Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE INDICATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Error in temperature measurements due to conduction along the sensors

When a sensor is embedded in a solid body to measure its internal temperature, any conduction to or from its sensing element may cause the indicated temperature to be different from the true temperature. This paper describes an analysis of the error caused by conduction when there is an arbitrary temperature distribution in the body along the sensor. The sensor is modeled as a cylindrical fin and the appropriate conduction equation is solved. The solution gives a correction for the error which depends on such parameters as, depth of immersion, thermocouple wire and insulation properties, contact between the sensor and the body, and temperature distribution in the body. The latter may not be known, but the measured temperature distribution can be used as a first approximation. The corrected value can then be used to obtain a better estimate of the error. The results show good agreement with experimental observations.

Singh, B. S.↗

Development and Utility of a Four-Channel Scanner for Wildland Fire Research and Applications

The Airborne Infrared Disaster Assessment System (AIRDAS) is a four-channel scanner designed and built at NASA-Ames for the specific task of supporting research and applications on fire impacts on terrestrial and atmospheric processes and also of serving as a vital instrument in the assessment of natural and man-induced disasters. The system has been flown on numerous airframes including the Navajo, King-Air, C0130, and Lear Jet 310 and a 206. The system includes a configuration composed of a 386 PC computer workstation, a non-linear detector amplifier, a sixteen-bit digitizer, dichroic filters, and Exabyte 8500 5Gb Tape output, VHS tape output, a Rockwell GPS and a 2-axis gyro. The AIRDAS system collects digital data in four wavelength regions, which can be filtered: band 1 (0.61-0.68 microns), band 2 (1.57-1.7 microns), band 3 (3.6-5.5 microns), and band 4 (5.5-13.0 microns), an FOV of 108 degrees, an IFOV of 2.62 mrads, and a digitized swath width of 720 pixels. The inclusion of the non-linear detector amplifier allows for the accurate measurement of emitted temperature from fires and hot spots. Lab testing of the scanner has indicated temperature assessments of 800 C without detector saturation. This has advantages over previous systems which were designed for thermal measurement of earth background temperatures, and were ill-equipped for accurate determination of high intensity conditions. The scanner has been flown successfully on data collection missions since 1992 in the western US as well as Brazil. These and other research and applications responses will be presented along with an assessment of future directions with the system.a

Ambrosia, Vincent G.↗

A reanalysis of the HCO(+)/HOC(+) abundance ratio in dense interstellar clouds

New theoretical and experimental results have prompted a reinvestigation of the HCO(+)/HOC(+) abundance ratio in dense interstellar clouds. These results pertain principally but not exclusively to the reaction between HOC(+) and H2, which was previously calculated by DeFrees et al. (1984) to possess a large activation energy barrier. New calculations, reported here, indicate that this activation energy barrier is quite small and may well be zero. In addition, experimental results at higher energy and temperature indicate strongly that the reaction proceeds efficiently at interstellar temperatures. If HOC(+) does indeed react efficiently with H2 in interstellar clouds, the calculated HCO(+)/HOC(+) abundance ratio rises to a substantially greater value under standard dense cloud conditions than is deduced via the tentative observation of HOC(+) in Sgr B2.

Jarrold, M. F.↗

Static force tests of a sharp leading edge delta-wing model at ambient and cryogenic temperatures with a description of the apparatus employed

A sharp leading edge delta-wing model was tested through an angle-of-attack range at Mach numbers of 0.75, 0.80, and 0.85 at both ambient and cryogenic temperatures in the Langley 1/3-meter transonic cryogenic tunnel. Total pressure was varied with total temperature in order to hold test Reynolds number constant at a given Mach number. Agreement between the aerodynamic data obtained at ambient and cryogenic temperatures indicates that flows with leading-edge vortex effects are duplicated properly at cryogenic temperatures. The test results demonstrate that accurate aerodynamic data can be obtained by using conventional force-testing techniques if suitable measures are taken to minimize temperature gradients across the balance and to keep the balance at ambient (warm) temperatures during cryogenic operation of the tunnel.

Kilgore, R. A.↗

Polyphase alloys as rechargeable electrodes in advanced battery systems

The rechargeability of electrochemical cells is often limited by negative electrode problems. These may include loss of capacity, increased impedance, macroscopic shape change, dendrite growth, or a tendency for filamentary or whisker growth. In principle, these problems can be reduced or eliminated by the use of alloys that undergo either displacement or insertion reactions at reactant species activities less than unity, rather than pure elements. The fundamental reasons for some of these problems with elemental electrodes, as well as the basic principles involved in the different behavior of alloys, are briefly discussed. More information is now available concerning the thermodynamic and kinetic properties of a number of alloys of potential interest for use as electrodes in elevated temperature lithium battery systems. Recent results have extended these results down to ambient temperatures, indicating that some such materials may be of interest for use with new low temperature molten salt electrolytes, or with organic solvent electrolytes. The all solid mixed conductor matrix concept is also reviewed.

Huggins, Robert A.↗

Method development for compensating temperature effects in pressure sensitive paint measurements

Pressure sensitive luminescent paints (PSP) have recently emerged as a viable technique for aerodynamic pressure measurements. The technique uses a surface coating which contains probe molecules that luminesce when excited by light of an appropriate wavelength. The photoluminescence of these materials is known to be quenched by the presence of molecular oxygen. Since oxygen is a fixed mole fraction of the air, the coating's luminescence intensity varies inversely with air pressure. Digital imaging of the luminescence varying across a coated surface produces a pressure distribution map over that surface. One difficulty encountered with this technique is the temperature effect on the luminescence intensity. Present PSP formulations have significant sensitivity to temperature. At the moment, the most practical way of correcting for temperature effects is to calibrate the paint in place at the operating temperatures by using a few well-placed pressure taps. This study is looking at development of temperature indicating coatings that can be applied and measured concurrently with PSP, and use the temperature measurement to compute the correct pressure. Two methods for this dual paint formulation are proposed. One method will use a coating that consists of temperature sensitive phosphors in a polymer matrix. This is similar in construction to PSP, except that the probe molecules used are selected primarily for their temperature sensitivity. Both organic phosphors (e.g., europium thenoyltrifluoroacetonate, bioprobes) and inorganic phosphors (e.g., Mg4(F)GeO6:Mn, La2O2S:Eu, Radelin Type phosphors, Sylvania Type phosphors) will be evaluated for their temperature sensing potential. The next method will involve a novel coating composing of five membered heterocyclic conducting polymers which are known to show temperature dependent luminescence (e.g., poly(3-alkylthiopene), poly(3-alkylselenophene), poly(3-alkylfuran)). Both methods will involve applying a bottom layer of temperature sensitive coating followed by a top coating of PSP. An oxygen-impermeable polymer can be used as the temperature sensitive coating matrix, or it can be layered in between the coatings to prevent oxygen quenching of the bottom coating's luminescence. The probe molecules of the coatings will be excited by a broad band of light, with the different emissions detected and measured at their distinct wavelengths. Developmental research of these coatings is still in progress; however, preliminary results look very promising.

Demandante, Carlo Greg N.↗

Analysis of Saturn's Thermal Emission at 2.2-cm Wavelength: Spatial Distribution of Ammonia Vapor

This work focuses on determining the latitudinal structure of ammonia vapor in Saturn's cloud layer near 1.5 bars using the brightness temperature maps derived from the Cassini RADAR (Elachi et al., 2004) instrument, which works in a passive mode to measure thermal emission from Saturn at 2.2-cm wavelength. We perform an analysis of five brightness temperature maps that span epochs from 2005 to 2011, which are presented in a companion paper by Janssen et al. (2013a, this issue). The brightness temperature maps are representative of the spatial distribution of ammonia vapor, since ammonia gas is the only effective opacity source in Saturn's atmosphere at 2.2-cm wavelength. Relatively high brightness temperatures indicate relatively low ammonia relative humidity (RH), and vice versa. We compare the observed brightness temperatures to brightness temperatures computed using the Juno atmospheric microwave radiative transfer (JAMRT) program which includes both the means to calculate a tropospheric atmosphere model for Saturn and the means to carry out radiative transfer calculations at microwave frequencies. The reference atmosphere to which we compare has a 3x solar deep mixing ratio of ammonia (we use 1.352x10(exp -4) for the solar mixing ratio of ammonia vapor relative to H2; see Atreya, 2010) and is fully saturated above its cloud base. The maps are comprised of residual brightness temperatures-observed brightness temperature minus the model brightness temperature of the saturated atmosphere.

Atmospheres↗

Experimental Investigation of an Air-Cooled Turbine Operating in a Turbojet Engine at Turbine Inlet Temperatures up to 2500 F

An experimental investigation was made of an air-cooled turbine at average turbine inlet temperatures up to 2500 F. A modified production-model 12-stage axial-flow-compressor turbojet engine operating in a static sea-level stand was used as the test vehicle. The modifications to the engine consisted of the substitution of special combustor and turbine assemblies and double-walled exhaust ducting for the standard parts of the engine. All of these special parts were air-cooled to withstand the high operating temperatures of the investigation. The air-cooled turbine stator and rotor blades were of the corrugated-insert type. Leading-edge tip caps were installed on the rotor blades to improve leading-edge cooling by diverting the discharge of coolant to regions of lower gas pressure toward the trailing edge of the blade tip. Caps varying in length from 0.15- to 0.55-chord length were used in an attempt to determine the optimum cap length for this blade. The engine was operated over a range of average turbine inlet temperatures from about 1600 to about 2500 F, and a range of average coolant-flow ratios of 0.012 to 0.065. Temperatures of the air-cooled turbine rotor blades were measured at all test conditions by the use of thermocouples and temperature-indicating paints. The results of the investigation indicated that this type of blade is feasible for operation in turbojet engines at the average turbine inlet temperatures and stress levels tested(maximums of 2500 F and 24,000 psi, respectively). An average one-third-span blade temperature of 1300 F could be maintained on 0.35-chord tip cap blades with an average coolant-flow ratio of about 0.022 when the average turbine inlet temperature was 2500 F and cooling-air temperature was about 260 F. All of the leading-edge tip cap lengths improved the cooling of the leading-edge region of the blades, particularly at low average coolant-flow ratios. At high gas temperatures, such parts as the turbine stator and the combustor liners are likely to be as critical as the turbine rotor blades.

Cochran, Reeves P.↗

Electrical properties of dry rocks

The mechanism by which atmospheric moisture affects the conductivity and dielectric constant of rock specimens was studied in time and frequency domains. It is suggested that adsorbed water molecules alter the surface conductivity in a manner similar to that observed in semiconductors and insulators. Powdered basalts show a low-frequency dispersion produced by the atmospheric moisture remaining in the pore system of the sample in a high vacuum; this effect is attributed to isolated adsorption centers. Simulated lunar permafrost at 100 K and a vacuum of 10 to the -8th power torr together with data on lunar samples contaminated with atmospheric moisture and the dielectric properties of ice at various temperatures indicate that, if permafrost exists in the moon it should present a relaxation peak at approximately 300 Hz; for temperatures up to 263 K it may go up to 20 KHz. It is concluded that in order to have electrical steady state conditions in rock samples it is necessary to have volume charge accumulations at interfaces within the sample and at the electrode sample interface. A method for measuring heterogeneous dielectrics with non-negligible ohmic and dielectric conductivities is proposed and experimentally verified.

Morrison, H.↗

Temperatures and Composition in the Saturn System from Cassini CIRS

We summarize recent observations by the Composite Infrared Spectrometer of Saturn, its rings, Titan, and the icy satellites. Limb observations of Saturn show vertical oscillations of temperatures and zonal-wind shears in the equatorial region that may be related to a temporal oscillation similar to the terrestrial QBO and Jupiter's QQO. There is also evidence of subsidence at mid-northern latitudes driven by the equatorial activity. Nadir-viewing observations show compact warm spots in the troposphere and stratosphere at both (summer and winter) poles, likely associated with subsidence. Observations of Titan have defined better the characteristics of the northern winter polar vortex, with 190 m/s winds surrounding a cold atmosphere at 1 microbar. The very warm polar stratopause at 10 microbar and the enhanced abundances of organic compounds suggest subsidence within the vortex. Analysis of the zonal structure in temperature indicates that the stratospheric zonal winds rotate about an axis that is displaced approximately 4.1 deg from the IAU pole. Additional flybys, including a close one in March 2008, continue to characterize the endogenic activity in Enceladus s south polar region. Temperature maps of bright and dark terrains on Iapetus indicate that its ice is approximately stable to sublimation in the bright regions and highly unstable in the dark regions. Thermal mapping of Saturn s rings continues to constrain their composition, and observations at different solar phase angles, spacecraft elevations, solar elevations, and local hour angles have elucidated the effects of ring-particle shadowing and vertical motions on the thermal structure, and revealed the presence of small-scale structure associated with self-gravity wakes.

Flasar, F. Michael↗

Application of a gripping system to test a uniaxial graphite fiber reinforced composite /PMR 15/Celion 6000/ in tension at 316 C

A gripping system has been developed to test uniaxial, 0 deg orientation PMR 15/Celion 6000 composites at elevated temperatures. The method involves compression of grit-blasted laminate between grit-blasted metal to give a non-slipping interface for load transfer. Tensile testing at both 316 C and room temperature indicated that deformation was elastic to fracture and that the variation in tensile properties for one laminate is the same as that for several panels. In addition, the tensile properties for uniaxial PMR 15/Celion 6000 are identical at 316 C and room temperature. For nominally 51 volume percent fiber, the elastic modulus is 119.6 GPa, the fracture stress is 1370 MPa, and the strain to fracture is about 1.15 percent. In addition, data are presented which indicate that the gripping system can be used for long term, elevated temperature testing of composite materials.

Whittenberger, J. D.↗

Cathodoluminescence of InP

Cathodoluminescence studies were carried out on p-type InP having carrier concentrations ranging from 7.2 x 10 to the 16th to 7.4 x 10 to the 18th per cu cm in the temperature range of 80-580 K. It was found that low-temperature spectra exhibited peaks at 1.41 and 1.38 eV. These peaks were attributed to band-to-band and band-acceptor transitions, respectively. The dependence of the band-to-band peak on temperature was used to extend knowledge of the temperature dependence of the energy gap of InP to 550 K. It was shown that the half-width of the cathodoluminescence peak can be used for the determination of carrier concentration and carrier-concentration inhomogeneities in the material. The variations of the cathodoluminescence peak height with temperature indicated the possibility of Auger recombination for high carrier concentrations (7.4 x 10 to the 18th per cu cm) at temperatures above 450 K.

Gatos, C. H.↗

Temperature-Dependent Changes in the Normal Albedo of the Lunar Surface at 1064 nm

Over the extreme temperature variations experienced in a single lunar day (∆T≈300 K), particular minerals common to the lunar surface show spectral changes at near-infrared wavelengths in laboratory settings (Singer and Roush, 1985; Roush and Singer, 1986, 1987). Variations in temperature can cause variations in the size and shape of crystallographic sites, which control the position, shape, and depth of crystal field absorptions. At an observation wavelength of 1064 nm, the Lunar Orbiter Laser Altimeter (LOLA) should be highly sensitive to temperature-dependent changes of orthopyroxene. Here we analyze temperature-dependent spectral changes of the lunar surface as measured from orbit by LOLA. We couple LOLA measurements of normal albedo with measurements of surface temperature from the Diviner Lunar Radiometer Experiment, analyzing the maria and highlands terranes between ±50° in 1°x1° spatial bins. We provide the first evidence of temperature-dependent spectral changes on the lunar surface from orbital observations, finding that the majority of the lunar surface between 50°N and 50°S demonstrates a small, yet measurable, negative change in normal albedo at 1064 nm with temperature (-∆R/∆T). The measurable effect is on the order of a few percent change in reflectance per ~80 K, indicating temperature changes do not have a large effect on measurements of albedo at the sensitivity of the LOLA instrument. Stronger -∆R/∆T values tend to be associated with the maria, and regions with elevated orthopyroxene levels. Our results suggest that single-wavelength lasers may be powerful tools for understanding the distribution of particular minerals on the lunar surface.

Ariel N Deutsch↗

Heat Transfer Experiments in the Internal Cooling Passages of a Cooled Radial Turbine Rotor

An experimental study was conducted (1) to experimentally measure, assess and analyze the heat transfer within the internal cooling configuration of a radial turbine rotor blade and (2) to obtain heat transfer data to evaluate and improve computational fluid dynamics (CFD) procedures and turbulent transport models of internal coolant flows. A 1.15 times scale model of the coolant passages within the NASA LERC High Temperature Radial Turbine was designed, fabricated of Lucite and instrumented for transient beat transfer tests using thin film surface thermocouples and liquid crystals to indicate temperatures. Transient heat transfer tests were conducted for Reynolds numbers of one-fourth, one-half, and equal to the operating Reynolds number for the NASA Turbine. Tests were conducted for stationary and rotating conditions with rotation numbers in the range occurring in the NASA Turbine. Results from the experiments showed the heat transfer characteristics within the coolant passage were affected by rotation. In general, the heat transfer increased and decreased on the sides of the straight radial passages with rotation as previously reported from NASA-HOST-sponsored experiments. The heat transfer in the tri-passage axial flow region adjacent to the blade exit was relatively unaffected by rotation. However, the heat transfer on one surface, in the transitional region between the radial inflow passage and axial, constant radius passages, decreased to approximately 20 percent of the values without rotation. Comparisons with previous 3-D numerical studies indicated regions where the heat transfer characteristics agreed and disagreed with the present experiment.

Johnson, B. V.↗

Gas turbine combustor stabilization by heat recirculation

The feasibility of heat recirculation for stabilization of lean mixtures and emission reduction has been studied in detail for a typical aircraft gas turbine combustor. Thermodynamic calculations have indicated temperature and heat recirculation rates for operation of the combustor over a range of combustion zone equivalence ratios and for varying modes of desired engine operation. Calculations indicate the feasibility of stabilizing the combustion zone at equivalence ratios as low as 0.2 with achievable heat recirculation rates. Detailed chemical kinetic calculations suggest that combustor heat release is maintained with reaction completion substantially before the NO forming reactions, even though CO is rapidly oxidized in this same region.

Ganji, A.↗

Masking of the circadian rhythms of heart rate and core temperature by the rest-activity cycle in man

Experiments were conducted to estimate the magnitude of the masking effect produced in humans by alternate periods of physical activity and rest or sleep on the circadian rhythms of heart rate and core temperature. The heart rate, rectal temperature, and nondominant wrist activity were monitored in 12 male subjects during 6 days of normal routine at home and during 6 days of controlled bed-rest regimen. The comparisons of averaged waveforms for the activity, heart rate, and temperature indicated that about 45 percent of the range of the circadian heart rate rhythm during normal routine and about 14 percent of the range of the circadian temperature rhythm were attributable to the effects of activity. The smaller effect of activity on the temperature rhythm may be partially attributable to the fact that core temperature is being more rigorously conserved than heart rate, at least during moderate exercise.

Gander, Philippa H.↗

Effects of acceleration on thermoregulatory responses of unanesthetized rats

An experimental study was carried out to examine the thermoregulatory responses of rats to step changes in ambient temperature during centrifugation. Attention is focused on the analysis of problems as to whether the ability of rats to regulate body temperature during one hour of cold exposure is altered by increasing the acceleration field to 2G, whether prior environmental conditioning can affect the temperature response to the combined stressors of acceleration and cold, and whether the orientation of the animal in the acceleration field modifies the temperature response. The finding that the decline in colonic temperature is accompanied by parallel changes in hypothalamic and spinal cord temperatures indicates that the decreasing heat production with increasing heat loss is an atypical thermoregulatory response of these animals to cooling. Mechanical forces acting on the brain may underline the temperature decrease when inverting the animal during acceleration.

Fuller, C. A.↗