JPL spacecraft sterilization technology program - A status report
Facility description and procedures for heat and ethylene oxide sterilization of spacecraft instrumentation, components, and materials
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Facility description and procedures for heat and ethylene oxide sterilization of spacecraft instrumentation, components, and materials
The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.
Compatibility and shielding analysis of science instruments in spacecraft containing radioisotope thermoelectric generator
This paper deals only with the pointing error contribution due to errors in predicting the impact location and describes the acquisition of optical data of the Impactor and associated errors using the flyby instruments; the algorithm for autonomously computing a pointing correction; the expected uncertainty in predicting the impact location; the uncertainty in the flyby pointing correction, and hence the improvement in performance.
The application of force limiting to spacecraft equipment is illustrated with the random vibration test of the Cassini radio plasma wave subsystem antenna instrument. Force limiting was used in the vibration tests of most of the instruments and major equipment on the Cassini spacecraft, as well as in the vibration test of the complete flight spacecraft. Force limits for the Cassini instruments and complete spacecraft vibration tests were developed using a semi-empirical method which only requires the acceleration specification and the data from a low level pre-test in order to determine the mass of the test item.
Spacecraft instrument module configurations which support an earth resource data gathering mission using a thematic mapper sensor were examined. The differences in size of these two experiments necessitated the development of two different spacecraft configurations. Following the selection of the best-suited configurations, a validation phase of design, analysis and modelling was conducted to verify feasibility. The chosen designs were then used to formulate definition for a systems weight, a cost range for fabrication and interface requirements for the thematic mapper (TM).
List of satellites and space probes with descriptions of scientific instrumentation
The accuracy of both onboard and ground attitude determination can be significantly enhanced by calibrating spacecraft attitude instruments (sensors) after launch. Although attitude sensors are accurately calibrated before launch, the stresses of launch and the space environment inevitably cause changes in sensor parameters. During the mission, these parameters may continue to drift requiring repeated on-orbit calibrations. The goal of attitude sensor calibration is to reduce the systematic errors in the measurement models. There are two stages at which systematic errors may enter. The first occurs in the conversion of sensor output into an observation vector in the sensor frame. The second occurs in the transformation of the vector from the sensor frame to the spacecraft attitude reference frame. This paper presents postlaunch alignment and transfer function calibration of the attitude sensors for the Compton Gamma Ray Observatory (GRO), the Upper Atmosphere Research Satellite (UARS), and the Extreme Ultraviolet Explorer (EUVE).
On-orbit Molecular Contamination occurs when materials outgas and deposit onto very sensitive interior surfaces of the spacecraft and instruments. The current solution, Molecular Adsorber Pucks, has disadvantages, which are reviewed. A new innovative solution, Molecular Adsorber Coating (MAC), is currently being formulated, optimized, and tested. It is a sprayable alternative composed of Zeolite-based coating with adsorbing properties.
A thermophysical model has been developed to generate asteroid Bennu surface temperature maps for OSIRIS-REx spacecraft and instrument thermal design and analyses at the Critical Design Review (CDR). Two-dimensional temperature maps for worst hot and worst cold cases are used in Thermal Desktop to assure adequate thermal design margins. To minimize the complexity of the Bennu geometry in Thermal Desktop, it is modeled as a sphere instead of the radar shape. The post-CDR updated thermal inertia and a modified approach show that the new surface temperature predictions are more benign. Therefore the CDR Bennu surface temperature predictions are conservative.
The powerpoint presentation details the key factors that lead to the design for the Cosmic Background Explorer's (COBE) spacecraft and instrument thermal design.
During the radiative cooler cool-down phase of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument thermal vacuum test #3, the coldest temperature that the Cold Focal Plane Array (CFPA) achieved was 89.5 K. The cold stage/CFPA temperature decreased from 315 K to 89.5 K in 80 hours. In the spacecraft and instrument integrated thermal vacuum test, the cold stage/CFPA temperature decreased from 315 K to 86.9 K in 80 hours, and was still decreasing at a rate of 0.08 K/hr when the cool-down was terminated. The cool-down was faster, and a colder CFPA temperature was obtained. In flight, the cooler cool- down was even faster, and colder. The cold stage/CFPA temperature decreased from 315 K to 89.7 K in 33 hours, and was still decreasing at a rate of 1 K/hr when cool- down was terminated at 89.7 K. The factors that affected the ETM+ cooler cool-down are the radiation heat sink temperature for the cold stage and intermediate stage, parasitic radiation heat load to the cooler, parasitic conduction heat load to the cooler, and cooler outgas time preceding cooler cool-down.
A review is given which surveys the variety of faults and failures which have occurred in space due both to the effects of single, energetic nuclear particles, as well as effects due to the accumulated ionizing dose or the fluence of nuclear particles. The review covers a variety of problems with sensors, electronics, instruments and spacecraft from several countries.
During the past three years, force limiting has been used in the vibrations tests of most of the instruments and major equipment on the CASSINI spacecraft, as well as in the axial random vibration test of the complete flight spacecraft in November of 1996.
The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.
This paper describes development of a radiation tolerant, low power, reconfigurable avionics module aimed at meeting the avionics needs of the JPL Micro-Inspector spacecraft. This module represents a complete avionics system, consisting of two PowerPC 405 CPUs embedded within a reconfigurable FPGA fabric of over 8 Million logic gates, 64MB of EDAC protected Flash storage and 128MB of EDAC protected DDR SDRAM or SDRAM memories, along with FPGA SEU mitigation logic, and all necessary power conversion. Processor SEU mitigation is achieved by running the two processors in a lock-step and compare configuration. All of these building blocks are integrated into a double sided circuit board that takes as little as 6 square inches of board space. This module can be embedded into a user system as part of a bigger circuit assembly or as a self contained module. This module is being developed as part of a JPL led Micro-Inspector Program, funded by NASA ESMD aimed at producing a 10Kg micro spacecraft.
During the past three years, force limiting has been used in the vibration tests of most of the insturments and mojor equipment on the Cassini spacecraft, as well as in the vibration test of the complete flight spacecraft in November of 1996.
During the past three years, force limiting has been used in the vibration tests of most of the insturments and major equipment on the Cassini spacecraft, as well as in the vibration test of the complete flight spacecraft in November of 1996.