Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopic techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analytical Tools to Assess Polymer Biodegradation: A Critical Review and Recommendations

Many petroleum-derived plastic materials are highly recalcitrant and persistent in the environment, posing significant threats to human and ecological receptors due to their accumulation in ecosystems. In recent years, research efforts have focused on advancing biological methods for polymer degradation. Enzymatic depolymerization has emerged as particularly relevant for biobased plastic recycling, potentially scalable for industrial use. Biodegradation involves adsorption to the plastic solid surface, followed by an interfacial reaction, resulting in cleavage of bonds of polymer chains exposed on the surface. Here, widely varying substrate-specific kinetics are observed, with the polymer’s properties possessing a significant impact on the rate of this interfacial catalysis. Thus, there is a critical need for sensitive and accurate characterization of the material surface during and after interfacial depolymerization to fully understand the reaction mechanisms. Here, we provide a critical review of a range of techniques used in the analysis of material surfaces to characterize the chemical, topological, and morphological features relevant to the study of enzymatic biocatalysis, including microscopy techniques, spectroscopic techniques (e.g., X-ray diffraction analysis, Fourier transform infrared attenuated total reflectance spectroscopy, and mass spectrometry detection of analytes associated with degradation). Techniques for evaluation of surface energy and topology in their relevancy for sensitive detection of biological surface modifications are also discussed. In addition, this paper provides an overview of the strengths of these techniques and compares their performance in both sensitivity and throughput, including emerging techniques, which can be useful, particularly for the rapid analysis of the surface properties of polymeric materials in high-throughput screening of candidate biocatalysts. This research serves as a starting point in selecting and applying appropriate methodologies that provide direct evidence to the ongoing biotic degradation of polymeric materials.

Colachis, Matthew↗

Advanced spectroscopic synchrotron techniques to unravel the intrinsic properties of dilute magnetic oxides : the case of Co:ZnO.

The use of synchrotron-based spectroscopy has revolutionized the way we look at matter. X-ray absorption spectroscopy (XAS) using linear and circular polarized light offers a powerful toolbox of element-specific structural, electronic and magnetic probes that is especially well suited for complex materials containing several elements. We use the specific example of Zn{sub 1-x}Co{sub x}O (Co:ZnO) to demonstrate the usefulness of combining these XAS techniques to unravel its intrinsic properties. We demonstrate that as long as phase separation or excessive defect formation is absent, Co:ZnO is paramagnetic. We can establish quantitative thresholds based on four reliable quality indicators using XAS; samples that show ferromagnet-like behaviour fail to meet these quality indicators, and complementary experimental techniques indeed prove phase separation. Careful analysis of XAS spectra is shown to provide quantitative information on the presence and type of dilute secondary phases in a highly sensitive, non-destructive manner.

43 PARTICLE ACCELERATORS↗

Impact of the differential fluence distribution of brachytherapy sources on the spectroscopic dose-rate constant

Purpose: To investigate why dose-rate constants for {sup 125}I and {sup 103}Pd seeds computed using the spectroscopic technique, Λ{sub spec}, differ from those computed with standard Monte Carlo (MC) techniques. A potential cause of these discrepancies is the spectroscopic technique’s use of approximations of the true fluence distribution leaving the source, φ{sub full}. In particular, the fluence distribution used in the spectroscopic technique, φ{sub spec}, approximates the spatial, angular, and energy distributions of φ{sub full}. This work quantified the extent to which each of these approximations affects the accuracy of Λ{sub spec}. Additionally, this study investigated how the simplified water-only model used in the spectroscopic technique impacts the accuracy of Λ{sub spec}. Methods: Dose-rate constants as described in the AAPM TG-43U1 report, Λ{sub full}, were computed with MC simulations using the full source geometry for each of 14 different {sup 125}I and 6 different {sup 103}Pd source models. In addition, the spectrum emitted along the perpendicular bisector of each source was simulated in vacuum using the full source model and used to compute Λ{sub spec}. Λ{sub spec} was compared to Λ{sub full} to verify the discrepancy reported by Rodriguez and Rogers. Using MC simulations, a phase space of the fluence leaving the encapsulation of each full source model was created. The spatial and angular distributions of φ{sub full} were extracted from the phase spaces and were qualitatively compared to those used by φ{sub spec}. Additionally, each phase space was modified to reflect one of the approximated distributions (spatial, angular, or energy) used by φ{sub spec}. The dose-rate constant resulting from using approximated distribution i, Λ{sub approx,i}, was computed using the modified phase space and compared to Λ{sub full}. For each source, this process was repeated for each approximation in order to determine which approximations used in the spectroscopic technique affect the accuracy of Λ{sub spec}. Results: For all sources studied, the angular and spatial distributions of φ{sub full} were more complex than the distributions used in φ{sub spec}. Differences between Λ{sub spec} and Λ{sub full} ranged from −0.6% to +6.4%, confirming the discrepancies found by Rodriguez and Rogers. The largest contribution to the discrepancy was the assumption of isotropic emission in φ{sub spec}, which caused differences in Λ of up to +5.3% relative to Λ{sub full}. Use of the approximated spatial and energy distributions caused smaller average discrepancies in Λ of −0.4% and +0.1%, respectively. The water-only model introduced an average discrepancy in Λ of −0.4%. Conclusions: The approximations used in φ{sub spec} caused discrepancies between Λ{sub approx,i} and Λ{sub full} of up to 7.8%. With the exception of the energy distribution, the approximations used in φ{sub spec} contributed to this discrepancy for all source models studied. To improve the accuracy of Λ{sub spec}, the spatial and angular distributions of φ{sub full} could be measured, with the measurements replacing the approximated distributions. The methodology used in this work could be used to determine the resolution that such measurements would require by computing the dose-rate constants from phase spaces modified to reflect φ{sub full} binned at different spatial and angular resolutions.

07 ISOTOPE AND RADIATION SOURCES↗

A COMPARISON OF GALAXY COUNTING TECHNIQUES IN SPECTROSCOPICALLY UNDERSAMPLED REGIONS

Accurate measures of galactic overdensities are invaluable for precision cosmology. Obtaining these measurements is complicated when members of one’s galaxy sample lack radial depths, most commonly derived via spectroscopic redshifts. In this paper, we utilize the Sloan Digital Sky Survey’s Main Galaxy Sample to compare seven methods of counting galaxies in cells when many of those galaxies lack redshifts. These methods fall into three categories: assigning galaxies discrete redshifts, scaling the numbers counted using regions’ spectroscopic completeness properties, and employing probabilistic techniques. We split spectroscopically undersampled regions into three types—those inside the spectroscopic footprint, those outside but adjacent to it, and those distant from it. Through Monte Carlo simulations, we demonstrate that the preferred counting techniques are a function of region type, cell size, and redshift. We conclude by reporting optimal counting strategies under a variety of conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Microwave assisted preparation of Fe{sup 3+} doped {beta}-dicalcium silicate by sol-gel method

Fe{sup 3+} doped and undoped {beta}-dicalcium silicates ({beta}-Ca{sub 2}SiO{sub 4} or {beta}-C{sub 2}S) were prepared by sol-gel method. The gels formed were heated in a microwave oven and subsequently in a muffle furnace. The particle sizes of doped and undoped samples were found to be about 150 nm and 600 nm respectively. The materials were characterized by scanning electron microscopic, powder X-ray diffraction, BET specific area measurements, infrared spectroscopic and Moessbauer spectroscopic techniques. IR spectroscopic studies showed the possibility of distorted tetrahedral symmetry in Fe{sup 3+} doped {beta}-C{sub 2}S. Calorimetric studies have shown that iron doped {beta}-C{sub 2}S is highly reactive. From Moessbauer spectroscopic studies it is found that electronic environment of Fe{sup 3+} in {beta}-C{sub 2}S is changed due to hydration. Degree of hydration calculated from non-equilibrium water content measurements have shown that Fe{sup 3+} doped {beta}-C{sub 2}S hydrates at a much higher rate. Scanning electron microscopic studies have revealed that the hydration products in both the cases are almost identical. Formation and hydration of {beta}-C{sub 2}S in the presence of Fe{sup 3+} have been understood.

36 MATERIALS SCIENCE↗

Versatile Cell Design for Molten Fluoride Salt Spectroscopy: Investigating Metal-Ion Speciation in Molten Fluoride Salts

Fluoride-based molten salts are widely used in industrial applications including aluminum production, thermal energy storage, optical crystal growth, and advanced nuclear reactor designs. Despite the wide range of uses, fundamental understandings of coordination chemistry and methods for probing molten fluorides are scarce, likely due to the difficulty of probing fluoride melts with spectroscopic techniques. Performing spectroscopic measurements of fluoride-based salts is challenging due to the highly corrosive nature of these salts, which can degrade many common optical materials. Here, in this work, we present a versatile optical cell design that enables spectroscopic measurements of corrosive melts. This innovative cell design overcomes the challenges posed by the corrosive nature of the salts, allowing for an accurate and consistent spectroscopic analysis. This work reports temperature-dependent absorption measurements for Co 2+ , Ni 2+ , and Cr 3+ analytes in LiF-NaF-KF eutectic salt (i.e., FLiNaK), which are common corrosion products originating from structural alloys in molten-fluoride handling. Absorption spectra were used to understand interactions of these analytes with FLiNaK, particularly ligand field coordination. The analysis of absorption spectra was complemented by structural analyses using ab initio molecular dynamics (AIMD) simulations, providing deeper insights into the behavior of the analytes in FLiNaK. Our findings indicate that the analytes studied in this work exist in octahedral or near-octahedral coordination states that remain stable across the temperature range of 500–600 °C. This work not only highlights an applied solution to performing optical spectroscopy in corrosive, high-temperature melts but also provides important fundamental insight on coordination behavior of transition-metal species in molten fluorides.

Fluoride salt spectroscopy↗

Electron-density-sensitive Line Ratios of Fe xiii– xvi from Laboratory Sources Compared to CHIANTI

We present electron-density-sensitive line ratios for Fe xiii– xvi measured in the spectral wavelength range of 200–440 Å and an electron density range of (1-4) × 10 13 cm -3 . The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrument was relatively calibrated using spectroscopic techniques in order to improve accuracy. Lastly, the line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting Sub-Micron Space Weathering Effects in Lunar Grains With Synchrotron Infrared Nanospectroscopy

Space weathering processes induce changes to the physical, chemical, and optical properties of space-exposed soil grains. For the Moon, space weathering causes reddening, darkening, and diminished contrast in reflectance spectra over visible and near-infrared wavelengths. The physical and chemical changes responsible for these optical effects occur on scales below the diffraction limit of traditional far-field spectroscopic techniques. Recently developed super-resolution spectroscopic techniques provide an opportunity to understand better the optical effects of space weathering on the sub-micrometer length scale. This paper uses synchrotron infrared nanospectroscopy to examine depth-profile samples from two mature lunar soils in the mid-infrared, 1,500 –700 cm -1 (6.7–14.3 μm). Overall, our findings are broadly consistent with prior bulk observations and theoretical models of space weathered spectra of lunar materials. These results provide a direct spatial link between the physical/chemical changes in space-exposed grain surfaces and spectral changes of space weathered bodies.

79 ASTRONOMY AND ASTROPHYSICS↗

A modular reactor design for in situ synchrotron x-ray investigation of atomic layer deposition processes

Synchrotron characterization techniques provide some of the most powerful tools for the study of film structure and chemistry. The brilliance and tunability of the Advanced Photon Source allow access to scattering and spectroscopic techniques unavailable with in-house laboratory setups and provide the opportunity to probe various atomic layer deposition (ALD) processes in situ starting at the very first deposition cycle. Here, we present the design and implementation of a portable ALD instrument which possesses a modular reactor scheme that enables simple experimental switchover between various beamlines and characterization techniques. As first examples, we present in situ results for (1) X-ray surface scattering and reflectivity measurements of epitaxial ZnO ALD on sapphire, (2) grazing-incidence small angle scattering of MnO nucleation on silicon, and (3) grazing-incidence X-ray absorption spectroscopy of nucleation-regime Er{sub 2}O{sub 3} ALD on amorphous ALD alumina and single crystalline sapphire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geochemical, mineralogical and microbiological characteristics of sediment from a naturally reduced zone in a uranium-contaminated aquifer

Localized zones or lenses of naturally reduced sediments have the potential to play a significant role in the fate and transport of redox-sensitive metals and metalloids in aquifers. To assess the mineralogy, microbiology and redox processes that occur in these zones, several cores from a region of naturally occurring reducing conditions in a U-contaminated aquifer (Rifle, CO) were examined. Sediment samples from a transect of cores ranging from oxic/suboxic Rifle aquifer sediment to naturally reduced sediment were analyzed for U and Fe content, oxidation state, and mineralogy; reduced S phases; and solid-phase organic C content using a suite of analytical and spectroscopic techniques on bulk sediment and size fractions. Solid-phase U concentrations were higher in the naturally reduced zone, with a high proportion of the U present as U(IV). The sediments were also elevated in reduced S phases and Fe(II), indicating it is very likely that U(VI), Fe(III), and SO 4 reduction has occurred or is occurring in the sediment. The microbial community was assessed using lipid- and DNA-based techniques, and statistical redundancy analysis was performed to determine correlations between the microbial community and the geochemistry. Increased concentrations of solid-phase organic C and biomass in the naturally reduced sediment suggests that natural bioreduction is stimulated by a zone of increased organic C concentration associated with fine-grained material and lower permeability to groundwater flow. Characterization of the naturally bioreduced sediment provides an understanding of the natural processes that occur in the sediment under reducing conditions and how they may impact natural attenuation of radionuclides and other redox sensitive materials. Results also suggest the importance of recalcitrant organic C for maintaining reducing conditions and U immobilization.

54 ENVIRONMENTAL SCIENCES↗

Comparison of atmospheric parameters determined from spectroscopy and photometry for DA white dwarfs in the Sloan Digital Sky Survey

We present a comparative analysis of atmospheric parameters obtained with the so-called photometric and spectroscopic techniques. Photometric and spectroscopic data for 1360 DA white dwarfs from the Sloan Digital Sky Survey (SDSS) are used, as well as spectroscopic data from the Villanova White Dwarf Catalog. We first test the calibration of the ugriz photometric system by using model atmosphere fits to observed data. Our photometric analysis indicates that the ugriz photometry appears well calibrated when the SDSS to AB{sub 95} zeropoint corrections are applied. The spectroscopic analysis of the same data set reveals that the so-called high-log g problem can be solved by applying published correction functions that take into account three-dimensional hydrodynamical effects. However, a comparison between the SDSS and the White Dwarf Catalog spectra also suggests that the SDSS spectra still suffer from a small calibration problem. We then compare the atmospheric parameters obtained from both fitting techniques and show that the photometric temperatures are systematically lower than those obtained from spectroscopic data. This systematic offset may be linked to the hydrogen line profiles used in the model atmospheres. We finally present the results of an analysis aimed at measuring surface gravities using photometric data only.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic nanoparticles for medical applications: Progress and challenges

Magnetic nanoparticles present unique properties that make them suitable for applications in biomedical field such as magnetic resonance imaging (MRI), hyperthermia and drug delivery systems. Magnetic hyperthermia involves heating the cancer cells by using magnetic particles exposed to an alternating magnetic field. The cell temperature increases due to the thermal propagation of the heat induced by the nanoparticles into the affected region. In order to increase the effectiveness of the treatment hyperthermia can be combined with drug delivery techniques. As a spectroscopic technique MRI is used in medicine for the imaging of tissues especially the soft ones and diagnosing malignant or benign tumors. For this purpose Zn{sub x}Co{sub 1−x}Fe{sub 2}O{sub 4} ferrite nanoparticles with x between 0 and 1 have been prepared by co-precipitation method. The cristallite size was determined by X-ray diffraction, while the transmission electron microscopy illustrates the spherical shape of the nanoparticles. Magnetic characterizations of the nanoparticles were carried out at room temperature by using a vibrating sample magnetometer. The specific absorption rate (SAR) was measured by calorimetric method at different frequencies and it has been observed that this value depends on the chemical formula, the applied magnetic fields and the frequency. The study consists of evaluating the images, obtained from an MRI facility, when the nanoparticles are dispersed in agar phantoms compared with the enhanced ones when Omniscan was used as contrast agent. Layer-by-layer technique was used to achieve the necessary requirement of biocompatibility. The surface of the magnetic nanoparticles was modified by coating it with oppositely charged polyelectrolites, making it possible for the binding of a specific drug.

60 APPLIED LIFE SCIENCES↗

Spectroscopic Characterization of Actinide Materials

Advanced spectroscopic techniques provide new and unique tools for unraveling the nature of the electronic structure of actinide materials. Inelastic neutron scattering experiments that address temporal aspects of lattice and magnetic fluctuations, probe electromagnetic multipole interactions and the coupling between electronic and vibrational degrees of freedom. Nuclear magnetic resonance clearly demonstrates different magnetic ground states at low temperature. Photoemission spectroscopies provide information on the occupied part of the electron density of states and have been used to investigate the momentum-resolved electronic structure and the topology of the Fermi surface in a variety of actinide compounds. Furthermore, x-ray absorption and electron energy-loss spectroscopies have been used to probe the relativistic nature, the occupation number, and the degree of localization of 5f electrons across the actinide series. More recently, element and edge-specific resonant and non-resonant inelastic x-ray scattering experiments have provided the opportunity of measuring elementary electronic excitations with higher resolution than traditional absorption techniques. Here, we will discuss the results obtained by most of these different spectroscopic techniques in studying the electronic and magnetic properties of selected actinide compounds, chosen as typical examples of systems with 5f electrons having an itinerant or a localized character, or lying near the localization-delocalization boundary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗