Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Parameter extraction for a SPICE model of an hTron superconducting thermal switch

Efficiently simulating large circuits is crucial to the development of superconducting nanowire-based electronics. However, current simulation tools for this technology are not adapted to the scaling of circuit size and complexity. We focus on the multilayered heater-nanocryotron (hTron), a promising superconducting nanowire-based switch used in applications such as superconducting nanowire single-photon detector readout. Previously, the hTron was modeled using traditional finite-element methods, which fall short in simulating systems at a larger scale. An empirical-based method would be better adapted to this task, enhancing both simulation speed and agreement with experimental data. In this work, we perform switching current and activation delay measurements on 17 hTron devices. We then develop a method for extracting physical fitting parameters used to characterize the devices. We build a SPICE behavioral model that reproduces the static and transient device behavior using these parameters, and validate it by comparing its performance to a model developed in prior work, showing an improvement in simulation time by several orders of magnitude. Furthermore, our model provides circuit designers with a tool to help understand the hTron’s behavior during all design stages, thus enabling broader use of the hTron across various new areas of application.

Caloritronics↗

Nanoscale functionalized superconducting transport channels as photon detectors

Herein, single-photon detectors have typically consisted of macroscopic materials where both the photon absorption and transduction to an electrical signal happen. Newly proposed designs suggest that large arrays of nanoscale detectors could provide improved performance in addition to decoupling the absorption and transduction processes. Here we study the properties of such a detector consisting of a nanoscale superconducting (SC) transport channel functionalized by a photon absorber. We explore two detection mechanisms based on photoinduced electrostatic gating and magnetic effects. To this end we model the narrow channel as a one-dimensional atomic chain and use a self-consistent Keldysh-Nambu Green's function formalism to describe nonequilibrium effects and SC phenomena. We consider cases where the photon creates electrostatic and magnetic changes in the absorber, as well as devices with strong and weak coupling to the metal leads. Our results indicate that the most promising case is when the SC channel is weakly coupled to the leads and in the presence of a background magnetic field, where photoexcitation of a magnetic molecule can trigger a SC-to-normal transition in the channel that leads to a change in the device current several times larger than in the case of a normal-phase channel device.

1-dimensional systems↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors are superconducting microcalorimeters that use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the device substrate. In order to improve the design of these detectors, we need to understand the effect of various detector design elements on the physical processes that take place within the detector through simulation efforts. One figure of merit for KIPM detectors is the phonon collection efficiency, $\eta_{ph]$, defined as the ratio of phonon energy detected by the sensitive element in the detector and the energy deposited by incident phonons in the substrate. Comparing the phonon collection efficiency obtained in simulation and in experiment for the same detector geometry provides insight to physical processes in the detector, such as phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements. This work models the phonon collection efficiency in two KIPM detectors with different geometries, one located at the Fermi National Accelerator Laboraory, the other located at the SLAC National Accelerator Laboratory.

Dang, Stella Q.↗

A Search for Sterile Neutrino Dark Matter (Final Report)

Decades of dark matter searches with increasingly higher sensitivity have so far not been able to detect the most-favored hypothetical dark matter particles. This has increased interest in sterile neutrinos with masses in the kilo-electronvolt (keV) range as possible dark matter candidates. We have established a and new and world-leading approach to search for keV-scale sterile neutrinos with superconducting radiation detectors. For this, we have implanted radioactive beryllium-7 (Be-7) nuclei into our superconducting tunnel junction (STJ) detectors and measured the recoil energy of the lithium-7 (Li-7) daughter nucleus with high accuracy. If the associated electron neutrino wave function contains some admixture of a keV sterile flavor, the Li-7 recoil energy will be shifted and produce an additional peak in the spectrum whose energy depends on the sterile neutrino mass. While we have not observed any evidence for sterile neutrinos in these precision decay experiments, the experiment has increased the sensitivity of sterile neutrino searches by a factor of ~10 over competing approaches in the mass range from ~10 to ~800 keV. The next generation of STJ detectors that we have developed as part of this project will be able further increase the sensitivity of the sterile neutrino search by at least another two orders of magnitude.

42 ENGINEERING↗

Fermilab's controls development with virtual accelerator

Control Systems development is often the last thing considered when designing and building new equipment, e.g. a new detector or superconducting RF LINAC; however when the new equipment is installed, it is the first thing desired to be operational for testing. Due to frequent delays in building new equipment and project deadlines, control system development and testing is often curtailed. A way to alleviate this problem is to simulate the control system, though this will be challenging for complex systems.The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC for the remainder of the existing accelerator complex. The new LINAC consists of a warm front end (WFE), 23 superconducting RF cryomodules (of 5 types), and a beam transfer line (BTL) to the existing complex.The accelerator physics group has a parallel project to create a digital twin (DT) of the PIP-II accelerator. We have coupled the EPICS controls to this DT and are developing both the DT and EPICS software in parallel. This will allow us to develop the EPICS software framework, the HMIs, sequences, high level physics applications, and other services for use in a fully functional control system.This presentation will detail the work that we have performed to date and show demonstrations of controlling and monitoring the status of the accelerator, as well as future plans for this work.

Hanlet, Pierrick [Fermilab]↗

First operation of superconducting quantum bits as particle detectors

Transmon qubits are among the leading technologies for the development of future quantum computers. However these superconducting devices are sensitive to ionizing radiation, which reduces their coherence time and leads to correlated errors. This study represents the first quantitative estimation of cosmic rays and ambient radiation impact on transmon qubits. In the shielded underground facility at the Laboratori Nazionali del Gran Sasso (LNGS), errors induced by the interaction of a radioactive source were reconstructed with an efficiency of about 10%. In contrast, in the unshielded above-ground facility at the Fermi National Accelerator Laboratory (FNAL), cosmic and ambient radiation impacts were detected with an efficiency ranging from 10% to 20% by modifying the acquisition protocol. Lastly, the simultaneous readout of three transmons in coincidence was demonstrated, achieving an event reconstruction efficiency of 90% when the devices were illuminated with an LED.

Bonomo, Camilla [Rome U.; INFN, Rome]↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

Dark matter searches and energy accumulation and release in materials

Efforts to identify dark matter by detecting nuclear recoils produced by dark matter particles reveal low-energy backgrounds of unknown origin in different types of detectors. In many cases, energy accumulation and delayed burst-like releases of stored energy could provide an explanation. These dynamics follow Prigogine’s ideas on systems with energy flow and the general Self-Organized Criticality scenario. We compare these models with properties of excess backgrounds in cryogenic solid-state detectors, relaxation processes in glasses and crystals, our observations of delayed luminescence in NaI(Tl), and make predictions for more phenomena present in these systems and in superconducting photon detectors and qubits. Experiments to create accurate phenomenological models are needed.

Pereverzev, Sergey↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗