Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stark effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Carrier Lifetime Control Through the Quantum Confined Stark Effect

This study explores how the quantum confined Stark effect (QCSE) influences minority carrier lifetimes in III-N quantum wells (QWs) by varying the well width. It is found that increasing QW width from zero (bulk material) increases radiative lifetime due to charge separation until charge screening effects reduce and rectify the QCSE for large well widths.

Loveless, James Terrell [Sandia National Laborator↗

Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-point motional Stark effect diagnostic for Madison Symmetric Torus

A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views - on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radius measurement than with the on-axis one only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR

A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1–3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stark effect in ensembles of polar (0001) Al{sub 0.5}Ga{sub 0.5}N/GaN quantum dots and comparison with semipolar (11−22) ones

This work presents a continuous-wave photoluminescence study of Al{sub 0.5}Ga{sub 0.5}N/GaN quantum dots grown by ammonia-assisted molecular beam epitaxy on sapphire, either on the wurtzite polar (0001) or the semipolar (11−22) plane. Due to interface polarization discontinuities, the polar dots are strongly red-shifted by the Stark effect and emit in the visible range. Carrier injection screening of the polarization charges has been studied. A model relying on average dot heights and dot height variances, as measured by transmission electron microscopy, is proposed. It can account for the injection dependent luminescence energies and efficiencies. The electric field discontinuity deduced from the fittings is in good agreement with theoretical expectations for our barrier composition. On the contrary, semipolar quantum dot ensembles always emit above the gap of GaN strained to Al{sub 0.5}Ga{sub 0.5}N. Their luminescence linewidth is significantly lower than that of polar ones, and their energy does not shift with injection. Our study then confirms the expected strong decrease of the Stark effect for (11−22) grown (Al,Ga)N/GaN heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical stark effect in the 2-photon spectrum of NO

A large optical Stark effect has been observed in the two-photon spectrum X(2)Pi yields A(2)Sigma(+)_ in NO. It is explained as a near-resonant process in which the upper state of the two-photon transition is perturbed by interactions with higher-lying electronic states coupled by the laser field. A theoretical analysis is presented along with coupling parameters determined from ab initio wave functions. The synthetic spectrum reproduces the major experimental features.

Huo, W. M.↗

Suppression of the quantum-confined Stark effect in Al{sub x}Ga{sub 1−x}N/Al{sub y}Ga{sub 1−y}N corrugated quantum wells

We report comparative studies of 6-nm-thick Al{sub x}Ga{sub 1−x}N/Al{sub y}Ga{sub 1−y}N pyroelectric quantum wells (QWs) grown by plasma-assisted molecular beam epitaxy on c-sapphire substrates with a thick AlN buffer deposited under different growth conditions. The Al-rich growth conditions result in a 2D growth mode and formation of a planar QW, whereas the N-rich conditions lead to a 3D growth mode and formation of a QW corrugated on the size scale of 200–300 nm. Time-resolved photoluminescence (PL) measurements reveal a strong quantum-confined Stark effect in the planar QW, manifested by a long PL lifetime and a red shift of the PL line. In the corrugated QW, the emission line emerges 200 meV higher in energy, the low-temperature PL lifetime is 40 times shorter, and the PL intensity is stronger (∼4 times at 4.5 K and ∼60 times at 300 K). The improved emission properties are explained by suppression of the quantum-confined Stark effect due to the reduction of the built-in electric field within the QW planes, which are not normal to the [0001] direction, enhanced carrier localization, and improved efficiency of light extraction.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Interplay of Bias-Driven Charging and the Vibrational Stark Effect in Molecular Junctions

We observe large, reversible, bias driven changes in the vibrational energies of PCBM based on simultaneous transport and surface-enhanced Raman spectroscopy (SERS) measurements on PCBM-gold junctions. A combination of linear and quadratic shifts in vibrational energies with voltage is analyzed and compared with similar measurements involving C-60-gold junctions. A theoretical model based on density functional theory (DFT) calculations suggests that both a vibrational Stark effect and bias-induced charging of the junction contribute to the shifts in vibrational energies. In the PCBM case, a linear vibrational Stark effect is observed due to the permanent electric dipole moment of PCBM. The vibrational Stark shifts shown here for PCBM junctions are comparable to or larger than the charging effects that dominate in C-60 junctions.

36 MATERIALS SCIENCE↗

The motional Stark effect diagnostic on NSTX

This work describes the implementation and recent results from the motional Stark effect (MSE) collisionally induced fluorescence diagnostic on NSTX. Due to the low magnetic field on NSTX the MSE diagnostic requires a new approach for the viewing optics and spectral filter. This has been accomplished with a novel optical design that reduces the geometric Doppler broadening, and a high throughput, high resolution spectral filter to optimize signal-to-noise ratio. With these improvements the polarization fraction is {approx}30%-40% and, combined with the large throughput, a time resolution of {approx}5 ms. The MSE diagnostic presently has 16 sight lines operating, providing measurements of the magnetic field line pitch from the plasma center to near the outboard edge of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetohydrodynamic interference with the edge pedestal motional Stark effect diagnostic on DIII-D

Accurate measurement of internal magnetic field direction using motional Stark effect (MSE) polarimetry in the edge pedestal is desired for nearly all tokamak scenario work. A newly installed 500 kHz 32-channel digitizer on the MSE diagnostic of DIII-D allows full spectral information of the polarimeter signal to be recovered for the first time. Fourier analysis of this data has revealed magnetohydrodynamic (MHD) fluctuations in the plasma edge pedestal at {rho}{>=} 0.92. By correlating edge localized mode fluctuations seen on lock-in amplifier outputs with MSE spectrograms, it has been shown that edge pedestal tearing mode fluctuations cause interference with MSE second harmonic instrument frequencies. This interference results in unrecoverable errors in the real-time polarization angle measurement that are more than an order of magnitude larger than typical polarimeter uncertainties. These errors can cause as much as a 38% difference in local q. By using a redundant measure of the linear polarization found at the fourth harmonic photo-elastic modulator (PEM) frequency, MHD interference can be avoided. However, because of poorer signal-to-noise the fourth harmonic signal computed polarization angle shows no improvement over the MHD polluted second harmonics. MHD interference could be avoided in future edge pedestal tokamak polarimeters by utilizing PEMs with higher fundamental frequencies and a greater separation between their frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supersymmetric factorization yields exact solutions to the molecular Stark-effect problem for stretched states

By invoking supersymmetry, we found a condition under which the Stark-effect problem for a polar and polarizable molecule subject to nonresonant electric fields becomes exactly solvable for the |J-tilde=m,m> family of stretched states. The analytic expressions for the wave function and eigenenergy and other expectation values allow one to readily reverse-engineer the problem of finding the values of the interaction parameters required for creating quantum states with preordained characteristics. The method also allows the construction of families of isospectral potentials, realizable with combined fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging motional Stark effect measurements at ASDEX Upgrade

This paper presents an overview of results from the Imaging Motional Stark Effect (IMSE) diagnostic obtained during its first measurement campaign at ASDEX Upgrade since installation as a permanent diagnostic. A brief overview of the IMSE technique is given, followed by measurements of a standard H-mode discharge, which are compared to equilibrium reconstructions showing good agreement where expected. The development of special discharges for the calibration of pitch angle is reported and safety factor profile changes during sawteeth crashes are shown, which can be resolved to a few percent due to the high sensitivity at good time resolution of the new IMSE system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic calibration of the motional Stark effect diagnostic on Alcator C-Mod

The capability to calibrate diagnostics, such as the Motional Stark Effect (MSE) diagnostic, without using plasma or beam-into-gas discharges will become increasingly important on next step fusion facilities due to machine availability and operational constraints. A robotic calibration system consisting of a motorized three-axis positioning system and a polarization light source capable of generating arbitrary polarization states with a linear polarization angle accuracy of <0.05° has been constructed and has been used to calibrate the MSE diagnostic deployed on Alcator C-Mod. The polarization response of the complex diagnostic is shown to be fully captured using a Fourier expansion of the detector signals in terms of even harmonics of the input polarization angle. The system's high precision robotic control of position and orientation allow it to be used also to calibrate the geometry of the instrument's view. Combined with careful measurements of the narrow bandpass spectral filters, this system fully calibrates the diagnostic without any plasma discharges. The system's high repeatability, flexibility, and speed has been exploited to quantify several systematics in the MSE diagnostic response, providing a more complete understanding of the diagnostic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Stark effect in the two-photon spectrum of NO

A large optical Stark effect has been observed in the two-photon spectrum X(2)Pi yields A(2)Sigma(+) - in NO. It is explained as a near-resonant process in which the upper state of the two-photon transition is perturbed by interactions with higher-lying electronic states coupled by the laser field. A theoretical analysis is presented along with coupling parameters determined from ab initio wave functions. The synthetic spectrum reproduces the major experimental features.

Huo, W. M.↗