Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral Tailoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A 3-Channel Algorithm for Retrieving Spatially and Temporally Continuous Cloud Properties Across Different Geostationary Satellite Imagers

Cloud property retrieval algorithms for passive satellite imagers are generally designed to take advantage of all the useful spectral information available for a particular satellite. This strategy optimizes accuracy and reduces misidentification and retrieval biases, particularly for modern satellites with many spectral channels. However, the application of dissimilar algorithms tailored for different satellite sensor scan present a problem within the climate data record (CDR). Algorithm inconsistencies can introduce artificial trends in the CDR that are tied to instrument changes rather than physical changes, especially when older satellites with limited spectral information are included. The NASA CERES (Clouds and the Earth’s Radiant Energy System) data record provides global cloud property retrievals across 23 years and more than 25 satellites. With the goal of producing a spatially and temporally continuous record of cloud properties, the CERES cloud working group has developed algorithms that use only 3 channels that are common to most geostationary satellite imagers: 0.65, 3.9, and 10.8 μm.

Sarah Bedka↗

Measurement of rolling friction by a damped oscillator

An experimental method for measuring rolling friction is proposed. The method is mechanically simple. It is based on an oscillator in a uniform magnetic field and does not involve any mechanical forces except for the measured friction. The measured pickup voltage is Fourier analyzed and yields the friction spectral response. The proposed experiment is not tailored for a particular case. Instead, various modes of operation, suitable to different experimental conditions, are discussed.

Dayan, M.↗

Pyroelectric detectors

The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

Haller, Eugene E.↗

The NANOGrav 11 yr data set: Evolution of Gravitational-wave Background Statistics

An ensemble of inspiraling supermassive black hole binaries should produce a stochastic background of very low frequency gravitational waves. This stochastic background is predicted to be a power law, with a gravitational-wave strain spectral index of −2/3, and it should be detectable by a network of precisely timed millisecond pulsars, widely distributed on the sky. This paper reports a new “time slicing” analysis of the 11 yr data release from the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) using 34 millisecond pulsars. Methods to flag potential “false-positive” signatures are developed, including techniques to identify responsible pulsars. Mitigation strategies are then presented. We demonstrate how an incorrect noise model can lead to spurious signals, and we show how independently modeling noise across 30 Fourier components, spanning NANOGrav’s frequency range, effectively diagnoses and absorbs the excess power in gravitational-wave searches. This results in a nominal, and expected, progression of our gravitational-wave statistics. Additionally, we show that the first interstellar medium event in PSR J1713+0747 pollutes the common red-noise process with low spectral index noise, and we use a tailored noise model to remove these effects.

J S Hazboun↗

Jupiter Atmospheric Science with JIMO: Linking Science Objectives and Measurement Goals

Although the primary focus of the Jupiter Icy Moons Orbiter (JIMO) mission will be the characterization and study of Jupiter's icy moons, there will be opportunities throughout the mission for unprecendented observations of Jupiter. With an adaptable suite of payload instruments, the atmospheric data collected by JIMO can help to answer fundamental questions about the largest planet in our solar system that remain after (or were generated by) previous spacecraft reconnaissance (e.g. Voyager, Galileo, and Cassini). Near-IR (0.7-4 micron) spectral imaging will most likely be used to identify mineralogies and ices on the Jovian satellites by virtue of their spectral signatures. This same capability is very well tailored for studies of Jovian atmospheric dynamics and structure. Near-IR methane absorption bands allow 2-D mapping of the horizontal wind field at size scales to tens of kms, as well as the height dependence of this field above the ammonia cloud deck (700 to a few mbar), constraining current models of atmospheric vertical structure. Likewise, atmospheric ice aerosols with unique spectroscopic signatures (ammonia ice near 1.5, 2.0, and 2.8 microns and water ice between 3.0 - 3.5 microns) can be detected and mapped using spectral difference imaging or spectrally inclusive principal-component methods. Spectral imaging of the Jovian aurora via (3)H(+) emission lines between 3 - 4 microns can be used to spatially map the interplay between the satellites) Jupiter's magnetosphere, and Jupiter's atmosphere. Each of these measurements addresses one or more fundamental questions related to the energy balance in Jupiter's atmosphere. All of these tunable imaging objectives can be achieved using acousto-optic tunable filters (AOTF's), which have been used for years in ground-based observing instruments and which have been proposed for numerous planetary missions. The application of this technology to the science objectives of both the icy satellites and Jovian atmospheric components of the JIMO mission will be discussed.

Chanover, N. J.↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

Multi-Band GaAs/AlGaAs Quantum Well Infrared Photodetector (QWIP) Focal Plane Arrays

The GaAs/AlGaAs based Quantum Well Infrared Photodetectors (QWIPs) afford greater flexibility than the usual extrinsically doped semiconductor IR detectors because the wavelength of the peak response and cutoff can be continuously tailored over any wavelength between 6-20 micrometers. The spectral band width of these detectors can be tuned from narrow (DELTA)lamba/lamba approx. 10 %)) to wide (DELTA)lamba/lamba approx. 50 %) allowing various applications. Also, QWIP offers multi-color infrared cameras which is capable of simultaneously acquiring images in different infrared bands. Each pixel of such array consists of vertically stacked, independently readable, QWIP detectors sensitive in different narrow infrared bands. In this article, we discuss the development and results of the 640 x 512 dual-band and four-band QWIP FPAs.

Bandara, S. V.↗

Theoretical description of spectral line profiles of parent molecules in cometary comae

The present overview of cometary spectral-line profiles obtainable through advancements in high-resolution spectroscopic studies, which allow the retrieval of coma kinematic properties from velocity-resolved spectral-line profiles, incorporates the most important gas dynamic processes into an outflow model which is tailored to the interpretation of spectroscopic observations of parent molecules. The model is then used to study the influence on parent-molecule spectral line profile formation of the field-of-view, the expansion velocity, the kinetic temperature, and the anisotropic outflow distributions.

Hu, Hong-Yao↗

Bandwidth Efficient Baseband Multi-Modulator

The High Rate Baseband Multi-Modulator (HRBM) ASIC is being developed to provide High-speed Bandwidth Efficient Modulations to NASA missions. Bandwidth efficiencies from 2.0 bits/symbol/Hz to 2.75 bits/symbl/Hz are selectable from three CCSDS modulations: Gaussian Minimum Shift Keying (GMSK), Filter Offset Quadrature Phase Shift Keying (Filtered- OQSK) and 8-Phase Shift Keying Trellis Coded Modulation (8-PSK TCM). An FPGA version of the HRBM is developed first to verify the individual modulation designs and characterize timing and performance issues involved with digital baseband modulation synthesis. A Finite Input Response (FIR) filter is included to provided baseband pulse shaping to reduce out-of-band spectral emissions. This is filter is programmable and can be tailored to meet system requirements. The ASIC is targeted to provide up to 600 Mbps throughput and will provide serial as well as parallel input. This paper provides an overview of the technology development and current status.

Fong, Wai↗

Avoided Level Crossing and Entangled States of Interacting Hydrogen Molecules Detected by the Quantum Superposition Microscope

Pump–probe measurements by ultrashort THz pulses can be used to excite and follow the coherence dynamics in the time domain of single hydrogen molecules (H 2 ) in the junction of a scanning tunneling microscope (STM). By tailoring the resonance frequency through the sample bias, we identified two spectral signatures of the interactions among multiple H 2 molecules. First, the avoided level crossing featured by energy gaps ranging from 20 to 80 GHz was observed because of the level repulsion between two H 2 molecules. Second, the tip can sense the signal of H 2 outside the junction through the projective measurement on the H 2 inside the junction, owing to the entangled states created through the interactions. A dipolar-type interaction was integrated into the tunneling two-level system model of H 2 , enabling accurate reproduction of the observed behaviors. Furthermore, our results obtained by the quantum superposition microscope reveal the intricate quantum mechanical interplay among H 2 molecules and additionally provide a 2D platform to investigate unresolved questions of amorphous materials.

36 MATERIALS SCIENCE↗

Quantum sensing effect of electron tunneling in DQD/analyte complex

We investigate electron tunneling between quantum dots and molecules to propose a quantum sensor. This sensor consists of double quantum dots (DQD) with energy levels specifically tailored to mirror those of the target analyte. By analyzing the spectral distribution of electron localizations in the DQD system, we can delineate the analyte’s spectrum and deduce its composition by comparing it with a reference sample. To understand electron tunneling dynamics within the DQD/analyte complex, we performed three-dimensional computational modeling applying the effective potential approach to the InAs/GaAs heterostructure. In this modeling, we mimicked the analyte spectrum by utilizing a quantum well characterized by a quasi-discrete spectrum. Our calculations reveal the inherent potential of utilizing this method as a highly sensitive and selective sensor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

Controlling Interfacial Charge Separation Energetics and Kinetics

The overall goal is to probe electron transfer kinetics of the Marcus inverted region at interfaces. This project specifically uses a dye‐semiconductor interface with a reversible electron transfer reagent in solution where the semiconductor conduction band and electron transfer reagent ideally have a potential energy difference firmly within the Marcus inverted region. The goals of this project are: (Goal 1) Identify dye design elements that give dyes with low energy ground‐state oxidation potentials while retaining desirable electron transfer kinetics at the semiconductor interface. (Goal 2) Identify dye designs with excited‐state oxidation potentials set to fixed energies through molecular design while the dye ground‐state oxidation potentials are varied to allow for the evaluation of varied electron transfer reagents/redox shuttles (RS) with different free energies for electron transfer. (Goal 3) Within the context of the functionality identified in goals 1 and 2, goal 3 seeks to design dyes with features maximizing charge carrier lifetimes by minimizing recombination losses at metal oxide interfaces with high voltage systems. (Goal 4) Probe electron transfer kinetics in a high voltage‐dye sensitized solar cell with both the oxidized dye and RS firmly within the Marcus inverted region with regard to the TiO2 CB. (Goal 5) Identify tailored sensitizer/redox shuttle pairs with desirable electron transfer kinetics in defined spectral regions capable of “banding off” incident solar irradiation to give high voltage multijunction systems capable of exceeding the Shockley‐Queisser limit and powering catalytic processes.

14 SOLAR ENERGY↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC): A Payload Designed for Exploration of Terrestrial Planetary Bodies

Geological materials (indeed, all solid objects) are characterized by their crystal structure, elemental composition, and morphology. The Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC) instrument suite quantifies all three. These measurements address fundamental science questions (e.g., the origin and evolution of planetary bodies) and support the human exploration of space (e.g., the characterization of regolith for ISRU and the constraint of its geotechnical properties). METRIC comprises an X-ray Diffraction/X-ray Fluorescence instrument (XRD: mineral structure and XRF: elemental composition), an X-ray micro-Computed Tomography instrument (XCT: 3D internal micromorphology), and a hyperspectral imaging infrared spectrometer (IRS) to provide local/regional mineralogic context for these measurements. METRIC XRD/F draws heritage from the highly successful Mars Science Laboratory CheMin instrument. The METRIC XRD/F employs two separate sample cells, one optimized for XRD and one for XRF, resulting in more rapid XRD analysis (tens of minutes vs. tens of hours for CheMin) and an orders-of-magnitude improvement in XRF detection. XCT has not been deployed in space, so the METRIC XCT represents a new capability for solar system exploration. The XCT uses the same basic high-TRL components as METRIC XRD/F, decreasing its development cost for flight. The METRIC IRS is a derivative of the NASA Earth Science Technology Office funded Hyperspectral Thermal Imager instrument and utilizes the NASA Technology Transfer Program to incorporate a commercial-of-the-shelf infrared camera ruggedized for space by NASA Marshall Space Flight Center. The IRS spectral range (8–14 µm) and resolution (10.8 cm -1 ) are tailored to quantify mineralogy in rocks using their characteristic Reststrahlen bands and to characterize mineralogy of soils using the position of the Christensen Feature. The METRIC payload is currently designed for deployment to the Moon on a Commercial Lunar Payload Services (CLPS) mission, where the XRD/F and XCT would be located on a lander and the IRS would be on deployed on a companion rover to evaluate the mineralogical diversity of the landing site. A pneumatic drill designed by Honeybee Robotics would excavate regolith up to 50 cm below the lander and deliver multiple aliquots of regolith to the XRD/F and XCT. The METRIC payload could also be deployed on a rover. In this case, a sample handling system on a robotic arm could scoop regolith and/or drill rocks and deliver powder to the XRD/F and XCT located in the rover’s interior. Alternatively, METRIC instruments could be used singly or in combination on human space missions. The XRD/F and XCT could be used to characterize samples in a rover or in a science laboratory within a habitat. These data could help astronauts identify resource-enriched rocks and regolith and triage geologic samples to return samples of high interest for analysis in terrestrial laboratories. The IRS could be attached to a human-navigated rover to collect mineralogical data along a traverse and identify high-priority science samples.

E. B. Rampe↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

Spectral and photochemical diversity of tandem cysteine cyanobacterial phytochromes

The atypical trichromatic cyanobacterial phytochrome NpTP1 from Nostoc punctiforme ATCC 29133 is a linear tetrapyrrole (bilin)-binding photoreceptor protein that possesses tandem-cysteine residues responsible for shifting its light-sensing maximum to the violet spectral region. Using bioinformatics and phylogenetic analyses, in this study we established that tandem-cysteine cyanobacterial phytochromes (TCCPs) compose a well-supported monophyletic phytochrome lineage distinct from prototypical red/far-red cyanobacterial phytochromes. To investigate the light-sensing diversity of this family, we compared the spectroscopic properties of NpTP1 (here renamed NpTCCP) with those of three phylogenetically diverged TCCPs identified in the draft genomes of Tolypothrix sp. PCC7910, Scytonema sp. PCC10023, and Gloeocapsa sp. PCC7513. Recombinant photosensory core modules of ToTCCP, ScTCCP, and GlTCCP exhibited violet-blue–absorbing dark-states consistent with dual thioether-linked phycocyanobilin (PCB) chromophores. Photoexcitation generated singly-linked photoproduct mixtures with variable ratios of yellow-orange and red-absorbing species. The photoproduct ratio was strongly influenced by pH and by mutagenesis of TCCP- and phytochrome-specific signature residues. Our experiments support the conclusion that both photoproduct species possess protonated 15E bilin chromophores, but differ in the ionization state of the noncanonical “second” cysteine sulfhydryl group. We found that the ionization state of this and other residues influences subsequent conformational change and downstream signal transmission. We also show that tandem-cysteine phytochromes present in eukaryotes possess similar amino acid substitutions within their chromophore-binding pocket, which tune their spectral properties in an analogous fashion. Taken together, our findings provide a roadmap for tailoring the wavelength specificity of plant phytochromes to optimize plant performance in diverse natural and artificial light environments.

59 BASIC BIOLOGICAL SCIENCES↗