Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surveillance Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low-dose computed tomography image restoration using previous normal-dose scan

Purpose: In current computed tomography (CT) examinations, the associated x-ray radiation dose is of a significant concern to patients and operators. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) or kVp parameter (or delivering less x-ray energy to the body) as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and the noise would propagate into the CT image if no adequate noise control is applied during image reconstruction. Since a normal-dose high diagnostic CT image scanned previously may be available in some clinical applications, such as CT perfusion imaging and CT angiography (CTA), this paper presents an innovative way to utilize the normal-dose scan as a priori information to induce signal restoration of the current low-dose CT image series. Methods: Unlike conventional local operations on neighboring image voxels, nonlocal means (NLM) algorithm utilizes the redundancy of information across the whole image. This paper adapts the NLM to utilize the redundancy of information in the previous normal-dose scan and further exploits ways to optimize the nonlocal weights for low-dose image restoration in the NLM framework. The resulting algorithm is called the previous normal-dose scan induced nonlocal means (ndiNLM). Because of the optimized nature of nonlocal weights calculation, the ndiNLM algorithm does not depend heavily on image registration between the current low-dose and the previous normal-dose CT scans. Furthermore, the smoothing parameter involved in the ndiNLM algorithm can be adaptively estimated based on the image noise relationship between the current low-dose and the previous normal-dose scanning protocols. Results: Qualitative and quantitative evaluations were carried out on a physical phantom as well as clinical abdominal and brain perfusion CT scans in terms of accuracy and resolution properties. The gain by the use of the previous normal-dose scan via the presented ndiNLM algorithm is noticeable as compared to a similar approach without using the previous normal-dose scan. Conclusions: For low-dose CT image restoration, the presented ndiNLM method is robust in preserving the spatial resolution and identifying the low-contrast structure. The authors can draw the conclusion that the presented ndiNLM algorithm may be useful for some clinical applications such as in perfusion imaging, radiotherapy, tumor surveillance, etc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertical air motion retrievals in deep convective clouds using the ARM scanning radar network in Oklahoma during MC3E

The US Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program's Southern Great Plains (SGP) site includes a heterogeneous distributed scanning Doppler radar network suitable for collecting coordinated Doppler velocity measurements in deep convective clouds. The surrounding National Weather Service (NWS) Next Generation Weather Surveillance Radar 1988 Doppler (NEXRAD WSR-88D) further supplements this network. Radar velocity measurements are assimilated in a three-dimensional variational (3DVAR) algorithm that retrieves horizontal and vertical air motions over a large analysis domain (100 km × 100 km) at storm-scale resolutions (250 m). For the first time, direct evaluation of retrieved vertical air velocities with those from collocated 915 MHz radar wind profilers is performed. Mean absolute and root-mean-square differences between the two sources are of the order of 1 and 2 m s -1 , respectively, and time–height correlations are of the order of 0.5. An empirical sensitivity analysis is done to determine a range of 3DVAR constraint weights that adequately satisfy the velocity observations and anelastic mass continuity. It is shown that the vertical velocity spread over this range is of the order of 1 m s -1 . The 3DVAR retrievals are also compared to those obtained from an iterative upwards integration technique. Lastly, the results suggest that the 3DVAR technique provides a robust, stable solution for cases in which integration techniques have difficulty satisfying velocity observations and mass continuity simultaneously.

54 ENVIRONMENTAL SCIENCES↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Hail Size Distribution Mapping

A 3-D weather radar visualization software program was developed and implemented as part of an experimental Launch Pad 39 Hail Monitor System. 3DRadPlot, a radar plotting program, is one of several software modules that form building blocks of the hail data processing and analysis system (the complete software processing system under development). The spatial and temporal mapping algorithms were originally developed through research at the University of Central Florida, funded by NASA s Tropical Rainfall Measurement Mission (TRMM), where the goal was to merge National Weather Service (NWS) Next-Generation Weather Radar (NEXRAD) volume reflectivity data with drop size distribution data acquired from a cluster of raindrop disdrometers. In this current work, we adapted these algorithms to process data from a cluster of hail disdrometers positioned around Launch Pads 39A or 39B, along with the corresponding NWS radar data. Radar data from all NWS NEXRAD sites is archived at the National Climatic Data Center (NCDC). That data can be readily accessed at . 3DRadPlot plots Level III reflectivity data at four scan elevations (this software is available at Open Channel Software, ). By using spatial and temporal interpolation/extrapolation based on hydrometeor fall dynamics, we can merge the hail disdrometer array data coupled with local Weather Surveillance Radar-1988, Doppler (WSR-88D) radial velocity and reflectivity data into a 4-D (3-D space and time) picture of hail size distributions. Hail flux maps can then be generated and used for damage prediction and assessment over specific surfaces corresponding to structures within the disdrometer array volume. Immediately following a hail storm, specific damage areas and degree of damage can be identified for inspection crews.

Source record↗

A Specialized Ultrasound Protocol for NASA's Renal Stone Surveillance and Clinical Practice

INTRODUCTION Ample evidence exists on the effectiveness of ultrasound in the diagnosis of kidney stones. However, terrestrial practice is mostly concerned with diagnosis of clinically significant urolithiasis. Adapting this non-irradiating, low-cost imaging modality for the asymptomatic astronaut population offers high-sensitivity screening and limits their career radiation dose. METHODS NASA developed a novel ultrasound-based detection and surveillance protocol to identify, categorize, and monitor mineralized renal material (MRM) in astronauts. The term MRM was developed to denote abnormal, presumably calcified, focal material of unknown clinical significance in the kidneys. Sonographic criteria for MRMs include measurable echogenic foci, their detectability in multiple, designated imaging plains, posterior shadowing, and “twinkle” pattern visualized in Color Doppler and/or demonstrated in Spectral Doppler modes. The mere discovery of an MRM does not trigger further imaging or intervention, unless the affected crewmember is mission-assigned, or the MRM meets actionable criteria based on size, location, and sonographic characteristics. If the threshold is met, the crew surgeon is notified, and additional diagnostic imaging and urology consultation are considered. RESULTS In total, 73 individuals have been scanned using our specialized methods, 60 have had more than one study done. As of April 2023, 282 total studies have been performed. So far, over 30 pairs of pre-and postflight studies have been obtained, and the findings are presented elsewhere in this panel. DISCUSSION A surveillance program was initiated nine years ago to screen asymptomatic members of the astronaut corps for renal calcifications, from their initial hiring, through their mission timeframes, and throughout their career. The goal is to reduce the probability that an astronaut will fly with a renal stone that may become symptomatic. This also gives NASA the information it needs to improve screening criteria for future long-duration crewed missions.

H Lyons↗

THE CLOSELY POSITIONED THREE RADIO TRANSIENTS IN THE NASU 1.4 GHz WIDE-FIELD SURVEY

In 2004, we started the Nasu 1.4 GHz wide-field survey to study the dynamic universe by simultaneously performing the surveillance of the wide-field sky. We have detected six radio transients with flux densities larger than 1 Jy. In this paper, we report the detection of three new radio transients in the drift-scanning observations at {delta} {approx} +41.{sup 0}7. Based on their positions in the sky and flux densities, we considered the candidate types of astronomical objects for transients. As a result, it is suggested that the three radio transients could be massive radio flares associated with known extragalactic sources, such as active galactic nuclei, which are usually very faint in X-ray and radio wavelengths. The three transients were found in the sky of 2{sup 0} x 1{sup 0}, while nine transients, including the three transients reported in this paper, are distributed at both high and low Galactic latitude. According to the observational results, we suggest that the wide-field survey simultaneously performed would be useful in searching for radio transients to study the dynamic radio sky.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of lung nodule detectability in low-dose 320-slice computed tomography

Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from {approx}0.1 mGy up to that typical of low-dose CT (LDCT, {approx}5 mGy) and diagnostic CT ({approx}10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of {approx}3 (from {approx}3.3 mGy for sharp filters to {approx}1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of reconstruction parameters. Image noise, not spatial resolution, was found to be the limiting factor in detection of small lung nodules. Therefore, the use of smoother reconstruction filters may permit lower-dose protocols without trade-off in diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Quantification of Radiation-Induced Clusters/Precipitates in RPV Steels Using STEM-EDS and Machine Learning

Over the operational lifespan of a nuclear reactor, reactor pressure vessel (RPV) steels are subjected to significant neutron irradiation, resulting in complex microstructural changes and the consequent degradation of mechanical properties. Various physically motivated correlation models have been developed to predict neutron irradiation-induced embrittlement of RPVs under different irradiation conditions. However, the efficient and accurate characterizations and quantification of radiation-induced clusters in RPVs are still challenging, which will affect the precision of the predictive models for embrittlement of RPV components. In the DOE Visiting Faculty Program (VFP) research work at Oak Ridge National Lab (ORNL), I integrate machine learning to aid Scanning Transmission Electron Microscopy – Energy Dispersive X-ray Spectroscopy (STEM-EDS) analyses, which improve the characterization and quantification of radiation-induced clusters in RPV steels, thereby enabling more accurate predictions of material behavior under irradiation. The surveillance base- and welded- RPV steels were annealed at various temperatures of 340 °C, 450 °C and 500 °C for up to 168 hours, respectively. Afterwards, I have characterized radiation-induced clusters using advanced STEM-EDS techniques and subsequently applying machine learning algorithms to analyze and refine STEM-EDS datasets, enhancing the quantification of clusters compositions and distributions. In the end, an efficient workflow for integrating STEM-EDS data analysis with machine learning to address challenges including noise reduction has been developed. The completion of this VFP work will support bridge critical gaps in the accurate quantification of radiation-induced clusters in RPV steels using STEM-EDS and support the development of more precise models for predicting RPV embrittlement in the Light Water Reactor Sustainability program supported by Department of Energy and enhancing the collaboration between ORNL and Alred University. The outcome of the VFP project will leverage a few research papers submission to peer-reviewed journals in the relevant scientific field and a few oral presentations at national and international conferences.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

60 APPLIED LIFE SCIENCES↗

Millimeter-wave imaging sensor data evaluation

A passive 3-mm radiometer system with a mechanically scanned antenna was built for use on a small aircraft or an Unmanned Aerial Vehicle to produce real near-real-time, moderate-resolution (0.5) images of the ground. One of the main advantages of this passive imaging sensor is that it is able to provide surveillance information through dust, smoke, fog and clouds when visual and IR systems are unusable. It can also be used for a variety of remote sensing applications, such as measurements of surface moisture, surface temperature, vegetation extent and snow cover. It is also possible to detect reflective objects under vegetation cover.

Wilson, William J.↗

Mirrors Steer NASA in the Right Direction

Left Hand Design completed the production of the fine-steering mirror technology through 1995 Phase I and 1996 Phase II SBIR contracts with JPL's Interferometric Astronomy group. Presently, the work resulting from the collaboration with NASA represents the company's main line of products for the commercial sector. Aerospace-related applications include: image motion compensation; interceptor seekers for the U.S. Army and Navy; Earth observation and resource monitoring from spacecraft and airborne platforms; space astronomy; helicopter-based surveillance; and interferometric metrology. Left Hand Design's fine-steering mirrors have also penetrated the commercial marketplace with non-aerospace applications, including laser communications, video cameras, infrared inspection, solar observatories, and bathymeters. These cost-effective, commercial mirrors perform a variety of functions, such as scanning, alignment, chopping, tracking, pointing, and beam stabilization. Potential future applications include laser surgery and photolithography.

Source record↗

Analysis techniques for two-dimensional infrared data

In order to evaluate infrared detection and remote sensing systems, it is necessary to know the characteristics of the observational environment. For both scanning and staring sensors, the spatial characteristics of the background may be more of a limitation to the performance of a remote sensor than system noise. This limitation is the so-called spatial clutter limit and may be important for systems design of many earth application and surveillance sensors. The data used in this study is two dimensional radiometric data obtained as part of the continuing NASA remote sensing programs. Typical data sources are the Landsat multi-spectral scanner (1.1 micrometers), the airborne heat capacity mapping radiometer (10.5 - 12.5 micrometers) and various infrared data sets acquired by low altitude aircraft. Techniques used for the statistical analysis of one dimensional infrared data, such as power spectral density (PSD), exceedance statistics, etc. are investigated for two dimensional applicability. Also treated are two dimensional extensions of these techniques (2D PSD, etc.), and special techniques developed for the analysis of 2D data.

Winter, E. M.↗

SETI Investigations at Jodrell Bank, England: September Through November 1983

The radiofrequency interference RFI environment was examined in the frequency band 1404 to 1444 MHz using the DSN Advanced Systems' Radio Frequency Interference Surveillance System. An uncooled FET amplifier was placed on the 12.8-m antenna, and unlimited observing time was made available to the SETI project. One night of observing at 1667 MHz was made available on the 76 m antenna. Preliminary results of four investigations are reported: (1) full scans of the horizon, cataloging RFI events between 1404 and 1444 MHz; (2) lunar reflections of terrestrial RFI signals between 1424 and 1444 MHz; (3) noise background distortions caused by galactic neutral hydrogen emission at 1420.4 MHz; and (4) low sensitivity search for spectral features of F, G, and K stars.

Downs, G. S.↗

Sheep lymph-nodes as a biological indicator of environmental exposure to fluoro-edenite

A significantly increased incidence of pleural mesothelioma in Biancavilla (Sicily, Italy) has been attributed to exposure to fluoro-edenite (FE), a fibrous amphibole extracted from a local stone quarry. The lymph-nodes draining the pulmonary lobes of sheep grazing around the town were examined, to gain insights into fibre diffusion. The pasture areas of six sheep flocks lying about 3 km from Biancavilla were located using the global positioning system. The cranial tracheobronchial and one middle mediastinal lymph-node as well as four lung tissue samples were collected from 10 animals from each flock and from 10 control sheep for light and scanning electron microscopy (SEM) examination. The lymph-nodes from exposed sheep were enlarged and exhibited signs of anthracosis. Histologically, especially at the paracortical level, they showed lymph-follicle hyperplasia with large reactive cores and several macrophages (coniophages) containing grey-brownish particulate interspersed with elements with a fibril structure, forming aggregates of varying dimensions (coniophage nodules). Similar findings were detected in some peribronchiolar areas of the lung parenchyma. SEM examination showed that FE fibres measured 8–41 µm in length and 0.4–1.39 µm in diameter in both lymph-nodes and lung tissue. Monitoring of FE fibres in sheep lymph-nodes using appropriate techniques can help set up environmental pollution surveillance. - Highlights: • Lymph-nodes draining sheep lung were used to assess environmental fluoro-edenite exposure. • Monitoring fluoro-edenite fibres in sheep lung nodes can provide pollution surveillance. • Our findings document a risk of fluoro-edenite fibre inhalation a few kilometres from the source. • Sheep appear to be a valuable bioindicator species.

54 ENVIRONMENTAL SCIENCES↗

FY23 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), and in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or all of: height, color, and grayscale values as functions of position in a plane projection) to detect the presence of surface corrosion and cracking after being trained on similar data with the features to be detected labeled.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of a clinical pathway to assess asymptomatic renal transplant candidates using myocardial perfusion imaging

Abstracts: Background: An AHA/ACCF scientific statement proposed 8 risk factors to assess the need for noninvasive coronary artery disease (CAD) surveillance in asymptomatic patients undergoing evaluation for kidney transplantation. The clinical application of these risk factors and the role of noninvasive testing in this context have not been defined. Methods and Results: We retrospectively followed a cohort of 581 consecutive kidney transplant recipients of whom 401 had pre-transplant radionuclide myocardial perfusion imaging (MPI) and 90 had pre-transplant coronary angiography. The sum of pre-transplant AHA/ACCF risk factors (age >60 years, hypertension, diabetes, cardiovascular disease, dyslipidemia, smoking, dialysis >1 year, left ventricular hypertrophy) was calculated. MPI scans were analyzed by a “blinded” reader. Patients were followed for a mean of 3.7 ± 2.3 years post-transplant for major adverse cardiac events (MACE), defined as cardiac death or non-fatal myocardial infarction. The sum of risk factors was associated with modest discriminatory capacity for obstructive angiographic CAD (area under the curve [AUC], 0.70; P = 0.004), 30-day post-operative MACE (AUC, 0.60; P = 0.036), and long-term MACE (AUC, 0.63; P < 0.001). A threshold of ≥3 risk factors was optimal for identifying patients at risk. MPI provided incremental predictive value for obstructive CAD (P = 0.02) and long-term MACE (P = 0.04) but not post-operative MACE (P = 0.56). MPI was best predictive of long-term MACE in intermediate risk (3-4 risk factors) patients. Conclusions: Asymptomatic kidney transplant candidates with ≥3 AHA/ACCF risk factors are at increased cardiac risk, and should be considered for noninvasive CAD surveillance. Intermediate risk patients (3-4 factors) benefit the most from pre-transplant MPI to define long-term MACE risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗