141.44 to 146.01 au at 34.°7–34.°8N (∼20–24 au from the heliopause) between 2018 day 75 and 2019 day 178. Together, these observations show that longitudinal (compressive) magnetic field fluctuations are transmitted through the heliopause from the heliosheath into the VLISM, and are then converted into transverse (Alfvénic) fluctuations at ∼130 au (∼8 au from the heliopause) that are observed out at 146 au (∼24 au from the heliopause).

79 ASTRONOMY AND ASTROPHYSICS↗

A Foreshock Model for Interstellar Shocks of Solar Origin: Voyager 1 and 2 Observations

The Voyager 1 (V1) and Voyager 2 (V2) spacecraft were launched in 1977 on a mission to explore the outer planets and reach the heliopause, the boundary between the hot solar plasma and the relatively cool interstellar plasma. V1 reached the heliopause on 2012 August 25, at 121.6 au, and V2 reached the heliopause on 2018 November 5, at 119.0 au. One of their remarkable discoveries was the detection of shocks propagating into the interstellar plasma from energetic solar events. These shocks are typically preceded by electron plasma oscillations excited by electron beams streaming along interstellar magnetic field lines ahead of the shocks. The frequencies of the plasma oscillations have now provided radial electron density profiles in the outer heliosphere and in the interstellar medium to radial distances of more than 145 au. The oscillations are typically preceded by bursts of high-energy ∼5–100 MeV electrons. These electron bursts are interpreted as being due to the reflection (and acceleration) of cosmic-ray electrons by the shock at the time the shock first contacts the magnetic field line that passes through the spacecraft. Relative timing between the cosmic rays reflected by the shock and the onset of the plasma oscillations allow us, for the first time, to estimate the energy, ∼20–100 eV, of the electron beams responsible for the plasma oscillations. These observations are combined into a self-consistent model called the foreshock model that describes the interaction of shocks of solar origin with the interstellar plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

First Leptophobic Dark Matter Search from the Coherent–CAPTAIN-Mills Liquid Argon Detector

We report the first results of a search for leptophobic dark matter (DM) from the Coherent–CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9 × 10 20 protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM’s first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005 + 16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m V B =m χ = 2.1, DM masses within the range 9 MeV ≲ m χ ≲ 50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM’s upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methods for Measuring and Computing the Reference Temperature in Newton’s Law of Cooling for External Flows

Newton’s law of cooling requires a reference temperature (𝑇 𝑟𝑒𝑓 ) to define the heat-transfer coefficient (ℎ). For external flows with multiple temperatures in the freestream, obtaining 𝑇 𝑟𝑒𝑓 is a challenge. One widely used method, referred to as the adiabatic-wall (AW) method, obtains 𝑇 𝑟𝑒𝑓 by requiring the surface of the solid exposed to convective heat transfer to be adiabatic. Another widely used method, referred to as the linear-extrapolation (LE) method, obtains 𝑇 𝑟𝑒𝑓 by measuring/computing the heat flux ($𝑞^{′′}_𝑠$) on the solid surface at two different surface temperatures (𝑇 𝑠 ) and then linearly extrapolating to $𝑞^{′′}_𝑠$ = 0. A third recently developed method, referred to as the state-space (SS) method, obtains 𝑇 𝑟𝑒𝑓 by probing the temperature space between the highest and lowest in the flow to account for the effects of 𝑇 𝑠 or $𝑞^{′′}_𝑠$ on 𝑇 𝑟𝑒𝑓 . This study examines the foundation and accuracy of these methods via a test problem involving film cooling of a flat plate where $𝑞^{′′}_𝑠$ switches signs on the plate’s surface. Results obtained show that only the SS method could guarantee a unique and physically meaningful 𝑇 𝑟𝑒𝑓 where 𝑇 𝑠 =𝑇 𝑟𝑒𝑓 on a nonadiabatic surface $𝑞^{′′}_𝑠$ = 0. The AW and LE methods both assume 𝑇 𝑟𝑒𝑓 to be independent of 𝑇 𝑠 , which the SS method shows to be incorrect. Though this study also showed the adiabatic-wall temperature, 𝑇 𝐴𝑊 , to be a good approximation of 𝑇 𝑟𝑒𝑓 (<10% relative error), huge errors can occur in ℎ about the solid surface where |𝑇 𝑠 −𝑇 𝐴𝑊 | is near zero because where 𝑇 𝑠 =𝑇 𝐴𝑊 , $𝑞^{′′}_𝑠$ ≠ 0.

Newton's law of cooling↗

Flavor-changing light bosons with accidental longevity

We consider a model with a complex scalar field that couples to (e, μ) or (μ, τ) within the “longevity” window: [|m l 1 – m l 2 |, m l 1 + m l 2 ] in which l 1 and l 2 are the two different charged leptons. Within such a mass window, even a relatively large coupling (e.g. of the size commensurate with the current accuracy/discrepancy in the muon g – 2 experiment) leads to long lifetimes and macroscopic propagation distance between production and decay points. We propose to exploit several existing neutrino experiments and one future experiment to probe the parameter space of this model. For the μ – e sector, we exploit the muonium decay branching ratio and the production and decay sequence at the LSND experiment, excluding the parametric region suggested by g μ – 2 anomaly. For the τ – μ sector, we analyze three main production mechanisms of scalars at beam dump experiments: the Drell-Yan process, the heavy meson decay, and the muon scattering. We explore the constraints from the past CHARM and NuTeV experiments, and evaluate sensitivity for the proposed beam dump experiment, SHiP. The latter can thoroughly probe the parameter space relevant for the g μ – 2 anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Straight lightning as a signature of macroscopic dark matter

Macroscopic dark matter (macros) is a broad class of alternative candidates to particle dark matter. These candidates would transfer energy to matter primarily through elastic scattering. A sufficiently large macro passing through the atmosphere would produce a straight channel of ionized plasma. If the cross-section of the macro is σx ≳ 6 × 10 –9 cm 2 , then under atmospheric conditions conducive to lightning (eg. a thunderstorm) the plasma channel would be sufficient to seed a lightning strike with a single leader. This is entirely unlike ordinary bolt lightning in which a long sequence of hundreds or thousands of few-meter-long leaders are strung together. This macro-induced lightning would be extremely straight, and thus highly distinctive. Neither wind shear nor magnetohydrodynamic instabilities would markedly spoil its straightness. The only photographically documented case of a straight lightning bolt is probably not straight enough to have been macro-induced. We estimate the region of macro parameter space that could be probed by a search for straight lightning from the number of thunderstorms happening on Earth at any time. In conclusion, we also estimate the parameter space that can be probed by carefully monitoring Jupiter, e.g. using the Hubble Space Telescope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing gravity with the DES-CMASS sample and BOSS spectroscopy

ABSTRACT The DES-CMASS sample (DMASS) is designed to optimally combine the weak lensing measurements from the Dark Energy Survey (DES) and redshift-space distortions (RSD) probed by the CMASS galaxy sample from the Baryonic Oscillation Spectroscopic Survey. In this paper, we demonstrate the feasibility of adopting DMASS as the equivalent of CMASS for a joint analysis of DES and BOSS in the framework of modified gravity. We utilize the angular clustering of the DMASS galaxies, cosmic shear of the DES metacalibration sources, and cross-correlation of the two as data vectors. By jointly fitting the combination of the data with the RSD measurements from the CMASS sample and Planck data, we obtain the constraints on modified gravity parameters $\mu _0=-0.37^{+0.47}_{-0.45}$ and $\Sigma _0=0.078^{+0.078}_{-0.082}$. Our constraints of modified gravity with DMASS are tighter than those with the DES Year 1 redMaGiC sample with the same external data sets by 29 per cent for μ0 and 21 per cent for Σ0, and comparable to the published results of the DES Year 1 modified gravity analysis despite this work using fewer external data sets. This improvement is mainly because the galaxy bias parameter is shared and more tightly constrained by both CMASS and DMASS, effectively breaking the degeneracy between the galaxy bias and other cosmological parameters. Such an approach to optimally combine photometric and spectroscopic surveys using a photometric sample equivalent to a spectroscopic sample can be applied to combining future surveys having a limited overlap such as DESI and LSST.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constrained Bayesian optimization of criticality experiments

The design of criticality experiments is typically an iterative process that employs a Monte Carlo transport code. The goal is to find a design that optimizes some variable, like the sensitivity of a response to a cross section, while simultaneously ensuring criticality. The high fidelity of the Monte Carlo code is a great asset, but it makes exploring the design space computationally expensive. Herein, we present how a constrained Bayesian optimization algorithm can be used to efficiently design a criticality experiment. It uses Gaussian processes as a surrogate model to probe the design space and to reduce the number of code executions that are needed to find the optimum. Furthermore, we demonstrate constrained Bayesian optimization with a Pu-239/polyethylene solution system and a TEX experiment that is designed for criticality safety validation of a nuclear waste model at the Hanford Site. For both systems, a global optimum was found within 75 Monte Carlo simulations.

42 ENGINEERING↗

Constrained Bayesian Optimization of Criticality Experiments [Slides]

The design of criticality experiments is typically an iterative process that employs a Monte Carlo transport code. The goal is to find a design that optimizes some variable, like the sensitivity of a response to a cross section, while simultaneously ensuring criticality. The high fidelity of the Monte Carlo code is a great asset, but it makes exploring the design space computationally expensive. Herein, we present how a constrained Bayesian optimization algorithm can be used to efficiently design a criticality experiment. It uses Gaussian processes as a surrogate model to probe the design space and to reduce the number of code executions that are needed to find the optimum. We demonstrate constrained Bayesian optimization with a Pu-239/polyethylene solution system and a TEX experiment that is designed for criticality safety validation of a nuclear waste model at the Hanford Site. For both systems, a global optimum was found within 75 Monte Carlo simulations.

42 ENGINEERING↗

Constrained Bayesian Optimization of Criticality Experiments at LLNL [Slides]

The design of criticality experiments is typically an iterative process that employs a Monte Carlo transport code. The goal is to find a design that optimizes some variable, like the sensitivity of a response to a cross section, while simultaneously ensuring criticality. The high fidelity of the Monte Carlo code is a great asset, but it makes exploring the design space computationally expensive. Herein, we present how a constrained Bayesian optimization algorithm can be used to efficiently design a criticality experiment. It uses Gaussian processes as a surrogate model to probe the design space and to reduce the number of code executions that are needed to find the optimum. We demonstrate constrained Bayesian optimization with a Pu-239/polyethylene solution system and a TEX experiment that is designed for critical ity safety validation of a nuclear waste model at the Hanford Site. For both systems, a global optimum was found within 75 Monte Carlo simulations.

42 ENGINEERING↗

Quantitative Analysis of the Semiconductor–Electrolyte Interface Using Cyclic Voltammetry Measurements

Small changes in the chemical potential at a semiconductor interface can result in dramatic changes to the space-charge layer that underpins applications in the electronic and photovoltaic industries as well as in photoelectrochemical cells for fuel production. There has hence been great interest in techniques that directly probe the space-charge layer, yet many fail at the semiconductor–electrolyte interface due to the potential drop in the electric double-layer region of the electrolyte. This article demonstrates that photovoltages, obtained from straightforward cyclic voltammetry measurements, provide an experimental and quantitative approach for characterizing the semiconductor–electrolyte interface. Key parameters accessible through this approach include the flat-band potential ( E fb ), the fraction of the total potential that drops across the space-charge layer (γ sc ) and the electric double layer, as well as the surface recombination lifetime (τ s ). Here, we report photovoltage measurements for p -type Si(111) photoelectrodes in contact with electrolytes containing redox-active species with a range of known reduction potentials that exceed the 1.1 eV bandgap. In tetrabutylammonium [NBu 4 ] + electrolyte, the flat-band potential determined for hydrogen-terminated ( p -Si–H), methyl-terminated ( p -Si–CH 3 ), and chemically oxidized ( p -Si–cSiO x ) surfaces were −0.02, −0.31, and 0.30 V vs Fc +/0 , respectively, agreeing well with expected shifts arising from surface dipole modifications. The quantitative analysis also reveals that 67% of the applied bias drops across the space-charge layer for p -Si–H, 73% for p -Si–CH 3 , and only 44% for p -Si–cSiO x . The remaining potential drop is attributed to the interfacial surface layer, which consists of a molecular dipole or oxide overlayer, and the Helmholtz layer within the electrolyte. When the larger [NBu 4 ] + electrolyte was replaced with Li + , the flat-band position showed minimal changes, but the fraction of the potential drop across the space-charge layer increased significantly, consistent with the small cation altering the structure of the electric double layer.

electrolytes↗

Upper bound on Parity breaking scale for doublet WIMP dark matter

A bstract We consider weakly interacting massive particle (WIMP) dark matter in a Parity solution to the strong CP problem. The WIMP phenomenology can be drastically affected by the presence of Parity partners of the WIMP and electroweak gauge bosons. We focus on a Parity extension of SU(2) L -doublet fermion dark matter, identify the viable parameter space, and derive the predictions of the theory. We find that the Parity symmetry breaking scale is bounded from above, with the bound given by 25–60 TeV, depending on whether or not dark matter and its Parity partner coannihilate with each other. The High-Luminosity Large Hadron Collider, future colliders, and direct and indirect detection experiments can probe the parameter space further, with correlated signal rates.

Baldwin, Matthew J. [University of Chicago; Univer↗

Upper Bound on Parity Breaking Scale for Doublet WIMP Dark Matter

We consider weakly interacting massive particle (WIMP) dark matter in a Parity solution to the strong CP problem. The WIMP phenomenology can be drastically affected by the presence of Parity partners of the WIMP and electroweak gauge bosons. We focus on a Parity extension of $SU(2)_L$-doublet fermion dark matter, identify the viable parameter space, and derive the predictions of the theory. We find that the Parity symmetry breaking scale is bounded from above, with the bound given by $25-60$ TeV, depending on whether or not dark matter and its Parity partner coannihilate with each other. The High-Luminosity Large Hadron Collider, future colliders, and direct and indirect detection experiments can probe the parameter space further, with correlated signal rates.

Baldwin, Matthew J. [Chicago U.; Chicago U., KICP]↗

Closed-loop optimization of fast-charging protocols for batteries with machine learning

Simultaneously optimizing many design parameters in time-consuming experiments causes bottlenecks in a broad range of scientific and engineering disciplines. One such example is process and control optimization for lithium-ion batteries during materials selection, cell manufacturing and operation. A typical objective is to maximize battery lifetime; however, conducting even a single experiment to evaluate lifetime can take months to years. Furthermore, both large parameter spaces and high sampling variability necessitate a large number of experiments. As such, the key challenge is to reduce both the number and the duration of the experiments required. Here we develop and demonstrate a machine learning methodology to efficiently optimize a parameter space specifying the current and voltage profiles of six-step, ten-minute fast-charging protocols for maximizing battery cycle life, which can alleviate range anxiety for electric-vehicle users. We combine two key elements to reduce the optimization cost: an early-prediction model, which reduces the time per experiment by predicting the final cycle life using data from the first few cycles, and a Bayesian optimization algorithm, which reduces the number of experiments by balancing exploration and exploitation to efficiently probe the parameter space of charging protocols. Using this methodology, we rapidly identify high-cycle-life charging protocols among 224 candidates in 16 days (compared with over 500 days using exhaustive search without early prediction), and subsequently validate the accuracy and efficiency of our optimization approach. Our closed-loop methodology automatically incorporates feedback from past experiments to inform future decisions and can be generalized to other applications in battery design and, more broadly, other scientific domains that involve time-intensive experiments and multi-dimensional design spaces.

25 ENERGY STORAGE↗

Electromagnetic power of lightning superbolts from Earth to space

Lightning superbolts are the most powerful and rare lightning events with intense optical emission, first identified from space. Superbolt events occurred in 2010-2018 could be localized by extracting the high energy tail of the lightning stroke signals measured by the very low frequency ground stations of the World-Wide Lightning Location Network. Here, we report electromagnetic observations of superbolts from space using Van Allen Probes satellite measurements, and ground measurements, and with two events measured both from ground and space. From burst-triggered measurements, we compute electric and magnetic power spectral density for very low frequency waves driven by superbolts, both on Earth and transmitted into space, demonstrating that superbolts transmit 10-1000 times more powerful very low frequency waves into space than typical strokes and revealing that their extreme nature is observed in space. We find several properties of superbolts that notably differ from most lightning flashes; a more symmetric first ground-wave peak due to a longer rise time, larger peak current, weaker decay of electromagnetic power density in space with distance, and a power mostly confined in the very low frequency range. Their signal is absent in space during day times and is received with a long-time delay on the Van Allen Probes. These results have implications for our understanding of lightning and superbolts, for ionosphere-magnetosphere wave transmission, wave propagation in space, and remote sensing of extreme events.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing exotic charged Higgs decays in the Type-II 2HDM through top rich signal at a future 100 TeV pp collider

The exotic decay modes of non-Standard Model Higgs bosons are efficient in probing the hierarchical Two Higgs Doublet Models (2HDM). In particular, the decay mode H ± → HW ± serves as a powerful channel in searching for charged Higgses. In this paper, we analyze the reach for H ± → HW ± → $t\bar{t}W$ at a 100 TeV pp collider, and show that it extends the reach of the previously studied ττW final states once above the top threshold. Top tagging technique is used, in combination with a boosted decision tree classifier. At the low tan β region, almost the entire hierarchical Type-II 2HDM parameter space can be probed via the combination of all exotic decay channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sterile neutrino dark matter and leptogenesis in Left-Right Higgs Parity

The standard model Higgs quartic coupling vanishes at (10 9 – 10 13 ) GeV. We study SU(2) L × SU(2) R × U(1) B–L theories that incorporate the Higgs Parity mechanism, where this becomes the scale of Left-Right symmetry breaking, $v_R$. Furthermore, these theories solve the strong CP problem and predict three right-handed neutrinos. We introduce cosmologies where SU(2) R × U(1) B–L gauge interactions produce right-handed neutrinos via the freeze-out or freeze-in mechanisms. In both cases, we find the parameter space where the lightest right-handed neutrino is dark matter and the decay of a heavier one creates the baryon asymmetry of the universe via leptogenesis. A theory of flavor is constructed that naturally accounts for the lightness and stability of the right-handed neutrino dark matter, while maintaining sufficient baryon asymmetry. The dark matter abundance and successful natural leptogenesis require vR to be in the range (10 10 – 10 13 ) GeV for freeze-out, in remarkable agreement with the scale where the Higgs quartic coupling vanishes, whereas freeze-in requires $v_R$ ≳ 109 GeV. The allowed parameter space can be probed by the warmness of dark matter, precise determinations of the top quark mass and QCD coupling by future colliders and lattice computations, and measurement of the neutrino mass hierarchy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗