Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized 3 He target and Final State Interactions in SiDIS

Jefferson Lab is starting a wide experimental program aimed at studying the neutron’s structure, with a great emphasis on the extraction of the parton transverse-momentum distributions (TMDs). To this end, Semi-inclusive deep-inelastic scattering (SiDIS) experiments on polarized $^3$He will be carried out, providing, together with proton and deuteron data, a sound flavor decomposition of the TMDs. Here, given the expected high statistical accuracy, it is crucial to disentangle nuclear and partonic degrees of freedom to get an accurate theoretical description of both initial and final states. In this contribution, a preliminary study of the Final State Interaction (FSI) in the standard SiDIS, where a pion (or a Kaon) is detected in the final state is presented, in view of constructing a realistic description of the nuclear initial and final states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Muon flux measurements at the davis campus of the sanford underground research facility with the majorana demonstrator veto system

We report the first measurement of the muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 foot level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. Both results are in agreement within statistical accuracy. The measured flux is (4.08+-0.19) x 10 -9 muons/cm/2. We compare our results with previous calculations.

Abgrall, N.↗

Lattice dynamics of high-pressure hydrides studied by inelastic neutron scattering

Due to the small mass and anomalously large neutron scattering cross-section of proton (about 80 barns compared to a few barns for other nuclei), inelastic neutron scattering is considered as one of the most effective tools in studying optical vibrations of hydrogen atoms in metal hydrides. The current review is focused on the binary hydrides of 3d- and 4d-metals of groups VI–VIII, which were produced at high hydrogen pressures of several gigapascals in relatively large quantities of hundreds of mg, quenched to low temperature and studied by INS ex situ at ambient pressure with high statistical accuracy. One of the unusual effects revealed by INS is a strong increase in the strength of the metal-hydrogen interactions with decreasing atomic number of the d-metal accompanied by an increase in the Me-H distance. Based on the available experimental results, the spectra g(E) of the phonon density of states and temperature dependencies CV(T) of the heat capacity at constant volume at T up to 1000 K have been derived in this paper and presented both in the figures and in digital form. This provides the reference data for the theoretical investigations of the crystal structures and compositions of new practically important hydrides giving the opportunity to validate calculation methods by comparing the calculated g(E) and CV(T) with the accurate experimental dependencies for the binary hydrides. Recent INS studies showed [R.A. Klein et al., J. Alloy. Compd. 894 (2022) 162381] that the fingerprints of anomalously short H-H separations of 1.6 Å violating the “2 Å rule” can be easily and unambiguously identified in the complex INS spectra of quaternary hydrides (La,Ce)NiInH 1+x . This makes neutron spectroscopy an attractive means for obtaining valuable data in the search for novel hydrides with a record high hydrogen capacity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamic Stochastic Superresolution of sparsely observed turbulent systems

Real-time capture of the relevant features of the unresolved turbulent dynamics of complex natural systems from sparse noisy observations and imperfect models is a notoriously difficult problem. The resulting lack of observational resolution and statistical accuracy in estimating the important turbulent processes, which intermittently send significant energy to the large-scale fluctuations, hinders efficient parameterization and real-time prediction using discretized PDE models. This issue is particularly subtle and important when dealing with turbulent geophysical systems with an vast range of interacting spatio-temporal scales and rough energy spectra near the mesh scale of numerical models. Here, we introduce and study a suite of general Dynamic Stochastic Superresolution (DSS) algorithms and show that, by appropriately filtering sparse regular observations with the help of cheap stochastic exactly solvable models, one can derive stochastically ‘superresolved’ velocity fields and gain insight into the important characteristics of the unresolved dynamics, including the detection of the so-called black swans. The DSS algorithms operate in Fourier domain and exploit the fact that the coarse observation network aliases high-wavenumber information into the resolved waveband. It is shown that these cheap algorithms are robust and have significant skill on a test bed of turbulent solutions from realistic nonlinear turbulent spatially extended systems in the presence of a significant model error. In particular, the DSS algorithms are capable of successfully capturing time-localized extreme events in the unresolved modes, and they provide good and robust skill for recovery of the unresolved processes in terms of pattern correlation. Moreover, we show that DSS improves the skill for recovering the primary modes associated with the sparse observation mesh which is equally important in applications. The skill of the various DSS algorithms depends on the energy spectrum of the turbulent signal and the observation time relative to the decorrelation time of the turbulence at a given spatial scale in a fashion elucidated here. The DSS technique exploiting a simple Gaussian closure of the nonlinear stochastic forecast model emerges as the most suitable trade-off between the superresolution skill and computational complexity associated with estimating the cross-correlations between the aliasing modes of the sparsely observed turbulent signal. Such techniques offer a promising and efficient approach to constraining unresolved turbulent fluxes through stochastic superparameterization and a subsequent improvement in coarse-grained filtering and prediction of the next generation atmosphere–ocean system (AOS) models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining reference standard strength for neutron-irradiated reduced activation ferritic/martensitic steel F82H by Bayesian method

The deterministic approach widely adopted in the design of structural components relies on systematically defined design limits using empirically determined safety factors. However, this approach is not always appropriate because structures are subjected to a variety of loads in the practical environment, which may result in excessively conservative design limits. In recent years, a more rigorous probabilistic approach that incorporates material strength distributions has become an important solution. In the probabilistic approach, the probability density functions of material strength properties underpin the design criteria. Here, the objective of this study is to identify the density distribution functions that best describe tensile properties of irradiated F82H to define a reference strength for DEMO design. Due to the limited number of existing data, this study specifically employs a Bayesian prediction method based on Monte Carlo simulations to determine a material reference value with statistical reliability and to investigate its effectiveness. For example, the dependence of tensile properties of 300 °C irradiated materials on irradiation damage and the range predicted by 95% Bayesian estimation was evaluated. As a statistical model for the dose dependence of statistical parameters, the normal distribution exhibited a better fit for 0.2% proof strength and tensile strength, whereas the distribution of total elongation data gave comparable reference values for both the normal and Weibull distribution models. Both models gave comparable criteria for the distribution of total elongation data. The Weibull model also gave better results for uniform elongation. The function best describing the model was a logarithmic law for both 0.2% proof strength and tensile strength, while a power law for both total and uniform elongation, which allowed for more comprehensive data prediction of irradiation data with statistical accuracy for DEMO reactor design.

36 MATERIALS SCIENCE↗

The Beam-Beam Counter: A Local Polarimeter at STAR

At the Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider (RHIC) the Beam-Beam Counter (BBC) array for the Solenodial Tracker at RHIC (STAR) is a very versatile tool for polarized proton beam diagnostics. The BBC setup provides an excellent minimum bias trigger; and for hits on the inner annuli of six hexagonal scintillator tiles the BBC coincidence trigger with a suitable algorithm has a quite large single spin analyzing power {approx}8x10{sup -3} for 100 GeV polarized proton -100 GeV polarized proton collisions. The STAR BBC is a very effective local polarimeter at these energies. For 100 GeV p-vector -100 GeV p-vector running in 2006 the BBC measured single spin asymmetries to a statistical accuracy of better than 2% for a data run of 20-30 minutes; and these measurements were quite robust. For fills with a duration of at least six hours these STAR BBC asymmetry measurements were used to study the time dependence of the polarization for 100 GeV proton beams in the RHIC rings. The decrease of the polarization is quite small, <0.01P{sub B} per hour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonance Counters as the Best Tool for the Investigations in Material Science

Sensitivity and resolution play a crucial role when Moessbauer spectroscopy is used in the materials science. Application of resonance counters in Moessbauer spectrometers allows us to increase the parameters mentioned above, and also signal-to-noise ratio considerably. The last one provides diminishing the time needed for obtaining given statistical accuracy. We carried out investigations of development of optimal counters for following isotopes: {sup 57}Fe, {sup 119}Sn, and {sup 151}Eu. Influence of different parameters of resonant radiation converters on experimental results was considered theoretically. Optimization of design has been performed using mathematical modeling based on Monte-Carlo method. Comparison of different types of counters used for resonant detecting was carried out. Results of experimental works on selection of efficient radiation converters are given. Comparison of scintillation and gas resonance counters was carried out. FeAl and FeGe{sub 2} alloys and K{sub 2}MgFe(CN){sub 6} have been used as converters for experiments with {sup 57}Fe-isotope, CaSnO{sub 3} has been used for {sup 119}Sn and Eu{sub 2}O{sub 3} and EuF{sub 3}--for {sup 151}Eu isotope. Gamma-optical scheme for versatile spectrometer, which expands the range of application of resonant detection for other Moessbauer isotopes, was suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Compton radiography of inertial confinement fusion implosions

An important diagnostic tool for inertial confinement fusion will be time-resolved radiographic imaging of the dense cold fuel surrounding the hot spot. The measurement technique is based on point-projection radiography at photon energies from 60 to 200 keV where the Compton effect is the dominant contributor to the opacity of the fuel or pusher. We have successfully applied this novel Compton radiography technique to the study of the final compression of directly driven plastic capsules at the OMEGA facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The radiographs have a spatial and temporal resolution of {approx}10 {mu}m and {approx}10 ps, respectively. A statistical accuracy of {approx}0.5% in transmission per resolution element is achieved, allowing localized measurements of areal mass densities to 7% accuracy. The experimental results show 3D nonuniformities and lower than 1D expected areal densities attributed to drive asymmetries and hydroinstabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoproduction of Mesons off Light Nuclei

During the last few years, a series of experiments has been done at the ELSA accelerator in Bonn with the Crystal Barrel/TAPS setup and at the MAMI accelerator in Mainz with the Crystal Ball/TAPS setup. Photoproduction of light mesons off the deuteron and {sup 3}He-nuclei has been studied in detail. We will report some of the most interesting results.A completely unexpected finding, is the pronounced structure in the excitation function of the {gamma}n {yields} n{eta} reaction around 1 GeV, which has no counterpart for the proton. Recent measurements at GRAAL, Sendai, ELSA [1] and MAMI estimate it's width below 50 MeV, which would be extremely narrow for a nucleon resonance at this excitation energy. In the experiment with the {sup 3}He target, special attention was given to the threshold behavior of the {gamma}He{sup 3} reactions in view of possible indications for the formation of (quasi-)bound {eta}-nucleus states, so-called {eta}-mesic nuclei. A very strong threshold enhancement of coherent {eta}-photoproduction off {sup 3}He was found. In a new experiment, this reaction was measured with much better statistical accuracy compared to an earlier experiment at MAMI-B using the TAPS detector [2].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RBS and PIXE analysis of chlorine contamination in ALD-Grown TiN films on silicon

The performance, strengths and limitations of RBS and PIXE for the characterization of trace amounts of Cl in TiN thin films are critically compared. The chlorine atomic concentration in ALD grown TiN thin films on Si is determined for samples grown at temperatures ranging from 350 Degree-Sign C to 550 Degree-Sign C. We show that routine Rutherford backscattering spectrometry measurements (1.5 MeV He{sup +}) and PIXE measurements (1.5 MeV H{sup +}) on 20 nm thick TiN films allow one to determine the Cl content down to 0.3 at% with an absolute statistical accuracy reaching 0.03 at%. Possible improvements to push the sensitivity limit for both approaches are proposed.

36 MATERIALS SCIENCE↗

Investigation of Compton profiles of molecular methane and ethane

The Compton profiles of methane and ethane molecules have been determined at an incident photon energy of 20 keV based on the third generation synchrotron radiation, and the statistical accuracy of 0.2% is achieved near p{sub z} = 0. The density functional theory with aug-cc-pVTZ basis set was used to calculate the Compton profiles of methane and ethane. The present experimental Compton profiles are in better agreement with the theoretical calculations in the whole p{sub z} region than the previous experimental results, which indicates that the present experimental Compton profiles are accurate enough to serve as the benchmark data for methane and ethane molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron momentum spectroscopy of dimethyl ether taking account of nuclear dynamics in the electronic ground state

The influence of nuclear dynamics in the electronic ground state on the (e,2e) momentum profiles of dimethyl ether has been analyzed using the harmonic analytical quantum mechanical and Born-Oppenheimer molecular dynamics approaches. In spite of fundamental methodological differences, results obtained with both approaches consistently demonstrate that molecular vibrations in the electronic ground state have a most appreciable influence on the momentum profiles associated to the 2b{sub 1}, 6a{sub 1}, 4b{sub 2}, and 1a{sub 2} orbitals. Taking this influence into account considerably improves the agreement between theoretical and newly obtained experimental momentum profiles, with improved statistical accuracy. Both approaches point out in particular the most appreciable role which is played by a few specific molecular vibrations of A{sub 1}, B{sub 1}, and B{sub 2} symmetries, which correspond to C–H stretching and H–C–H bending modes. In line with the Herzberg-Teller principle, the influence of these molecular vibrations on the computed momentum profiles can be unraveled from considerations on the symmetry characteristics of orbitals and their energy spacing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr 3 (Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89 Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89 Zr through an (n, 2n) reaction on 90 Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Radiation Transport Due to Activated Coolant in the ITER Neutral Beam Injection Cell

Detailed spatial distributions of the biological dose rate due to a variety of sources are required for the design of the ITER tokamak facility to ensure that all radiological zoning limits are met. During operation, water in the Integrated loop of Blanket, Edge-localized mode and vertical stabilization coils, and Divertor (IBED) cooling system will be activated by plasma neutrons and will flow out of the bioshield through a complex system of pipes and heat exchangers. This paper discusses the methods used to characterize the biological dose rate outside the tokamak complex due to 16 N gamma radiation emitted by the activated coolant in the Neutral Beam Injection (NBI) cell of the tokamak building. Activated coolant will enter the NBI cell through the IBED Primary Heat Transfer System (PHTS), and the NBI PHTS will also become activated due to radiation streaming through the NBI system. To properly characterize these gamma sources, the production of 16 N, the decay of 16 N, and the flow of activated water through the coolant loops were modeled. The impact of conservative approximations on the solution was also examined. Once the source due to activated coolant was calculated, the resulting biological dose rate outside the north wall of the NBI cell was determined through the use of sophisticated variance reduction techniques. The AutomateD VAriaNce reducTion Generator (ADVANTG) software implements methods developed specifically to provide highly effective variance reduction for complex radiation transport simulations such as those encountered with ITER. Using ADVANTG with the Monte Carlo N-particle (MCNP) radiation transport code, radiation responses were calculated on a fine spatial mesh with a high degree of statistical accuracy. In conclusion, advanced visualization tools were also developed and used to determine pipe cell connectivity, to facilitate model checking, and to post-process the transport simulation results.

59 BASIC BIOLOGICAL SCIENCES↗

MOIRCS DEEP SURVEY. IV. EVOLUTION OF GALAXY STELLAR MASS FUNCTION BACK TO z {approx} 3

We use very deep near-infrared (NIR) imaging data obtained in MOIRCS Deep Survey (MODS) to investigate the evolution of the galaxy stellar mass function back to z {approx} 3. The MODS data reach J = 24.2, H = 23.1, and K = 23.1 (5{sigma}, Vega magnitude) over 103 arcmin{sup 2} (wide) and J = 25.1, H = 23.7, and K = 24.1 over 28 arcmin{sup 2} (deep) in the GOODS-North region. The wide and very deep NIR data allow us to measure the number density of galaxies down to low stellar mass (10{sup 9}-10{sup 10} M{sub sun}) even at high redshift with high statistical accuracy. The normalization of the mass function decreases with redshift, and the integrated stellar mass density becomes {approx}8%-18% of the local value at z {approx} 2 and {approx}4%-9% at z {approx} 3, which are consistent with results of previous studies in general fields. Furthermore, we found that the low-mass slope becomes steeper with redshift from {alpha} {approx} -1.3 at z {approx} 1 to {alpha} {approx} -1.6 at z {approx} 3 and that the evolution of the number density of low-mass (10{sup 9}-10{sup 10} M{sub sun}) galaxies is weaker than that of M* ({approx}10{sup 11} M{sub sun}) galaxies. This indicates that the contribution of low-mass galaxies to the total stellar mass density has been significant at high redshift. The steepening of the low-mass slope with redshift is an opposite trend expected from the stellar mass dependence of the specific star formation rate reported in previous studies. The present result suggests that the hierarchical merging process overwhelmed the effect of the stellar mass growth by star formation and was very important for the stellar mass assembly of these galaxies at 1 {approx}< z {approx}< 3.

79 ASTRONOMY AND ASTROPHYSICS↗