Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Experience with advanced instrumentation in a hot section cascade

The Lewis Research Center gas turbine Hot Section Test Facility was developed to provide a real engine environment with known boundary conditions for the aerothermal performance evaluation and verification of computer design codes. This verification process requires experimental measurements in a hostile environment. The research instruments used in this facility are presented, and their characteristics and how they perform in this environment are discussed. The research instrumentation consisted of conventional pressure and temperature sensors, as well as thin-film thermocouples and heat flux gages. The hot gas temperature was measured by an aspirated temperature probe and by a dual-element, fast-response temperature probe. The data acquisition mode was both steady state and time dependent. These experiments were conducted over a wide range of gas Reynolds numbers, exit gas Mach numbers, and heat flux levels. This facility was capable of testing at temperatures up to 1600 K, and at pressures up to 18 atm. These corresponded to an airfoil exit Reynolds number range of 0.5 x 10(6) to 2.5 x 10(6) based on the airfoil chord of 5.55 cm. The results characterize the performance capability and the durability of the instrumentation. The challenge of making measurements in hostile environments is also discussed. The instruments exhibited more than adequate durability to achieve the measurement profile. About 70 percent of the thin-film thermocouples and the dual-element temperature probe survived several hundred thermal cycles and more than 35 hr at gas temperatures up to 1600 K. Within the experimental uncertainty, the steady-state and transient heat flux measurements were comparable and consistent over the range of Reynolds numbers tested.

Yeh, Frederick C.↗

Temperature Measurement Aid

NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.

Source record↗

Program for an improved hypersonic temperature-sensing probe

Under a NASA Dryden-sponsored contract in the mid 1960s, temperatures of up to 2200 C were successfully measured using a fluid oscillator. The current program, although limited in scope, explores the problem areas which must be solved if this technique is to be extended to 10,000 R. The potential for measuring extremely high temperatures, using fluid oscillator techniques, stems from the fact that the measuring element is the fluid itself. The containing structure of the oscillator need not be brought to equilibrium temperature with with the fluid for temperature measurement, provided that a suitable calibration can be arranged. This program concentrated on review of high-temperature material developments since the original program was completed. Other areas of limited study included related pressure instrumentation requirements, dissociation, rarefied gas effects, and analysis of sensor time response.

Reilly, Richard J.↗

The measurement of the ground wind structure at Wallops Island

The mean and turbulence characteristics of the surface wind measured near the Atlantic coast were measured. The experimental data were acquired from a 76 meter tall instrumented micrometeorological tower. Mean wind and turbulence measurements were made with two types of instrumentation consisting of cup vane and temperature probes, primarily used for mean profile measurements of velocity and temperature respectively. The second system, a hot film and thermocouple system, was used for measurement of turbulence variances and covariances and spectra. The cup vane system was used to acquire data from all wind directions, while the hot film system was primarily used for turbulence measurements from the two prevailing wind directions, south and northwest. The micrometeorological tower is a self standing nonguyed tower with five working platforms at 15.2m (50 ft.) intervals, with cup vane and aspirated temperature probes mounted at each platform.

Tielman, H. W.↗

Sound transmission through a high-temperature acoustic probe tube

An investigation was conducted of acoustic transmission through a tube subjected to an intense thermal gradient along its axis. The results are of interest in the interpretation of acoustic data from probe tube configurations designed to measure fluctuating pressures in high temperature environments. The measured transfer function across a localized heated region in the tube was compared to a computed transfer function based on a theoretical analysis of propagation through strong temperature gradients. Over the frequency range 0.4 kHz to 6.0 kHz, generally good agreement was obtained between the measured and calculated attenuation across the heated region with some discrepancy occurring at the attenuation minima. Agreement between measured and calculated phase difference was excellent to within the measurement resolution.

Parrott, Tony L.↗

An unusual interplanetary event - Encounter with a comet?

The possibility that the slow rise to a sharp maximum and then decay surrounding a strong current sheet observed in the Venus magnetic field 0.72 AU from the sun was caused by passage of Venus through the wake of an active comet is examined. Data were also gathered by the ISEE 3 satellite magnetometer at 0.99 AU 25 h, 20 min later, a delay corresponding to the transit time for the solar wind. No shock structures bounded the phenomenon. The data indicate the presence of a small body in a much larger field of interaction and the magnetometer, solar wind probe, and electron temperature probe support a behavior similar to a planetary magnetosheath. The observed He structure in interplanetary space ruled out a solar wind source, while consideration of the magnetic equator and magnetic pole suggest that an unknown comet passed through the region between the sun and Venus at a distance where the effects would not be detected at earth.

Russell, C. T.↗

An experimental study of the effect of streamwise vorticity on supersonic mixing enhancement

An initial experimental study of the effect of streamwise vorticity on supersonic turbulent mixing has been carried out. A Mach 3 streamwise vortex is generated using a strutmounted swirl injector and is injected into a Mach 3.5 freestream. The resulting flowfield is investigated using both five-hole angularity probe and total temperature probe surveys. The results are compared to identical experiments with a baseline, swirl-free Mach 3 jet. Laser Light Sheet (LLS) images are used to observe the mixing phenomena. The entrainment of energy and mass is used to evaluate the degree of mixing between the two streams for both the vortex and jet cases. The results reveal that streamwise vorticity does lead to a modest mixing enhancement of about 34 percent for the conditions tested.

Naughton, J. W.↗

CFD analysis to optimize a design modification of BSMT

The Bearings, Seals and Materials Tester (BSMT) is a test article being used at MSFC to evaluate the performance of conventional rolling contact bearings. Pressure differentials between the BSMT inlet and exit cavities are found to cause large parasitic axial loads on the bearing-carrier walls. These parasitic loads, besides being detrimental to the life of bearings, make the testing and evaluation of bearing performance very difficult, and need to be eliminated if at all possible. The objectives of this study are to estimate the hydrodynamic loads on the bearings and to recommend feasible design modifications for BSMT to eliminate the parasitic loads. Three-dimensional computational analyses of inlet and exit cavities in their baseline configuration were performed with REFLEQS which is an advanced finite-volume Navier-Stokes code. Computations were performed with and without a 1/4 inch diameter temperature probe included in each of the cavities. The results of the analyses indicate that the temperature probes substantially alter the flow field and reduce the pressure drop/rise in the cavities. The overall pressure drop across the tester compares quite well with the measurements.

Ratcliff, Mark↗

Electron emission from nickel-alloy surfaces in cesium vapor

An experimental apparatus and measurement techniques are described for measuring the thermionic emission from cesium-activated materials having adequate high-temperature properties such as creep strength and corrosion resistance, which might ultimately reduce the cost of thermionic converters. The electron emission characteristics are measured for nickel, Inconel 600, and Hastelloy X probes with a 412 K cesium reservoir. It is found that the nickel alloys exhibit a peak electron emission 1.4 to 2.1 times greater than pure nickel. Both the Inconel and the Hastelloy samples have work functions of 1.64 eV at peak emission. The minimum cesiated work functions are estimated to be 1.37 eV for Inconel at a probe temperature of 750 K and 1.4 eV for Hastelloy at a probe temperature of 665 K. The bare work functions for both alloys is estimated to be about the same as for pure nickel, 4.8 eV.

Manda, M.↗

Probing room temperature indirect and minimum direct band gaps of h-BN

Abstract Hexagonal boron nitride (h-BN) has attracted considerable interest as an ultrawide bandgap (UWBG) semiconductor. Experimental studies focused on the detailed near band-edge structure of h-BN at room temperature are still lacking. We report a direct experimental measurement of the near band-edge structure performed on h-BN quasi-bulk wafers via photocurrent excitation spectroscopy (PES). PES resolved the band-to-band transitions near M- and K-points in the Brillion zone (BZ), from which the room temperature indirect band gap of E g M K ∼6.02 eV, minimum direct bandgap at M-point of E g M = 6.36 eV and next lowest direct energy bandgap at K-point of E g K = 6.56 eV , have been simultaneously determined for the first time experimentally. The measured energy differences between K- and M-points in the conduction band minimum (CBM) and valence band maximum (VBM) are Δ E C M K = 0.54 eV and Δ E V M K = 0.34 eV, respectively, in good agreement with the calculation results. Significantly differing from its III-nitride wurtzite counterparts, in which only electrons and holes in the conduction and valence band extremes at the Γ-point are predominantly involved in the optical and transport processes, the results highlighted that charge carriers associated with both M- and K-valleys control to the optical excitation, recombination and charge transport processes in h-BN.

Physics↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

Measurement of Turbulent Pressure and Temperature Fluctuations in a Gas Turbine Combustor

The present research concerns the development of high-frequency pressure and temperature probes and related instrumentation capable of performing spectral characterization of unsteady pressure and temperature fluctuations over the 0.05 20 kHz range, at the exit of a gas turbine combustor operating at conditions close to nominal ones for large power generation turbomachinery. The probes used a transient technique pioneered at Oxford University; in order to withstand exposure to the harsh environment the probes were fitted on a rapid injection and cooling system jointly developed by Centrospazio CPR and Syracuse University. The experimental runs were performed on a large industrial test rig being operated by ENEL Produzione. The achieved results clearly show the satisfactory performance provided by this diagnostic tool, even though the poor location of the injection port prevented the tests from yielding more insight of the core flow turbulence characteristics. The pressure and temperature probes survived several dozen injections in the combustor hot jet, while consistently providing the intended high frequency performance. The apparatus was kept connected to the combustor during long duration firings, operating as an unobtrusive, self contained, piggy-back experiment: high frequency flow samplings were remotely recorded at selected moments corresponding to different combustor operating conditions.

Passaro, Andrea↗