Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of correlated charge noise in superconducting qubits at an underground facility

The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $0.19^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting quasiparticle-amplifying transmon: A qubit-based sensor for meV-scale phonons and single terahertz photons

With great interest from the quantum computing community, an immense amount of R&D effort has been invested into improving superconducting qubits. The technologies developed for the design and fabrication of these qubits can be directly applied to applications for ultralow-threshold particle detectors, e.g., low-mass dark matter and far-infrared photon sensing. We propose a novel energy-resolving sensor based on the transmon qubit architecture combined with a signal-enhancing superconducting quasiparticle amplification stage. We refer to these sensors as SQUATs: superconducting quasiparticle-amplifying transmons. We detail the operating principle and design of this new sensor and predict that, with minimal R&D effort, solid-state-based detectors patterned with these sensors can achieve sensitivity to single terahertz photons, and sensitivity to 1 meV phonons in the detector absorber substrate on the microsecond timescale. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Revisiting the dark matter interpretation of excess rates in semiconductors

In light of recent results from low-threshold dark matter detectors, we revisit the possibility of a common dark matter origin for multiple excesses across numerous direct detection experiments, with a focus on the excess rates in semiconductor detectors. We explore the interpretation of the low-threshold calorimetric excess rates above 40 eV in the silicon SuperCDMS Cryogenic Phonon Detector and above 100 eV in the germanium EDELWEISS Surface detector as arising from a common but unknown origin, and demonstrate a compatible fit for the observed energy spectra in both experiments, which follow a power law of index α = 3.4 3 - 0.06 + 0.11 . Despite the intriguing scaling of the normalization of these two excess rates with approximately the square of the mass number A 2 , we argue that the possibility of common origin by dark matter scattering via nuclear recoils is strongly disfavored, even allowing for exotic condensed matter effects in an as-yet unmeasured kinematic regime, due to the unphysically large dark matter velocity required to give comparable rates in the different energy ranges of the silicon and germanium excesses. We also investigate the possibility of inelastic nuclear scattering by cosmic ray neutrons, solar neutrinos, and photons as the origin, and quantitatively disfavor all three based on known fluxes of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Novel Method for Setting Meaningful Thresholds for RMS-Energy Oscillation Detectors

Oscillation detection and mitigation is a crucial aspect of reliable power system operation. Several transmission system operators and reliability coordinators use the RMS-energy method of oscillation detection, but the process of setting thresholds is time and labor intensive. The current industry practice in the United States is to set thresholds based on the RMS-energy's value during ambient conditions, which can often lead to nuisance alarms that require thresholds to be manually retuned. In this paper, we propose a method for setting RMS-energy thresholds that directly accounts for oscillation amplitudes specified by the user. A theoretical analysis of the statistical properties of the RMS-energy incorporates these user-specified amplitudes, resulting in thresholds that reliably detect oscillations of interest while avoiding nuisance alarms. Theoretical results are validated with simulated measurements and the real-world practicality of the method is established with publicly available field-measured data from the Grid Event Signature Library.

Follum, James D.↗

First Limits on Light Dark Matter Interactions in a Low Threshold Two-Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5⁢(4) m⁢ eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g ×12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M⁢ eV/c 2 , with the lowest unexplored cross section of 4⁢ × 10 −32 c⁢m 2 at 87 M⁢ eV/c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pursuing the Ultimate Power of Xenon Dark Matter Detectors (Annual Progress Report)

Liquid xenon-based experiments have been leading direct searches for dark matter – a cornerstone of modern cosmology and particle physics. Despite rapid improvement of experimental sensitivities in the past two decades, no definitive dark matter interactions have been observed. This project aims to expand the physics reach of existing and future xenon dark matter experiments, especially for low-mass dark matter interactions that would fall below the energy thresholds of current detectors. The main approach is to thoroughly characterize and to suppress the low-energy electron background observed in dual-phase xenon Time Projection Chambers (TPCs), which has so far prevented these detectors from achieving lower energy thresholds. Per recent discussion with and approval from the program manager, we have added a new task of experimentally measuring the Migdal effect to this project. The Migdal effect predicts that ultra-low energy dark matter interactions may produce detectable electron recoil signals in liquid xenon at the keV level in addition to much lower energy nuclear recoils. If this effect is experimentally measured, it will drastically improve xenon detectors’ sensitivity to subGeV dark matter interactions. This new task shares strong synergy with the original project goal of pursuing the ultimate power of xenon dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Toward a DM Search with Phonon-Mediated MKID Devices at NEXUS

To continue the search for dark matter (DM) into the sub-GeV mass range, the development and characterization of new detectors with sub-eV thresholds is critical. Microwave Kinetic Inductance Detectors (MKIDs) offer an attractive architecture for novel microcalorimeters with the requisite energy resolution and threshold for probing DM down to the fermionic thermal relic mass limit of a few keV. A phonon-sensitive MKID device featuring an aluminum resonator patterned onto a silicon substrate has been operating at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. Currently, our estimate of the energy resolution of this device is limited by the efficiency for phonons produced via particle interactions in the substrate to propagate to the superconductor and break Cooper pairs. In this poster, I will present our constraints on the substrate-superconductor coupling and the progress on an absolute energy calibration performed by exposing the rear of the substrate to a pulsed source of 470 nm photons. I will also review the current status and next steps of the phonon-mediated MKID effort at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The physics potential of a reactor neutrino experiment with Skipper-CCDs: searching for new physics with light mediators

In this work, we explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of models which benefit from the very low energy recoil threshold of these detectors, namely neutrino magnetic moments and light mediators coupled to neutrinos and quarks or electrons. We find that this experimental setup is very sensitive to light, weakly coupled new physics, and in particular that it could probe potential explanations of the event excess observed in XENON1T. We also provide a detailed study on the dependence of the sensitivity on the experimental setup assumptions and on the neutrino flux systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium-Tritium Filled MagLIF Implosions on Sandia’s Z-Machine

Nuclear reaction history measurements provide a bang time and burn width of Inertial Confinement Fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T,γ) 5 He reaction. Such DT based reaction history measurements have not been made on the Magnetized Laser Inertial Fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history on the Z-Machine. A forward model of the Gamma Reaction History diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte-Carlo N-Particle) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector, and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T 2 gas doping of MagLIF implosions a reaction history may be made for high performance shots >8e12-2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions that additional collimation will be needed to prevent the neutron induced gamma rays from modifying the shape of the measured DT reaction history curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thresholded quantum sensing with a frustrated Kitaev trimer

We investigate the response of a Ramsey interferometric quantum sensor based on a frustrated, three-spin system (a Kitaev trimer) to a classical time-dependent field (signal). The system eigenspectrum is symmetric about a critical point, |𝒃| = 0, with four of the spectral components varying approximately linearly with the magnetic field and four exhibiting a nonlinear dependence. Under the adiabatic approximation and for appropriate initial states, we show that the sensor's response to a zero-mean signal is such that below a threshold, |𝒃| <⁢ 𝑏 th , the sensor does not respond to the signal, whereas above the threshold, the sensor acts as a detector that the signal has occurred. This thresholded response is approximately omnidirectional. Moreover, when deployed in an entangled multisensor configuration, the sensor achieves sensitivity at the Heisenberg limit. Such detectors could be useful both as stand-alone units for signal detection above a noise threshold and in two- or three-dimensional arrays, analogous to a quantum bubble chamber, for applications such as particle track detection and long-baseline telescopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗