Resonance Trajectories and Island Tune Spectra in the Tune Domain

Island tune spectra are introduced, beginning with curves of resonance trajectories plotted in the (Q x , Q I ) tune domain plane (where Q x is horizontal tune and Q I is island tune) for many resonance orders N. A slice in the (Q x , Q I ) plane delivers a Q I -spectrum at a fixed horizontal tune, with one spectral line for every appropriate value of N.

43 PARTICLE ACCELERATORS↗

Abundances of Neutron-capture Elements in 62 Stars in the Globular Cluster Messier 15

M15 is a globular cluster with a known spread in neutron-capture elements. This paper presents abundances of neutron-capture elements for 62 stars in M15. Spectra were obtained with the Michigan/Magellan Fiber System spectrograph, covering a wavelength range from ~4430 to 4630 Å. Spectral lines from Fe I , Fe II , Sr I , Zr II , Ba II , La II , Ce II , Nd II , Sm II , Eu II , and Dy II were measured, enabling classifications and neutron-capture abundance patterns for the stars. Of the 62 targets, 44 are found to be highly Eu-enhanced r-II stars, another 17 are moderately Eu-enhanced r-I stars, and one star is found to have an s-process signature. The neutron-capture patterns indicate that the majority of the stars are consistent with enrichment by the r-process. The 62 target stars are found to show significant star-to-star spreads in Sr, Zr, Ba, La, Ce, Nd, Sm, Eu, and Dy, but no significant spread in Fe. The neutron-capture abundances are further found to have slight correlations with sodium abundances from the literature, unlike what has been previously found; follow-up studies are needed to verify this result. The findings in this paper suggest that the Eu-enhanced stars in M15 were enhanced by the same process, that the nucleosynthetic source of this Eu pollution was the r-process, and that the r-process source occurred as the first generation of cluster stars was forming.

79 ASTRONOMY AND ASTROPHYSICS↗

Increased Ly α Opacity in White Dwarf Photospheres from Transient H − Resonances

The structure and emergent flux of hydrogen atmosphere white dwarfs depend on the opacity of the Lyα and Lyβ spectral lines. The opacity here is set by the strength and broadening of these lines; the latter is dictated by the far line wing, which is in the “quasi-static” limit of electron broadening, placing it in the incomplete collision regime, and describes the transient parts of electron and ion collisions. These transient stages of the collision form resonances: In the case of ions, they manifest as molecular resonances, while for electrons they are H − resonances, both of which can only be captured quantum-mechanically. Quantum-mechanical calculations have historically preserved only a handful of broadening terms that are most important near the center of the line. However, in the wings of the line, the previously neglected terms that describe the transient stages of the collision need to be included. This requirement arises because, in the line wings, the broadening from the 1s ground state, which is generally assumed to be extremely small compared to the broadening of the upper state, is no longer negligible within a quantum-mechanical model that takes into account exchange interactions. The inclusion of all the transient terms results in asymmetries and extra broadening. The increased broadening of Lyα increases the opacity at the energy where most of the flux leaves the star. The broader Lyα lines also impact the visible flux, raising it by an amount that exceeds previously estimated errors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark of the Fe xvv 𝓡 ratio in photoionized plasma during eclipse of Centaurus X-3 with XRISM/Resolve

The $\mathcal {R}$ ratio is a useful diagnostic of the X-ray emitting astrophysical plasmas and is defined as the intensity ratio of the forbidden over the inter-combination lines in the K$\alpha$ line complex of He-like ions. The value is altered by excitation processes (electron impact or UV photoexcitation) from the metastable upper level of the forbidden line, thereby constraining the electron density or UV field intensity. The diagnostic has been applied mostly in electron density constraints in collisionally ionized plasmas using low-Z elements, as was originally proposed for the Sun (Gabriel & Jordan, 1969a, MNRAS, 145, 241), but it can also be used in photoionized plasmas. To make use of this diagnostic, we need to know its value in the limit of no excitation of metastables ($\mathcal {R}_{0}$), which depends on the element, how the plasmas are formed, how the lines are propagated, and the spectral resolution affecting line blending principally with satellite lines from Li-like ions. We benchmark $\mathcal {R}_0$ for photoionized plasmas by comparing calculations using radiative transfer codes and observation data taken with the Resolve X-ray microcalorimeter onboard XRISM. We use the Fe xxv He$\alpha$ line complex of the photo-ionized plasma in Centaurus X-3 observed during eclipse, in which the plasma is expected to be in the limit of no metastable excitation. The measured $\mathcal {R} = 0.65 \pm 0.08$ is consistent with the value calculated using xstar for the plasma parameters derived from other line ratios of the spectrum. We conclude that the $\mathcal {R}$ ratio diagnostic can be used for high-Z elements such as Fe in photoionized plasmas, which has wide applications in plasmas around compact objects at various scales.

X-rays: binaries↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of a distinct collective mode in Kagome superconductors

The collective modes of the superconducting order parameter fluctuation can provide key insights into the nature of the superconductor. Recently, a family of superconductors has emerged in non-magnetic kagome materials AV 3 Sb 5 (A = K, Rb, Cs), exhibiting fertile emergent phenomenology. However, the collective behaviors of Cooper pairs have not been studied. Here, we report a distinct collective mode in CsV 3-x Ta x Sb 5 using scanning tunneling microscope/spectroscopy. The spectral line-shape is well-described by one isotropic and one anisotropic superconducting gap, and a bosonic mode due to electron-mode coupling. With increasing x, the two gaps move closer in energy, merge into two isotropic gaps of equal amplitude, and then increase synchronously. The mode energy decreases monotonically to well below 2Δ and survives even after the charge density wave order is suppressed. We propose the interpretation of this collective mode as Leggett mode between different superconducting components or the Bardasis-Schrieffer mode due to a subleading superconducting component.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ground state rotational and kinetic temperatures of C 2 molecules in a laser-produced plasma

This study presents an experimental comparison between rotational and kinetic temperatures of molecular species in a laser-produced plasma, utilizing tunable laser absorption spectroscopy. We analyzed high-resolution and time-resolved absorption spectra of 31 rotational transitions within the Phillips A 1 II u –X 1 Σ g 3-0 band of the C 2 molecule, measured from a laser-produced graphite plasma in ~2 Torr argon, within the 771–781 nm spectral range. Spectral fitting provided quantitative state column densities of C 2 rotational energy levels in the ground electronic and vibrational states. Boltzmann analysis revealed thermalized rotational distributions showing rotational temperatures decreasing from 3000 to 600 K within 5–500 μs following the onset of the laser plasma. The measured kinetic and rotational temperatures of C 2 molecules are comparable, suggesting that collisional processes in the laser-produced plasma are sufficient to maintain thermal equilibrium between the C 2 molecules and the Ar background gas.

Absorption spectroscopy↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual-frequency-comb UV spectroscopy with one million resolved comb lines

We present high-resolution dual-comb spectroscopy across two broad UV spectral regions spanning 372–410 nm and 325–342 nm. This is achieved by generating sixth and seventh harmonics, respectively, from a low-noise 2.35 µm Cr:ZnS dual-comb laser system. The sixth harmonic band contains approximately 1,000,000 spectrally resolved comb lines, while the seventh harmonic band—around 550,000 comb lines. With the line spacing of 80 MHz, this corresponds to a resolving power of up to 10 million, offering remarkable spectral resolution.

Muraviev, Andrey↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

The Emission and Suppression of Line Features in Luminous Transients

Featureless optical and ultraviolet (UV) spectra are a puzzling signature to emerge from recent observations of luminous fast blue optical transients (LFBOTs) and some tidal disruption events (TDEs). We describe the landscape of source and gas properties that are expected to form H, He I , and He II emission lines, and map spectral types to the parameter space of luminosity and system radius. Using one-dimensional radiative transfer calculations, we show that high source luminosities (L > 10 44 erg s −1 ) and compact ejecta radii (r < 10 14 cm) produce featureless spectra, due to the high temperature and ionization state of the emitting medium. Intermediate luminosities and moderately compact systems can generate He II -dominated spectra, while lower luminosities and more extended atmospheres result in conspicuous H and He I emission. Large expansion velocities (v ≥ 0.1c) can further broaden lines such that they blend into the continuum. Featureless UV spectra may require even more extreme ionization environments or velocities in order to suppress the many intrinsically strong metal lines at those wavelengths. Applying this framework to understand the absence of features observed in LFBOTs and featureless TDEs, we find that, under the optically thick, quasi-thermal conditions considered here, nonhomologous, compact outflows are likely necessary for featurelessness to persist in optical and UV spectra.

Aspegren, Olivia [University of California, Berkel↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Sub-melt nanosecond pulsed-laser induced densification and strain-field relaxation in single-crystal diamond

Dislocations and polishing-induced defect networks in synthetic diamond introduce local strain fields and broaden Raman features, limiting performance in optical, thermal, and electronic applications. Laser annealing is emerging as a promising approach to repair surface and near-surface defects in diamond without entering the melt regime, yet surface densification, defect-state modification, and associated structural changes have not been well quantified. In this work, we show that sub-melt nanosecond pulsed-laser annealing (PLA) induces near-surface densification and defect-mediated strain relaxation in single-crystal Chemical Vapor Deposition (CVD) diamond. Single- and two-pulse PLA were applied, and structural evolution was quantified using co-registered ISO 25,178 white-light interferometry, depth-resolved Raman spectroscopy, and cross-sectional STEM with geometric phase analysis (GPA). Across a 5 × 6 grid (n = 30), responsive regions exhibit large reductions in local slope (Sdq 45–65%), developed area (Sdr 60–90%), height spread (Sp, Sz 30–65%), void volume (Vv 57–60%), and roughness amplitude (Sa, Sq 48–57%), consistent with densification of ∼4–6.5 nm. Raman profiling shows narrowing of the diamond line and improved spectral uniformity to depths of ∼2–3 μm. Given that the Raman probing depth significantly exceeds the densified layer thickness, this response is interpreted as consistent with long-range strain-field redistribution originating from the near-surface region. STEM-GPA strain maps further support this interpretation, showing smoother strain fields, suppressed hotspots, and redistribution of localized strain concentrations following PLA. These results are consistent with defect-mediated strain relaxation and densification-driven modification of the near-surface energy state. The approach provides a scalable pathway for improving near-surface structural quality in diamond relevant to electronic, photonic, and quantum applications.

Areal surface metrology (ISO 25,178)↗

Ab-initio simulation of spin-vibronic spectra of methoxy radical

Despite the fact that experimental and theoretical work on the spectrum of methoxy has stretched from the microwave to the ultraviolet and proceeded for nearly 50 years, parts of the spectrum have remained a challenge to simulate theoretically and make reliable line-by-line assignments. The spectral complexity arises because the radical has a non-zero electron spin and significant vibronic coupling between the two elec- tronic components of the ground state due to the presence of a conical intersection. This work describes a completely ab initio effort to understand and assign the spin- vibronic levels of the X 2E state from 0 to above 3000 cm−1, a region that includes the fundamental transitions of the C-H symmetric and asymmetric stretches that have not previously been identified uniquely. A potential energy surface for methoxy was calculated at the EOM-CCSDT/ANO1 level of theory. Subsequently this potential energy surface was fit to a quartic power series expansion of all nine vibrational nor- mal coordinates (as determined at the minimum of the conical intersection) by the use of a machine-learning-based algorithm. After the addition of spin-orbit coupling, the spin-vibronic problem was solved using both the Krylov-Schur and Lanczos algorithms with the SOCJT3 software to converge eigenvalues up to 3500 cm−1 and their eigen- vectors. The latter were used, in conjunction with the calculated dipole moment and its derivatives (calculated using finite differences at EOM-CCSDT/ANO1 level), to determine spectral intensities for the spin-vibronic spectra. The calculated transition frequencies and intensities were used to simulate and assign the observed transitions of the spin-vibronic spectra of the radical. The credibility of the assignments and their significance is discussed in detail.

Sharma, Ketan [University of Florida, Gainesville,↗

Characterization of core neutrals using passive measurements of the D α spectrum near the X -point in the DIII-D tokamak

New spectroscopic measurements of deuterium Balmer-α emission are used to infer the spatial distribution of neutral particles near the X-point in a diverted high confinement mode plasma. The charge exchange neutral spectroscopy (CENS) diagnostic—recently installed on the DIII-D tokamak—uses 15 lines of sight extending from the edge of the confined region (ρ ≈ 0.7) to the X-point in lower single-null plasmas. Each CENS line of sight is spectrally resolved around the deuterium Balmer-α wavelength (6561 Å) to measure the Doppler shift, line broadening, and intensity of Dα emission. Thermal line broadening is used to identify emission from neutrals undergoing charge-exchange (CX) with high temperature ions in the confined plasma. This spectral information allows a more accurate determination of the neutral density deeper inside the confined plasma compared to traditional filter-based diagnostics. We present two methods of analyzing CENS measurements: (1) fitting the spectrum from each view-chord separately, and (2) a tomographic method for inverting the neutral density over a 2D region of space using all CENS views collectively. The neutral density profile is found to decay exponentially in the radial direction with two scale-lengths. In the pedestal region the neutral density decays at a rate approximately equal to the local mean-free-path for CX collisions, $L_{n_\mathrm{D0}}\approx \lambda_\text{CX}$. Further inside the plasma the neutral density decays at a rate equal to the mean-free-path for ionization, $L_{n_\mathrm{D0}}\approx \lambda_\text{inz.}$. The separatrix $n_\mathrm{D0}$ value is found to be approximately $2\times10^{15}$ m−3. Based on results from the 2D inversion, the density of neutrals is found to increase along the separatrix approaching the X-point by a factor of $\approx 5\times$ over the region covered by the CENS diagnostic.

X-point neutrals↗