Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sub-second”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

50 records · Page 3

Maintaining Balance: The Increasing Role of Energy Storage for Renewable Integration

For nearly a century, global power systems have focused on three key functions: generating, transmitting, and distributing electricity as a real-time commodity. Physics requires that electricity generation always be in real-time balance with load-despite variability in load on time scales ranging from subsecond disturbances to multiyear trends. With the increasing role of variable generation from wind and solar, the retirement of fossil-fuel-based generation, and a changing consumer demand profile, grid operators are using new methods to maintain this balance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Simulation of PV Variability as a Function of PV Generation and Plant Size

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear-and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute time-scale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

irradiance↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a High Resolution, Real Time, Distribution-Level Metering System and Associated Visualization, Modeling, and Data Analysis Functions

NREL is developing measurement devices and a supporting data collection network specifically targeted at electrical distribution systems to support research in this area. This paper describes the measurement network which is designed to apply real-time and high speed (sub-second) measurement principles to distribution systems that are already common for the transmission level in the form of phasor measurement units and related technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonsteady Load Responses of Wind Turbines to Atmospheric and Mountain-Generated Turbulence Eddies, With Impacts on the Main Bearing: A Validation Study

Previous computational and field experiments identify three characteristic time scales in the aerodynamic responses of utility-scale wind turbine loads to atmospheric boundary layer (ABL) turbulence: a 30-90 second time scale for the passage of high/low speed "streaks" through the rotor plane, the blade and rotor rotation time scales (approximately 1 to 5 seconds), and a sub-second time scale created by blade rotation through gradients within eddy coherent structure. In the current study we compare aerodynamic load responses from daytime ABL turbulence quantified with large-eddy simulation and a actuator line model of the NREL 5 MW wind turbine with analysis of field data from the NREL/GE 1.5 MW wind turbine 5 kilometers east of the Rocky Mountain Front Range in Colorado. In addition, we contrast the responses to the passage of the mountain-generated eddies embedded within the westerly winds with the ABL eddies embedded within northerly/southerly winds. These analyses are in context with the nonsteady forcing of the main bearing by the aerodynamic generation of nontorque bending moments on the main shaft. Potentially relevant to main bearing failure mechanisms, both computational and field data show that the magnitudes of turbulence-generated nontorque bending moments, that we show generate nonsteady force on the main bearing, are of order, and often larger than, torque (which underlies power). However, the temporal variations in these two responses are uncorrelated, implying that the aerodynamic mechanisms that drive power and main bearing response are fundamentally different. We find this to be the case in the field with both mountain-generated eddies (westerly winds) and ABL-generated eddies (northerly/southerly winds). Whereas the time and length scales are comparable, the mountain eddies were somewhat more energetic than the northerly/southerly ABL eddies. Interestingly, however, the fluctuations in nontorque bending moment that force the main bearing were found to be stronger when forced by the ABL eddies than the mountain eddies. The field studies validate the key results from the computational study and show even stronger response in the nontorque bending moment than in the computer simulations. In all cases, the torque and nontorque bending moments are temporally uncorrelated, torque and power are driven by time variations in rotor-averaged horizontal wind velocity and nontorque bending moments are driven by time changes in the degree of nonuniformity in the distribution of velocity over the rotor plane. Thus the results generalize the mechanisms underlying nonsteady aerodynamic forcing to classes of turbulence eddy types with strength of order or stronger than ABL eddies with transverse scale of order the wind turbine rotor. These include atmospheric turbulence eddies, topography-generated turbulence eddies and, by extension, impacts of turbine-wake-scale turbulence eddies on downstream wind turbine rotors.

17 WIND ENERGY↗

Multi-physics Preconditioning for Thermally Activated Batteries

Thermal batteries, also known as molten-salt batteries, are single-use reserve power systems activated by pyrotechnic heat generation, which transitions the solid electrolyte into a molten state. The simulation of these batteries relies on multiphysics modeling to evaluate performance and behavior under various conditions. This paper presents advancements in scalable preconditioning strategies for the Thermally Activated Battery Simulator (TABS) tool, enabling efficient solutions to the coupled electrochemical systems that dominate computational costs in thermal battery simulations. We propose a hierarchical block Gauss-Seidel preconditioner implemented through the Teko package in Trilinos, which effectively addresses the challenges posed by tightly coupled physics, including charge transport, porous flow, and species diffusion. The preconditioner leverages scalable subblock solvers, including smoothed aggregation algebraic multigrid (SA-AMG) methods and domain-decomposition techniques, to achieve robust convergence and parallel scalability. Strong and weak scaling studies demonstrate the solver’s ability to handle problem sizes up to 51.3 million degrees of freedom on 2048 processors, achieving near sub-second setup and solve times for the end-to-end electrochemical solve. These advancements significantly improve the computational efficiency and turnaround time of thermal battery simulations, paving the way for higher-resolution models and enabling the transition from 2D axisymmetric to full 3D simulations.

25 ENERGY STORAGE↗

Testing and Validation of Wireless Communication Architecture for Heliostat Fields: SIPS Final Report

This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.

14 SOLAR ENERGY↗

High-Performance Computing for Real-Time Grid Analysis and Operation

Power grids worldwide are undergoing an unprecedented transition as a result of grid evolution meeting information revolution. The grid evolution is largely driven by the desire for green energy. Emerging grid technologies such as renewable generation, smart loads, plug-in hybrid vehicles, and distributed generation provide opportunities to generate energy from green sources and to manage energy use for better system efficiency. With utility companies actively deploying these technologies, a high level of penetration of these new technologies is expected in the next 5-10 years, bringing in a level of intermittency, uncertainties, and complexity that the grid did not see nor design for. On the other hand, the information infrastructure in the power grid is being revolutionized with large-scale deployment of sensors and meters in both the transmission and distribution networks. The future grid will have two-way flows of both electrons and information. The challenge is how to take advantage of the information revolution: pull the large amount of data in, process it in real time, and put information out to manage grid evolution. Without addressing this challenge, the opportunities in grid evolution will remain unfulfilled. This transition poses grand challenges in grid modeling, simulation, and information presentation. The computational complexity of underlying power grid modeling and simulation will significantly increase in the next decade due to an increased model size and a decreased time window allowed to compute model solutions. High-performance computing is essential to enable this transition. The essential technical barrier is to vastly increase the computational speed so operation response time can be reduced from minutes to seconds and sub-seconds. The speed at which key functions such as state estimation and contingency analysis are conducted (typically every 3-5 minutes) needs to be dramatically increased so that the analysis of contingencies is both comprehensive and real time. An even bigger challenge is how to incorporate dynamic information into real-time grid operation. Today’s online grid operation is based on a static grid model and can only provide a static snapshot of current system operation status, while dynamic analysis is conducted offline because of low computational efficiency. The offline analysis uses a worst-case scenario to determine transmission limits, resulting in under-utilization of grid assets. This conservative approach does not necessarily lead to reliability. Many times, actual power grid scenarios are not studied, and they will push the grid over the edge and resulting in outages and blackouts. This chapter addresses the HPC needs in power grid analysis and operations. Example applications such as state estimation and contingency analysis are given to demonstrate the value of HPC in power grid applications. Future research directions are suggested for high performance computing applications in power grids to improve the transparency, efficiency, and reliability of power grids.

Contingency Analysis↗

Fast Grid Frequency Support from Distributed Inverter-Based Resources

This presentation summarizes power hardware-in-the-loop testing performed to evaluate the ability of distributed inverter-coupled generation to support grid frequency on the fastest time scales. The research found that distributed PV inverters and other DERs can effectively support the grid on sub-second time scales.

14 SOLAR ENERGY↗

Simulation of PV Variability as a Function of PV Generation and Plant Size: Preprint

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear- and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute timescale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

Langner, Rois↗

Surrogates for Valve-Controlled Pipe Flow: Accelerating Nuclear Reactor Design

Neural surrogate models are developed to replace expensive steady-state RANS CFD simulations for valve-controlled pipe flow in nuclear reactor design. Using parametric CFD data generated with MOOSE Pronghorn across a range of valve geometry and flow conditions, three approaches are compared: a POD-based reduced-order model, a structured UNet on a cylindrical grid, and unstructured models (DeepONet and BiStride MeshGraphNet) on nondimensionalized point clouds. POD achieves the highest accuracy (99%) with fast inference but requires storing all solution snapshots, while the DeepONet and BSMS-GNN both achieve ~89% accuracy at sub-second inference, with the BSMS-GNN offering superior geometric generalizability. These surrogates enable rapid ranking of candidate valve designs and can warm-start CFD solvers to accelerate convergence, supporting agentic design iteration on the Prometheus platform.

42 - ENGINEERING↗