Search NASASearch

SEARCH · Search NASA

Results for “System Monitoring and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integrated System for Health Management and Autonomous Control (ISHM-AC) for Cryogenic Operations on the Simulated Propellant Loading System

Autonomous control systems represent a technological barrier from manual and automated operated control systems in an industry wide application. An increase in energy-efficient storage, transfer and use of cryogens and cryogenic propellants on Earth and in space has been observed in space related industries between NASA, government and commercial programs. An increase in efficiency of cryogenic systems demands an increase in the capabilities of the control and monitoring system that manages them. As new technologies are developed for cryogenic systems, complexity and capability increases. The increase in complexities are a natural drive to develop better and more capable health monitoring and control system management. Current research and development efforts lead the Cryogenics Test Laboratory at the Kennedy Space Center to improve its automated control and health monitoring system from a Programmable Logic Control (PLC) based-only system to a fully Integrated System for Health Management (ISHM) - Autonomous Control (AC) capable of performing autonomous operations on a cryogenic propellant transfer system. This ISHM-AC system has been developed and tested by controlling a complete simulated propellant transfer operation. The capabilities and test results of this fully integrated autonomous system for cryogenics propellant transfer operation will be presented in this paper.

Toro Medina, Jaime A.

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.

Data sampling system for monitor and control station

System design is based on development of standardized, interchangeable modules that minimize power dissipation, interconnecting cables and size. Maximum flexibility is achieved by using building block approach where all data modules are identical and are connected at any remote location and addressed in random fashion from central unit.

Source record

Potential for integrated optical circuits in advanced aircraft with fiber optic control and monitoring systems

Fiber optic technology is expected to be used in future advanced weapons platforms as well as commercial aerospace applications. Fiber optic waveguides will be used to transmit noise free, high speed data between a multitude of computers as well as audio and video information to the flight crew. Passive optical sensors connected to control computers with optical fiber interconnects will serve both control and monitoring functions. Implementation of fiber optic technology has already begun. Both the military and NASA have several programs in place. A cooperative program, called FOCSI (Fiber Optic Control System Integration), between NASA Lewis and the NAVY to build, environmentally test and flight demonstrate sensor systems for propulsion and flight control systems is currently underway. Integrated Optical Circuits (IOC's) are also being given serious consideration for use in advanced aircraft systems. IOC's will result in miniaturization and localization of components to generate, detect optical signals and process them for use by the control computers. In some complex systems IOC's may be required to perform calculations optically if the technology is ready, replacing some of the electronic systems used today. IOC's are attractive because they will result in rugged components capable of withstanding severe environments in advanced aerospace vehicles. Manufacturing technology developed for microelectronic integrated circuits applied to IOC's will result in cost effective manufacturing. This paper reviews the current FOCSI program and describes the potential role of IOC's in FOCSI applications.

Robert Baumbick

An application of the Multi-Purpose System Simulation /MPSS/ model to the Monitor and Control Display System /MACDS/ at the National Aeronautics and Space Administration /NASA/ Goddard Space Flight Center /GSFC/

The Multi-Purpose System Simulator (MPSS) model was used to investigate the current and projected performance of the Monitor and Control Display System (MACDS) at the Goddard Space Flight Center in processing and displaying launch data adequately. MACDS consists of two interconnected mini-computers with associated terminal input and display output equipment and a disk-stored data base. Three configurations of MACDS were evaluated via MPSS and their performances ascertained. First, the current version of MACDS was found inadequate to handle projected launch data loads because of unacceptable data backlogging. Second, the current MACDS hardware with enhanced software was capable of handling two times the anticipated data loads. Third, an up-graded hardware ensemble combined with the enhanced software was capable of handling four times the anticipated data loads.

Mill, F. W.

Fast-Response Oxygen-Monitoring and Control System

Oxygen sensor is Y2O3-stabilized ZrO2 ceramic disk maintained at 843 degrees C. Overall system response time reduced to about 0.2 second, equal to or less than 1 percent of tunnel run time. When test gas oxygen concentration differs from normal air concentration by 25 percent or more, alarm sounds, and emergency tunnel shutdown signal operates. New ZrO2 sensors intended for hypersonic-vehicle testing.

Singh, J. J.

Data acquisition and processing history for the Explorer 33 (AIMP-D) satellite

The quality control monitoring system, using accounting and quality control data bases, made it possible to perform an in-depth analysis. Results show that the percentage of useable data files for experimenter analysis was 97.7%; only 0.4% of the data sequences supplied to the experimenter exhibited missing data. The 50 percentile probability delay values (referenced to station record data) indicate that the analog tapes arrived within 11 days, the data were digitized within 4.2 weeks, and the experimenter tapes were delivered in 8.95 weeks or less.

Karras, T. J.

X-33 Integrated Test facility, Extended Range Simulation

In support of the X-33 Single Stage To Orbit program, NASA Dryden Flight Research Center was selected to provide continuous communications coverage of the X-33 vehicle from launch, through landing at Malmstrom Air Force Base, Montana and Michaels Army Air Field, Utah. An extensive real-time range simulation capability is being developed to ensure successful communications with the autonomous X-33 vehicle. This paper will provide an overview of the various levels of simulation being developed to support the X-33 extended range subsystems. These subsystems include the Flight Termination System, L-Band command uplink subsystem and the S-Band telemetry downlink subsystem. In addition, the radar model developed provides continuous azimuth, elevation and range information based on the flight trajectory. The Dynamic Ground Station Analysis model developed by NASA Goddard Space Flight Center, calculate the received signal strength at each ground station. This model takes into consideration Radio Frequency (RF) link parameters such as frequency, antenna gain, space loss, plasma effects and the vehicle's position and attitude at any point in time during the flight path. All three RF links are then attenuated based on this calculated level and the RF signals are sent into telemetry receivers to emulate remote sites, or the power incident on the vehicle from uplinked signals. The best source received telemetry data is then passed back to the Launch and Mission Control Monitoring System (LMCMS) resident in the Operations Control Center. The LMCMS also provides the range simulation system the uplink command combined with differential GPS corrections. Later stages will require the progressive integration of actual range hardware with this simulation effort, leading to communication between telemetry, uplink and FTS antennas at NASA Dryden Flight Research Center, with vehicle antennas mounted on the Walter C. Williams Research Aircraft Integration Facility (RAIF). Decommutated Pulse Code Modulated (PCM) data is displayed on one of the four monitors that comprise the Range Safety Officer's (RSO) station. Also displayed are instantaneous impact prediction models, and Federal Aviation Administration (FAA) data for notification of other traffic in the area. Aside from initiating the flight termination command and validating communication links, the RSO station with the range simulation will be used to provide both range control and range safety officers training. The training is necessary to perform their respective functions with greater levels of confidence prior to first flight.

Sharma, Ashley

Real-time reasoning - The monitoring and control of spacecraft systems

Research concerned with automating the monitoring and control of spacecraft systems is discussed. In particular, the application the Procedural Reasoning System (PRS) to the handling of malfunctions in the Reaction Control System (RCS) of NASAs space shuttle is studied. Unlike traditional monitoring and control systems, PRS is able to reason about and perform complex tasks in a very flexible and robust manner, somewhat in the manner of a human assistant. Using various RCS malfunctions as examples (including sensor faults, leaking components, multiple alarms, and regulator and jet failures), it is shown how PRS manages to combine both goal-directed reasoning and the ability to react rapidly to unanticipated changes in its environment. Some important issues in the design of PRS are reviewed, and future enhancements are indicated.

Georgeff, Michael P.

Generating parity relations for detecting and identifying control system component failures

The monitoring of control system sensors and actuators for failures is presently undertaken by means of an exceptionally simple form of generalized parity relations based on a discrete-time model of the dynamics of linear, time-invariant systems. These generalized parity relations are constructed by recourse to a transfer matrix-description of the system that is additionally useful in the interpretation of their properties. Attention is given to a novel method for constructing the parity relation of minimum length that depends on the output of only a single sensor.

Vander Velder, Wallace E.

Orbit transfer rocket engine integrated control and health monitoring system technology readiness assessment

The objectives of this task were to: (1) estimate the technology readiness of an integrated control and health monitoring (ICHM) system for the Aerojet 7500 lbF Orbit Transfer Vehicle engine preliminary design assuming space based operations; and (2) estimate the remaining cost to advance this technology to a NASA defined 'readiness level 6' by 1996 wherein the technology has been demonstrated with a system validation model in a simulated environment. The work was accomplished through the conduct of four subtasks. In subtask 1 the minimally required functions for the control and monitoring system was specified. The elements required to perform these functions were specified in Subtask 2. In Subtask 3, the technology readiness level of each element was assessed. Finally, in Subtask 4, the development cost and schedule requirements were estimated for bringing each element to 'readiness level 6'.

Bickford, R. L.

A study of a space communication system for the control and monitoring of the electric distribution system. Volume 1: Summary

It is technically feasible to design a satellite communication system to serve the United States electric utility industry's needs relative to load management, real-time operations management, remote meter reading, and to determine the costs of various elements of the system. A definition of distribution control and monitoring functions is given. Associated communications traffic is quantified. A baseline conceptual design in terms of operating capability and equipment is described, important factors to be considered in designing a system are examined, and preliminary cost data are provided. Factors associated with implementation are discussed and conclusions and recommendations are listed.

Vaisnys, A.

Thermal monitoring, measurement, and control system for a Volatile Condensable Materials (VCM) test apparatus

A thermal monitoring and control concept is described for a volatile condensable materials (VCM) test apparatus where electric resistance heaters are employed. The technique is computer based, but requires only proportioning ON/OFF relay control signals supplied through a programmable scanner and simple quadrac power controllers. System uniqueness is derived from automatic temperature measurements and the averaging of these measurements in discrete overlapping temperature zones. Overall control tolerance proves to be better than + or - 0.5 C from room ambient temperature to 150 C. Using precisely calibrated thermocouples, the method provides excellent temperature control of a small copper VCM heating plate at 125 + or - 0.2 C over a 24 hr test period. For purposes of unattended operation, the programmable computer/controller provides a continual data printout of system operation. Real time operator command is also provided for, as is automatic shutdown of the system and operator alarm in the event of malfunction.

Ives, R. E.

Rocket engine control and monitoring expert system

This paper focuses on the application of expert systems technology to the automatic detection, verification and correction of anomalous rocket engine operations through interfacing with an intelligent adaptive control system. The design of a reliable and intelligent propulsion control and monitoring system is outlined which includes the architecture of an Integrated Expert System (IES) serving as the core component. The IES functions include automatic knowledge acquisition, integrated knowledge base, and fault diagnosis and prediction methodology. The results of fault analysis and diagnostic techniques are presented for an example fault in the SSME main combustion chamber injectors.

Ali, Moonis

Monitoring the health of control system components

One characteristic of intelligent behavior is recognition of impaired capability. So an intelligent system should be able to monitor its own performance and determine when one of its components has failed - causing it to lose some degree of capability. This is especially important in autonomous operation which is one of the primary motivations for intelligent systems. This paper briefly reviews the principal approaches that have been suggested for monitoring control systems for failures of its sensors and actuators. The important characteristics of these methods are noted and two are selected for further consideration. These two methods, the failure detection filter and generalized parity relations, are described. Results of experiments are then given of detection and isolation of sensor failures using data taken on the Mini-Mast facility at the NASA Langley Research Center. The effects of certain design options are illustrated. The paper concludes with some observations about the general problem of monitoring the health of control systems.

Vander Velde, W. E.

A study of a space communication system for the control and monitoring of the electric distribution system. Volume 2: Supporting data and analyses

It is technically feasible to design a satellite communication system to serve the United States electric utility industry's needs relative to load management, real-time operations management, remote meter reading and to determine the costs of various elements of the system. The functions associated with distribution automation and control and communication system requirements are defined. Factors related to formulating viable communication concepts, the relationship of various design factors to utility operating practices, and the results of the cost analysis are discussed The system concept and several ways in which the concept could be integrated into the utility industry are described.

Vaisnys, A.

Monitoring and control of spacecraft systems using procedural reasoning

Research concerned with automating the monitoring and control of spacecraft systems is discussed. In particular, the application of SRI's Procedural Reasoning System (PRS) to the handling of malfunctions in the Reaction Control System (RCS) of NASA's Space Shuttle is examined. Unlike traditional monitoring and control systems, PRS is able to reason about and perform complex tasks in a very flexible and robust manner, somewhat in the manner of a human assistant. Using various RCS malfunctions as examples (including sensor faults, leaking components, multiple alarms, and regulator and jet failures), it is shown how PRS manages to combine both goal-directed reasoning and the ability to react rapidly to unanticipated changes in its environment. In conclusion, some important issues in the design of PRS are reviewed and future enhancements are indicated.

Georgeff, Michael P.