Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMIONIC CATHODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface studies of thermionic cathodes and the mechanism of operation of an impregnated tungsten cathode

The surface properties of conventional impregnated cathodes were investigated by the use of Auger spectroscopy and work function measurements, and these were compared with a synthesized barium or barium oxide coated tungsten surface. The barium and barium oxide coated surfaces were prepared by evaporating barium onto a tungsten surface that can be heated to elevated temperatures. Multilayer or monolayer coverages can be investigated using this technique. The results of this study show that the surface of an impregnated tungsten cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on partially oxidized tungsten, using the criteria of identical Auger patterns and work functions. Desorption measurements of barium from a tungsten surface were also made. These results in conjunction with Auger and work function data were interpreted to show that throughout most of its life an impregnated cathode operating in the range of 1100 C has a partial monolayer rather than a monolayer of barium on its surface.

Forman, R.↗

Use of Auger spectroscopy in the evaluation of thermionic cathodes

Auger spectroscopy has been used to evaluate the properties of 'good' and 'poor' impregnated tungsten cathodes used in high-power microwave wave tubes. The results were interpreted to analyze failure modes in cathodes removed from TWT's because of poor emission characteristics. Most of the poor cathodes evaluated in this program were obtained from fabricated electron guns that had been employed and discarded from the 200-W TWT tubes developed for the Communication Technology Satellite program. The results of these measurements have shown there are at least two types of failure modes that one observes with poor cathodes. They are (1) chemical contamination of the cathode surface and (2) low partial layer barium coverage of the cathode surface.

Forman, R.↗

Thermionic cathode life test studies

An update on the life testing of commerical, high current density impregnated tungsten cathodes is presented. The B-type cathodes, operated at a current density of 2 A/cm2 and a cathode temperature of 1100 C have now been run satisfactorily for more than four years. The M-cathode, at the same current density but at an operating temperature of only 1010 C, have been tested for more than three years. The M-cathodes show no degradation in current over their present operating life whereas the current from the B-cathodes degrade about 6 percent after four years of operation.

Forman, R.↗

Analytical investigation of efficiency and performance limits in klystron amplifiers using multidimensional computer programs; multi-stage depressed collectors; and thermionic cathode life studies

An extensive parametric investigation was performed of the extraction of energy in output gaps of klystron amplifiers, using 3-D computer programs. Due to complexity of the program which used a hydrodynamic, axially and radially deformable disk ring model and the resulting long computing time, the investigation was limited to the output gap, by far the most important and difficult part of the klystron interaction. Results show that, for a confined flow focused beam throughout the penultimate cavity, radial velocities remain very small and the beam is highly laminar. It was, therefore, concluded that possible errors resulting from treating only the output cavity in 3-D would remain small.

Kosmahl, H. G.↗

Analytic investigation of efficiency and performance limits in klystron amplifiers using multidimensional computer programs; multi-stage depressed collectors; and thermionic cathode life studies

Due to complexity of the program which used a hydrodynamic, axially and radially deformable disk-ring model and the resulting long computing time only the output gap was investigated. Results from independent studies were used to initiate the starting conditions for the electrons and the RF voltage using our program. Although this method of computation is less exact than processing the entire klystron interaction in 3-Dimensions it is shown that, for a confined flow focused throughout the penultimate cavity, radial velocities remain very small and the beam is highly laminar. It is concluded that possible errors resulting from treating only the output cavity in 3-D would remain small.

Kosmahl, H. G.↗

Barium-Dispenser Thermionic Cathode

Improved reservoir cathode serves as intense source of electrons required for high-frequency and often high-output-power, linear-beam tubes, for which long operating lifetime important consideration. High emission-current densities obtained through use of emitting surface of relatively-low effective work function and narrow work-function distribution, consisting of coat of W/Os deposited by sputtering. Lower operating temperatures and enhanced electron emission consequently possible.

Wintucky, Edwin G.↗

Gridded thermionic gun and integral superconducting ballistic bunch compression cavity

Electron-Ion colliders such as the Medium energy Electron Ion Collider (MEIC) being developed by JLAB require high current electrons with low energy spread for electron cooling of the collider ring. Accelerator techniques for improving bunch charge, average current, emittance, and energy spread are required for Energy Recovery Linacs (ERLs) and Circulator Rings (CR) for next generation colliders for nuclear physics experiments. Example candidates include thermionic-cathode electron guns with RF accelerating structures. Thermionic cathodes are known to produce high currents and have excellent lifetime. The success of the IR and THz Free-Electron Laser (FEL) designed and installed by Advanced Energy Systems at the Fritz Haber Institute (FHI) of the Max Planck Society in Berlin [1,2] demonstrates that gridded thermionic cathodes and rf systems be considered for next generation collider technology. In Phase 1 Advanced Energy Systems (AES) developed and analyzed a design concept using a superconducting cavity pair and gridded thermionic cathode. Analysis included Beam Dynamics and thermal analysis to show that a design of this type is feasible. The latest design goals for the MEIC electron cooler were for electron bunches of 420 pC at a frequency of 952.6 MHz with a magnetic field on the cathode of 2kG. This field magnetizes the beam imparting angular momentum that provides for helical motion of the electrons in the cooling solenoid. The helical motion increases the interaction time and improves the cooling efficiency. A coil positioned around the cathode providing 2kG field was developed. Beam dynamics simulations were run to develop the particle dynamics near the cathode and grid. Lloyd Young added capability to Tstep to include space charge effects between two plates and include image charge effects from the grid. He also added new pepper-pot geometry capability to account for honeycomb grids. These additions were used to develop the beam dynamics for this gun. The general design is a modified ballistic compression cavity pair with two independently powered cells [3]. The first is a cathode cell that includes the thermionic cathode and grid to provide for beam bunching. The second is a full cell with independent phasing and field levels designed to minimize energy spread. The primary goal for Phase II is to manufacture a superconducting gun with a thermionic cathode and imbedded coil. The system developed here is applicable to many high current electron accelerators. The analysis and design constraints imposed by the magnetized cathode make the cathode system developed here more complicated and limited than one without the magnetized beam constraints. High power ERLs would benefit by a gun with the capabilities shown here, 400 mA or more of current. ERLs hold great promise for electron cooling experiments, advanced light sources and Free Electron Lasers. This high current electron injector is a technological advance that will place the requirements for an ERL capable of providing quality bunches needed for cooling within the MEIC circulator ring within reach. This injector would have application to future ERLs around the world.

43 PARTICLE ACCELERATORS↗

Electrical and thermal characteristics of LaB6 thermionic hollow cathodes operating in He, D2, Ar, and Xe at 4–200 Pa and 0.25–5 A cm−2

We report characteristics of lanthanum hexaboride (LaB6) cathodes for conditions relevant to a high-voltage, high-current switching device. LaB6 is selected because of its relatively low work function, stability in the presence of many common gas impurities, and a low evaporation rate (long life) at operating temperatures. We have investigated the effect of cathode geometry, gas type, pressure, and current on a LaB6 hollow cathode in a diode configuration with an opposing planar anode. The gas is stagnant at a relatively low pressure of 4–200 Pa (0.03–1.5 Torr) because of device high-voltage standoff requirements. In all cases, the plasma voltage decreases to a plateau value with increasing current where a practical device would operate. The plateau voltage aligns with the fill gas excitation or ionization voltage, depending on conditions. At high current, the cathode temperature exceeds that required for thermionic emission to supply the total current, a behavior that is understood by accounting for back-diffusing bulk electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functionalized carbon nanotubes for thermionic emission and cooling applications

Barium strontium oxide-coated carbon nanotubes (CNTs) were implemented as a work function lowering and field enhancing functional coating on a coiled tungsten filament to create a new thermionic cathode. This cathode resembles conventional oxide cathodes in structure. It has the same coiled tungsten filament as a conventional oxide cathode but uses barium strontium oxide-coated CNTs instead of the traditional barium strontium calcium oxide powder mixture as an emissive coating. The cathode produces a strong thermionic emission. At 1395 K and 2.5 V/μm, the thermionic emission current of 0.87 A or current density of 2.9 A/cm 2 was obtained from this oxide-coated CNT cathode. This level of emission is about three times as large as a conventional oxide cathode operating at similar temperature and field strength. Strong thermionic emissions from the cathode also lead to a large thermionic cooling effect. Temperature reduction as large as 90° was observed from the cathode surface when it was emitting electrons. Strong thermionic emission and a large cooling effect obtained are the result of the combination of the low work function of barium strontium oxide (1.6 eV) and the large field effect induced by the CNTs. Plasma enhanced chemical vapor deposition was used to grow CNTs, and magnetron sputtering deposition was used to deposit the barium strontium oxide functional coating; details of the cathode fabrication are presented to illustrate both the versatility of the processing techniques and the adaptability of barium strontium oxide-coated CNTs as a functional coating. Finally, measurements on thermionic emission and thermionic cooling of the cathode are also presented.

36 MATERIALS SCIENCE↗

Direct evidence of low work function on SrVO 3 cathode using thermionic electron emission microscopy and high-field ultraviolet photoemission spectroscopy

Perovskite SrVO 3 has recently been proposed as a novel electron emission cathode material. Density functional theory (DFT) calculations suggest multiple low work function surfaces, and recent experimental efforts have consistently demonstrated effective work functions of ~2.7 eV for polycrystalline samples, both results suggesting, but not directly confirming, that some fraction of even lower work function surface is present. In this work, thermionic electron emission microscopy (ThEEM) and high-field ultraviolet photoemission spectroscopy (UPS) are used to study the local work function distribution and measure the work function of a partially oriented- (110)-SrVO 3 perovskite oxide cathode surface. Our results show direct evidence of low work function patches of about 2.0 eV on the cathode surface, with a corresponding onset of observable thermionic emission at 750 °C. We hypothesize that, in our ThEEM and UPS experiments, the high applied electric field suppresses the patch field effect, enabling the direct measurement of local work functions. This measured work function of 2.0 eV is comparable to the previous DFT-calculated work function values of the SrVO-terminated (110) SrVO 3 surface (2.3 eV) and SrO-terminated (100) surface (1.9 eV). The measured 2.0 eV value is also much lower than the work function for the (001) LaB 6 single crystal cathode (~2.7 eV) and comparable to the effective work function of B-type dispenser cathodes (~2.1 eV). If SrVO 3 thermionic emitters can be engineered to access domains of this low 2.0 eV work function, they have the potential to significantly improve thermionic emitter-based technologies.

36 MATERIALS SCIENCE↗