Nonlinear effects due to high heat flux in thin film thermometry and means for their compensation.
Network for compensating electrical output of thin film resistance thermometers for deviations due to large heat-transfer rates
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Network for compensating electrical output of thin film resistance thermometers for deviations due to large heat-transfer rates
Thermocouple wire tested and thermoelectric measurements verified in cryogenic temperature range
Linear regression analysis of water pressure and critical temperature in plagioclase-silicate liquid equilibrium
Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.
The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle Payloads was investigated. These payloads operate from .3 Kelvin to 300 Kelvin. Standard detectors were selected and matching signal conditioning equipment were specified. This equipment will operate in a spacecraft environment and be compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical earth orbiting spacecraft. Work statements to better define and advance detector performance are presented.
Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.
The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle payloads were investigated. These payloads operate from .3 kelvin to 300 kelvin. Standard detectors were selected and matching signal conditioning equipment compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical Earth orbiting spacecraft. Work statements to better define and advance detector performance were presented.
A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0).
A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0). Previously announced in STAR as N83-20079
A concept is being explored that an optical analog of the electrical Johnson noise may be used to measure temperature independently of emissivity. The concept is that a laser beam may be modulated on reflection from a hot surface by interaction of the laser photons with the thermally agitated conduction electrons or the lattice phonons, thereby adding noise to the reflected laser beam. If the reflectance noise can be detected and quantified in a background of other noise in the optical and signal processing systems, the reflectance noise may provide a noncontact measurement of the absolute surface temperature and may be independent of the surface's emissivity.
A preliminary evaluation was made by ORNL of a two-color ratio pyrometer (TCRP) for temperature control in the Modular Electromagnetic Levitation (MEL) experiment. A discussion was presented by Eric Spjut at the 1987 NASA Non-Contact Temperature Measurement Workshop (NASA Conf. Publ. 2503, pp. 182-213) in which he described the non-linear characteristics of the time response of TCPs. Researchers replicated his model and results and note that the non-linear response behavior is minimized for small temperature steps at high temperatures. They then used the predicted response in a model for a proportional or integral feedback controller and predicted the control characteristics for heating and cooling a 5-mm diameter sphere of niobium at high (1500 to 2750 K) temperatures. The analysis shows that for a slow (25-ms) time response for a commercial RCRP, overshoots of several hundred kelvins will result from a 100-K decrease in the setpoint, and temperature tracking errors of 14 to 45 K will occur for control temperature ramps of 1000K/s. For a fast (greater than 0.1 ms) time response, the overshoot and ramp response errors are largely eliminated.
The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.
Thermodynamic properties of the alpha/beta phase transformation in terrestrial troilite (FeS), as measured by differential scanning calorimetry (DSC), vary systematically with prior thermal history of the troilite, as imposed under laboratory conditions. Both the transition temperature and enthalpy change for the alpha/beta transformation decrease with increasing maximum temperature of prior heat treatment. DSC measurements on troilite from various meteorites indicate clear differences in the alpha/beta thermodynamic properties that are consistent with differences in the natural thermal histories of the meteorites.
An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.
High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.
An experiment has been conducted to acquire data for the validation of computational fluid dynamics (CFD) codes used in the design of supersonic combustors. The primary measurement technique is coherent anti-Stokes Raman spectroscopy (CARS), although surface pressures and temperatures have also been acquired. Modern- design- of-experiment techniques have been used to maximize the quality of the data set (for the given level of effort) and minimize systematic errors. The combustor consists of a diverging duct with single downstream- angled wall injector. Nominal entrance Mach number is 2 and enthalpy nominally corresponds to Mach 7 flight. Temperature maps are obtained at several planes in the flow for two cases: in one case the combustor is piloted by injecting fuel upstream of the main injector, the second is not. Boundary conditions and uncertainties are adequately characterized. Accurate CFD calculation of the flow will ultimately require accurate modeling of the chemical kinetics and turbulence-chemistry interactions as well as accurate modeling of the turbulent mixing
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic combustor. Experiments were conducted in NASA Langley Research Center's Direct Connect Supersonic Combustion Test Facility. In this facility, hydrogen and air bum to increase the enthalpy of the test gas; O2 is then added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model consisting of a short constant-area section followed by a small rearward facing step and another constant area section. At the end of this straight section H2 fuel is then injected at Mach 2 and at 30 deg. angle with respect to the freestream. One wall of the duct then expands at a 3 deg. angle for over 1 meter. The ensuing combustion is monitored optically through ports in the side of the combustor. CARS measurements were performed at the nozzle exit and at four different planes downstream fuel injection. Maps were obtained of the mean temperature, as well as quantitative N2 and O2 and qualitative H2 mean mole fraction fields. Correlations between fluctuations of the different measured parameters are presented for one of the planes of data.