At least 55 records · Page 3

A space simulation test chamber development for the investigation of radiometric properties of materials

The design, fabrication, and preliminary utilization of a thermal vacuum space simulation facility are discussed. The facility was required to perform studies on the thermal radiation properties of materials. A test chamber was designed to provide high pumping speed, low pressure, a low photon level radiation background (via high emissivity, coated, finned cryopanels), internal heat sources for rapid warmup, and rotary and linear motion of the irradiated materials specimen. The radiation detection system consists of two wideband infrared photoconductive detectors, their cryogenic coolers, a cryogenic-cooled blackbody source, and a cryogenic-cooled optical radiation modulator.

Enlow, D. L.

Probability of Decompression Sickness and Venous Gas Emboli from 49 NASA Hypobaric Chamber Tests with Reference to Exploration Atmosphere

Introduction: Decompression sickness (DCS) is a complex biophysical event; it combines human perception of pain, for instance, and the presence of a gas phase in the tissues. Living tissues are complex and dynamic. Micronuclei and later bubbles may or may not form given what appears to be the same conditions. Even when bubbles grow, symptoms may or may not develop under what appears to be the same conditions. Therefore, at this time it is appropriate to consider DCS as a probabilistic rather than a deterministic event. Methods: Probabilistic models about hypobaric DCS and venous gas emboli (VGE) require a large amount of quality research data, a definition of decompression dose using physical and physiologic variables, and a flexible analytical approach that can quantify the association between each outcome and all covariates of interest (assuming independence between DCS and VGE) and then ultimately be extended to acknowledge dependencies between DCS and VGE. Our DCS and VGE data are from 1,031 hypobaric decompressions from 1983 to 2016. A total of 577 humans participated in 49 hypobaric chamber tests to evaluate denitrogenation procedures used by astronauts in the Space Shuttle and International Space Station programs. We defined decompression dose as the ratio of computed nitrogen tension in a theoretical 360-minute half-time compartment to ambient pressure, which accounts for denitrogenation and exposure pressure as well as explanatory variables such as age, sex, body mass index, and the presence or absence of ambulation as part of exercise at the exposure pressure. A parametric survival model, using a log-logistic distribution, was used to quantify the time to development of DCS, VGE, and Grade IV VGE. Results: Our survival estimates are applicable to simple hypobaric decompressions, such as depressurizations in 5 to 30 minutes to exposure pressures between 4 and 10 pounds per square inch absolute (psia) and after minutes to hours of denitrogenation, either under resting or exercise conditions to accelerated denitrogenation. The regressions are applicable to exposures between 2 to 6 hours and under conditions of ambulation or no ambulation as part of exercise at the test pressure. We estimate that an exposure to 4.3 psia with simulated extravehicular activity (EVA) that includes ambulation after equilibration to the exploration atmosphere at 8.2 psia with a 34% oxygen atmosphere will result in 3.1% DCS (1.8% to 5.2 95% confidence interval), 23.2% VGE (16.7 to 31.2%), and 8.5% Grade IV VGE (4.7 to 14.7%) in equal samples of men and women exposed for 6 hours. Discussion: Probabilistic models for DCS, VGE, and Grade IV VGE can be used to inform those that plan future EVAs. Their applications are useful to quantify the risk of DCS and VGE in astronauts that perform EVAs in low-pressure space suits while in space or while exploring the surfaces of the moon or Mars.

Johnny Conkin

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division’s Systems Test Branch at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), and Infrared (IR) lamps. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Kaixin Cui

Plasma chamber testing of APSA coupons for the SAMPIE flight experiment

Different blanket materials and mounting techniques have been used to build 12 Advanced Photovoltaic Solar Array cell coupons for NASA's Solar Array Module Plasma Interactions Experiment. Ground testing of these coupons in a plasma chamber revealed significant differences among them in plasma current collection; while the Kapton-H coupon exhibited current collection consistent with the exposed interconnects, the other two coupon types tested experienced anomalously large collection currents. This may be due to enhanced plasma sheaths supported by the weakly conducting C and Ge employed in these coupons.

Hillard, G. B.

High-pressure calorimeter chamber tests for liquid oxygen/kerosene (LOX/RP-1) rocket combustion

An experimental program was conducted to investigate the rocket combustion and heat transfer characteristics of liquid oxygen/kerosene (LOX/RP-1) mixtures at high chamber pressures. Two water-cooled calorimeter chambers of different combustion lengths were tested using 37- and 61-element oxidizer-fuel-oxidizer triplet injectors. The tests were conducted at nominal chamber pressures of 4.1, 8.3, and 13.8 MPa abs (600, 1200, and 2000 psia). Heat flux Q/A data were obtained for the entire calorimeter length for oxygen/fuel mixture ratios of 1.8 to 3.3. Test data at 4.1 MPa abs compared favorably with previous test data from another source. Using an injector with a fuel-rich outer zone reduced the throat heat flux by 47 percent with only a 4.5 percent reduction in the characteristic exhaust velocity efficiency C* sub eff. The throat heat transfer coefficient was reduced approximately 40 percent because of carbon deposits on the chamber wall.

Masters, Philip A.

Plasma chamber testing of APSA coupons for the SAMPIE flight experiment

Among the solar cell technologies to be tested in space as part of the Solar Array Module Plasma Interactions Experiment (SAMPIE) will be the Advanced Photovoltaic Solar Array (APSA). Several prototype twelve cell coupons were built for NASA using different blanket materials and mounting techniques. The first conforms to the baseline design for APSA which calls for the cells to be mounted on a carbon loaded Kapton blanket to control charging in GEO. When deployed, this design has a flexible blanket supported around the edges. A second coupon was built with the cells mounted on Kapton-H, which was in turn cemented to a solid aluminum substrate. A final coupon was identical to the latter but used germanium coated Kapton to control atomic oxygen attack in LEO. Ground testing of these coupons in a plasma chamber showed considerable differences in plasma current collection. The Kapton-H coupon demonstrated current collection consistent with exposed interconnects and some degree of cell snapover. The other two coupons experienced anomalously large collection currents. This behavior is believed to a consequence of enhanced plasma sheaths supported by the weakly conducting carbon and germanium used in these coupons. The results reported here are the first experimental evidence that the use of such materials can result in power losses to high voltage space power systems.

Hillard, G. Barry

Task 12 data dump (phase 2) OME integrated thrust chamber test report

The characteristics and performance of the orbit maneuvering engine for the space shuttle are discussed. Emphasis is placed on the regeneratively cooled thrust chamber of the engine. Tests were conducted to determine engine operating parameters during the start, shutdown, and restart. Characteristics of the integrated thrust chamber and the performance and thermal conditions for blowdown operation without supplementary boundary layer cooling were investigated. The results of the test program are presented.

Tobin, R. D.

Modification of a very large thermal-vacuum test chamber for ionosphere and plasmasphere simulation

No large-volume chamber existed which could simulate the ion and electron environment of near-earth space. A very large thermal-vacuum chamber was modified to provide for the manipulation of the test volume magnetic field and for the generation and monitoring of plasma. Plasma densities of 1 million particles per cu cm were generated in the chamber where a variable magnetic flux density of up to 0.00015 T (1.5 gauss) was produced. Plasma temperature, density, composition, and visual effects were monitored, and plasma containment and control were investigated. Initial operation of the modified chamber demonstrated a capability satisfactory for a wide variety of experiments and hardware tests which require an interaction with the plasma environment. Potential for improving the quality of the simulation exists.

Pearson, O. L.

Thermal System Upgrade of the Space Environment Simulation Test Chamber

The paper deals with the refurbishing and upgrade of the thermal system for the existing thermal vacuum test facility, the Space Environment Simulator, at NASA's Goddard Space Flight Center. The chamber is the largest such facility at the center. This upgrade is the third phase of the long range upgrade of the chamber that has been underway for last few years. The first phase dealt with its vacuum system, the second phase involved the GHe subsystem. The paper describes the considerations of design philosophy options for the thermal system; approaches taken and methodology applied, in the evaluation of the remaining "life" in the chamber shrouds and related equipment by conducting special tests and studies; feasibility and extent of automation, using computer interfaces and Programmable Logic Controllers in the control system and finally, matching the old components to the new ones into an integrated, highly reliable and cost effective thermal system for the facility. This is a multi-year project just started and the paper deals mainly with the plans and approaches to implement the project successfully within schedule and costs.

Desai, Ashok B.

DBD Plasma Actuators for Flow Control in Air Vehicles and Jet Engines - Simulation of Flight Conditions in Test Chambers by Density Matching

Dielectric Barrier Discharge (DBD) Plasma actuators for active flow control in aircraft and jet engines need to be tested in the laboratory to characterize their performance at flight operating conditions. DBD plasma actuators generate a wall-jet electronically by creating weakly ionized plasma, therefore their performance is affected by gas discharge properties, which, in turn, depend on the pressure and temperature at the actuator placement location. Characterization of actuators is initially performed in a laboratory chamber without external flow. The pressure and temperature at the actuator flight operation conditions need to be simultaneously set in the chamber. A simplified approach is desired. It is assumed that the plasma discharge depends only on the gas density, while other temperature effects are assumed to be negligible. Therefore, tests can be performed at room temperature with chamber pressure set to yield the same density as in operating flight conditions. The needed chamber pressures are shown for altitude flight of an air vehicle and for jet engines at sea-level takeoff and altitude cruise conditions. Atmospheric flight conditions are calculated from standard atmosphere with and without shock waves. The engine data was obtained from four generic engine models; 300-, 150-, and 50-passenger (PAX) aircraft engines, and a military jet-fighter engine. The static and total pressure, temperature, and density distributions along the engine were calculated for sea-level takeoff and for altitude cruise conditions. The corresponding chamber pressures needed to test the actuators were calculated. The results show that, to simulate engine component flows at in-flight conditions, plasma actuator should be tested over a wide range of pressures. For the four model engines the range is from 12.4 to 0.03 atm, depending on the placement of the actuator in the engine. For example, if a DBD plasma actuator is to be placed at the compressor exit of a 300 PAX engine, it has to be tested at 12.4 atm for takeoff, and 6 atm for cruise conditions. If it is to be placed at the low-pressure turbine, it has to be tested at 0.5 and 0.2 atm, respectively. These results have implications for the feasibility and design of DBD plasma actuators for jet engine flow control applications. In addition, the distributions of unit Reynolds number, Mach number, and velocity along the engine are provided. The engine models are non-proprietary and this information can be used for evaluation of other types of actuators and for other purposes.

Ashpis, David E.

Accelerated Solar-UV Test Chamber

Medium-pressure mercury-vapor lamps provide high ratio of ultraviolet to total power. Chamber for evaluating solar-ultraviolet (UV) radiation damage permits accelerated testing without overheating test specimens.

Gupta, A.

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater plates. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA) suits

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

spacesuit arms

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)