Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structurally Insulated Panels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Manufacture, and Experimental Serviceability Validation of ITER Blanket Components

In 2014, the Russian Federation and the ITER International Organization signed two Procurement Arrangements (PAs) for ITER blanket components: 1.6.P1ARF.01 “Blanket First Wall” of February 14, 2014, and 1.6.P3.RF.01 “Blanket Module Connections” of December 19, 2014. The first PA stipulates development, manufacture, testing, and delivery to the ITER site of 179 Enhanced Heat Flux (EHF) First Wall (FW) Panels intended for withstanding the heat flux from the plasma up to 4.7MW/m{sup 2}. Two Russian institutions, NIIEFA (Efremov Institute) and NIKIET, are responsible for the implementation of this PA. NIIEFA manufactures plasma-facing components (PFCs) of the EHF FW panels and performs the final assembly and testing of the panels, and NIKIET manufactures FW beam structures, load-bearing structures of PFCs, and all elements of the panel attachment system. As for the second PA, NIKIET is the sole official supplier of flexible blanket supports, electrical insulation key pads (EIKPs), and blanket module/vacuum vessel electrical connectors. Joint activities of NIKIET and NIIEFA for implementing PA 1.6.P1ARF.01 are briefly described, and information on implementation of PA 1.6.P3.RF.01 is given. Results of the engineering design and research efforts in the scope of the above PAs in 2015–2016 are reported, and results of developing the technology for manufacturing ITER blanket components are presented.

42 ENGINEERING↗

Ultraviolet-light-emitting AlN:Gd thin-film electroluminescence device using an energy transfer from Gd{sup 3+} ions to N{sub 2} molecules

An ultraviolet (UV)-light-emitting AlN:Gd thin-film electroluminescence device (TFELD) was demonstrated for application to flat-panel lighting. AlN:Gd thin films were deposited by rf magnetron sputtering at 200 deg. C and applied to an ac-voltage-driven TFELD with a double-insulating structure as an emission layer. UV-light emission was observed over a threshold voltage of 270 V for a 5 kHz sinusoidal ac voltage. Electroluminescence (EL) spectra were compared with photoluminescence and cathodoluminescence spectra of AlN:Gd originating from Gd{sup 3+} {sup 6}P{sub j}->{sup 8}S{sub 7/2} transitions and with an emission spectrum of the second positive system (C{sup 3}PI{sub u}->B{sup 3}PI{sub g}) of N{sub 2} molecules. As a result, an energy transfer from Gd{sup 3+} {sup 6}P{sub j}->{sup 8}S{sub 7/2} to N{sub 2}C{sup 3}PI{sub u}->B{sup 3}PI{sub g} is discussed as a likely mechanism for the UV EL. Finally, a preliminary result, associated with the conversion from UV light into blue-green light via a phosphor, is demonstrated for the color tunability of the TFELD.

36 MATERIALS SCIENCE↗

Tailoring biogenic straw insulation from additive manufacturing

In the pursuit of carbon-storing materials that could help accomplish high levels of building sustainability, wheat straw has emerged as a promising alternative to fossil fuel-based building materials. Straw is 100% biodegradable and abundant agricultural waste used in the construction 400 years ago, and it has been reported to have the lowest embodied carbon when measured against other typical insulating materials. Here, in this study, we report additive manufacturing of carbon-sequestration insulation panel materials by upcycling cellulose fibrils from wheat straw. Cellulose obtained from alkaline and 2,2,6,6-tetramethylpiperidine-1-oxyl radical-mediated oxidation shows thermal conductivity of 0.036 W m -1 K -1 , alongside elastic and flexural modulus of 900 MPa and 502 MPa, respectively. In addition, an in-situ hydrophobic treatment in the cellulose-based insulation panels is achieved with an average water contact angle of 133.7° Furthermore, the extrusion-based additive manufacturing of a 3D-printable ink obtained by mixing the cellulose and silica aerogel precursor is accomplished, with the printed material exhibiting structural integrity, thus showing great potential towards the development of state-of-the-art, sustainable materials for carbon-sequestration building applications.

36 MATERIALS SCIENCE↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exterior Insulation Systems Containing Vacuum Insulation Panels Tested Using a Heat Flux Meter Apparatus

A proposed wall system that will provide a high thermal resistance in a relatively thin profile incorporates vacuum insulation panels (VIP) enclosed within closed-cell insulating foam. In addition to providing some additional thermal resistance, the foam protects the vacuum panels during construction and provides a surface appropriate for an adhesive joint on both sides of the foam-VIP unit. Multiple configurations of the composite structure were considered and experimental measurements were sought to provide more information in the final selection. Small sub-sections of each candidate arrangement were prepared and tested in a special-purpose heat flux meter apparatus. Those measurements are described here, along with additional modeling efforts based on these smaller-scale measurements. The focus of the tests reported here is to investigate the impact of vacuum panel size, the type of foam used to encase the vacuum panels, the thickness and shape of the foam sections between panels, and possible adhesive effects. A new procedure was developed to map the heat flux meter measurement results onto full-scale wall designs to predict the system thermal performance. Several potential arrangements of the foam-VIP unit were also evaluated using a finite-difference methodology. The report also evaluates procedures for testing VIPs in a heat flux meter apparatus, and makes some recommendations.

Childs, Kenneth W.↗

Affordable Solid Panel “Perfect Wall” System

This report, Affordable Solid Panel “Perfect Wall” System , reviews and analyzes a novel building assembly—which features an innovative large format Solid Panel Structure and utilizes the “perfect wall” concept of having high-performance moisture and thermal control layers on the exterior of the structural components.

14 SOLAR ENERGY↗

Bioinspired Dry‐Steam Superinsulation Straw Foam

Abstract Cellulosic materials offer sustainable advantages for building energy conservation. However, their development has been hindered by reduced thermal performance, often caused by structural collapse during the transition from solution to solid. Inspired by natural goose down, a bio‐based, lightweight insulation foam derived from agricultural waste straw is presented. Through in situ synthesis, bio‐silica fibers with branched structures capable of supporting hollow silica microspheres are fabricated. After steam‐mediated processing, the resulting foam exhibit low density (95 mg cm − 3 ), high porosity (95.5%), low thermal conductivity (0.03 ± 0.003 W mK −1 ), and a cyclic compressive strength of 90 kPa at 50% strain. Owing to the synergistic microstructure formed by branched bio‐fibers and hollow silica spheres, the bio‐silica foam exhibit outstanding thermal insulation performance relative to other bio‐based foams prepared by ambient drying. A passivated insulation panel is further developed by incorporating this material as the core component, achieving a thermal conductivity of 0.0275 W mk −1 and flexural strength of 6.85 MPa. The panel demonstrated durability with stable thermal performance throughout a 60‐day outdoor test. Moreover, the bio‐silica foam shows a carbon footprint of 7.50 kgCO₂ kg −1 at 70.2 wt.% silica, highlighting its promise as a sustainable insulation solution for green buildings.

Chemistry↗

The Windscale Advanced Gas Cooled Reactor (WAGR) Decommissioning Project A Close Out Report for WAGR Decommissioning Campaigns 1 to 10 - 12474

The reactor core of the Windscale Advanced Gas-Cooled Reactor (WAGR) has been dismantled as part of an ongoing decommissioning project. The WAGR operated until 1981 as a development reactor for the British Commercial Advanced Gas cooled Reactor (CAGR) power programme. Decommissioning began in 1982 with the removal of fuel from the reactor core which was completed in 1983. Subsequently, a significant amount of engineering work was carried out, including removal of equipment external to the reactor and initial manual dismantling operations at the top of the reactor, in preparation for the removal of the reactor core itself. Modification of the facility structure and construction of the waste packaging plant served to provide a waste route for the reactor components. The reactor core was dismantled on a 'top-down' basis in a series of 'campaigns' related to discrete reactor components. This report describes the facility, the modifications undertaken to facilitate its decommissioning and the strategies employed to recognise the successful decommissioning of the reactor. Early decommissioning tasks at the top of the reactor were undertaken manually but the main of the decommissioning tasks were carried remotely, with deployment systems comprising of little more than crane like devices, intelligently interfaced into the existing structure. The tooling deployed from the 3 tonne capacity (3te) hoist consisted either purely mechanical devices or those being electrically controlled from a 'push-button' panel positioned at the operator control stations, there was no degree of autonomy in the 3te hoist or any of the tools deployed from it. Whilst the ATC was able to provide some tele-robotic capabilities these were very limited and required a good degree of driver input which due to the operating philosophy at WAGR was not utilised. The WAGR box proved a successful waste package, adaptable through the use of waste box furniture specific to the waste-forms generated throughout the various decommissioning campaigns. The use of low force compaction for insulation and soft wastes provided a simple, robust and cost effective solution as did the direct encapsulation of LLW steel components in the later stages of reactor decommissioning. Progress through early campaigns was good, often bettering the baseline schedule, especially when undertaking the repetitive tasks seen during Neutron Shield and Graphite Core decommissioning, once the operators had become experienced with the equipment, though delays became more pronounced, mainly as a result of increased failures due to the age and maintainability of the RDM and associated equipment. Extensive delays came about as a result of the unsupported insulation falling away from the pressure vessel during removal and the inability of the ventilation system to manage the sub micron particulate generated during IPOPI cutting operations, though the in house development of revised and new methodologies ultimately led to the successful completion of PV and I removal. In a programme spanning over 12 years, the decommissioning of the reactor pressure vessel and core led to the production 110 ILW and 75 LLW WAGR boxes, with 20 LLW ISO freight containers of primary reactor wastes, resulting in an overall packaged volume of approximately 2500 cubic metres containing the estimated 460 cubic metres of the reactor structure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building Life-Cycle Analysis with the GREET Building Module: Methodology, Data, and Case Studies

To holistically address building sustainability, Argonne National Laboratory has expanded its Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET) life-cycle model with a new GREET Building Module. This report documents life-cycle analysis (LCA) methodology and foreground data that Argonne National Laboratory compiles and develops to address embodied greenhouse gas (GHG) emissions and energy impacts of a wide range of envelope and structural building materials for new construction and retrofits. The methodology and data form the backbone of the GREET Building Module. This research effort focuses on developing consistent LCA methodology that conforms to building LCA standards such as the EN 15978 to address embodied GHG emissions and energy impacts of building materials/technologies. We document detailed foreground data for selected building materials and building components that are common for building construction. To test the LCA methodology and the GREET Building Module, this report includes case studies of insulation materials and wall panels for residential building retrofit. We have developed a separate document as a User Guide for understanding and applying the GREET Building Module to conduct detailed, process-level LCA of embodied carbon and energy impacts of emerging building materials and technology solutions that of interest to the Building Technologies Office (BTO) of the US Department of Energy, researchers, and industry stakeholders.

42 ENGINEERING↗

Characterization of wood fiber insulation for the development of wood fiber-insulated panels (WIPs) for use in building envelope

Wood fiber insulation (WFI) was studied as an eco-friendly alternative for fossil-based building insulation, focusing on its use in new wood fiber-insulated panels (WIPs). Rigid WFI boards with densities of 110, 140, and 180 kg/m³, including a 140 kg/m³ variant without paraffin wax, were evaluated. Key properties investigated included porosity, water vapor transmission, liquid water adsorption, and thermal conductivity. The porosity ranged between 85 and 92%, primarily influenced by density. Water vapor permeability ranged from 65 to 90 ng·s-1m-1Pa-1, while liquid water absorption was between 2.5 and 20% by volume, influenced by both wax and density. The thermal conductivity coefficient ranged from 0.038 to 0.055 W/(m·K). Bond strength tests with WFI (140 kg/m³ with wax) laminated to various materials using structural adhesives showed tensile perpendicular-to-grain strengths of 10 to 16 kPa and shear strengths of 60 to 90 kPa, with failure only occurring within the WFI. It was concluded that WFI is a promising material for novel WIPs, offering competitive hygrothermal properties and compatibility with structural adhesives. However, its bio-based nature suggests variability and complexity, necessitating further rigorous testing in various climates and in more complex assemblies.

Materials Science↗

Demonstration of self-healing barrier films for vacuum insulation panels

This article presents the demonstration of a rapid self-healing system for barrier films of vacuum insulation panels (VIPs). The proposed self-healing films can improve the durability of VIPs by in-situ remediation of film defects. The self-healing concept has seen limited applications in buildings, and the current work is the first proposed application to VIPs. VIPs can attain an order-of-magnitude lower thermal conductivity than traditional foam and fibrous building insulations. The key to the ultra-low thermal conductivity of VIPs is an evacuated core that is fully-encapsulated within impermeable barrier films. Evacuation of the core eliminates the gas conductivity, which is the dominant contributor to heat transfer in traditional insulation materials. Hence, the integrity of the VIP barrier films is critical. The proposed self-healing system can seal accidental cuts and punctures to the barrier films to maintain their impermeability and, hence, the low conductivity of VIPs. Here, the proof-of-principle of a two-part chemical reaction-based self-healing system is presented, including the evaluations of reaction kinetics using chemical-structure analysis and time-dependent viscosity change, and demonstration of self-healing performance via puncture tests in a vacuum pump apparatus. Multiple chemical combinations of epoxies and curing agents were investigated with respect to reaction kinetics and chemical stability. Epon 8111 as an epoxy and poly(ethyelenimine) (PEI) as a curing agent were identified as the optimum chemicals with a curing time of 22 s as evaluated by an agitating stirrer experiment. 1H nuclear magnetic resonance (NMR) spectra analysis identified the curing reaction occurring mainly via the Michael amine-acrylate addition. The measured time-dependent viscosity change of diluted Epon 8111 and PEI solutions agreed well with a gelation model of typical epoxy curing kinetics, which predicted a very fast reaction rate for the undiluted chemicals. Lastly, puncture tests of small-scale film specimens containing Epon 8111 and PEI in a vacuum pump system demonstrated that the self-healing reaction happens very rapidly and the healed films maintain the system vacuum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cost Efficient and Highly Weather-Resistant Solar Panel Backsheet Produced through Continuous Co-Extrusion Processing

The efficient generation and delivery of ‘clean energy” through photovoltaic (PV) technology relies heavily on the cost, performance and reliability of solar panels, along with the individual components used in assembly of those panels. In order to continue towards the Department of Energy’s (DOE) goals of driving costs down, the lifetime of high-output power generation equipment (i.e. solar modules) must be extended to reduce costs associated with power output degradation and replacement of failed or degraded panels. One of the major sources of module failures in the past 30 years has been the failure of the solar panel backsheet. Failure of this component causes severe output losses due to oxidation and yellowing of the module while creating safety concerns as the major electrical insulation of the module is compromised. Tomark-Worthen LLC was formed in 2012 with the goal of designing and manufacturing novel PV backsheets and encapsulants that would be produced in the United States of America and exceed expectations of domestic and international module producers. These backsheets would improve upon known backsheet design failures (i.e. Isovoltaic’s AAA backsheet) and create domestic manufacturing jobs in the PV sector. This goal became a reality with a first-generation product in 2018 and now, with the support of the DOE, Tomark-Worthen has launched a second-generation product known as PhotoMark® Reflections™ 205-3 and 360-3. This 2+ year effort began in late 2017 with a screening of potential polymeric materials and backsheet structural designs. Performance evaluations of each material provided the necessary data needed to select the proper material combinations and move forward into the design of the manufacturing process. These decisions were made by teaming with a local university, well-respected government laboratories, and private research organizations who provided the tools necessary to predict long-term performance of these materials in much shorter periods of time. Once the go/no-go criteria were met at the mid-point of the project, the effort transitioned to predicting 30+ year performance, achieving certifications, and improving manufacturing efficiencies designed to lower costs in order to be competitive in a cost-driven market. Major project accomplishments include recognition of the new backsheet by Underwriters Laboratories (UL) and international certification for 1000V and 1500V modules by TUV Sud. Both 1000V and 1500V products have been proven on several module manufacturing lines and initial customer orders have been received by both domestic and international module producers. Accelerated exposure testing has shown that the performance of this backsheet exceeds the prior polyamide-based backsheet known to fail in the field. Cost-models and initial customer orders have shown the ability to produce this backsheet at a cost acceptable to many domestic manufacturers, while International costs for standard backsheet remains extremely low. Tomark-Worthen remains one of the only U.S. companies manufacturing backsheet domestically and this has drawn interest from many domestic module manufacturers looking to improve their material supply logistics by avoiding long lead times and custom’s headaches while avoiding current tariffs on Chinese-made components. Along with the launch of a new PV backsheet, this project has provided a critical deliverable to the PV R&D community. This deliverable is the knowledge that not all polyamide-containing backsheets are doomed to failure as the earlier versions did. There has been a fear amongst the PV community to consider these materials due to the failure of one design. This effort has brought a new level of interest to the scientific community as it has been shown that polyamides can be used successfully in a well-designed backsheet. As we move forward from this project, we are excited to see how backsheet technology and manufacturing in the U.S. will continue to progress and grow.

14 SOLAR ENERGY↗

Using Retrofit Nail Base Panels to Expand the Market for Wall Upgrades

This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York

This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.

33 ADVANCED PROPULSION SYSTEMS↗

Structure and properties of α-NaFeO{sub 2}-type ternary sodium iridates

The synthesis, structure, and elementary magnetic and electronic properties are reported for layered compounds of the type Na{sub 3−x}MIr{sub 2}O{sub 6} and Na{sub 3−x}M{sub 2}IrO{sub 6}, where M is a transition metal from the 3d series (M=Zn, Cu, Ni, Co, Fe and Mn). The rhombohedral structures, in space group R−3m, were determined by refinement of neutron and synchrotron powder diffraction data. No clear evidence for long range 2:1 or 1:2 honeycomb-like M/Ir ordering was found in the neutron powder diffraction patterns except in the case of M=Zn, and thus in general the compounds are best designated as sodium deficient α-NaFeO{sub 2}-type phases with formulas Na{sub 1−x}M{sub 1/3}Ir{sub 2/3}O{sub 2} or Na{sub 1−x}M{sub 2/3}Ir{sub 1/3}O{sub 2}. Synchrotron powder diffraction patterns indicate that several of the compounds likely have honeycomb in-plane metal–iridium ordering with disordered stacking of the layers. All the compounds are sodium deficient under our synthetic conditions and are black and insulating. Weiss constants derived from magnetic susceptibility measurements indicate that Na{sub 0.62}Mn{sub 0.61}Ir{sub 0.39}O{sub 2}, Na{sub 0.80}Fe{sub 2/3}Ir{sub 1/3}O{sub 2}, Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2}, Na{sub 0.86}Cu{sub 1/3}Ir{sub 2/3}O{sub 2}, and Na{sub 0.89}Zn{sub 1/3}Ir{sub 2/3}O{sub 2} display dominant antiferromagnetic interactions. For Na{sub 0.90}Co{sub 1/3}Ir{sub 2/3}O{sub 2} the dominant magnetic interactions at low temperature are ferromagnetic while at high temperatures they are antiferromagnetic; there is also a change in the effective moment. Low temperature specific heat measurements (to 2 K) on Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2} indicate the presence of a broad magnetic ordering transition. X-ray absorption spectroscopy shows that iridium is at or close to the 4+ oxidation state in all compounds. {sup 23}Na nuclear magnetic resonance measurements comparing Na{sub 2}IrO{sub 3} to Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2} and Na{sub 0.89}Zn{sub 1/3}Ir{sub 2/3}O{sub 2} provide strong indications that the electron spins are short-range ordered in the latter two materials. Na{sub 0.62}Mn{sub 0.61}Ir{sub 0.39}O{sub 2}, Na{sub 0.80}Fe{sub 2/3}Ir{sub 1/3}O{sub 2}, Na{sub 0.90}Co{sub 1/3}Ir{sub 2/3}O{sub 2}, Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2}, Na{sub 0.86}Cu{sub 1/3}Ir{sub 2/3}O{sub 2} and Na{sub 0.89}Zn{sub 1/3}Ir{sub 2/3}O{sub 2} are spin glasses. (CSD-numbers: Na{sub 0.62}Mn{sub 0.61}Ir{sub 0.39}O{sub 2}: 426657, Na{sub 0.80}Fe{sub 2/3}Ir{sub 1/3}O{sub 2}: 426659, Na{sub 0.90}Co{sub 1/3}Ir{sub 2/3}O{sub 2}: 426658, Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2}: 426656, Na{sub 0.86}Cu{sub 1/3}Ir{sub 2/3}O{sub 2}: 426655, and Na{sub 2.8}ZnIr{sub 2}O{sub 6}: 426660.) - Graphical abstract: Diffraction patterns of Na{sub 0.92}Ni{sub 1/3}Ir{sub 2/3}O{sub 2}, Na{sub 0.86}Cu{sub 1/3}Ir{sub 2/3}O{sub 2} and Na{sub 0.89}Zn{sub 1/3}Ir{sub 2/3}O{sub 2}: neutron diffraction patterns in the main panel and synchrotron diffraction in the insets. The patterns show a small amount of ordering in the transition metal iridium layer. Display Omitted - Highlights: • We report six ternary sodium iridates with the α-NaFeO{sub 2} structure. • Compounds Na{sub 1−x}M{sub 1/3}Ir{sub 2/3}O{sub 2}, M=Co, Ni, Cu, Zn and Na{sub 1−x}M{sub 2/3}Ir{sub 1/3}O{sub 2}, M=Mn, Fe. • Rietveld refinement of powder neutron diffraction data. • All compounds are spin glasses. • NMR comparison to Na{sub 2}IrO{sub 3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗