Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

3D Printable Polymers for Radiological Applications

Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Grid-Signal Distortions Using the Spectral Correlation Function

This study proposes a novel method for signal detection and feature extraction based on the spectral correlation function, enabling improved characterization of grid-signal distortions. Our approach differs from existing treatments of signal distortion in its analysis of the varied spectral content of signals observed in real-world scenarios. The method we propose has state-of-the-art discriminative power that provides meaningful and understandable characterizations of various grid events and anomalies. In conclusion, to validate the approach, we use real world data from the Grid Event Signature Library, which is maintained jointly by Oak Ridge National Laboratory and Lawrence Livermore National Laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion↗

Bell state analyzer for spectrally distinct photons

We demonstrate a Bell state analyzer that operates directly on frequency mismatch. Based on electro-optic modulators and Fourier-transform pulse shapers, our quantum frequency processor design implements interleaved Hadamard gates in discrete frequency modes. Experimental tests on entangled-photon inputs reveal fidelities of ∼ <#comment/> 98 % <#comment/> for discriminating between the | Ψ <#comment/> + ⟩ <#comment/> and | Ψ <#comment/> − <#comment/> ⟩ <#comment/> frequency-bin Bell states. Our approach resolves the tension between wavelength-multiplexed state transport and high-fidelity Bell state measurements, which typically require spectral indistinguishability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multimodal Imaging of Autofluorescent Sites Reveals Varied Chemical Speciation in SSZ-13 Crystals

Here, a multimodal imaging study of chabazite is used to show the distribution of and discriminate between different emissive deposits arising as a result of the detemplation process. 3D confocal imaging, fluorescence lifetime imaging, spectral imaging, and Raman mapping are used to show three different types of emissive behaviours each characterised by different spatial distributions, trends in lifetime, spectral signals, and Raman signatures. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits, which experience lifetime augmentation due to spatial confinement. The distribution of organic residue throughout the crystal volume is comparable to XRF mapping that shows Si enrichment on the outer edges and higher Al content through the centre, demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

The role of chalcogen vacancies for atomic defect emission in MoS 2

For two-dimensional (2D) layered semiconductors, control over atomic defects and understanding of their electronic and optical functionality represent major challenges towards developing a mature semiconductor technology using such materials. Here, we correlate generation, optical spectroscopy, atomic resolution imaging, and ab initio theory of chalcogen vacancies in monolayer MoS 2 . Chalcogen vacancies are selectively generated by in-vacuo annealing, but also focused ion beam exposure. The defect generation rate, atomic imaging and the optical signatures support this claim. We discriminate the narrow linewidth photoluminescence signatures of vacancies, resulting predominantly from localized defect orbitals, from broad luminescence features in the same spectral range, resulting from adsorbates. Vacancies can be patterned with a precision below 10 nm by ion beams, show single photon emission, and open the possibility for advanced defect engineering of 2D semiconductors at the ultimate scale.

36 MATERIALS SCIENCE↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaching For New Physics With MeV-scale Reconstruction In The MicroBooNE LArTPC Neutrino Detector

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing MeV-Scale energy depositions, or blips, in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV scale using reconstructed blips in MicroBooNE LArTPC data at Fermilab. A concentration of low-energy ($<$3 MeV) blips is observed around fiberglass mechanical support struts along the TPC edges, with spectral features consistent with the Compton edge of the 2.614 MeV $^{208}$Tl decay $\gamma$ ray. With these features we perform the electron energy scale calibration to few-percent precision and yield the specific activity of $^{208}$Tl in the struts, $(11.7 \pm 0.2 \text{(stat)} \pm 2.8 \text{(syst)})$ Bq/kg. Using cosmogenic blips above 3 MeV, we demonstrate the ability of large LArTPCs to discriminate low-energy proton and electron depositions. An enriched low-energy proton sample selected with this technique is smaller in data than in dedicated CORSIKA simulations, pointing to possible mismodeling in CORSIKA incident cosmic fluxes or Geant4 particle transport. These methods are applied to MicroBooNE's inclusive single-photon search, which reported a 2.2$\sigma$ excess below 600 MeV in shower energy for events with no reconstructed protons. By identifying and classifying blips near single-photon events selected by the WireCell reconstruction framework, a more comprehensive labeling of nearby hadronic activity is established: blips upstream of the shower axis indicate previously unidentified final-state protons, while elevated blip counts at wide angles signal final-state neutrons. Taken together with MiniBooNE's long-standing low-energy excess (LEE) and MicroBooNE electron-like and sterile neutrino searches disfavored as possible explanations of the MiniBooNE anomaly, this analysis motivates an expanded exploration of the single-photon channel in Fermilab's short-baseline LArTPC program. This thesis documents the current status of this enhanced analysis, which will form a key part of MicroBooNE's final low-energy-excess results.

Andrade Aldana, Diego Armando [IIT, Chicago (main)↗

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials. Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., 235 U or 233 U) fraction, such as highly enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the “primary” delayed neutrons (emitted directly by fission fragments) and the “secondary prompt” fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from “primary” delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. Here, we demonstrate two experimental approaches for discriminating between 235 U and 238 U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

07 ISOTOPE AND RADIATION SOURCES↗

Prospects for detecting UF6 hydrolysis intermediates by mass spectrometry, resonance Raman, and NQR spectroscopy

Simulations are performed to consider several spectrometric and spectroscopic candidates for elucidating the mechanism of the hydrolysis of uranium hexafluoride (UF6). This study is among the first to benchmark the def-mTZVP basis sets for actinide-containing molecules, and it is shown to be a suitable basis set for surveying geometrical structures and vibrational spectra when used in conjunction with density functional theory. An experiment is proposed coupling mass spectrometric ion selection with vibrational spectroscopy, and supporting infrared and Raman spectral simulations demonstrate that ionization blue-shifts bands and can change their qualitative features. Ultraviolet resonance Raman is shown to have good prospects for discriminating U–O–U bridged intermediates, evidence for which was observed recently [L. E. McNamara et al., J. Phys. Chem. A 130, 775–786 (2026)]. As a more speculative approach, we also consider the prospect of addressing 233U or 235U nuclei by quadrupole resonance (NQR) spectroscopy for assigning early stage intermediate complexes. In doing so, we provide a first order-of-magnitude estimate for the collision-induced NQR signal for the UF6 dimer, which is of interest for the interpretation of a fast decoherence time observed in liquid-phase nuclear magnetic resonance. Having provided critical insights into the formation and stability of UF6 hydrolysis intermediates in previous studies, this computational spectroscopy survey is expected to help guide and expedite future laboratory campaigns.

Lutz, Jesse J. [Center for Computing Research, San↗

Huge ensembles – Part 1: Design of ensemble weather forecasts using spherical Fourier neural operators

Abstract. Simulating low-likelihood high-impact extreme weather events in a warming world is a significant and challenging task for current ensemble forecasting systems. While these systems presently use up to 100 members, larger ensembles could enrich the sampling of internal variability. They may capture the long tails associated with climate hazards better than traditional ensemble sizes. Due to computational constraints, it is infeasible to generate huge ensembles (comprised of 1000–10 000 members) with traditional, physics-based numerical models. In this two-part paper, we replace traditional numerical simulations with machine learning (ML) to generate hindcasts of huge ensembles. In Part 1, we construct an ensemble weather forecasting system based on spherical Fourier neural operators (SFNOs), and we discuss important design decisions for constructing such an ensemble. The ensemble represents model uncertainty through perturbed-parameter techniques, and it represents initial condition uncertainty through bred vectors, which sample the fastest-growing modes of the forecast. Using the European Centre for Medium-Range Weather Forecasts Integrated Forecasting System (IFS) as a baseline, we develop an evaluation pipeline composed of mean, spectral, and extreme diagnostics. With large-scale, distributed SFNOs with 1.1 billion learned parameters, we achieve calibrated probabilistic forecasts. As the trajectories of the individual members diverge, the ML ensemble mean spectra degrade with lead time, consistent with physical expectations. However, the individual ensemble members' spectra stay constant with lead time. Therefore, these members simulate realistic weather states during the rollout, and the ML ensemble passes a crucial spectral test in the literature. The IFS and ML ensembles have similar extreme forecast indices, and we show that the ML extreme weather forecasts are reliable and discriminating. These diagnostics ensure that the ensemble can reliably simulate the time evolution of the atmosphere, including low-likelihood high-impact extremes. In Part 2, we generate a huge ensemble initialized each day in summer 2023, and we characterize the simulations of extremes.

Mahesh, Ankur↗

Artificial illumination identification from an unmanned aerial vehicle

Artificial illumination identification within images is a useful tool for many applications. Performing such identification allows for an estimation of the illumination source spectrum, which in turn can be used for additional applications ranging from spectral detection and exploitation to statistics about nighttime light usage. Illumination identification has been performed in laboratory settings but not from an unmanned aerial vehicle (UAV) platform. Here, we test the feasibility of using a UAV and commercial off-the-shelf multispectral imaging sensor to perform such artificial illumination identification through linear discriminant analysis using nighttime UAV images. The results are very promising, showing source classification accuracies of 83.3%, 92.3%, 100%, and 100% for the incandescent, light-emitting diode, high pressure sodium, and metal halide illumination sources, respectively. We show that the information gained from the source identification can be further used to inform additional analysis, such as spectral identification. The high resolution of UAV imaging techniques combined with the knowledge of the illumination source can lead to better exploitation of such nighttime data for many applications.

42 ENGINEERING↗

Experimental methods for laboratory measurements of helium spectral line broadening in white dwarf photospheres

White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Machine Learning-Driven Mass Spectrometric Identification of Trichothecenes in the Absence of Standard Reference Materials

While a significant body of work exists on the detection of commonly known trichothecene toxins, biological, environmental, and other transformational processes can generate many under-characterized and unknown modified trichothecenes. Lacking both analytical reference standards and associated mass spectral databases, identification of these modified compounds reflects both a challenge and a critical gap from forensic and public health perspectives. Here we report here the application of machine learning (ML) techniques toward identification of discriminative fragment ions from mass spectrometric data that can be exploited to detect evidence of type A and B trichothecenes. The goal of this work is to establish a new method for the identification of unknown, though structurally similar trichothecenes, by leveraging objective ML techniques. Discriminative fragments derived from a series of gradient-boosted machine learners are then used to develop ML-driven precursor ion scan (PIS) methods on a triple quadrupole mass spectrometer (QQQ) for screening of “unknown unknown” trichothecenes. Specifically, we apply the PIS method to a laboratory-synthesized trichothecene, a first step in demonstrating the power of alternative, machine learning-driven mass spectrometric methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Curious Case of PHL 293B: A Long-lived Transient in a Metal-poor Blue Compact Dwarf Galaxy

We report on small-amplitude optical variability and recent dissipation of the unusually persistent broad emission lines in the blue compact dwarf galaxy PHL 293B. The galaxy’s unusual spectral features (P Cygni-like profiles with ~800 km s -1 blueshifted absorption lines) have resulted in conflicting interpretations of the nature of this source in the literature. However, analysis of new Gemini spectroscopy reveals the broad emission has begun to fade after being persistent for over a decade prior. Precise difference imaging light curves constructed with the Sloan Digital Sky Survey and the Dark Energy Survey reveal small-amplitude optical variability of ~0.1 mag in the g band offset by 100 ± 21 pc from the brightest pixel of the host. The light curve is well-described by an active galactic nuclei (AGN)-like damped random walk process. However, we conclude that the origin of the optical variability and spectral features of PHL 293B is due to a long-lived stellar transient, likely a Type IIn supernova or nonterminal outburst, mimicking long-term AGN-like variability. This work highlights the challenges of discriminating between scenarios in such extreme environments, relevant to searches for AGNs in dwarf galaxies. This is the second long-lived transient discovered in a blue compact dwarf, after SDSS1133. Furthermore, our result implies such long-lived stellar transients may be more common in metal-deficient galaxies. Systematic searches for low-level variability in dwarf galaxies will be possible with the upcoming Legacy Survey of Space and Time at the Vera C. Rubin Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Seismic Spatial Gradients and Machine Learning-Based Classifiers for Explosion Monitoring (LDRD 218327)

This final report summarizes the work completed under the Laboratory Directed Research and Development (LDRD) project “Seismic Spatial Gradients as a Machine Learning-Based Classifier for Explosion Monitoring.” The overarching goal of the project was to explore the efficacy of using machine learning-based classification algorithms where the input data are the spatial gradient of the seismic wavefield collected at a single point on the Earth’s surface. The methods that I describe here are in direct contrast to conventional methods of seismic discrimination which typically rely on a spatially extended network of instruments and physics-based wavefield attributes such as, for example, the ratio between $\textit{P}$ and $\textit{S}$ waves. Rather, we use the spatial gradient of the seismic wavefield observed at a single point on the Earth’s surface and data processing approaches inspired by the machine learning community. We tested two algorithms, a neural network and a modified version of principal component analysis termed Spectrally Filtered Principal Component Analysis (SFPCA). To test these algorithms, we first conducted a series of numerical tests using synthetic data and then conducted a small-scale controlled field experiment. The tests using synthetic data showed that both algorithms had high success rates on gradiometric data, even when simulated noise was added to the signal. Furthermore, we found that using seismic spatial gradients increased the performance of our discrimination algorithms when compared to using just the traditional translational motion seismic data. The tests with field data also showed a high degree of discriminative success.

58 GEOSCIENCES↗