Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface contamination on LDEF exposed materials

X-ray photoelectron spectroscopy (XPS) has been used to study the surface composition and chemistry of Long Duration Exposure Facility (LDEF) exposed materials including silvered Teflon (Ag/FEP), Kapton, S13GLO paint, quartz crystal monitors (QCM's), carbon fiber/organic matrix composites, and carbon fiber/Al Alloy composites. In each set of samples, silicones were the major contributors to the molecular film accumulated on the LDEF exposed surfaces. All surfaces analyzed have been contaminated with Si, O, and C; most have low levels (less than 1 atom percent) of N, S, and F. Occasionally observed contaminants included Cl, Na, K, P, and various metals. Orange/brown discoloration observed near vent slots in some Ag/FEP blankets were higher in carbon, sulfur, and nitrogen relative to other contamination types. The source of contamination has not been identified, but amine/amide functionalities were detected. It is probable that this same source of contamination account for the low levels of sulfur and nitrogen observed on most LDEF exposed surfaces. XPS, which probes 50 to 100 A in depth, detected the major sample components underneath the contaminant film in every analysis. This probably indicates that the contaminant overlayer is patchy, with significant areas covered by less that 100 A of molecular film. Energy dispersive x-ray spectroscopy (EDS) of LDEF exposed surfaces during secondary electron microscopy (SEM) of the samples confirmed contamination of the surfaces with Si and O. In general, particulates were not observed to develop from the contaminant overlayer on the exposed LDEF material surfaces. However, many SiO2 submicron particles were seen on a masked edge of an Ag/FEP blanket. In some cases such as the carbon fiber/organic matrix composites, interpretation of the contamination data was hindered by the lack of good laboratory controls. Examination of laboratory controls for the carbon fiber/Al alloy composites showed that preflight contamination was the most significant factor for all the contaminants generally detected at less than 1 atom percent, or detected only occasionally (i.e., all but Si, O, and C). Flight control surfaces, including sample backsides not exposed to space radiation or atomic oxygen flux, have accumulated some contamination on flight (compared to laboratory controls), but experimentally, the LDEF exposed surface contamination levels are generally higher for the contaminants Si and O. For most materials analyzed, Si contamination levels were higher on the leading edge surfaces than on the trailing edge surfaces. This was true even for the composite samples where considerable atomic oxygen erosion of the leading edge surfaces was observed by SEM. It is probable that the return flux associated with atmospheric backscatter resulted in enhanced deposition of silicones and other contaminants on the leading edge flight surfaces relative to the trailing edge. Although the Si concentration data suggested greater on-flight deposition of contaminants on the leading edge surfaces, the XPS analyses did not conclusively show different relative total thicknesses of flight deposited contamination for leading and trailing edge surfaces. It is possible that atomic oxygen reactions on the leading edge resulted in greater volatilization of the carbon component of the deposited silicones, effectively 'thinning' the leading edge deposited overlayer. Unlike other materials, exposed polymers such as Kapton and FEP-type Teflon had very low contamination on the leading edge surfaces. SEM evidence showed that undercutting of the contaminant overlayer and damaged polymer layers occurred during atomic oxygen erosion, which would enhance loss of material from the exposed surface.

Hemminger, Carol S.↗

Data documentation for the bare soil experiment at the University of Arkansas, June - August 1980

The primary objective of this study is to evaluate the relationships between soil moisture and reflectivity of a bare soil, using microwave techniques. A drainage experiment was conducted on a Captina silt loam in cooperation with personnel in the Electrical Engineering Department. Measurements included soil moisture pressures at various depths, neutron probe measurements, gravimetric moisture samples, and reflectivity of the soil surface at selected frequencies including 1.5 and 6.0 GHz and at the incident angle of 45 deg. All measurements were made in conjuction with that of reflectivity data.

Sadeghi, A. M.↗

Design of a scientific probe for obtaining Mars surface material

The objective is to return a 1 Kg Martian soil sample from the surface of Mars to a mothership in a 60 km Mars orbit. Given here is information on the mission profile, the structural design and component placement, thermal control and guidance, propulsion systems, orbital mechanics, and specialized structures.

Baker, Miles↗

Next-Generation Tumbleweed Rover

A document describes a next-generation tumbleweed rover that involves a split balloon system that is made up of two half-spherical air bladders with a disc between them. This disc contains all the electronics and instruments. By deflating only the bottom balloon, the rover can sit, bringing the surface probe into contact with the ground. The bottom balloon has a channel passing through it, allowing the surface probe to reach the surface through the balloon. Once the sample has been gathered and analyzed, the rover can re-inflate the lower air bladder and continue rolling. The rover will use a small set of instruments and electronics situated at the center of its inflatable spherical hull. The current version is a large beach-ball-like construction, about 1.8 m in diameter and weighing roughly 15 kg. The rover comprises two major parts, an outer spherical hull (split in half at the central disc) and an inner, disc-shaped cylindrical section. The balloons are attached to the bottom and top of the disc. Inside the disc, there are temperature and pressure sensors to keep track of the inner and outer conditions of the rover. A system of pumps and valves is responsible for independently inflating and deflating the balloons as necessary. There are also accelerometers to record the movement, together with a GPS receiver. The data are then sent through a modem to a control station. This work builds upon the project Tumbleweed rover for planetary exploration, described in the Technical Support Package.

Nosanov, Jeffrey P.↗

Development, fabrication and testing of a magnetically connected plastic vacuum probe surface sampler

The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.

Phillips, G. B.↗

Planetary mission summaries. Volume 1: Introduction and overview

Tabular synopses of twelve missions are presented along with the Mariner Jupiter/Saturn 1977 mission for comparison. Mission definitions considered include: Mars Polar Orbiter; Mars Surface Sample Return; Mars Rover; Marine Jupiter/Uranus 1979 with Uranus Entry Probe; Mariner Jupiter Orbiter; Mariner Mercury Orbiter 1978; Early Mariner Comet Flyby Solar Electric Encke Slow Flyby; Mariner Encke Ballistic Flyby; Solar Electric Encke Rendezvous 1981; Venus Orbital Imaging Radar; Solar Electric Out-of-the-Eliptic Probe 1979. Technical conclusions of mission studies are given in order that these results may interact with the broader questions of scope, pace, and priorities in the planetary exploration program.

Source record↗

Characterizing Surfaces of the Wide Bandgap Semiconductor Ilmenite with Scanning Probe Microcopies

Ilmenite (FeTiO3) is a wide bandgap semiconductor with an energy gap of about 2.5eV. Initial radiation studies indicate that ilmenite has properties suited for radiation tolerant applications, as well as a variety of other electronic applications. Two scanning probe microscopy methods have been used to characterize the surface of samples taken from Czochralski grown single crystals. The two methods, atomic force microscopy (AFM) and scanning tunneling microscopy (STM), are based on different physical principles and therefore provide different information about the samples. AFM provides a direct, three-dimensional image of the surface of the samples, while STM give a convolution of topographic and electronic properties of the surface. We will discuss the differences between the methods and present preliminary data of each method for ilmenite samples.

Wilkins, R.↗

Simulation of radar reflectivity and surface measurements of rainfall

Raindrop size distributions (RSDs) are often estimated using surface raindrop sampling devices (e.g., disdrometers) or optical array (2D-PMS) probes. A number of authors have used these measured distributions to compute certain higher-order RSD moments that correspond to radar reflectivity, attenuation, optical extinction, etc. Scatter plots of these RSD moments versus disdrometer-measured rainrates are then used to deduce physical relationships between radar reflectivity, attenuation, etc., which are measured by independent instruments (e.g., radar), and rainrate. In this paper RSDs of the gamma form as well as radar reflectivity (via time series simulation) are simulated to study the correlation structure of radar estimates versus rainrate as opposed to RSD moment estimates versus rainrate. The parameters N0, D0 and m of a gamma distribution are varied over the range normally found in rainfall, as well as varying the device sampling volume. The simulations are used to explain some possible features related to discrepancies which can arise when radar rainfall measurements are compared with surface or aircraft-based sampling devices.

Chandrasekar, V.↗

Instrument for Measuring Cryo CTE

Coefficient of thermal expansion is an integral part of the performance of optical systems, especially for those, which operate at cryogenic temperatures. The measurement of the coefficient of relevant materials has been of continuous interest. Besides commercial measurement sources, development of one-of-a-kind tools have always been of interest due to local needs. This paper describes one such development at the University of Alabama in Huntsville (UAH). The approach involves two vertical rods (one sample and one reference) on a flat platform. A probe bar is held horizontally atop the two samples. A temperature change will generally cause rotation of the probe bar. A mirrored surface on one end of the probe bar is used to measure the rotation using the reflection of an incident laser beam upon it. A position-sensing detector measures the change of the reflected beam spot position. Using other known quantities, the change determines the coefficient of thermal expansion of the sample material as a function of temperature. A parallel measurement of the rotation of the sample support platform is also performed to account for any unwanted background effects. This system has been demonstrated in a cryogenic chamber at the NASA Marshall Space Flight Center X-ray Calibration Facility (XRCF). We present the system details, achievable sensitivity, and up-to-date experimental performance.

Vikram, Chandra S.↗

Enumeration and Fluorescence In Situ Hybridization of Microbial Bioburden on Cleanroom Surfaces

Introduction: Microorganisms are everywhere on Earth, even in the cleanest of places. Spacecraft assembly cleanrooms can harbor low levels of living and dead microbial cells (e.g., [1,2]), and cleanroom bioburden can also include organic molecules from industrial sources and in situ biomass. Life detection missions require careful attention to avoid contaminants that can be easily convoluted with analytical targets. We are evaluating epifluorescent microscopy and fluorescence in situ hybridization (FISH) as methods to complement organic contamination detection techniques. Epifluorescent cell counting offers an accurate and cost-effective way to quantify low levels of surface biomass. FISH could allow for the identification of residual organisms, and can be targeted to detect active populations of specific organisms such as bacteria known to resist cleaning procedures. This effort is part of a larger study that is concentrated on characterizing the surface and airborne molecular organic contamination background in Johnson Space Center (JSC) Astromaterials curation laboratories and Goddard Space Flight Center (GSFC) spacecraft assembly rooms, and understanding contaminants in the context of cleaning procedures and residual bioburden. Methods: Samples were collected by swabbing surfaces in ISO 5 and ISO 7 equivalent cleanrooms at JSC. Swabs for FISH were fixed in 4% paraformaldehyde (PFA) for 3 hours and then stored in 1:1 ethanol:PBS, while swabs for cell counting were stored in 4% PFA until analysis to avoid any cell loss during centrifugation that could impact quantification of very low biomass samples. Cell counting was performed with SYBR Gold as in [3], but adapted for very low biomass. FISH was performed as in [4], using DAPI as a counterstain for all DNA-containing cells. Negative controls included wells with no probe applied, to test for natural fluorescence, as well as the nonsense probe NONEUB (reverse complement of EUB338) to evaluate non-specific probe binding. Results and Discussion: Cleanroom surfaces had 102-103 cells cm-2. The extremely low biomass of these samples was challenging for enumeration, and required careful and routine use of “field” and laboratory blanks. FISH was performed with the general archaeal and bacterial probes ARCH915 and EUB338 (EUBMIX, [4]), probe GAMBET ([4]), and PSE227, which targets the genus Pseudomonas [5]). The latter two probes were selected because Pseudomonas spp. and other Gammaproteobacteria have not been isolated from cleanroom surfaces but do appear frequently in rRNA gene libraries from these surfaces. While some active bacteria were identified (Fig. 1c), most cells detectable by DAPI did not have a strong or any fluorescent signal (e.g., Fig. 1d), indicating that the vast majority of cells are dead or inactive. This suggests that cleaning protocols are effective at inactivating microbial contaminants, but that dead or inactive cells can remain on surfaces. Cells were often clumped in a weakly autofluorescent matrix, possibly biofilm material (Fig. 1c,d). We also observed other particulate material that was collected by the swabs, including apparent textile fibers (Fig. 1b). Our results are consistent with other studies that show that the bioburden present in clean rooms includes active, dormant, and dead cells. We will discuss how FISH and epifluorescent cell counting could be applied in planetary protection protocols, including the advantages and disadvantages of FISH and cell counting for routine use, as well as different possible applications for more specialized FISH procedures. References: [1] Moissl-Eichinger et al. (2015) Sci Rep, 5, 9156 [2] Hendrickson et al. (2021) Microbiome, 9, 238 [3] Jones et al. (2017) Appl Environ Microbiol, 83, e00909-17 [4] Jones et al. (2015) Appl Environ Microbiol, 81, 1242-1250. [5] Watt et al. (2006) Environ Microbiol, 8, 871-884

C J Huff↗

Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

Pachlhofer, Peter↗

Camera, Hand Lens, and Microscope Probe (CHAMP): An Instrument Proposed for the 2009 MSL Rover Mission

The Camera, Hand Lens, and Microscope Probe (CHAMP) will allow examination of martian surface features and materials (terrain, rocks, soils, samples) on spatial scales ranging from kilometers to micrometers, thus enabling both microscopy and context imaging with high operational flexibility. CHAMP is designed to allow the detailed and quantitative investigation of a wide range of geologic features and processes on Mars, leading to a better quantitative understanding of the evolution of the martian surface environment through time. In particular, CHAMP will provide key data that will help understand the local region explored by Mars Surface Laboratory (MSL) as a potential habitat for life. CHAMP will also support other anticipated MSL investigations, in particular by helping identify and select the highest priority targets for sample collection and analysis by the MSL's analytical suite.

hand lenses↗

Comparison of three methods for measuring acoustic properties of bulk materials

Three methods for measuring the acoustic properties of bulk materials have been evaluated. The methods differ from one another in their practical implementation and reliability. The two more convenient methods exploit changes in surface impedance of test samples resulting from a change in the test sample geometry or boundary conditions. The results from these surface methods are compared with that obtained using Scott's method. In Scott's method the propagation constant is obtained by a 'direct' measurement inside the test material by means of a probe tube. The comparisons suggest that the surface methods will provide reliable and accurate results when the test sample behaves as a rigid porous structure.

Smith, C. D.↗

MSATT Workshop on Innovative Instrumentation for the In Situ Study of Atmosphere-Surface Interactions on Mars

Papers accepted for the Mars Surface and Atmosphere Through Time (MSATT) Workshop on Innovative Instruments for the In Situ Study of Atmosphere-Surface Interaction of Mars, 8-9 Oct. 1992 in Mainz, Germany are included. Topics covered include: a backscatter Moessbauer spectrometer (BaMS) for use on Mars; database of proposed payloads and instruments for SEI missions; determination of martian soil mineralogy and water content using the Thermal Analyzer for Planetary Soils (TAPS); in situ identification of the martian surface material and its interaction with the martian atmosphere using DTA/GC; mass spectrometer-pyrolysis experiment for atmospheric and soil sample analysis on the surface of Mars; and optical luminescence spectroscopy as a probe of the surface mineralogy of Mars.

Fegley, Bruce, Jr.↗

Two-Photon Laser-Induced Fluorescence O and N Atoms for the Study of Heterogeneous Catalysis in a Diffusion Reactor

Advanced laser-based diagnostics have been developed to examine catalytic effects and atom/surface interactions on thermal protection materials. This study establishes the feasibility of using laser-induced fluorescence for detection of O and N atom loss in a diffusion tube to measure surface catalytic activity. The experimental apparatus is versatile in that it allows fluorescence detection to be used for measuring species selective recombination coefficients as well as diffusion tube and microwave discharge diagnostics. Many of the potential sources of error in measuring atom recombination coefficients by this method have been identified and taken into account. These include scattered light, detector saturation, sample surface cleanliness, reactor design, gas pressure and composition, and selectivity of the laser probe. Recombination coefficients and their associated errors are reported for N and O atoms on a quartz surface at room temperature.

Pallix, Joan B.↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

NASA takes stock

The history of NASA activities and achievements in the past decade is reviewed with consideration given to the Apollo expeditions and the post-Apollo planetary exploration. Progress in spaceborne astronomy and in satellite communications is characterized as revolutionary. It is also noted that Landsat alone may eventually repay the United States for the cost of the entire space program. Special attention is given to the Shuttle program which will be the key to all operations in space for the next decade including the Galileo mission to Jupiter (1982) and the Space Telescope (1983). Future missions could include a Venus orbiter with imaging radar to finally penetrate the cloud cover of the planet and to map its surface; a rover or sample return expedition to Mars; a Saturn orbiter combined with a probe of its Titan satellite, and an examination of Halley's Comet. Finally the next decade should bring the data needed to make a 'go' or 'no go' decision on the concept of SPS that would beam solar energy into earth stations.

Frosch, R. A.↗

The Cassini-Huygens Mission Overview

The Cassini-Huygens Program is an international science mission to the Saturnian system. Three space agencies and seventeen nations contributed to building the Cassini spacecraft and Huygens probe. The Cassini orbiter is managed and operated by NASA's Jet Propulsion Laboratory. The Huygens probe was built and operated by the European Space Agency. The mission design for Cassini-Huygens calls for a four-year orbital survey of Saturn, its rings, magnetosphere, and satellites, and the descent into Titan's atmosphere of the Huygens probe. The Cassini orbiter tour consists of 76 orbits around Saturn with 45 close Titan flybys and 8 targeted icy satellite flybys. The Cassini orbiter spacecraft carries twelve scientific instruments that are performing a wide range of observations on a multitude of designated targets. The Huygens probe carried six additional instruments that provided in-situ sampling of the atmosphere and surface of Titan. The multi-national nature of this mission poses significant challenges in the area of flight operations. This paper will provide an overview of the mission, spacecraft, organization and flight operations environment used for the Cassini-Huygens Mission. It will address the operational complexities of the spacecraft and the science instruments and the approach used by Cassini-Huygens to address these issues.

mission operations↗