Structural Stability Study of Crystalline Silicotitanate Dispersed in Caustic Solutions for Extended Periods
The purpose of this study was to determine if pretreated engineered crystalline silicotitanate (CST) utilized in the Tank Cesium Closure Removal (TCCR) process would aggregate when contacted with sodium hydroxide (NaOH) or simulated tank waste solutions over an extended period. The aggregation of CST could be problematic for the TCCR process as it may lead to increased pressure drops across the columns, due to column plugging. Multiple prior studies have been completed on the agglomeration of CST stored in caustic simulants for prolonged periods showing evidence of clumping especially at elevated temperatures. For this study, pretreated CST was combined with various concentrations of sodium hydroxide and SRS simulant, in both glass and plastic storage containers, and monitored for an extended period. The samples were monitored for signs of agglomeration for a period of 8 months. After 7 months weak agglomeration was observed in the sample stored in SRS simulant, while no signs of clumping were observed in the samples stored in 2, 3, or 4 M NaOH. This is consistent with previous work where agglomeration of CST was not observed in simple salt solutions, only in simulants containing Al. In addition, the clumping observed for the sample stored in SRS simulant was not replicated in the duplicate sample stored in a plastic (as opposed to glass) vial, indicating leaching of Si from the glass may have contributed. It was also noted during the study that the solution above the CST stored in 4 M NaOH became opaque. The most likely cause of the opaque solution is the presence of micro-CST particles that may have been generated through sample handling, although this has not been confirmed by analysis.